34 resultados para CIM-OSA
em Queensland University of Technology - ePrints Archive
Resumo:
Despite being poised as a standard for data exchange for operation and maintenance data, the database heritage of the MIMOSA OSA-EAI is clearly evident from using a relational model at its core. The XML schema (XSD) definitions, which are used for communication between asset management systems, are based on the MIMOSA common relational information schema (CRIS), a relational model, and consequently, many database concepts permeate the communications layer. The adoption of a relational model leads to several deficiencies, and overlooks advances in object-oriented approach for an upcoming version of the specification, and the common conceptual object model (CCOM) sees a transition to fully utilising object-oriented features for the standard. Unified modelling language (UML) is used as a medium for documentation as well as facilitating XSD code generation. This paper details some of the decisions faced in developing the CCOM and provides a glimpse into the future of asset management and data exchange models.
Resumo:
Objectives To examine the effects on monotonous driving of normal sleep versus one night of sleep restriction in continuous positive airway pressure (CPAP) treated obstructive sleep apnoea (OSA) patients compared with age matched healthy controls. Methods Nineteen CPAP treated compliant male OSA patients (OSA-treated patients (OPs)), aged 50–75 years, and 20 healthy age-matched controls underwent both a normal night’s sleep and sleep restriction to 5 h (OPs remained on CPAP) in a counterbalanced design. All participants completed a 2 h afternoon monotonous drive in a realistic car simulator. Driving was monitored for sleepiness-related minor and major lane deviations, with ‘safe’ driving time being total time driven prior to first major lane deviation. EEGs were recorded continuously, and subjective sleepiness ratings were taken at regular intervals throughout the drive. Results After a normal night’s sleep, OPs and controls did not differ in terms of driving performance or in their ability to assess the levels of their own sleepiness, with both groups driving ‘safely’ for approximately 90 min. However, after sleep restriction, OPs had a significantly shorter (65 min) safe driving time and had to apply more compensatory effort to maintain their alertness compared with controls. They also underestimated the enhanced sleepiness. Nevertheless, apart from this caveat, there were generally close associations between subjective sleepiness, likelihood of a major lane deviation and EEG changes indicative of sleepiness. Conclusions With a normal night’s sleep, effectively treated older men with OSA drive as safely as healthy men of the same age. However, after restricted sleep, driving impairment is worse than that of controls. This suggests that, although successful CPAP treatment can alleviate potential detrimental effects of OSA on monotonous driving following normal sleep, these patients remain more vulnerable to sleep restriction.
Resumo:
Purpose Obstructive sleep apnoea (OSA) patients effectively treated by and compliant with continuous positive air pressure (CPAP) occasionally miss a night’s treatment. The purpose of this study was to use a real car interactive driving simulator to assess the effects of such an occurrence on the next day’s driving, including the extent to which these drivers are aware of increased sleepiness. Methods Eleven long-term compliant CPAP-treated 50–75-year-old male OSA participants completed a 2-h afternoon, simulated, realistic monotonous drive in an instrumented car, twice, following one night: (1) normal sleep with CPAP and (2) nil CPAP. Drifting out of road lane (‘incidents’), subjective sleepiness every 200 s and continuous electroencephalogram (EEG) activities indicative of sleepiness and compensatory effort were monitored. Results Withdrawal of CPAP markedly increased sleep disturbance and led to significantly more incidents, a shorter ‘safe’ driving duration, increased alpha and theta EEG power and greater subjective sleepiness. However, increased EEG beta activity indicated that more compensatory effort was being applied. Importantly, under both conditions, there was a highly significant correlation between subjective and EEG measures of sleepiness, to the extent that participants were well aware of the effects of nil CPAP. Conclusions Patients should be aware that compliance with treatment every night is crucial for safe driving.
Resumo:
Introduction Sleep restriction and missing 1 night’s continuous positive air pressure (CPAP) treatment are scenarios faced by obstructive sleep apnoea (OSA) patients, who must then assess their own fitness to drive. This study aims to assess the impact of this on driving performance. Method 11 CPAP treated participants (50–75 yrs), drove an interactive car simulator under monotonous motorway conditions for 2 hours on 3 afternoons, following;(i)normal night’s sleep (average 8.2 h) with CPAP (ii) sleep restriction (5 h), with CPAP (iii)normal length of sleep, without CPAP. Driving incidents were noted if the car came out of the designated driving lane. EEG was recorded continually and KSS reported every 200 seconds. Results Driving incidents: Incidents were more prevalent following CPAP withdrawal during hour 1, demonstrating a significant condition time interaction [F(6,60) = 3.40, p = 0.006]. KSS: At the start of driving participants felt sleepiest following CPAP withdrawal, by the end of the task KSS levels were similar following CPAP withdrawal and sleep restriction, demonstrating a significant condition, time interaction [F(3.94,39.41) = 3.39, p = 0.018]. EEG: There was a non significant trend for combined alpha and theta activity to be highest throughout the drive following CPAP withdrawal. Discussion CPAP withdrawal impairs driving simulator performance sooner than restricting sleep to 5 h with CPAP. Participants had insight into this increased sleepiness reflected by the higher KSS reported following CPAP withdrawal. In the practical terms of driving any one incident could be fatal. The earlier impairment reported here demonstrates the potential danger of missing CPAP treatment and highlights the benefit of CPAP treatment even when sleep time is short.
Resumo:
This paper discusses Compulsory Income Management (CIM) in Australia and the implications of technology backed forms of surveillance and increasingly conditional benefit payments. The CIM project raises important questions about requiring people to take greater responsibility for their personal behaviour when they no longer have control over key financial aspects of their lives. Some Indigenous communities have resisted the BasicsCard, because CIM was imposed with little prior consultation or subsequent independent evaluation. The compulsory income management of individuals by a paternalist welfare state contradicts and undermines the purported policy aims that they become less welfare dependent and more positively engaged with the world of paid employment and does little to address the growing condition of poverty in Australia.
E-marketing : the impact of self-service technology on consumer satisfaction and consumer commitment
Resumo:
Traditionally, service encounters have included an interpersonal interaction between the service provider and the customer. The introduction ofself-service technologies to the service encounter, however, is reducing and in some cases, eliminating this interpersonal interaction. Self-se rvice technology is where the customer delivers the service themselves using a technological interface. This CIM funded research programme investigates the effect of self-service technology on the service encounter, and in turn on consumer satisfaction and consumer commitment. This paper reviews the literature relevant to the current study and outlines the constructs of interest in this study. The resear ch hypotheses and conceptual model are also introduced.Finally, the agenda for future research is presented.
Resumo:
Background: The reasons that a patient has to start treatment, their “Cues to Action”, are important for determining subsequent health behaviours. Cues to action are an explicit component of the Health Belief Model of CPAP acceptance adherence. At present there is no scale available to measure this construct for individuals with Obstructive Sleep Apnoea (OSA). This paper aims to develop, validate and describe responding patterns within an OSA patient sample to the Cues to CPAP Use Questionnaire (CCUQ).----- Method: Participants were 63 adult patients diagnosed with OSA who had never tried CPAP when initially recruited. The CCUQ was completed at one month after being prescribed CPAP.----- Results: Exploratory factor analysis (EFA) showed a three factor structure of the 9-item CCUQ, with “Health Cues”, “Partner Cues” and “Health Professional Cues” subscales accounting for 59.91% of the total variance. The CCUQ demonstrated modest internal consistency and split-half reliability. The questionnaire is brief and user-friendly, with readability at a 7th grade level. The most frequently endorsed cues for starting CPAP were Health Professional Cues (prompting by the sleep physician) and Health Cues such as tiredness and concern about health outcomes.----- Conclusions: This study validates a measure of an important motivational component of the Health Belief Model. Health Professional Cues and internal Health Cues were reported to be the most important prompts to commence CPAP by this patient sample.
Resumo:
An asset registry arguably forms the core system that needs to be in place before other systems can operate or interoperate. Most systems have rudimentary asset registry functionality that store assets, relationships, or characteristics, and this leads to different asset management systems storing similar sets of data in multiple locations in an organisation. As organisations have been slowly moving their information architecture toward a service-oriented architecture, they have also been consolidating their multiple data stores, to form a “single point of truth”. As part of a strategy to integrate several asset management systems in an Australian railway organisation, a case study for developing a consolidated asset registry was conducted. A decision was made to use the MIMOSA OSA-EAI CRIS data model as well as the OSA-EAI Reference Data in building the platform due to the standard’s relative maturity and completeness. A pilot study of electrical traction equipment was selected, and the data sources feeding into the asset registry were primarily diagrammatic based. This paper presents the pitfalls encountered, approaches taken, and lessons learned during the development of the asset registry.
Resumo:
A crucial process of chlamydial development involves differentiation of the replicative reticulate body (RB) into the infectious elementary body (EB). We present experimental evidence to provide support for a contact-dependent hypothesis for explaining the trigger involved in differentiation. We recorded live-imaging of Chlamydia trachomatis-infected McCoy cells at key times during development and tracked the temporospatial trajectories of individual chlamydial particles. We found that movement of the particles is related to development. Early to mid-developmental stages involved slight wobbling of RBs. The average speed of particles increased sharply at 24 h postinfection (after the estimated onset of RB to EB differentiation). We also investigated a penicillin-supplemented culture containing EBs, RBs, and aberrantly enlarged, stressed chlamydiae. Near-immobile enlarged particles are consistent with their continued tethering to the chlamydial inclusion membrane (CIM). We found a significantly negative, nonlinear association between speed and size/type of particles, providing further support for the hypothesis that particles become untethered near the onset of RB to EB differentiation. This study establishes the relationship between the motion properties of the chlamydiae and developmental stages, whereby wobbling RBs gradually lose contact with the CIM, and RB detachment from the CIM is coincidental with the onset of late differentiation.
Resumo:
Over the last decade, system integration has grown in popularity as it allows organisations to streamline business processes. Traditionally, system integration has been conducted through point-to-point solutions – as a new integration scenario requirement arises, a custom solution is built between the relevant systems. Bus-based solutions are now preferred, whereby all systems communicate via an intermediary system such as an enterprise service bus, using a common data exchange model. This research investigates the use of a common data exchange model based on open standards, specifically MIMOSA OSA-EAI, for asset management system integration. A case study is conducted that involves the integration of processes between a SCADA, maintenance decision support and work management system. A diverse number of software platforms are employed in developing the final solution, all tied together through MIMOSA OSA-EAI-based XML web services. The lessons learned from the exercise are presented throughout the paper.
Resumo:
On-axis monochromatic higher-order aberrations increase with age. Few studies have been made of peripheral refraction along the horizontal meridian of older eyes, and none of their off-axis higher-order aberrations. We measured wave aberrations over the central 42°x32° visual field for a 5mm pupil in 10 young and 7 older emmetropes. Patterns of peripheral refraction were similar in the two groups. Coma increased linearly with field angle at a significantly higher rate in older than in young emmetropes (−0.018±0.007 versus −0.006±0.002 µm/deg). Spherical aberration was almost constant over the measured field in both age groups and mean values across the field were significantly higher in older than in young emmetropes (+0.08±0.05 versus +0.02±0.04 µm). Total root-mean-square and higher-order aberrations increased more rapidly with field angle in the older emmetropes. However, the limits to monochromatic peripheral retinal image quality are largely determined by the second-order aberrations, which do not change markedly with age, and under normal conditions the relative importance of the increased higher-order aberrations in older eyes is lessened by the reduction in pupil diameter with age. Therefore it is unlikely that peripheral visual performance deficits observed in normal older individuals are primarily attributable to the increased impact of higher-order aberration.
Resumo:
Purpose: Poor image quality in the peripheral field may lead to myopia. Most studies measuring the higher order aberrations in the periphery have been restricted to the horizontal visual field. The purpose of this study was to measure higher order monochromatic aberrations across the central 42º horizontal x 32º vertical visual fields in myopes and emmetropes. ---------- Methods: We recruited 5 young emmetropes with spherical equivalent refractions +0.17 ± 0.45D and 5 young myopes with spherical equivalent refractions -3.9 ± 2.09D. Measurements were taken with a modified COAS-HD Hartmann-Shack aberrometer (Wavefront Sciences Inc). Measurements were taken while the subjects looked at 38 points arranged in a 7 x 6 matrix (excluding four corner points) through a beam splitter held between the instrument and the eye. A combination of the instrument’s software and our own software was used to estimate OSA Zernike coefficients for 5mm pupil diameter at 555nm for each point. The software took into account the elliptical shape of the off-axis pupil. Nasal and superior fields were taken to have positive x and y signs, respectively. ---------- Results: The total higher order RMS (HORMS) was similar on-axis for emmetropes (0.16 ± 0.02 μm) and myopes (0.17 ± 0.02 μm). There was no common pattern for HORMS for emmetropes across the visual field where as 4 out of 5 myopes showed a linear increase in HORMS in all directions away from the minimum. For all subjects, vertical and horizontal comas showed linear changes across the visual field. The mean rate of change of vertical coma across the vertical meridian was significantly lower (p = 0.008) for emmetropes (-0.005 ± 0.002 μm/deg) than for myopes (-0.013 ± 0.004 μm/deg). The mean rate of change of horizontal coma across the horizontal meridian was lower (p = 0.07) for emmetropes (-0.006 ± 0.003 μm/deg) than myopes (-0.011 ± 0.004 μm/deg). ---------- Conclusion: We have found differences in patterns of higher order aberrations across the visual fields of emmetropes and myopes, with myopes showing the greater rates of change of horizontal and vertical coma.
Resumo:
We present a novel method and instrument for in vivo imaging and measurement of the human corneal dynamics during an air puff. The instrument is based on high-speed swept source optical coherence tomography (ssOCT) combined with a custom adapted air puff chamber from a non-contact tonometer, which uses an air stream to deform the cornea in a non-invasive manner. During the short period of time that the deformation takes place, the ssOCT acquires multiple A-scans in time (M-scan) at the center of the air puff, allowing observation of the dynamics of the anterior and posterior corneal surfaces as well as the anterior lens surface. The dynamics of the measurement are driven by the biomechanical properties of the human eye as well as its intraocular pressure. Thus, the analysis of the M-scan may provide useful information about the biomechanical behavior of the anterior segment during the applanation caused by the air puff. An initial set of controlled clinical experiments are shown to comprehend the performance of the instrument and its potential applicability to further understand the eye biomechanics and intraocular pressure measurements. Limitations and possibilities of the new apparatus are discussed.
Resumo:
We modified a commercial Hartmann-Shack aberrometer and used it to measure ocular aberrations across the central 42º horizontal x 32º vertical visual fields of five young emmetropic subjects. Some Zernike aberration coefficients show coefficient field distributions that were similar to the field dependence predicted by Seidel theory (astigmatism, oblique astigmatism, horizontal coma, vertical coma), but defocus did not demonstrate such similarity.