80 resultados para Catheter Ablation

em Queensland University of Technology - ePrints Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Catheter ablation procedures for atrial fibrillation (AF) may frequently require long fluoroscopic times. We sought to undertake a review of radiation safety practice in our Cardiac Electrophysiology Laboratory and implement changes to minimize fluoroscopic doses. We also sought to compare the results with radiation doses for percutaneous coronary intervention (PCI) cases performed in our hospital. Methods: Fluoroscopic times and doses for AF ablation procedures performed by a single operator on a Philips Integris H3000 image-intensifier were analysed for 11-month period. Results were compared with all PCI procedures performed over a similar period by multiple operators on a Philips Integris Allura FD system. Comprehensive review of radiation practice in the Electrophysiology laboratory identified the potential to reduce pulse frame rates and doses, and to narrow the field of interest without impacting the performance of the procedure. These changes were implemented and results analysed after a further 11 months. Results: In the pre-intervention period 50 AF catheter ablations had a mean fluoroscopic time of 86.4 min and mean fluoroscopic dose 68.4 Gy/cm2. Post-intervention 75 procedures had a mean fluorosocopic time of 68.9 min (p < 0.0001) and mean dose of 14.3 Gy/cm2 (p < 0.0001) 128 PCI procedures had a mean combined fluoroscopic and image acquisition time of 10.0 min and mean total dose 38.8 Gy/cm2. Conclusions: Catheter ablation procedures for AF may require lengthy use of fluoroscopy but simple modifications to radiation practice can result in marked reductions in radiation dose that compare favourably with PCI case doses

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background: Catheter ablation for atrial fibrillation (AF) is more efficacious than antiarrhythmic therapy. Post ablation recurrences reduce ablation effectiveness and are contributed by lesion discontinuity in the fibrotic linear ablation lesions. The anti-fibrotic role of statins in reducing AF is being assessed in current trials. By reducing the chronic pathological fibrosis that occurs in AF they may reduce AF. However if statins also have an effect on the acute therapeutic fibrosis of an ablation, this could exacerbate lesion discontinuity and AF recurrence. We tested the hypothesis that statins attenuate ablation lesion continuity in a recognised pig atrial linear ablation model. Aims: To assess whether Atorvastatin diminishes the bi-directional conduction block produced by a linear atrial ablation lesion. Methods: Sixteen pigs were randomised to statin (n=8) or placebo (n=8) with drug pre-treatment for 3 days and a further 4 weeks. At initial electrophysiological study (EPS1) 3D right atrium (RA) mapping and a vertical ablation linear lesion in the posterior RA with bidirectional conduction block were completed (Gepstein Circ 1999). Follow-up electrophysiological assessment (EPS2) at 28 days assessed bidirectional conduction block maintenance. Results: Data of 15/16 (statin=7) pigs were analysed. Mean lesion length was 3.7 ± 0.8cm with a mean of 17.9 ± 5.7 lesion applications. Bi-directional conduction block was confirmed in 15/15 pigs (100%) at EPS1 and EPS2. Conclusions: Atorvastatin did not affect ablation lesion continuity in this pig atrial linear ablation model. If patients are on long-term statins for AF reduction, periablation cessation is probably not necessary.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

[Letter to the Editor] I read with great interest the article recently published in the Journal of PeriAnesthesia Nursing that examined the utility of using dexmedetomidine (DEX) as an adjunct to midazolam and fentanyl for procedural sedation and analgesia during radiofrequency catheter ablation (RFCA) of atrial fibrillation (AF).1 With the view toward advancing knowledge about more effective medications for sedation in this challenging context, I offer the following insights for readers to consider regarding this study...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Catheter-related bloodstream infections are a serious problem. Many interventions reduce risk, and some have been evaluated in cost-effectiveness studies. We review the usefulness and quality of these economic studies. Evidence is incomplete, and data required to inform a coherent policy are missing. The cost-effectiveness studies are characterized by a lack of transparency, short time-horizons, and narrow economic perspectives. Data quality is low for some important model parameters. Authors of future economic evaluations should aim to model the complete policy and not just single interventions. They should be rigorous in developing the structure of the economic model, include all relevant economic outcomes, use a systematic approach for selecting data sources for model parameters, and propagate the effect of uncertainty in model parameters on conclusions. This will inform future data collection and improve our understanding of the economics of preventing these infections.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background The accurate measurement of Cardiac output (CO) is vital in guiding the treatment of critically ill patients. Invasive or minimally invasive measurement of CO is not without inherent risks to the patient. Skilled Intensive Care Unit (ICU) nursing staff are in an ideal position to assess changes in CO following therapeutic measures. The USCOM (Ultrasonic Cardiac Output Monitor) device is a non-invasive CO monitor whose clinical utility and ease of use requires testing. Objectives To compare cardiac output measurement using a non-invasive ultrasonic device (USCOM) operated by a non-echocardiograhically trained ICU Registered Nurse (RN), with the conventional pulmonary artery catheter (PAC) using both thermodilution and Fick methods. Design Prospective observational study. Setting and participants Between April 2006 and March 2007, we evaluated 30 spontaneously breathing patients requiring PAC for assessment of heart failure and/or pulmonary hypertension at a tertiary level cardiothoracic hospital. Methods SCOM CO was compared with thermodilution measurements via PAC and CO estimated using a modified Fick equation. This catheter was inserted by a medical officer, and all USCOM measurements by a senior ICU nurse. Mean values, bias and precision, and mean percentage difference between measures were determined to compare methods. The Intra-Class Correlation statistic was also used to assess agreement. The USCOM time to measure was recorded to assess the learning curve for USCOM use performed by an ICU RN and a line of best fit demonstrated to describe the operator learning curve. Results In 24 of 30 (80%) patients studied, CO measures were obtained. In 6 of 30 (20%) patients, an adequate USCOM signal was not achieved. The mean difference (±standard deviation) between USCOM and PAC, USCOM and Fick, and Fick and PAC CO were small, −0.34 ± 0.52 L/min, −0.33 ± 0.90 L/min and −0.25 ± 0.63 L/min respectively across a range of outputs from 2.6 L/min to 7.2 L/min. The percent limits of agreement (LOA) for all measures were −34.6% to 17.8% for USCOM and PAC, −49.8% to 34.1% for USCOM and Fick and −36.4% to 23.7% for PAC and Fick. Signal acquisition time reduced on average by 0.6 min per measure to less than 10 min at the end of the study. Conclusions In 80% of our cohort, USCOM, PAC and Fick measures of CO all showed clinically acceptable agreement and the learning curve for operation of the non-invasive USCOM device by an ICU RN was found to be satisfactorily short. Further work is required in patients receiving positive pressure ventilation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: A bundled approach to central venous catheter care is currently being promoted as an effective way of preventing catheter-related bloodstream infection (CR-BSI). Consumables used in the bundled approach are relatively inexpensive which may lead to the conclusion that the bundle is cost-effective. However, this fails to consider the nontrivial costs of the monitoring and education activities required to implement the bundle, or that alternative strategies are available to prevent CR-BSI. We evaluated the cost-effectiveness of a bundle to prevent CR-BSI in Australian intensive care patients. ---------- Methods and Findings: A Markov decision model was used to evaluate the cost-effectiveness of the bundle relative to remaining with current practice (a non-bundled approach to catheter care and uncoated catheters), or use of antimicrobial catheters. We assumed the bundle reduced relative risk of CR-BSI to 0.34. Given uncertainty about the cost of the bundle, threshold analyses were used to determine the maximum cost at which the bundle remained cost-effective relative to the other approaches to infection control. Sensitivity analyses explored how this threshold alters under different assumptions about the economic value placed on bed-days and health benefits gained by preventing infection. If clinicians are prepared to use antimicrobial catheters, the bundle is cost-effective if national 18-month implementation costs are below $1.1 million. If antimicrobial catheters are not an option the bundle must cost less than $4.3 million. If decision makers are only interested in obtaining cash-savings for the unit, and place no economic value on either the bed-days or the health benefits gained through preventing infection, these cost thresholds are reduced by two-thirds.---------- Conclusions: A catheter care bundle has the potential to be cost-effective in the Australian intensive care setting. Rather than anticipating cash-savings from this intervention, decision makers must be prepared to invest resources in infection control to see efficiency improvements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A detailed study of the Bjurbole fusion crust using scanning electron microscopy (SEM) and energy dispersive analysis (EDS) shows that filamentary crystals and ablation spheres may form on the meteoroid surface. Filamentary crystals, hollow spheres, and porous regions of the surface point to a period of intense vapor phase activity during atmospheric passage. Filamentary crystals can be divided into three categories on the basis of bulk composition and morphology. Two types of filamentary crystals are vapor phase condensation products formed during atmospheric entry of the meteoroid. The other type forms by the interaction of seawater with the fusion surface. The density and composition of ablation spheres varies with the flight orientation of the meteorite. The size range and composition of iron-nickel spheres on the surface of Bjurbole are similar to spheres collected in the stratosphere. A comparison of stratospheric dust collections with meteorite surfaces may provide further insight into the mechanisms of meteoroid entry into planetary atmospheres.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To identify and appraise the literature concerning nurse-administered procedural sedation and analgesia in the cardiac catheter laboratory. Design and data sources: An integrative review method was chosen for this study. MEDLINE and CINAHL databases as well as The Cochrane Database of Systematic Reviews and the Joanna Briggs Institute were searched. Nineteen research articles and three clinical guidelines were identified. Results: The authors of each study reported nurse-administered sedation in the CCL is safe due to the low incidence of complications. However, a higher percentage of deeply sedated patients were reported to experience complications than moderately sedated patients. To confound this issue, one clinical guideline permits deep sedation without an anaesthetist present, while others recommend against it. All clinical guidelines recommend nurses are educated about sedation concepts. Other findings focus on pain and discomfort and the cost-savings of nurse-administered sedation, which are associated with forgoing anaesthetic services. Conclusions: Practice is varied due to limitations in the evidence and inconsistent clinical practice guidelines. Therefore, recommendations for research and practice have been made. Research topics include determining how and in which circumstances capnography can be used in the CCL, discerning the economic impact of sedation-related complications and developing a set of objectives for nursing education about sedation. For practice, if deep sedation is administered without an anaesthetist present, it is essential nurses are adequately trained and have access to vital equipment such as capnography to monitor ventilation because deeply sedated patients are more likely to experience complications related to sedation. These initiatives will go some way to ensuring patients receiving nurse-administered procedural sedation and analgesia for a procedure in the cardiac catheter laboratory are cared for using consistent, safe and evidence-based practices.