492 resultados para CONTACT PRESSURE EVOLUTION
em Queensland University of Technology - ePrints Archive
Resumo:
Rail joints are provided with a gap to account for thermal movement and to maintain electrical insulation for the control of signals and/or broken rail detection circuits. The gap in the rail joint is regarded as a source of significant problems for the rail industry since it leads to a very short rail service life compared with other track components due to the various, and difficult to predict, failure modes – thus increasing the risk for train operations. Many attempts to improve the life of rail joints have led to a large number of patents around the world; notable attempts include strengthening through larger-sized joint bars, an increased number of bolts and the use of high yield materials. Unfortunately, no design to date has shown the ability to prolong the life of the rail joints to values close to those for continuously welded rail (CWR). This paper reports the results of a fundamental study that has revealed that the wheel contact at the free edge of the railhead is a major problem since it generates a singularity in the contact pressure and railhead stresses. A design was therefore developed using an optimisation framework that prevents wheel contact at the railhead edge. Finite element modelling of the design has shown that the contact pressure and railhead stress singularities are eliminated, thus increasing the potential to work as effectively as a CWR that does not have a geometric gap. An experimental validation of the finite element results is presented through an innovative non-contact measurement of strains. Some practical issues related to grinding rails to the optimal design are also discussed.
Resumo:
Proper functioning of Insulated Rail Joints (IRJs) is essential for the safe operation of the railway signalling systems and broken rail identification circuitries. The Conventional IRJ (CIRJ) resembles structural butt joints consisting of two pieces of rails connected together through two joint bars on either side of their web and the assembly is held together through pre-tensioned bolts. As the IRJs should maintain electrical insulation between the two rails, a gap between the rail ends must be retained at all times and all metal contacting surfaces should be electrically isolated from each other using non-conductive material. At the gap, the rail ends lose longitudinal continuity and hence the vertical sections of the rail ends are often severely damaged, especially at the railhead, due to the passage of wheels compared to other continuously welded rail sections. Fundamentally, the reason for the severe damage can be related to the singularities of the wheel-rail contact pressure and the railhead stress. No new generation designs that have emerged in the market to date have focussed on this fundamental; they only have provided attention to either the higher strength materials or the thickness of the sections of various components of the IRJs. In this thesis a novel method of shape optimisation of the railhead is developed to eliminate the pressure and stress singularities through changes to the original sharp corner shaped railhead into an arc profile in the longitudinal direction. The optimal shape of the longitudinal railhead profile has been determined using three nongradient methods in search of accuracy and efficiency: (1) Grid Search Method; (2) Genetic Algorithm Method and (3) Hybrid Genetic Algorithm Method. All these methods have been coupled with a parametric finite element formulation for the evaluation of the objective function for each iteration or generation depending on the search algorithm employed. The optimal shape derived from these optimisation methods is termed as Stress Minimised Railhead (SMRH) in this thesis. This optimal SMRH design has exhibited significantly reduced stress concentration that remains well below the yield strength of the head hardened rail steels and has shifted the stress concentration location away from the critical zone of the railhead end. The reduction in the magnitude and the relocation of the stress concentration in the SMRH design has been validated through a full scale wheel – railhead interaction test rig; Railhead strains under the loaded wheels have been recorded using a non-contact digital image correlation method. Experimental study has confirmed the accuracy of the numerical predications. Although the SMRH shaped IRJs eliminate stress singularities, they can still fail due to joint bar or bolt hole cracking; therefore, another conceptual design, termed as Embedded IRJ (EIRJ) in this thesis, with no joint bars and pre-tensioned bolts has been developed using a multi-objective optimisation formulation based on the coupled genetic algorithm – parametric finite element method. To achieve the required structural stiffness for the safe passage of the loaded wheels, the rails were embedded into the concrete of the post tensioned sleepers; the optimal solutions for the design of the EIRJ is shown to simplify the design through the elimination of the complex interactions and failure modes of the various structural components of the CIRJ. The practical applicability of the optimal shapes SMRH and EIRJ is demonstrated through two illustrative examples, termed as improved designs (IMD1 & IMD2) in this thesis; IMD1 is a combination of the CIRJ and the SMRH designs, whilst IMD2 is a combination of the EIRJ and SMRH designs. These two improved designs have been simulated for two key operating (speed and wagon load) and design (wheel diameter) parameters that affect the wheel-rail contact; the effect of these parameters has been found to be negligible to the performance of the two improved designs and the improved designs are in turn found far superior to the current designs of the CIRJs in terms of stress singularities and deformation under the passage of the loaded wheels. Therefore, these improved designs are expected to provide longer service life in relation to the CIRJs.
Resumo:
Numerous Abaqus [1] finite element analyses have been carried out using various plasticity models to investigate the effect of friction force on the rail head in relation to both the development of the accumulated plastic strain (PEEQ) and the changes in the depth of PEEQ distribution in the wheel-rail contact. The normal force distribution on the rail head was assumed to be Hertzian. The tangential force was implemented as a fraction of the normal force in the subroutine. Each analysis was carried out for a single pass and the effect of various friction coefficient values has been observed.
Resumo:
Insulated rail joints are critical for train safety as they control electrical signalling systems; unfortunately they exhibit excessive ratchetting of the railhead near the endpost insulators. This paper reports a three-dimensional global model of these joints under wheel–rail contact pressure loading and a sub-model examining the ratchetting failures of the railhead. The sub-model employs a non-linear isotropic–kinematic elastic–plastic material model and predicts stress/strain levels in the localised railhead zone adjacent to the endpost which is placed in the air gap between the two rail ends at the insulated rail joint. The equivalent plastic strain plot is utilised to capture the progressive railhead damage adequately. Associated field and laboratory testing results of damage to the railhead material suggest that the simulation results are reasonable.
Resumo:
The extreme diversity of conditions acting on railways necessitates a variety of experimental approaches to study the critical wear mechanisms that present themselves at the contact interface. This work investigates the effects of contact pressure and geometry in rolling-contact wear tests by using discs with different radii of curvature to simulate the varying contact conditions that may be typically found in the field. It is commonly adapted to line contact interface as it has constant contact pressure. But practical scenario of the rail wheel interface, the contact area increase and contact pressure change as tracks worn off. The tests were conducted without any significant amount of traction, but micro slip was still observed due to contact deformation. Moreover, variation of contact pressure was observed due to contact patch elongation and diameter reduction. Rolling contact fatigue, adhesive and sliding wear were observed on the curved contact interface. The development of different wear regimes and material removal phenomena were analysed using microscopic images in order to broaden the understanding of the wear mechanisms occurring in the rail-wheel contact.
Resumo:
This work investigates the effects of contact pressure and geometry in rolling-contact wear tests by using discs with different radii of curvature to simulate the varying contact conditions that may be typically found in the field. The tests were conducted without any significant amount of traction, but micro slip was still observed due to contact deformation. Moreover, variation of contact pressure was observed due to contact patch elongation and diameter reduction. Rolling contact fatigue, adhesive and sliding wear were observed on the curved contact interface. The development of different wear regimes and material removal phenomena were analyzed using microscopic images in order to broaden the understanding of the wear mechanisms occurring in the rail-wheel contact.
Resumo:
It is known that the vibrational spectra of beetle-type scanning tunneling microscopes with a total mass of ≈3–4 g contain extrinsic ‘rattling’ modes in the frequency range extending from 500 to 1700 Hz that interfere with image acquisition. These modes lie below the lowest calculated eigenfrequency of the beetle and it has been suggested that they arise from the inertial sliding of the beetle between surface asperities on the raceway. In this paper we describe some cross-coupling measurements that were performed on three home-built beetle-type STMs of two different designs. We provide evidence that suggests that for beetles with total masses of 12–15 g all the modes in the rattling range are intrinsic. This provides additional support for the notion that the vibrational properties of beetle-type scanning tunneling microscopes can be improved by increasing the contact pressure between the feet of the beetle and the raceway.
Resumo:
The gravity based structure (GBS) with external Steel–Concrete–Steel (SCS) sandwich ice-resistant wall has been developed for the Arctic oil and gas drilling. This paper firstly reported the experimental studies on the mechanical properties of steel and concretes under Arctic low temperature. With the test data, design equations were developed to incorporate the influences of the low temperature on these mechanical properties. Two types of Arctic GBS structure with flower-conical SCS sandwich shell type and plate type of ice-resistant wall have been developed for the Arctic offshore structure. Besides the studies on the materials, two SCS sandwich prototype shells and plates were, respectively, prepared and tested under patch loading that simulated the localized ice-contact pressure. The structural behaviors of the SCS sandwich structure under patch loading were reported and discussions were made on the influences of different parameters on the structural behavior of the structure. Analytical models were developed to predict the punching shear resistances of the SCS sandwich structure through modifying the code provisions. The accuracies of the developed analytical models were checked through validations against 27 tests in the literature. Corresponding design procedures on resistances of SCS sandwich structure were recommended based on these discussions and validations.
Resumo:
Purpose To investigate static upper eyelid pressure and contact with the ocular surface in a group of young adult subjects. Methods Static upper eyelid pressure was measured for 11 subjects using a piezoresistive pressure sensor attached to a rigid contact lens. Measures of eyelid pressure were derived from an active pressure cell (1.14 mm square) beneath the central upper eyelid margin. To investigate the contact region between the upper eyelid and ocular surface, we used pressure sensitive paper and the lissamine-green staining of Marx’s line. These measures combined with the pressure sensor readings were used to derive estimates of eyelid pressure. Results The mean contact width between the eyelids and ocular surface estimated using pressure sensitive paper was 0.60 ± 0.16 mm, while the mean width of Marx’s line was 0.09 ± 0.02 mm. The mean central upper eyelid pressure was calculated to be 3.8 ± 0.7 mmHg (assuming that the whole pressure cell was loaded), 8.0 ± 3.4 mmHg (derived using the pressure sensitive paper imprint widths) and 55 ± 26 mmHg (based on contact widths equivalent to Marx’s line). Conclusions The pressure sensitive paper measurements suggest that a band of the eyelid margin, significantly larger than the anatomical zone of the eyelid margin known as Marx’s line, has primary contact with the ocular surface. Using these measurements as the contact between the eyelid margin and ocular surface, we believe that the mean pressure of 8.0 ± 3.4 mmHg is the most reliable estimate of static upper eyelid pressure.
Resumo:
Background: To compare the intraocular pressure readings obtained with the iCare rebound tonometer and the 7CR non-contact tonometer with those measured by Goldmann applanation tonometry in treated glaucoma patients. Design: A prospective, cross sectional study was conducted in a private tertiary glaucoma clinic. Participants: 109 (54M:55F) patients including only eyes under medical treatment for glaucoma. Methods: Measurement by Goldmann applanation tonometry, iCare rebound tonometry and 7CR non-contact tonometry. Main Outcome Measures: Intraocular pressure. Results: There were strong correlations between the intraocular pressure measurements obtained with Goldmann and both the rebound and non-contact tonometers (Spearman r values ≥ 0.79, p < 0.001). However, there were small, statistically significant differences between the average readings for each tonometer. For the rebound tonometer, the mean intraocular pressure was slightly higher compared to the Goldmann applanation tonometer in the right eyes (p = 0.02), and similar in the left eyes (p = 0.93) however these differences did not reach statistical significance. The Goldmann correlated measurements from the noncontact tonometer were lower than the average Goldmann reading for both right (p < 0.001) and left (p > 0.01) eyes. The corneal compensated measurements from the non-contact tonometer were significantly higher compared to the other tonometers (p ≤ 0.001). Conclusions: The iCare rebound tonometer and the 7CR non-contact tonometer measure IOP in fundamentally different ways to the Goldmann applanation tonometer. The resulting IOP values vary between the instruments and will need to be considered when comparing clinical versus home acquired measurements.
Resumo:
Purpose: To assess the accuracy of intraocular pressure(IOP) measurements using rebound tonometry over disposable hydrogel (etafilcon A) and silicone hydrogel (senofilcon A) contact lenses (CLs) of different powers. Methods: The experimental group comprised 36 subjects (19 male, 17 female). IOP measurements were undertaken on the subject’s right eyes in random order using a rebound tonometer (ICare). The CLs had powers of +2.00D, −2.00D and−6.00D. Six measurements were taken over each contact lens and also before and after the CLs had been worn. Results: A good correlation was found between IOP measurements with and without CLs (all r≥0.80; p < 0.05). Bland Altman plots did not show any significant trend in the difference in IOP readings with and without CLs as a function of IOP value. A two-way ANOVA revealed a significant effect of material and power (p < 0.01) but no interaction. All the comparisons between the measurements without CLs and with hydrogel CLs were significant (p < 0.01). The comparisons with silicone hydrogel CLs were not significant. Conclusions: Rebound tonometry can be reliably performed over silicone hydrogel CLs. With hydrogel CLs, the measurements were lower than those without CLs. However, despite the fact that these differences were statistically significant, their clinical significance was minimal.
Resumo:
Purpose To investigate if the accuracy of intraocular pressure (IOP) measurements using rebound tonometry over disposable hydrogel (etafilcon A) contact lenses (CL) is affected by the positive power of the CLs. Methods The experimental group comprised 26 subjects, (8 male, 18 female). IOP measurements were undertaken on the subjects’ right eyes in random order using a Rebound Tonometer (ICare). The CLs had powers of +2.00D and +6.00D. Measurements were taken over each contact lens and also before and after the CLs had been worn. Results The IOP measure obtained with both CLs was significantly lower compared to the value without CLs (t test; p<0.001) but no significant difference was found between the two powers of CLs. Conclusions Rebound tonometry over positive hydrogel CLs leads to a certain degree of IOP underestimation. This result didn’t change for the two positive lenses used in the experiment, despite their large difference in power and therefore in lens thickness. Optometrists should bear this in mind when measuring IOP with the rebound tonometer over plus power contact lenses.
Resumo:
Aims: To investigate IOP measurements with the dynamic contour tonometer (DCT) and non contact tonometer (NCT) in subjects with keratoconus. Methods: Twenty keratoconic subjects and 20 age-matched control subjects had IOP measurements taken using DCT and NCT instruments. Central and offcentre measures were taken with the DCT in order to highlight any systematic errors associated with corneal biomechanical factors. Measures of anterior and posterior corneal topography and thickness were also taken for each subject. Results: No significant difference was found between the central and off-centre DCT IOP readings for the keratoconics and age-matched controls (p>0.05). The average DCT IOP for the keratoconics was 14.2 ± 1.4 mmHg and for the agematched controls was 14.2 ± 1.6 mmHg. However, the average NCT readings differed significantly (p<0.001) between the keratoconics (9.2 ± 1.5 mmHg) and age-matched controls (12.9 ± 2.4 mmHg). DCT IOP showed no significant (p>0.05) correlation with the severity of keratoconus, as determined through measures of corneal topography and thickness. NCT IOP was correlated significantly with certain measures of corneal curvature and thickness in the keratoconic population. The difference between DCT and NCT IOP was strongly correlated with measures of corneal topography and thickness, with differences increasing for more advanced keratoconus. Conclusions: The measurements from the DCT do not appear to be dependent upon corneal factors, unlike the NCT. The presence or severity of keratoconus was not correlated with DCT IOP values.
Resumo:
The eyelids play an important role in lubricating and protecting the surface of the eye. Each blink serves to spread fresh tears, remove debris and replenish the smooth optical surface of the eye. Yet little is known about how the eyelids contact the ocular surface and what pressure distribution exists between the eyelids and cornea. As the principal refractive component of the eye, the cornea is a major element of the eye’s optics. The optical properties of the cornea are known to be susceptible to the pressure exerted by the eyelids. Abnormal eyelids, due to disease, have altered pressure on the ocular surface due to changes in the shape, thickness or position of the eyelids. Normal eyelids also cause corneal distortions that are most often noticed when they are resting closer to the corneal centre (for example during reading). There were many reports of monocular diplopia after reading due to corneal distortion, but prior to videokeratoscopes these localised changes could not be measured. This thesis has measured the influence of eyelid pressure on the cornea after short-term near tasks and techniques were developed to quantify eyelid pressure and its distribution. The profile of the wave-like eyelid-induced corneal changes and the refractive effects of these distortions were investigated. Corneal topography changes due to both the upper and lower eyelids were measured for four tasks involving two angles of vertical downward gaze (20° and 40°) and two near work tasks (reading and steady fixation). After examining the depth and shape of the corneal changes, conclusions were reached regarding the magnitude and distribution of upper and lower eyelid pressure for these task conditions. The degree of downward gaze appears to alter the upper eyelid pressure on the cornea, with deeper changes occurring after greater angles of downward gaze. Although the lower eyelid was further from the corneal centre in large angles of downward gaze, its effect on the cornea was greater than that of the upper eyelid. Eyelid tilt, curvature, and position were found to be influential in the magnitude of eyelid-induced corneal changes. Refractively these corneal changes are clinically and optically significant with mean spherical and astigmatic changes of about 0.25 D after only 15 minutes of downward gaze (40° reading and steady fixation conditions). Due to the magnitude of these changes, eyelid pressure in downward gaze offers a possible explanation for some of the day-to-day variation observed in refraction. Considering the magnitude of these changes and previous work on their regression, it is recommended that sustained tasks performed in downward gaze should be avoided for at least 30 minutes before corneal and refractive assessment requiring high accuracy. Novel procedures were developed to use a thin (0.17 mm) tactile piezoresistive pressure sensor mounted on a rigid contact lens to measure eyelid pressure. A hydrostatic calibration system was constructed to convert raw digital output of the sensors to actual pressure units. Conditioning the sensor prior to use regulated the measurement response and sensor output was found to stabilise about 10 seconds after loading. The influences of various external factors on sensor output were studied. While the sensor output drifted slightly over several hours, it was not significant over the measurement time of 30 seconds used for eyelid pressure, as long as the length of the calibration and measurement recordings were matched. The error associated with calibrating at room temperature but measuring at ocular surface temperature led to a very small overestimation of pressure. To optimally position the sensor-contact lens combination under the eyelid margin, an in vivo measurement apparatus was constructed. Using this system, eyelid pressure increases were observed when the upper eyelid was placed on the sensor and a significant increase was apparent when the eyelid pressure was increased by pulling the upper eyelid tighter against the eye. For a group of young adult subjects, upper eyelid pressure was measured using this piezoresistive sensor system. Three models of contact between the eyelid and ocular surface were used to calibrate the pressure readings. The first model assumed contact between the eyelid and pressure sensor over more than the pressure cell width of 1.14 mm. Using thin pressure sensitive carbon paper placed under the eyelid, a contact imprint was measured and this width used for the second model of contact. Lastly as Marx’s line has been implicated as the region of contact with the ocular surface, its width was measured and used as the region of contact for the third model. The mean eyelid pressures calculated using these three models for the group of young subjects were 3.8 ± 0.7 mmHg (whole cell), 8.0 ± 3.4 mmHg (imprint width) and 55 ± 26 mmHg (Marx’s line). The carbon imprints using Pressurex-micro confirmed previous suggestions that a band of the eyelid margin has primary contact with the ocular surface and provided the best estimate of the contact region and hence eyelid pressure. Although it is difficult to directly compare the results with previous eyelid pressure measurement attempts, the eyelid pressure calculated using this model was slightly higher than previous manometer measurements but showed good agreement with the eyelid force estimated using an eyelid tensiometer. The work described in this thesis has shown that the eyelids have a significant influence on corneal shape, even after short-term tasks (15 minutes). Instrumentation was developed using piezoresistive sensors to measure eyelid pressure. Measurements for the upper eyelid combined with estimates of the contact region between the cornea and the eyelid enabled quantification of the upper eyelid pressure for a group of young adult subjects. These techniques will allow further investigation of the interaction between the eyelids and the surface of the eye.