125 resultados para Central fiber tracker (CFT)
em Queensland University of Technology - ePrints Archive
Resumo:
Purpose To compare small nerve fiber damage in the central cornea and whorl area in participants with diabetic peripheral neuropathy (DPN) and to examine the accuracy of evaluating these 2 anatomical sites for the diagnosis of DPN. Methods A cohort of 187 participants (107 with type 1 diabetes and 80 controls) was enrolled. The neuropathy disability score (NDS) was used for the identification of DPN. The corneal nerve fiber length at the central cornea (CNFLcenter) and whorl (CNFLwhorl) was quantified using corneal confocal microscopy and a fully automated morphometric technique and compared according to the DPN status. Receiver operating characteristic analyses were used to compare the accuracy of the 2 corneal locations for the diagnosis of DPN. Results CNFLcenter and CNFLwhorl were able to differentiate all 3 groups (diabetic participants with and without DPN and controls) (P < 0.001). There was a weak but significant linear relationship for CNFLcenter and CNFLwhorl versus NDS (P < 0.001); however, the corneal location x NDS interaction was not statistically significant (P = 0.17). The area under the receiver operating characteristic curve was similar for CNFLcenter and CNFLwhorl (0.76 and 0.77, respectively, P = 0.98). The sensitivity and specificity of the cutoff points were 0.9 and 0.5 for CNFLcenter and 0.8 and 0.6 for CNFLwhorl. Conclusions Small nerve fiber pathology is comparable at the central and whorl anatomical sites of the cornea. Quantification of CNFL from the corneal center is as accurate as CNFL quantification of the whorl area for the diagnosis of DPN.
Resumo:
Communication plays an important role in the development of trust within an organization. While a number of researchers have studied the relationship of trust and communication, little is known about the specific linkages among quality of information, quantity of information, openness, trust, and outcomes such as employee involvement. This study tests these relationships using communication audit data from 218 employees in the oil industry. Using mediation analysis and structural equation modeling, we found that quality of information predicted trust of one's coworkers and supervisors while adequacy of information predicted one's trust of top management. Trust of coworkers, supervisors, and top management influenced perceptions of organizational openness, which in turn influenced employees' ratings of their own level of involvement in the organization's goals. This study suggests that the relationship between communication and trust is complex, and that simple strategies focusing on either quality or quantity of information may be ineffective for dealing with all members in an organization.
Resumo:
This report reviews the selection, design, and installation of fiber reinforced polymer systems for strengthening of reinforced concrete or pre-stressed concrete bridges and other structures. The report is prepared based on the knowledge gained from worldwide experimental research, analytical work, and field applications of FRP systems used to strengthen concrete structures. Information on material properties, design and installation methods of FRP systems used as external reinforcement are presented. This information can be used to select an FRP system for increasing the strength and stiffness of reinforced concrete beams or the ductility of columns, and other applications. Based on the available research, the design considerations and concepts are covered in this report. In the next stage of the project, these will be further developed as design tools. It is important to note, however, that the design concepts proposed in literature have not in many cases been thoroughly developed and proven. Therefore, a considerable amount of research work will be required prior to development of the design concepts into practical design tools, which is a major goal of the current research project. The durability and long-term performance of FRP materials has been the subject of much research, which still are on going. Long-term field data are not currently available, and it is still difficult to accurately predict the life of FRP strengthening systems. The report briefly addresses environmental degradation and long-term durability issues as well. A general overview of using FRP bars as primary reinforcement of concrete structures is presented in Chapter 8. In Chapter 9, a summary of strengthening techniques identified as part of this initial stage of the research project and the issues which require careful consideration prior to practical implementation of these identified techniques are presented.
Resumo:
A worldwide interest is being generated in the use of fibre reinforced polymer composites (FRP) in rehabilitation of reinforced concrete structures. As a replacement for the traditional steel plates or external post-tensioning in strengthening applications, various types of FRP plates, with their high strength to weight ratio and good resistance to corrosion, represent a class of ideal material in external retrofitting. Within the last ten years, many design guidelines have been published to provide guidance for the selection, design and installation of FRP systems for external strengthening of concrete structures. Use of these guidelines requires understanding of a number of issues pertaining to different properties and structural failure modes specific to these materials. A research initiative funded by the CRC for Construction Innovation was undertaken (primarily at RMIT) to develop a decision support tool and a user friendly guide for use of fibre reinforced polymer composites in rehabilitation of concrete structures. The user guidelines presented in this report were developed after industry consultation and a comprehensive review of the state of the art technology. The scope of the guide was mainly developed based on outcomes of two workshops with Queensland Department of Main Roads (QDMR). The document covers material properties, recommended construction requirements, design philosophy, flexural, shear and torsional strengthening of beams and strengthening of columns. In developing this document, the guidelines published on FIB Bulletin 14 (2002), Task group 9.3, International Federation of Structural Concrete (FIB) and American Concrete Institute Committee 440 report (2002) were consulted in conjunction with provisions of the Austroads Bridge design code (1992) and Australian Concrete Structures code AS3600 (2002). In conclusion, the user guide presents design examples covering typical strengthening scenarios.
Resumo:
Searching for humans lost in vast stretches of ocean has always been a difficult task. This paper investigates a machine vision system that addresses this problem by exploiting the useful properties of alternate colour spaces. In particular, the paper investigates the fusion of colour information from the HSV, RGB, YCbCr and YIQ colour spaces within the emission matrix of a Hidden Markov Model tracker to enhance video based maritime target detection. The system has shown promising results. The paper also identifies challenges still needing to be met.
Resumo:
The Queensland Department of Public Works (DPW) holds a significant interest in the Brisbane Central Business District (CBD) in controlling approximately 20 percent of the office space within its confines. This comprises a total of 333,903 square metres of space, of which 170,111 square metres is owned and 163,792 square metres is leased from the private sector. The department’s nominal ownership extends to several enduring, landmark buildings as well as several modern office towers. The portfolio includes the oldest building in the CBD, being the former Commissariat Stores building and one of the newest, a 15,000 square metre office tower under construction at 33 Charlotte Street.
Resumo:
Computer aided joint replacement surgery has become very popular during recent years and is being done in increasing numbers all over the world. The accuracy of the system depends to a major extent, on accurate registration and immobility of the tracker attachment devices to the bone. This study was designed to asses the forces needed to displace the tracker attachment devices in the bone simulators. Bone simulators were used to maintain the uniformity of the bone structure during the study. The fixation devices tested were 3mm diameter self drilling, self tapping threaded pin, 4mm diameter self tapping cortical threaded pin, 5mm diameter self tapping cancellous threaded pin and a triplanar fixation device ‘ortholock’ used with three 3mm pins. All the devices were tested for pull out, translational and rotational forces in unicortical and bicortical fixation modes. Also tested was the normal bang strength and forces generated by leaning on the devices. The forces required to produce translation increased with the increasing diameter of the pins. These were 105N, 185N, and 225N for the unicortical fixations and 130N, 200N, 225N for the bicortical fixations for 3mm, 4mm and 5mm diameter pins respectively. The forces required to pull out the pins were 1475N, 1650N, 2050N for the unicortical, 1020N, 3044N and 3042N for the bicortical fixated 3mm, 4mm and 5mm diameter pins. The ortholock translational and pull out strength was tested to 900N and 920N respectively and still it did not fail. Rotatory forces required to displace the tracker on pins was to the magnitude of 30N before failure. The ortholock device had rotational forces applied up to 135N and still did not fail. The manual leaning forces and the sudden bang forces generated were of the magnitude of 210N and 150N respectively. The strength of the fixation pins increases with increasing diameter from three to five mm for the translational forces. There is no significant difference in pull out forces of four mm and five mm diameter pins though it is more that the three mm diameter pins. This is because of the failure of material at that stage rather than the fixation device. The rotatory forces required to displace the tracker are very small and much less that that can be produced by the surgeon or assistants in single pins. Although the ortholock device was tested to 135N in rotation without failing, one has to be very careful not to put any forces during the operation on the tracker devices to ensure the accuracy of the procedure.
Resumo:
Purpose: To determine the subbasal nerve density and tortuosity at 5 corneal locations and to investigate whether these microstructural observations correlate with corneal sensitivity. Method: Sixty eyes of 60 normal human subjects were recruited into 1 of 3 age groups, group 1: aged ,35 years, group 2: aged 35–50 years, and group 3: aged .50 years. All eyes were examined using slit-lamp biomicroscopy, noncontact corneal esthesiometry, and slit scanning in vivo confocal microscopy. Results: The mean subbasal nerve density and the mean corneal sensitivity were greatest centrally (14,731 6 6056 mm/mm2 and 0.38 6 0.21 millibars, respectively) and lowest in the nasal mid periphery (7850 6 4947 mm/mm2 and 0.49 6 0.25 millibars, respectively). The mean subbasal nerve tortuosity coefficient was greatest in the temporal mid periphery (27.3 6 6.4) and lowest in the superior mid periphery (19.3 6 14.1). There was no significant difference in mean total subbasal nerve density between age groups. However, corneal sensation (P = 0.001) and subbasal nerve tortuosity (P = 0.004) demonstrated significant differences between age groups. Subbasal nerve density only showed significant correlations with corneal sensitivity threshold in the temporal cornea and with subbasal nerve tortuosity in the inferior and nasal cornea. However, these correlations were weak. Conclusions: This study quantitatively analyzes living human corneal nerve structure and an aspect of nerve function. There is no strong correlation between subbasal nerve density and corneal sensation. This study provides useful baseline data for the normal living human cornea at central and mid-peripheral locations
Resumo:
It has been established that mixed venous oxygen saturation (SvO2) reflects the balance between systemic oxygen deliver y and consumption. Literature indicates that it is a valuable clinical indicator and has good prognostic value early in patient course. This article aims to establish the usefulness of SvO2 as a clinical indicator. A secondary aim was to determine whether central venous oxygen saturation (ScvO2) and SvO2 are interchangeable. Of particular relevance to cardiac nurses is the link between decreased SvO2 and cardiac failure in patients with myocardial infarction, and with decline in myocardial function, clinical shock and arrhythmias. While absolute values ScvO2 and SvO2 are not interchangeable, ScvO2 and SvO2are equivalent in terms of clinical course. Additionally, ScvO2 monitoring is a safer and less costly alternative to SvO2 monitoring. It can be concluded that continuous ScvO2 monitoring should potentially be undertaken in patients at risk of haemodynamic instability.
Resumo:
In this chapter I raise questions about the current scope and purpose of early childhood education for sustainability (ECEfS) and the ways ECEfS is enacted in practice. This is to highlight why social, political and economic areas of concern should be central in ECEfS alongside an environmental focus. Specifically, this chapter establishes the place of Reconciliation in ECEfS because it is one of the most pressing ethical, social, political and economic issues on the Australian landscape. To reposition an ethic of sustainability is to broaden the scope and purpose of sustainability work so that particular regard is given to the place of Reconciliation in ECEfS. An ethic of sustainability is also concerned with the responsibility of non-Indigenous educators to take ownership of Reconciliation work in education curricula and contexts.