188 resultados para Contact lens, Compliance, Microbial keratitis, Case care

em Queensland University of Technology - ePrints Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The aim of this study was to characterize the clinical signs, symptoms, and ocular and systemic comorbidities in a large case series of contact lens-related microbial keratitis. Methods: Two hundred ninety-seven cases of contact lens-related microbial keratitis, aged between 15 and 64 years were detected through surveillance of hospital and community based ophthalmic practitioners in Australia and New Zealand. Full clinical data were available for 190 cases and 90 were interviewed by telephone. Clinical data included the size, location, and degree of anterior chamber response. Symptom data were available from the practitioner and from participant self-report. Associations between symptoms and disease severity were evaluated. Data on ocular and systemic disease were collected from participants and practitioners. The frequency of comorbidities was compared between the different severities of disease and to population norms. Results: More severe disease was associated with greater symptom severity and pain was the most prevalent symptom reported. Ninety-one percent of cases showed progression of ocular symptoms after lens removal, and symptom progression was associated with all severities of disease. Twenty-five percent of cases reported prior episodes requiring emergency attention. Thyroid disease (p 0.05) and self-reported poor health (p 0.001) were more common in cases compared with age-matched population norms. Discussion: Information on the signs, symptoms, and comorbidities associated with contact lens-related microbial keratitis may be useful in patient education and for practitioners involved in the fitting of lenses and management of complications. Although pain was the most common symptom experienced, progression of symptoms despite lens removal was close to universal. Poor general health, particularly respiratory disease and thyroid disease was more common in cases than in the general population, which may prompt practitioners to recommend flexibility in wear schedules when in poor health or the selection of a lower risk wear schedule in at risk patients

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To examine the relationship between contact lens (CL) case contamination and various potential predictive factors. METHODS: 74 subjects were fitted with lotrafilcon B (CIBA Vision) CLs on a daily wear basis for 1 month. Subjects were randomly assigned one of two polyhexamethylene biguanide (PHMB) preserved disinfecting solutions with the corresponding regular lens case. Clinical evaluations were conducted at lens delivery and after 1 month, when cases were collected for microbial culture. A CL care non-compliance score was determined through administration of a questionnaire and the volume of solution used was calculated for each subject. Data was examined using backward stepwise binary logistic regression. RESULTS: 68% of cases were contaminated. 35% were moderately or heavily contaminated and 36% contained gram-negative bacteria. Case contamination was significantly associated with subjective dryness symptoms (OR 4.22, CI 1.37–13.01) (P<0.05). There was no association between contamination and subject age, ethnicity, gender, average wearing time, amount of solution used, non-compliance score, CL power and subjective redness (P>0.05). The effect of lens care system on case contamination approached significance (P=0.07). Failure to rinse the case with disinfecting solution following CL insertion (OR 2.51, CI 0.52–12.09) and not air drying the case (OR 2.31, CI 0.39–13.35) were positively correlated with contamination; however, did not reach statistical significance. CONCLUSIONS: Our results suggest that case contamination may influence subjective comfort. It is difficult to predict the development of case contamination from a variety of clinical factors. The efficacy of CL solutions, bacterial resistance to disinfection and biofilm formation are likely to play a role. Further evaluation of these factors will improve our understanding of the development of case contamination and its clinical impact.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To establish risk factors for moderate and severe microbial keratitis among daily contact lens (CL) wearers in Australia. Design: A prospective, 12-month, population-based, case-control study. Participants: New cases of moderate and severe microbial keratitis in daily wear CL users presenting in Australia over a 12-month period were identified through surveillance of all ophthalmic practitioners. Case detection was augmented by record audits at major ophthalmic centers. Controls were users of daily wear CLs in the community identified using a national telephone survey. Testing: Cases and controls were interviewed by telephone to determine subject demographics and CL wear history. Multiple binary logistic regression was used to determine independent risk factors and univariate population attributable risk percentage (PAR%) was estimated for each risk factor.; Main Outcome Measures: Independent risk factors, relative risk (with 95% confidence intervals [CIs]), and PAR%. Results: There were 90 eligible moderate and severe cases related to daily wear of CLs reported during the study period. We identified 1090 community controls using daily wear CLs. Independent risk factors for moderate and severe keratitis while adjusting for age, gender, and lens material type included poor storage case hygiene 6.4× (95% CI, 1.9-21.8; PAR, 49%), infrequent storage case replacement 5.4× (95% CI, 1.5-18.9; PAR, 27%), solution type 7.2× (95% CI, 2.3-22.5; PAR, 35%), occasional overnight lens use (<1 night per week) 6.5× (95% CI, 1.3-31.7; PAR, 23%), high socioeconomic status 4.1× (95% CI, 1.2-14.4; PAR, 31%), and smoking 3.7× (95% CI, 1.1-12.8; PAR, 31%). Conclusions: Moderate and severe microbial keratitis associated with daily use of CLs was independently associated with factors likely to cause contamination of CL storage cases (frequency of storage case replacement, hygiene, and solution type). Other factors included occasional overnight use of CLs, smoking, and socioeconomic class. Disease load may be considerably reduced by attention to modifiable risk factors related to CL storage case practice.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

It was widely anticipated that after the introduction of silicone hydrogel lenses, the risk of microbial keratitis would be lower than with hydrogel lenses because of the reduction in hypoxic effects on the corneal epithelium. Large-scale epidemiological studies have confirmed that the absolute and relative risk of microbial keratitis is unchanged with overnight use of silicone hydrogel materials. The key findings include the following: (1) The risk of infection with 30 nights of silicone hydrogel use is equivalent to 6 nights of hydrogel extended wear; (2) Occasional overnight lens use is associated with a greater risk than daily lens use; (3) The rate of vision loss due to corneal infection with silicone hydrogel contact lenses is similar to that seen in hydrogel lenses; (4) The spectrum of causative organisms is similar to that seen in hydrogel lenses, and the material type does not impact the corneal location of presumed microbial keratitis; and (5) Modifiable risk factors for infection include overnight lens use, the degree of exposure, failing to wash hands before lens handling, and storage case hygiene practice. The lack of change in the absolute risk of disease would suggest that exposure to large number of pathogenic organisms can overcome any advantages obtained from eliminating the hypoxic effects of contact lenses. Epidemiological studies remain important in the assessment of new materials and modalities. Consideration of an early adopter effect with studies involving new materials and modalities and further investigation of the impact of second-generation silicone hydrogel materials is warranted.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Eye care practitioners (ECPs) would tend to agree that wearing contact lenses increases the risk for infection, but millions of patients are still fitted with lenses every year because ECPs feel that the risk is manageable and that their patients' eye health can be protected. The Fusarium and Acanthamoeba keratitis outbreaks of years past were a wake-up call to manufacturers, ECPs, and regulatory agencies that risk cannot be managed without diligence, and that the complex relationship between contact lens materials, contact lens solutions, and compliance needs to be better understood in order to optimize the efficacy of contact lens care and improve care guidelines.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thoroughly revised and updated, this popular book provides a comprehensive yet easy to read guide to modern contact lens practice. Beautifully re-designed in a clean, contemporary layout, this second edition presents relevant and up-to-date information in a systematic manner, with a logical flow of subject matter from front to back. This book wonderfully captures the ‘middle ground’ in the contact lens field … somewhere between a dense research-based tome and a basic fitting guide. As such, it is ideally suited for both students and general eye care practitioners who require a practical, accessible and uncluttered account of the contact lens field. Contents Part 1 Introduction Historical perspective. The anterior eye Visual optics Clinical instruments Part 2 Soft contact lenses Soft lens materials Soft lens manufacture Soft lens optics Soft lens measurement Soft lens design and fitting Soft toric lens design and fitting Soft lens care systems Part 3 Rigid contact lenses Rigid lens materials Rigid lens manufacture Rigid lens optics Rigid lens measurement Rigid lens design and fitting Rigid toric lens design and fitting Rigid lens care systems Part 4 Lens replacement modalities Unplanned lens replacement Daily soft lens replacement Planned soft lens replacement Planned rigid lens replacement Part 5 Special lenses and fitting considerations Scleral lenses Tinted lenses Presbyopia Continuous wear Sport Keratoconus High ametropia Paediatric fitting Therapeutic applications Post-refractive Surgery Post-keratoplasty Orthokeratology Diabetes Part 6 Patient examination and management History taking Preliminary examination Patient education Aftercare Complications Digital imaging Compliance Practice management Appendices Index

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Moderator Opening The early focus of contact lens wear and ocular health was on oxygen delivery. However, as we learn more about how the eye works, and investigate how the contact lens interacts with the cornea, the role of the tear film has risen in prominence. A healthy tear film is critical for normal ocular homeostasis, and abnormalities of the tear film are the primary cause of dry eye. In order to improve patient eye health and comfort during lens wear, we need to further elucidate the relationship among contact lenses, contact lens solutions, the tear film, and the corneal epithelium, and find ways to maintain homeostasis of the ocular surface. In this section, we review the latest data and opinions on this complex relationship between contact lenses and lens care solutions

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this, the 10th anniversary of the introduction of silicone hydrogel contact lenses onto the market, it is perhaps timely to attempt to reconcile the apparently disparate results from different authors in relation to the incidence of keratitis with silicone hydrogel lenses and indeed, with contact lenses in general. In attempting to understand the findings of these various studies, we propose that consideration be given to the competing effects of an improved physiological response due to increased corneal oxygenation with these lenses versus their mechanical impact...

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Contact lenses are a successful and popular means to correct refractive error and are worn by just under 700,000 Australians1 and approximately 125 million people worldwide. The most serious complication of contact lens wear is microbial keratitis, a potentially sight-threatening corneal infection most often caused by bacteria. Gram-negative bacteria, in particular pseudomonas species, account for the majority of severe bacterial infections. Pathogens such as fungi or amoebae, which feature less often, are associated with significant morbidity. These unusual pathogens have come into the spotlight in recent times with an apparent association with specific lens cleaning solutions...

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE. To examine the deposition of tear phospholipids and cholesterol onto worn contact lenses and the effect of lens material and lens care solution. METHODS. Lipids were extracted from tears and worn contact lenses using 2:1 chloroform: Methanol and the extract washed with aqueous ammonium acetate, before analysis by electrospray ionization tandem mass spectrometry (ESI-MS/MS). RESULTS. Twenty-three molecular lipids from the sphingomyelin (SM) and phosphatidylcholine (PC) classes were detected in tears, with total concentrations of each class determined to be 5 ± 1 pmol/μL (~3.8 μg/mL) and 6 ± 1 pmol/μL (~ 4.6μg/mL), respectively. The profile of individual phospholipids in both of these classes was shown to be similar in contact lens deposits. Deposition of representative polar and nonpolar lipids were shown to be significantly higher on senofilcon A contact lenses, with ~59 ng/lens SM, 195 ng/lens PC, and 9.9 μg/lens cholesterol detected, whereas balafilcon A lens extracts contained ~19 ng/lens SM, 19 ng/lens PC, and 3.9 μg/lens cholesterol. Extracts from lenses disinfected and cleaned with two lens care solutions showed no significant differences in total PC and SM concentrations; however, a greater proportion of PC than SM was observed, compared with that in tears. CONCLUSIONS. Phospholipid deposits extracted from worn contact lenses show a molecular profile similar to that in tears. The concentration of representative polar and nonpolar lipids deposited onto contact lenses is significantly affected by lens composition. There is a differential efficacy in the removal of PC and SM with lens care solutions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The aim was to document contact lens prescribing trends in Australia between 2000 and 2009. ---------- Methods: A survey of contact lens prescribing trends was conducted each year between 2000 and 2009. Australian optometrists were asked to provide information relating to 10 consecutive contact lens fittings between January and March each year. ---------- Results: Over the 10-year survey period, 1,462 practitioners returned survey forms representing a total of 13,721 contact lens fittings. The mean age (± SD) of lens wearers was 33.2 ± 13.6 years and 65 per cent were female. Between 2006 and 2009, rigid lens new fittings decreased from 18 to one per cent. Low water content lenses reduced from 11.5 to 3.2 per cent of soft lens fittings between 2000 and 2008. Between 2005 and 2009, toric lenses and multifocal lenses represented 26 and eight per cent, respectively, of all soft lenses fitted. Daily disposable, one- to two-week replacement and monthly replacement lenses accounted for 11.6, 30.0 and 46.5 per cent of all soft lens fittings over the survey period, respectively. The proportion of new soft fittings and refittings prescribed as extended wear has generally declined throughout the past decade. Multi-purpose lens care solutions dominate the market. Rigid lenses and monthly replacement soft lenses are predominantly worn on a full-time basis, whereas daily disposable soft lenses are mainly worn part-time.---------- Conclusions: This survey indicates that technological advances, such as the development of new lens materials, manufacturing methods and lens designs, and the availability of various lens replacement options, have had a significant impact on the contact lens market during the first decade of the 21st Century.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: Silicone hydrogel contact lenses (CLs) are becoming increasingly popular for daily wear (DW), extended wear (EW) and continuous wear (CW), due to their higher oxygen transmissibility compared to hydrogel CLs. The aim of this study was to investigate the clinical and subjective performance of asmofilcon A (Menicon Co., Ltd), a new surface treated silicone hydrogel CL, during 6-night EW over 6 months (M). Methods: A prospective, randomised, single-masked, monadic study was conducted. N=60 experienced DW soft CL wearers were randomly assigned to wear either asmofilcon A (test: Dk=129, water content (WC)=40%, Nanogloss surface treatment) or senofilcon A (control: Dk=103, WC=38%, PVP internal wetting agent, Vistakon, Johnson & Johnson Vision Care) CLs bilaterally for 6 M on an EW basis. A PHMB-preserved solution (Menicon Co., Ltd) was dispensed for CL care. Evaluations were conducted at CL delivery and after 1 week (W), 4 W, 3 M and 6 M of EW. At each visit, a range of objective and subjective clinical performance measures were assessed. Results: N=50 subjects (83%) successfully completed the study, with the majority of discontinuations due to loss to follow-up (n=3) or moving away/travel (n=5). N=2 subjects experienced adverse events; n=1 unilateral red eye with asmofilcon A and n=1 asymptomatic infiltrate with senofilcon A. There were no significant differences in high or low contrast distance visual acuity (HCDVA or LCDVA) between asmofilcon A and senofilcon A; however, LCDVA decreased significantly over time with both CL types (p<0.05). The two CL types did not vary significantly with respect to any of the objective and subjective measures assessed (p>0.05); CL fitting characteristics and CL surface measurements were very similar and mean bulbar and limbal redness measures were always less than grade 1.0. Superior palpebral conjunctival injection showed a statistically, but not clinically, significant increase over time with both CL types (p<0.05). Corneal staining did not vary significantly between asmofilcon A and senofilcon A (p>0.05), with low median gradings of less than 0.5 observed for all areas assessed. There were no solution-related staining reactions observed with either CL type. The asmofilcon A and senofilcon A CLs were both rated highly with respect to overall comfort, with medians of 14 or 15 hours of comfortable lens wearing time per day reported at each of the study visits (p>0.05). Conclusions: Over 6 months of EW, the asmofilcon A and senofilcon A CLs performed in a similar manner with respect to visual acuity, ocular health and CL performance measures. Some changes over time were observed with both CL types, including reduced LCDVA and increased superior palpebral injection, which warrant further investigation in longer-term EW studies. Asmofilcon A appeared to be equivalent in performance to senofilcon A.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives To characterize and discover the determinants of the frequency of wear (FOW) of contact lenses. Methods Survey forms were sent to contact lens fitters in up to 40 countries between January and March every year for 5 consecutive years (2007–2011). Practitioners were asked to record data relating to the first 10 contact lens fits or refits performed after receiving the survey form. Only data for daily wear lens fits were analyzed. Results Data were collected in relation to 74,510 and 9,014 soft and rigid lens fits, respectively. Overall, FOW was 5.9±1.7 days per week (DPW). When considering the proportion of lenses worn between one to seven DPW, the distribution for rigid lenses is skewed toward full-time wear (7 DPW), whereas the distribution for soft daily disposable lenses is perhaps bimodal, with large and small peaks at seven and two DPW, respectively. There is a significant variation in FOW among nations (P<0.0001), ranging from 6.8±1.0 DPW in Greece to 5.1±2.5 DPW in Kuwait. For soft lenses, FOW increases with decreasing age. Females (6.0±1.6 DPW) wear lenses more frequently than males (5.8±1.7 DPW) (P=0.0002). FOW is greater among those wearing presbyopic corrections (6.1±1.4 DPW) compared with spherical (5.9±1.7 DPW) and toric (5.9±1.6 DPW) designs (P<0.0001). FOW with hydrogel peroxide systems (6.4±1.1 DPW) was greater than that with multipurpose systems (6.2±1.3 DPW) (P<0.0001). Conclusions Numerous demographic and contact lens–related factors impact FOW. There may be a future trend toward a lower FOW associated with the increasing popularity of daily disposable lenses.