415 resultados para Clinical performance

em Queensland University of Technology - ePrints Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: Silicone hydrogel contact lenses (CLs) are becoming increasingly popular for daily wear (DW), extended wear (EW) and continuous wear (CW), due to their higher oxygen transmissibility compared to hydrogel CLs. The aim of this study was to investigate the clinical and subjective performance of asmofilcon A (Menicon Co., Ltd), a new surface treated silicone hydrogel CL, during 6-night EW over 6 months (M). Methods: A prospective, randomised, single-masked, monadic study was conducted. N=60 experienced DW soft CL wearers were randomly assigned to wear either asmofilcon A (test: Dk=129, water content (WC)=40%, Nanogloss surface treatment) or senofilcon A (control: Dk=103, WC=38%, PVP internal wetting agent, Vistakon, Johnson & Johnson Vision Care) CLs bilaterally for 6 M on an EW basis. A PHMB-preserved solution (Menicon Co., Ltd) was dispensed for CL care. Evaluations were conducted at CL delivery and after 1 week (W), 4 W, 3 M and 6 M of EW. At each visit, a range of objective and subjective clinical performance measures were assessed. Results: N=50 subjects (83%) successfully completed the study, with the majority of discontinuations due to loss to follow-up (n=3) or moving away/travel (n=5). N=2 subjects experienced adverse events; n=1 unilateral red eye with asmofilcon A and n=1 asymptomatic infiltrate with senofilcon A. There were no significant differences in high or low contrast distance visual acuity (HCDVA or LCDVA) between asmofilcon A and senofilcon A; however, LCDVA decreased significantly over time with both CL types (p<0.05). The two CL types did not vary significantly with respect to any of the objective and subjective measures assessed (p>0.05); CL fitting characteristics and CL surface measurements were very similar and mean bulbar and limbal redness measures were always less than grade 1.0. Superior palpebral conjunctival injection showed a statistically, but not clinically, significant increase over time with both CL types (p<0.05). Corneal staining did not vary significantly between asmofilcon A and senofilcon A (p>0.05), with low median gradings of less than 0.5 observed for all areas assessed. There were no solution-related staining reactions observed with either CL type. The asmofilcon A and senofilcon A CLs were both rated highly with respect to overall comfort, with medians of 14 or 15 hours of comfortable lens wearing time per day reported at each of the study visits (p>0.05). Conclusions: Over 6 months of EW, the asmofilcon A and senofilcon A CLs performed in a similar manner with respect to visual acuity, ocular health and CL performance measures. Some changes over time were observed with both CL types, including reduced LCDVA and increased superior palpebral injection, which warrant further investigation in longer-term EW studies. Asmofilcon A appeared to be equivalent in performance to senofilcon A.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To evaluate the feasibility, reliability and acceptability of the mini clinical evaluation exercise (mini-CEX) for performance assessment among international medical graduates (IMGs). Design, setting and participants: Observational study of 209 patient encounters involving 28 IMGs and 35 examiners at three metropolitan teaching hospitals in New South Wales, Victoria and Queensland, September-December 2006. Main outcome measures: The reliability of the mini-CEX was estimated using generatisability (G) analysis, and its acceptability was evaluated by a written survey of the examiners and IMGs. Results: The G coefficient for eight encounters was 0.88, suggesting that the reliability of the mini-CEX was 0.90 for 10 encounters. Almost half of the IMGs (7/16) and most examiners (14/18) were satisfied with the mini-CEX as a learning tool. Most of the IMGs and examiners enjoyed the immediate feedback, which is a strong component of the tool. Conclusion: The mini-CEX is a reliable tool for performance assessment of IMGs, and is acceptable to and well received by both learners and supervisors.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction The purpose of this study was to develop, implement and evaluate the impact of an educational intervention, comprising an innovative model of clinical decisionmaking and educational delivery strategy for facilitating nursing students‘ learning and development of competence in paediatric physical assessment practices. Background of the study Nursing students have an undergraduate education that aims to produce graduates of a generalist nature who demonstrate entry level competence for providing nursing care in a variety of health settings. Consistent with population morbidity and health care roles, paediatric nursing concepts typically form a comparatively small part of undergraduate curricula and students‘ exposure to paediatric physical assessment concepts and principles are brief. However, the nursing shortage has changed traditional nursing employment patterns and new graduates form the majority of the recruitment pool for paediatric nursing speciality staff. Paediatric nursing is a popular career choice for graduates and anecdotal evidence suggests that nursing students who select a clinical placement in their final year intend to seek employment in paediatrics upon graduation. Although concepts of paediatric nursing are included within undergraduate curriculum, students‘ ability to develop the required habits of mind to practice in what is still regarded as a speciality area of practice is somewhat limited. One of the areas of practice where this particularly impacts is in paediatric nursing physical assessment. Physical assessment is a fundamental component of nursing practice and competence in this area of practice is central to nursing students‘ development of clinical capability for practice as a registered nurse. Timely recognition of physiologic deterioration of patients is a key outcome of nurses‘ competent use of physical assessment strategies, regardless of the practice context. In paediatric nursing contexts children‘s physical assessment practices must specifically accommodate the child‘s different physiological composition, function and pattern of clinical deterioration (Hockenberry & Barrera, 2007). Thus, to effectively manage physical assessment of patients within the paediatric practice setting nursing students need to integrate paediatric nursing theory into their practice. This requires significant information processing and it is in this process where students are frequently challenged. The provision of rules or models can guide practice and assist novice-level nurses to develop their capabilities (Benner, 1984; Benner, Hooper-Kyriakidis & Stannard, 1999). Nursing practice models are cognitive tools that represent simplified patterns of expert analysis employing concepts that suit the limited reasoning of the inexperienced, and can represent the =rules‘ referred to by Benner (1984). Without a practice model of physical assessment students are likely to be uncertain about how to proceed with data collection, the interpretation of paediatric clinical findings and the appraisal of findings. These circumstances can result in ad hoc and unreliable nursing physical assessment that forms a poor basis for nursing decisions. The educational intervention developed as part of this study sought to resolve this problem and support nursing students‘ development of competence in paediatric physical assessment. Methods This study utilised the Context Input Process Product (CIPP) Model by Stufflebeam (2004) as the theoretical framework that underpinned the research design and evaluation methodology. Each of the four elements in the CIPP model were utilised to guide discrete stages of this study. The Context element informed design of the clinical decision-making process, the Paediatric Nursing Physical Assessment model. The Input element was utilised in appraising relevant literature, identifying an appropriate instructional methodology to facilitate learning and educational intervention delivery to undergraduate nursing students, and development of program content (the CD-ROM kit). Study One employed the Process element and used expert panel approaches to review and refine instructional methods, identifying potential barriers to obtaining an effective evaluation outcome. The Product element guided design and implementation of Study Two, which was conducted in two phases. Phase One employed a quasiexperimental between-subjects methodology to evaluate the impact of the educational intervention on nursing students‘ clinical performance and selfappraisal of practices in paediatric physical assessment. Phase Two employed a thematic analysis and explored the experiences and perspectives of a sample subgroup of nursing students who used the PNPA CD-ROM kit as preparation for paediatric clinical placement. Results Results from the Process review in Study One indicated that the prototype CDROM kit containing the PNPA model met the predetermined benchmarks for face validity and the impact evaluation instrumentation had adequate content validity in comparison with predetermined benchmarks. In the first phase of Study Two the educational intervention did not result in statistically significant differences in measures of student performance or self-appraisal of practice. However, in Phase Two qualitative commentary from students, and from the expert panel who reviewed the prototype CD-ROM kit (Study One, Phase One), strongly endorsed the quality of the intervention and its potential for supporting learning. This raises questions regarding transfer of learning and it is likely that, within this study, several factors have influenced students‘ transfer of learning from the educational intervention to the clinical practice environment, where outcomes were measured. Conclusion In summary, the educational intervention employed in this study provides insights into the potential e-learning approaches offer for delivering authentic learning experiences to undergraduate nursing students. Findings in this study raise important questions regarding possible pedagogical influences on learning outcomes, issues within the transfer of theory to practice and factors that may have influenced findings within the context of this study. This study makes a unique contribution to nursing education, specifically with respect to progressing an understanding of the challenges faced in employing instructive methods to impact upon nursing students‘ development of competence. The important contribution transfer of learning processes make to students‘ transition into the professional practice context and to their development of competence within the context of speciality practice is also highlighted. This study contributes to a greater awareness of the complexity of translating theoretical learning at undergraduate level into clinical practice, particularly within speciality contexts.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background Total hip arthroplasty carried out using cemented modular-neck implants provides the surgeon with greater intra-operative flexibility and allows more controlled stem positioning. Methods In this study, finite element models of a whole femur implanted with either the Exeter or with a new cemented modular-neck total hip arthroplasty (separate, neck and stem components) were developed. The changes in bone and cement mantle stress/strain were assessed for varying amounts of neck offset and version angle for the modular-neck device for two simulated physiological load cases: walking and stair climbing. Since the Exeter is the gold standard for polished cemented total hip arthroplasty stem design, bone and cement mantle stresses/strains in the modular-neck finite element models were compared with finite element results for the Exeter. Findings For the two physiological load cases, stresses and strains in the bone and cement mantle were similar for all modular-neck geometries. These results were comparable to the bone and cement mechanics surrounding the Exeter. These findings suggest that the Exeter and the modular neck device distribute stress to the surrounding bone and cement in a similar manner. Interpretation It is anticipated that the modular-neck device will have a similar short-term clinical performance to that of the Exeter, with the additional advantages of increased modularity.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The use of professional competency standards to assess postgraduate nursing student’s clinical performance has been in place since 2004, at the Queensland University of Technology, School of Nursing & Midwifery (SONAM) when the Graduate Certificate in Emergency Nursing degree commenced. Emergency nursing students were assessed in their workplace, using a Clinical Performance Appraisal Tool or CPAT which was based on the Australian College of Critical Care Nurses (ACCCN) Competency Standards. With the subsequent formation of a separate Emergency Nursing Course advisory group in 2007, there was a review of clinical assessment course component. The release of the 2008 CENA revised Practice Standards for the Emergency Nursing Specialist’s, led to the emergency nursing course advisory committee supporting the integration of the CENA practice standards for assessment of emergency nurses in preference to the less relevant ACCCN competency standards. The SONAM emergency nursing study area team commenced the phasing in and progression of the CENA practice standards across the two Graduate Certificate units, and Graduate Diploma and Master of Nursing (emergency) clinical major options in 2009. As some units undertaken in the degree are available to nurses in other disciplines a separate CPAT was devised for the clinical assessments according to speciality context. The team has had to carefully consider how the professional standards are integrated into the teaching and assessment of the unit and not just applied instead of the ACCCN competency standards. Professional standards for the emergency context has also helped tailor course content and learning outcomes to be relevant across a number of emergency nursing contexts in Australia. The assessment of the CPAT is undertaken at the workplace by QUT appointed clinical lecturers. Clinical lecturers need to apply and have suitable postgraduate qualification to undertake the position. The clinical lecturer support role is well established at QUT. The integration of the new CENA practice standards has necessitated a review of the postgraduate assessment of emergency nurses. A clinical lecturer workshop has been organised to review role, scope and how to utilise the new look CENA based CPAT, clinical assessment format.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Total hip arthroplasty (THA) has a proven clinical record for providing pain relief and return of function to patients with disabling arthritis. There are many successful options for femoral implant design and fixation. Cemented, polished, tapered femoral implants have been shown to have excellent results in national joint registries and long-term clinical series. These implants are usually 150mm long at their lateral aspect. Due to their length, these implants cannot always be offered to patients due to variations in femoral anatomy. Polished, tapered implants as short as 95mm exist, however their small proximal geometry (neck offset and body size) limit their use to smaller stature patients. There is a group of patients in which a shorter implant with a maintained proximal body size would be advantageous. There are also potential benefits to a shorter implant in standard patient populations such as reduced bone removal due to reduced reaming, favourable loading of the proximal femur, and the ability to revise into good proximal bone stock if required. These factors potentially make a shorter implant an option for all patient populations. The role of implant length in determining the stability of a cemented, polished, tapered femoral implant is not well defined by the literature. Before changes in implant design can be made, a better understanding of the role of each region in determining performance is required. The aim of the thesis was to describe how implant length affects the stability of a cemented, polished, tapered femoral implant. This has been determined through an extensive body of laboratory testing. The major findings are that for a given proximal body size, a reduction in implant length has no effect on the torsional stability of a polished, tapered design, while a small reduction in axial stability should be expected. These findings are important because the literature suggests that torsional stability is the major determinant of long-term clinical performance of a THA system. Furthermore, a polished, tapered design is known to be forgiving of cement-implant interface micromotion due to the favourable wear characteristics. Together these findings suggest that a shorter polished, tapered implant may be well tolerated. The effect of a change in implant length on the geometric characteristics of polished, tapered design were also determined and applied to the mechanical testing. Importantly, interface area does play a role in stability of the system; however it is the distribution of the interface and not the magnitude of the area that defines stability. Taper angle (at least in the range of angles seen in this work) was shown not to be a determinant of axial or torsional stability. A range of implants were tested, comparing variations in length, neck offset and indication (primary versus cement-in-cement revision). At their manufactured length, the 125mm implants were similar to their longer 150mm counterparts suggesting that they may be similarly well tolerated in the clinical environment. However, the slimmer cement-in-cement revision implant was shown to have a poorer mechanical performance, suggesting their use in higher demand patients may be hazardous. An implant length of 125mm has been shown to be quite stable and the results suggest that a further reduction to 100mm may be tolerated. However, further work is required. A shorter implant with maintained proximal body size would be useful for the group of patients who are unable to access the current standard length implants due to variations in femoral anatomy. Extending the findings further, the similar function with potential benefits of a shorter implant make their application to all patients appealing.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: To describe patient participation and clinical performance in a colorectal cancer (CRC) screening program utilising faecal occult blood test (FOBT). Methods: A community-based intervention was conducted in a small, rural community in north Queensland, 2000/01. One of two FOBT kits – guaiac (Hemoccult-ll) or immunochemical (Inform) – was assigned by general practice and mailed to participants (3,358 patients aged 50–74 years listed with the local practices). Results: Overall participation in FOBT screening was 36.3%. Participation was higher with the immunochemical kit than the guaiac kit (OR=1.9, 95% Cl 1.6-2.2). Women were more likely to comply with testing than men (OR=1.4, 95% Cl 1.2-1.7), and people in their 60s were less likely to participate than those 70–74 years (OR=0.8, 95% Cl 0.6-0.9). The positivity rate was higher for the immunochemical (9.5%) than the guaiac (3.9%) test (χ2=9.2, p=0.002), with positive predictive values for cancer or adenoma of advanced pathology of 37.8% (95% Cl 28.1–48.6) for !nform and 40.0% (95% Cl 16.8–68.7) for Hemoccult-ll. Colonoscopy follow-up was 94.8% with a medical complication rate of 2–3%. Conclusions: An immunochemical FOBT enhanced participation. Higher positivity rates for this kit did not translate into higher false-positive rates, and both test types resulted in a high yield of neoplasia. Implications: In addition to type of FOBT, the ultimate success of a population-based screening program for CRC using FOBT will depend on appropriate education of health professionals and the public as well as significant investment in medical infrastructure for colonoscopy follow-up.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective To compare the diagnostic accuracy of the interRAI Acute Care (AC) Cognitive Performance Scale (CPS2) and the Mini-Mental State Examination (MMSE), against independent clinical diagnosis for detecting dementia in older hospitalized patients. Design, Setting, and Participants The study was part of a prospective observational cohort study of patients aged ≥70 years admitted to four acute hospitals in Queensland, Australia, between 2008 and 2010. Recruitment was consecutive and patients expected to remain in hospital for ≥48 hours were eligible to participate. Data for 462 patients were available for this study. Measurements Trained research nurses completed comprehensive geriatric assessments and administered the interRAI AC and MMSE to patients. Two physicians independently reviewed patients’ medical records and assessments to establish the diagnosis of dementia. Indicators of diagnostic accuracy included sensitivity, specificity, predictive values, likelihood ratios and areas under receiver (AUC) operating characteristic curves. Results 85 patients (18.4%) were considered to have dementia according to independent clinical diagnosis. The sensitivity of the CPS2 [0.68 (95%CI: 0.58–0.77)] was not statistically different to the MMSE [0.75 (0.64–0.83)] in predicting physician diagnosed dementia. The AUCs for the 2 instruments were also not statistically different: CPS2 AUC = 0.83 (95%CI: 0.78–0.89) and MMSE AUC = 0.87 (95%CI: 0.83–0.91), while the CPS2 demonstrated higher specificity [0.92 95%CI: 0.89–0.95)] than the MMSE [0.82 (0.77–0.85)]. Agreement between the CPS2 and clinical diagnosis was substantial (87.4%; κ=0.61). Conclusion The CPS2 appears to be a reliable screening tool for assessing cognitive impairment in acutely unwell older hospitalized patients. These findings add to the growing body of evidence supporting the utility of the interRAI AC, within which the CPS2 is embedded. The interRAI AC offers the advantage of being able to accurately screen for both dementia and delirium without the need to use additional assessments, thus increasing assessment efficiency.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: Data from two randomized phase III trials were analyzed to evaluate prognostic factors and treatment selection in the first-line management of advanced non-small cell lung cancer patients with performance status (PS) 2. Patients and Methods: Patients randomized to combination chemotherapy (carboplatin and paclitaxel) in one trial and single-agent therapy (gemcitabine or vinorelbine) in the second were included in these analyses. Both studies had identical eligibility criteria and were conducted simultaneously. Comparison of efficacy and safety was performed between the two cohorts. A regression analysis identified prognostic factors and subgroups of patients that may benefit from combination or single-agent therapy. Results: Two hundred one patients were treated with combination and 190 with single-agent therapy. Objective responses were 37 and 15%, respectively. Median time to progression was 4.6 months in the combination arm and 3.5 months in the single-agent arm (p < 0.001). Median survival imes were 8.0 and 6.6 months, and 1-year survival rates were 31 and 26%, respectively. Albumin <3.5 g, extrathoracic metastases, lactate dehydrogenase ≥200 IU, and 2 comorbid conditions predicted outcome. Patients with 0-2 risk factors had similar outcomes independent of treatment, whereas patients with 3-4 factors had a nonsignificant improvement in median survival with combination chemotherapy. Conclusion: Our results show that PS2 non-small cell lung cancer patients are a heterogeneous group who have significantly different outcomes. Patients treated with first-line combination chemotherapy had a higher response and longer time to progression, whereas overall survival did not appear significantly different. A prognostic model may be helpful in selecting PS 2 patients for either treatment strategy. © 2009 by the International Association for the Study of Lung Cancer.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background A goal of the postgraduate clinical pharmacy programme (PGCPP) at the University of Queensland is to enhance clinical practice. Aims To evaluate student perceptions of the impact of the PGCPP on practice and the inclusion of a competency-based performance evaluation as a formative component of the curriculum. Method In 2010, students completed a questionnaire to evaluate the impact of the PGCPP. In 2011, formative competency-based performance evaluations were conducted as a component of the course and the questionnaire was repeated. Responses, competency ratings and evaluation feedback were collated. Data were analysed using descriptive statistics. Results 51/57 (89%) of students completed the questionnaire in 2010 and 2011. Over 90% of students agreed or strongly agreed that the PGCPP enhanced practice, knowledge, confidence and contribution to patient care. Responses were similarly positive after the inclusion of the performance evaluation. Conclusion This study demonstrated that the PGCPP is achieving the goal of enhancing the practice of pharmacists.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: Optometry students are taught the process of subjective refraction through lectures and laboratory based practicals before progressing to supervised clinical practice. Simulated learning environments (SLEs) are an emerging technology that are used in a range of health disciplines, however, there is limited evidence regarding the effectiveness of clinical simulators as an educational tool. Methods: Forty optometry students (20 fourth year and 20 fifth year) were assessed twice by a qualified optometrist (two examinations separated by 4-8 weeks) while completing a monocular non-cycloplegic subjective refraction on the same patient with an unknown refractive error simulated using contact lenses. Half of the students were granted access to an online SLE, The Brien Holden Vision Institute (BHVI®) Virtual Refractor, and the remaining students formed a control group. The primary outcome measures at each visit were; accuracy of the clinical refraction compared to a qualified optometrist and relative to the Optometry Council of Australia and New Zealand (OCANZ) subjective refraction examination criteria. Secondary measures of interest included descriptors of student SLE engagement, student self-reported confidence levels and correlations between performance in the simulated and real world clinical environment. Results: Eighty percent of students in the intervention group interacted with the SLE (for an average of 100 minutes); however, there was no correlation between measures of student engagement with the BHVI® Virtual Refractor and speed or accuracy of clinical subjective refractions. Fifth year students were typically more confident and refracted more accurately and quickly than fourth year students. A year group by experimental group interaction (p = 0.03) was observed for accuracy of the spherical component of refraction, and post hoc analysis revealed that less experienced students exhibited greater gains in clinical accuracy following exposure to the SLE intervention. Conclusions: Short-term exposure to a SLE can positively influence clinical subjective refraction outcomes for less experienced optometry students and may be of benefit in increasing the skills of novice refractionists to levels appropriate for commencing supervised clinical interactions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Poor workplace relations are an issue of concern in many workplaces and this phenomenon is not restricted to the nursing profession. The issue of workplace violence in nursing is well documented and there are an increasing number of studies which have investigated the notion of horizontal violence amongst graduate nurses. The impact that poor workplace relations has on the development of a professional identity by nursing students in the off-campus clinical setting is significant in light of the current global shortage of nurses. There is a dearth of knowledge in understanding how Australian undergraduate nursing students experience the off-campus clinical setting and subsequently develop a professional identity as a nurse. Therefore the aim of this study was to discover and describe the phenomena in order to develop a substantive theory that explains the experiences of the undergraduate nursing students in a regional setting. Constructivist grounded theory methods were utilised in the conduct of the study. A sample of 29 participants was recruited permitting the formulation of a substantive theory regarding the development of a professional identity in nursing students. This substantive theory contributes knowledge relevant to the undergraduate nursing students, nurse educators, nursing workforce planners, and the tertiary educational institutions offering nursing. This is achieved through discovering, describing and explaining the phenomenon of ‘anxiety’ which the nursing students experience as a result of the interrelationship and interactions of tradition bearing, staff and student performance. These interactions intersect to form expectations of where the student fits within the hierarchy of the facility and the nursing profession in general. An understanding of the issues associated with tradition bearing, staff performance, and student performance and the impact that the interaction of these conditions has upon the student’s developing professional identity as a nurse is necessary to allow for the implementation of corrective strategies.