190 resultados para Coherent light
em Queensland University of Technology - ePrints Archive
Resumo:
Kimberlite drill core from the Muskox pipe (Northern Slave Province, Nunavut, Canada) highlights the difficulties in distinguishing coherent from fragmental kimberlite and assessing the volcanological implications of the apparent gradational contact between the two facies. Using field log data, petrography, and several methods to quantify crystal and xenolith sizes and abundances, the pipe is divided into two main facies, dark-coloured massive kimberlite (DMK) and light-coloured fragmental kimberlite (LFK). DMK is massive and homogeneous, containing country-rock lithic clasts (~ 10%) and olivine macrocrysts (~ 15%) set in a dark, typically well crystallised, interstitial medium containing abundant microphenocrysts of olivine (~ 15%), opaques and locally monticellite, all of which are enclosed by mostly serpentine. In general, LFK is also massive and structureless, containing ~ 20% country-rock lithic clasts and ~ 12% olivine macrocrysts. These framework components are supported in a matrix of serpentinized olivine microphenocrysts (10%), microlites of clinopyroxene, and phlogopite, all of which are enclosed by serpentine. The contact between DMK and LFK facies is rarely sharp, and more commonly is gradational (from 5 cm to ~ 10 m). The contact divides the pipe roughly in half and is sub-vertical with an irregular shape, locally placing DMK facies both above and below the fragmental rocks. Most features of DMK are consistent with a fragmental origin, particularly the crystal- and xenolith-rich nature (~ 55-65%), but there are some similarities with rocks described as coherent kimberlite in the literature. We discuss possible origins of gradational contacts and consider the significance for understanding the origin of the DMK facies, with an emphasis on the complications of alteration overprinting of primary textures.
Resumo:
Cities of Light is the first global overview of modern urban illumination, a development that allows human wakefulness to colonize the night, doubling the hours available for purposeful and industrious activities. Urban lighting is undergoing a revolution due to recent developments in lighting technology, and increased focus on sustainability and human-scaled environments. Cities of Light is expansive in coverage, spanning two centuries and touching on developments on six continents, without diluting its central focus on architectural and urban lighting. Covering history, geography, theory, and speculation in urban lighting, readers will have numerous points of entry into the book, finding it easy to navigate for a quick reference and or a coherent narrative if read straight through. With chapters written by respected scholars and highly-regarded contemporary practitioners, this book will delight students and practitioners of architectural and urban history, area and cultural studies, and lighting design professionals and the institutional and municipal authorities they serve. At a moment when the entire world is being reshaped by new lighting technologies and new design attitudes, the longer history of urban lighting remains fragmentary. Cities of Light aims to provide a global framework for historical studies of urban lighting and to offer a new perspective on the fast-moving developments of lighting today.
Resumo:
This paper assesses and compares the performances of two daylight collection strategies, one passive and one active, for large-scale mirrored light pipes (MLP) illuminating deep plan buildings. Both strategies use laser cut panels (LCP) as the main component of the collection system. The passive system comprises LCPs in pyramid form, whereas the active system uses a tiled LCP on a simple rotation mechanism that rotates 360° in 24 hours. Performance is assessed using scale model testing under sunny sky conditions and mathematical modelling. Results show average illuminance levels for the pyramid LCP ranging from 50 to 250 lux and 150 to 200 lux for the rotating LCPs. Both systems improve the performance of a MLP. The pyramid LCP increases the performance of a MLP by 2.5 times and the rotating LCP by 5 times, when compared to an open pipe particularly for low sun elevation angles.
Resumo:
A method is presented for the development of a regional Landsat-5 Thematic Mapper (TM) and Landsat-7 Enhanced Thematic Mapper plus (ETM+) spectral greenness index, coherent with a six-dimensional index set, based on a single ETM+ spectral image of a reference landscape. The first three indices of the set are determined by a polar transformation of the first three principal components of the reference image and relate to scene brightness, percent foliage projective cover (FPC) and water related features. The remaining three principal components, of diminishing significance with respect to the reference image, complete the set. The reference landscape, a 2200 km2 area containing a mix of cattle pasture, native woodland and forest, is located near Injune in South East Queensland, Australia. The indices developed from the reference image were tested using TM spectral images from 19 regionally dispersed areas in Queensland, representative of dissimilar landscapes containing woody vegetation ranging from tall closed forest to low open woodland. Examples of image transformations and two-dimensional feature space plots are used to demonstrate image interpretations related to the first three indices. Coherent, sensible, interpretations of landscape features in images composed of the first three indices can be made in terms of brightness (red), foliage cover (green) and water (blue). A limited comparison is made with similar existing indices. The proposed greenness index was found to be very strongly related to FPC and insensitive to smoke. A novel Bayesian, bounded space, modelling method, was used to validate the greenness index as a good predictor of FPC. Airborne LiDAR (Light Detection and Ranging) estimates of FPC along transects of the 19 sites provided the training and validation data. Other spectral indices from the set were found to be useful as model covariates that could improve FPC predictions. They act to adjust the greenness/FPC relationship to suit different spectral backgrounds. The inclusion of an external meteorological covariate showed that further improvements to regional-scale predictions of FPC could be gained over those based on spectral indices alone.
Resumo:
In recent times, light gauge cold-formed steel sections have been used extensively as primary load bearing structural members in many applications in the building industry. Fire safety design of structures using such sections has therefore become more important. Deterioration of mechanical properties of yield stress and elasticity modulus is considered the most important factor affecting the performance of steel structures in fires. Hence there is a need to fully understand the mechanical properties of light gauge cold-formed steels at elevated temperatures. A research project based on experimental studies was therefore undertaken to investigate the deterioration of mechanical properties of light gauge cold-formed steels. Tensile coupon tests were undertaken to determine the mechanical properties of these steels made of both low and high strength steels and thicknesses of 0.60, 0.80 and 0.95 mm at temperatures ranging from 20 to 800ºC. Test results showed that the currently available reduction factors are unsafe to use in the fire safety design of cold-formed steel structures. Therefore new predictive equations were developed for the mechanical properties of yield strength and elasticity modulus at elevated temperatures. This paper presents the details of the experimental study, and the results including the developed equations. It also includes details of a stress-strain model for light gauge cold-formed steels at elevated temperatures.
Resumo:
Fire design is an essential element of the overall design procedure of structural steel members and systems. Conventionally the fire rating of load-bearing stud wall systems made of light gauge steel frames (LSF) is based on approximate prescriptive methods developed on the basis of limited fire tests. This design is limited to standard wall configurations used by the industry. Increased fire rating is provided simply by adding more plasterboards to the stud walls. This is not an acceptable situation as it not only inhibits innovation and structural and cost efficiencies but also casts doubt over the fire safety of these light gauge steel stud wall systems. Hence a detailed fire research study into the performance and effectiveness of a recently developed innovative composite panel wall system was undertaken at Queensland University of Technology using both full scale fire tests and numerical studies. Experimental results of LSF walls using the new composite panels under axial compression load have shown the improvement in fire performance and fire resistance rating. Numerical analyses are currently being undertaken using the finite element program ABAQUS. Measured temperature profiles of the studs are used in the numerical models and the results are used to calibrate against full scale test results. The validated model will be used in a detailed parametric study with an aim to develop suitable design rules within the current cold-formed steel structures and fire design standards. This paper will present the results of experimental and numerical investigations into the structural and fire behaviour of light gauge steel stud walls protected by the new composite panel. It will demonstrate the improvements provided by the new composite panel system in comparison to traditional wall systems.