160 resultados para D-dimer
em Queensland University of Technology - ePrints Archive
Resumo:
Background: Plasma D-dimer tests are currently used to exclude deep vein thrombosis and pulmonary embolism. Human saliva has numerous advantages over blood as a diagnostic sample. The aims of our study were to develop a reliable immunoassay to detect D-dimer levels in saliva, and to determine the correlation between salivary and blood D-dimer levels. Results/methodology: Saliva and blood samples were collected from 40 healthy volunteers. We developed a AlphaLISA((R)) immunoassay with acceptable analytical performances to quantify D-dimer levels in the samples. The median salivary D-dimer levels were 138.1 ng/ml (morning) and 140.7 ng/ml (afternoon), and the plasma levels were 75.0 ng/ml. Salivary D-dimer levels did not correlate with plasma levels (p = 0.61). Conclusion: For the first time, we have quantified D-dimer levels and found twofold increase in saliva (p < 0.05) than in plasma. Further studies are required to demonstrate the clinical relevance/utility of salivary D-dimer in patients with confirmed deep vein thrombosis and/or pulmonary embolism.
Resumo:
Introduction We have previously shown that the concentrations of D-dimer are significantly elevated in saliva compared with plasma. Saliva offers several advantages compared with blood analysis. We hypothesised that human saliva contains plasminogen activator inhibitor-1 (PAI-1) and that the concentrations are not affected by the time of saliva collection. The aim was to adopt and validate an immunoassay to quantify PAI-1 concentrations in saliva and to determine whether saliva collection time has an influence in the measurement. Materials and methods Two saliva samples (morning and afternoon) from the same day were collected from healthy subjects (N = 40) who have had no underlying heart conditions. A customized AlphaLISA® immunoassay (PerkinElmer®, MA, USA) was adopted and used to quantify PAI-1 concentrations. We validated the analytical performance of the customized immunoassay by calculating recovery of known amount of analyte spiked in saliva. Results: The recovery (95.03%), intra- (8.59%) and inter-assay (7.52%) variations were within the acceptable ranges. The median salivary PAI-1 concentrations were 394 pg/mL (interquartile ranges (IQR) 243.4-833.1 pg/mL) in the morning and 376 (129.1-615.4) pg/mL in the afternoon and the plasma concentration was 59,000 (24,000-110,000) pg/mL. Salivary PAI-1 did not correlate with plasma (P = 0.812). Conclusions The adopted immunoassay produced acceptable assay sensitivity and specificity. The data demonstrated that saliva contains PAI-1 and that its concentration is not affected by the time of saliva collection. There is no correlation between salivary and plasma PAI-1 concentrations. Further studies are required to demonstrate the utility of salivary PAI-1 in CVD risk factor studies.
Resumo:
Background and purpose: The purpose of this study is to examine the feasibility of developing plasma predictive value biomarkers of cerebral ischemic stroke before imaging evidence is acquired. Methods: Blood samples were obtained from 198 patients who attended our neurology department as emergencies - with symptoms of vertigo, numbness, limb weakness, etc. - within 4.5 h of symptom onset, and before imaging evidence was obtained and medical treatment. After the final diagnosis was made by MRI/DWI/MRA or CTA in the following 24-72 h, the above cases were divided into two groups: stroke group and non-stroke group according to the imaging results. The levels of baseline plasma antithrombin III (AT-III), thrombin-antithrombin III (TAT), fibrinogen, D-dimer and high-sensitivity C-reactive protein (hsCRP) in the two groups were assayed. Results: The level of the baseline AT-III in the stroke group was 118.07 ± 26.22%, which was lower than that of the non-stroke group (283.83 ± 38.39%). The levels of TAT, fibrinogen, hsCRP were 7.24 ± 2.28 μg/L, 5.49 ± 0.98 g/L, and 2.17 ± 1.07 mg/L, respectively, which were higher than those of the non-stroke group (2.53 ± 1.23 μg/L, 3.35 ± 0.50 g/L, 1.82 ± 0.67 mg/L). All the P-values were less than 0.001. The D-dimer level was 322.57 ± 60.34 μg/L, which was slightly higher than that of the non-stroke group (305.76 ± 49.52 μg/L), but the P-value was 0.667. The sensitivities of AT-III, TAT, fibrinogen, D-dimer and hsCRP for predicting ischemic stroke tendency were 97.37%, 96.05%, 3.29%, 7.89%, but the specificity was 93.62%, 82.61%, 100% and 100%, respectively, and all the P-values were less than 0.001. High levels of D-dimer and hsCRP were mainly seen in the few cases with severe large-vessel infarction. Conclusions: Clinical manifestations of acute focal neurological deficits were associated with plasma AT-III and fibrinogen. These tests might help the risk assessment of acute cerebral ischemic stroke and/or TIA with infarction tendency in the superacute stage before positive imaging evidence is obtained.
Resumo:
An in vivo screen has been devised for NF-κB p50 activity in Escherichia coli exploiting the ability of the mammalian transcription factor to emulate a prokaryotic repressor. Active intracellular p50 was shown to repress the expression of a green fluorescent protein reporter gene allowing for visual screening of colonies expressing active p50 on agar plates. A library of mutants was constructed in which the residues Y267, L269, A308 and V310 of the dimer interface were simultaneously randomised and twenty-five novel functional interfaces were selected which repressed the reporter gene to similar levels as the wild-type protein. The leucine-269 alanine-308 core was repeatedly, but not exclusively, selected from the library whilst a diversity of predominantly non-polar residues were selected at positions 267 and 310. These results indicate that L269 and A308 may form a hot spot of interaction and allow an insight into the processes of dimer selectivity and evolution within this family of transcription factors.
Resumo:
This study assesses the Vitamin D status of 126 healthy free-living adults aged 18–87 years, in southeast Queensland, Australia (27°S) at the end of the 2006 winter. Participants provided blood samples for analysis of 25(OH)D (the measure of an individual’s Vitamin D status), PTH, Calcium, Phosphate, and Albumin, completed a questionnaire on sun-protective/sun-exposure behaviours, and were assessed for phenotypic characteristics such as skin/hair/eye colour and BMI. We found that 10.2% of the participants had serum 25(OH)D levels below 25 nmol/l (considered deficient) and a further 32.3% had levels between 25 nmol/l and 50 nmol/l (considered insufficient). Our results show that low levels of 25(OH)D can occur in a substantial proportion of the population at the end of winter, even in a sunny climate. 25(OH)D levels were higher amongst those who spent more time in the sun and lower among obese participants (BMI > 30) than those who were not obese (BMI < 30). 25(OH)D levels were also lower in participants who had black hair, dark/olive skin, or brown eyes, when compared with participants who had brown or fair hair, fair skin, or blue/green eyes. No associations were found between 25(OH)D status and age, gender, smoking status, or the use of sunscreen.
Resumo:
Vitamin D deficiency and insufficiency are now seen as a contemporary health problem in Australia with possible widespread health effects not limited to bone health1. Despite this, the Vitamin D status (measured as serum 25-hydroxyvitamin D (25(OH)D)) of ambulatory adults has been overlooked in this country. Serum 25(OH)D status is especially important among this group as studies have shown a link between Vitamin D and fall risk in older adults2. Limited data also exists on the contributions of sun exposure via ultraviolet radiation and dietary intake to serum 25(OH)D status in this population. The aims of this project were to assess the serum 25(OH)D status of a group of older ambulatory adults in South East Queensland, to assess the association between their serum 25(OH)D status and functional measures as possible indicators of fall risk, obtain data on the sources of Vitamin D in this population and assess whether this intake was related to serum 25(OH)D status and describe sun protection and exposure behaviors in this group and investigate whether a relationship existed between these and serum 25(OH)D status. The collection of this data assists in addressing key gaps identified in the literature with regard to this population group and their Vitamin D status in Australia. A representative convenience sample of participants (N=47) over 55 years of age was recruited for this cross-sectional, exploratory study which was undertaken in December 2007 in south-east Queensland (Brisbane and Sunshine coast). Participants were required to complete a sun exposure questionnaire in addition to a Calcium and Vitamin D food frequency questionnaire. Timed up and go and handgrip dynamometry tests were used to examine functional capacity. Serum 25(OH)D status and blood measures of Calcium, Phosphorus and Albumin were determined through blood tests. The Mean and Median serum 25-Hydroxyvitamin D (25(OH)D) for all participants in this study was 85.8nmol/L (Standard Deviation 29.7nmol/L) and 81.0nmol/L (Range 22-158nmol/L), respectively. Analysis at the bivariate level revealed a statistically significant relationship between serum 25(OH)D status and location, with participants living on the Sunshine Coast having a mean serum 25(OH)D status 21.3nmol/L higher than participants living in Brisbane (p=0.014). While at the descriptive level there was an apparent trend towards higher outdoor exposure and increasing levels of serum 25(OH)D, no statistically significant associations between the sun measures of outdoor exposure, sun protection behaviors and phenotypic characteristics and serum 25(OH)D status were observed. Intake of both Calcium and Vitamin D was low in this sample with sixty-eight (68%) of participants not meeting the Estimated Average Requirements (EAR) for Calcium (Median=771.0mg; Range=218.0-2616.0mg), while eighty-seven (87%) did not meet the Adequate Intake for Vitamin D (Median=4.46ug; Range=0.13-30.0ug). This raises the question of how realistic meeting the new Adequate Intakes for Vitamin D is, when there is such a low level of Vitamin D fortification in this country. However, participants meeting the Adequate Intake (AI) for Vitamin D were observed to have a significantly higher serum 25(OH)D status compared to those not meeting the AI for Vitamin D (p=0.036), showing that meeting the AI for Vitamin D may play a significant role in determining Vitamin D status in this population. By stratifying our data by categories of outdoor exposure time, a trend was observed between increased importance of Vitamin D dietary intake as a possible determinant of serum 25(OH)D status in participants with lower outdoor exposures. While a trend towards higher Timed Up and Go scores in participants with higher 25(OH) D status was seen, this was only significant for females (p=0.014). Handgrip strength showed statistically significant association with serum 25(OH)D status. The high serum 25(OH)D status in our sample almost certainly explains the limited relationship between functional measures and serum 25(OH)D. However, the observation of an association between slower Time Up and Go speeds, and lower serum 25(OH)D levels, even with a small sample size, is significant as slower Timed Up and Go speeds have been associated with increased fall risk in older adults3. Multivariable regression analysis revealed Location as the only significant determinant of serum 25(OH)D status at p=0.014, with trends (p=>0.1) for higher serum 25(OH)D being shown for participants that met the AI for Vitamin D and rated themselves as having a higher health status. The results of this exploratory study show that 93.6% of participants had adequate 25(OH)D status-possibly due to measurement being taken in the summer season and the convenience nature of the sample. However, many participants do not meet their dietary Calcium and Vitamin D requirements, which may indicate inadequate intake of these nutrients in older Australians and a higher risk of osteoporosis. The relationship between serum 25(OH)D and functional measures in this population also requires further study, especially in older adults displaying Vitamin D insufficiency or deficiency.
Resumo:
Exposure to ultraviolet radiation (UV) results in both damaging and beneficial health outcomes. Excessive UV exposure has been linked to many skin and eye problems, but moderate exposure induces vitamin D production. It has been reported that humans receive 90-95% of their vitamin D from production that starts after UV exposure. Although it is possible to acquire vitamin D through dietary supplementation, the average person receives very little in this manner. Therefore, since most people acquire their vitamin D from synthesis after exposure to UV from sunlight, it is very important to understand the different environments in which people encounter UV. This project measured UV radiation and in-vitro vitamin D production in the urban canyon and at a nearby suburban location. The urban canyon is an environment consisting of tall buildings and tropospheric air pollution, which have an attenuating effect on UV. Typically, UV measurements are collected in areas outside the urban canyon, meaning that at times studies and public recommendations do not accurately represent the amount of UV reaching street-level in highly urbanized areas. Understanding of UV exposure in urban canyons becomes increasingly important as the number of people working and living in large cities steadily increases worldwide. This study was conducted in the central business district (CBD) of Brisbane, Australia, which models the urban canyons of large cities around the world in that it boasts a great number of tall buildings, including many skyscrapers, meaning that most areas only see a small amount of direct sunlight each day. During the winter of 2007 measurements of UV radiation and in-vitro vitamin D production were collected in the CBD and at a suburban site approximately 2.5km outside the CBD. Air pollution data was obtained from a central CBD measurement site. Data analysis showed that urban canyon measurements of both UV radiation and in-vitro vitamin D production were significantly lower than those collected at the suburban site. These results will aid both future researchers and policy makers in better understanding human UV exposure in Brisbane’s CBD and other urban canyons around the world.