16 resultados para Bufo marinus - Cardiovascular system

em Queensland University of Technology - ePrints Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cardiovascular assist devices are tested in mock circulation loops (MCLs) prior to animal and clinical testing. These MCLs rely on characteristics such as pneumatic parameters to create pressure and flow, and pipe dimensions to replicate the resistance, compliance and fluid inertia of the natural cardiovascular system. A mathematical simulation was developed in SIMULINK to simulate an existing MCL. Model validation was achieved by applying the physical MCL characteristics to the simulation and comparing the resulting pressure traces. These characteristics were subsequently altered to improve and thus predict the performance of a more accurate physical system. The simulation was successful in simulating the physical mock circulation loop, and proved to be a useful tool in the development of improved cardiovascular device test rigs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In vitro cardiovascular device performance evaluation in a mock circulation loop (MCL) is a necessary step prior to in vivo testing.A MCL that accurately represents the physiology of the cardiovascular system accelerates the assessment of the device’s ability to treat pathological conditions. To serve this purpose, a compact MCL measuring 600 ¥ 600 ¥ 600 mm (L ¥ W¥ H) was constructed in conjunction with a computer mathematical simulation.This approach allowed the effective selection of physical loop characteristics, such as pneumatic drive parameters, to create pressure and flow, and pipe dimensions to replicate the resistance, compliance, and fluid inertia of the native cardiovascular system. The resulting five-element MCL reproduced the physiological hemodynamics of a healthy and failing heart by altering ventricle contractility, vascular resistance/compliance, heart rate, and vascular volume. The effects of interpatient anatomical variability, such as septal defects and valvular disease, were also assessed. Cardiovascular hemodynamic pressures (arterial, venous, atrial, ventricular), flows (systemic, bronchial, pulmonary), and volumes (ventricular, stroke) were analyzed in real time. The objective of this study is to describe the developmental stages of the compact MCL and demonstrate its value as a research tool for the accelerated development of cardiovascular devices.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Airborne particulate matter pollution is of concern for a number of reasons and has been widely recognised as an important risk factor to human health. A number of toxicological and epidemiological studies reported negative health effects on both respiratory and cardiovascular system. Despite the availability of a huge body of research, the underlying toxicological mechanisms by which particles induce adverse health effects are not yet entirely understood. The production of reactive oxygen species (ROS) has been shown to induce oxidative stress, which is proposed as a mechanism for many of the adverse health outcomes associated with exposure to particulate matter (PM). Therefore, it is crucial to introduce a technique that will allow rapid and routine screenings of the oxidative potential of PM.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To identify potential migraine therapeutics, extracts of eighteen plants were screened to detect plant constituents affecting ADP induced platelet aggregation and [14C]5-hydroxytryptamine (5-HT) release. Extracts of the seven plants exhibiting significant inhibition of platelet function were reanalysed in the presence of polyvinyl pyrrolidone (PVP) to remove polyphenolic tannins that precipitate proteins. Two of these extracts no longer exhibited inhibition of platelet activity after removal of tannins. However, extracts of Crataegus monogyna, Ipomoea pes-caprae, Eremophila freelingii, Eremophila longifolia, and Asteromyrtus symphyocarpa still potently inhibited ADP induced human platelet [14C]5-HT release in vitro, with levels ranging from 62 to 95% inhibition. I. pes-caprae, and C. monogyna also caused significant inhibition of ADP induced platelet aggregation. All of these plants have been previously used as traditional headache treatments, except for C. monogyna which is used primarily for protective effects on the cardiovascular system. Further studies elucidating the compounds that are responsible for these anti-platelet effects are needed to determine their exact mechanism of action.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of exercise training is to initiate desirable physiological adaptations that ultimately enhance physical work capacity. Optimal training prescription requires an individualized approach, with an appropriate balance of training stimulus and recovery and optimal periodization. Recovery from exercise involves integrated physiological responses. The cardiovascular system plays a fundamental role in facilitating many of these responses, including thermoregulation and delivery/removal of nutrients and waste products. As a marker of cardiovascular recovery, cardiac parasympathetic reactivation following a training session is highly individualized. It appears to parallel the acute/intermediate recovery of the thermoregulatory and vascular systems, as described by the supercompensation theory. The physiological mechanisms underlying cardiac parasympathetic reactivation are not completely understood. However, changes in cardiac autonomic activity may provide a proxy measure of the changes in autonomic input into organs and (by default) the blood flow requirements to restore homeostasis. Metaboreflex stimulation (e.g. muscle and blood acidosis) is likely a key determinant of parasympathetic reactivation in the short term (0–90 min post-exercise), whereas baroreflex stimulation (e.g. exercise-induced changes in plasma volume) probably mediates parasympathetic reactivation in the intermediate term (1–48 h post-exercise). Cardiac parasympathetic reactivation does not appear to coincide with the recovery of all physiological systems (e.g. energy stores or the neuromuscular system). However, this may reflect the limited data currently available on parasympathetic reactivation following strength/resistance-based exercise of variable intensity. In this review, we quantitatively analyse post-exercise cardiac parasympathetic reactivation in athletes and healthy individuals following aerobic exercise, with respect to exercise intensity and duration, and fitness/training status. Our results demonstrate that the time required for complete cardiac autonomic recovery after a single aerobic-based training session is up to 24 h following low-intensity exercise, 24–48 h following threshold-intensity exercise and at least 48 h following high-intensity exercise. Based on limited data, exercise duration is unlikely to be the greatest determinant of cardiac parasympathetic reactivation. Cardiac autonomic recovery occurs more rapidly in individuals with greater aerobic fitness. Our data lend support to the concept that in conjunction with daily training logs, data on cardiac parasympathetic activity are useful for individualizing training programmes. In the final sections of this review, we provide recommendations for structuring training microcycles with reference to cardiac parasympathetic recovery kinetics. Ultimately, coaches should structure training programmes tailored to the unique recovery kinetics of each individual.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Rotary ventricular assist device (VAD) support of the cardiovascular system is susceptible to suction events due to the limited preload sensitivity of these devices. This may be of particular concern with rotary biventricular support (BiVAD) where the native, flow-balancing Starling response is diminished in both ventricles. The reliability of sensor and sensor-less based control systems which aim to control VAD flow based on preload have limitations and thus an alternative solution is desired. This study introduces a compliant inflow cannula (CIC) which could improve the preload sensitivity of a rotary VAD by passively altering VAD flow depending on preload. To evaluate the design, both the CIC and a standard rigid inflow cannula were inserted into a mock circulation loop to enable biventricular heart failure support using configurations of atrial and ventricular inflow, and arterial outflow cannulation. A range of left (LVAD) and right VAD (RVAD) rotational speeds were tested as well as step changes in systemic/pulmonary vascular resistance to alter relative preloads, with resulting flow rates recorded. Simulated suction events were observed, particularly at higher VAD speeds, during support with the rigid inflow cannula, while the CIC prevented suction events under all circumstances. The compliant section passively restricted its internal diameter as preload was reduced, which increased the VAD circuit resistance and thus reduced VAD flow. Therefore, a compliant inflow cannula could potentially be used as a passive control system to prevent suction events in rotary left, right and biventricular support.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Chlamydia pneumoniae is an obligate intracellular bacterium implicated in a wide range of human diseases including atherosclerosis and Alzheimer's disease. Efforts to understand the relationships between C. pneumoniae detected in these diseases have been hindered by the availability of sequence data for non-respiratory strains. In this study, we sequenced the whole genomes for C. pneumoniae isolates from atherosclerosis and Alzheimer's disease, and compared these to previously published C. pneumoniae genomes. Phylogenetic analyses of these new C. pneumoniae strains indicate two sub-groups within human C. pneumoniae, and suggest that both recombination and mutation events have driven the evolution of human C. pneumoniae. Further fine-detailed analyses of these new C. pneumoniae sequences show several genetically variable loci. This suggests that similar strains of C. pneumoniae are found in the brain, lungs and cardiovascular system and that only minor genetic differences may contribute to the adaptation of particular strains in human disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Identification of vulnerable plaque pre-rupture is extremely important for patient risk stratification. The mechanism of plaque rupture is still not entirely clear, but it is thought to be a process involving multiple factors. From a biomechanical viewpoint, plaque rupture is usually seen as a structural failure when the plaque cannot resist the hemodynamic blood pressure and shear stress exerted on it. However, the cardiovascular system is naturally a cyclical hemodynamic environment, and myocardial infarction can be a symptomatically quiescent but potentially progressive process when plaque ruptures at stresses much lower than its strength. Therefore, fatigue accumulation is a possible mechanism for plaque rupture. In this study, a crack growth model was developed, and the previously-mentioned hypothesis was tested by conducting a comparative study between 18 symptomatic and 16 asymptomatic patients with carotid stenosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Rupture of atheromatous plaque is the major cause of stroke or heart attack. Considering that the cardiovascular system is a classic fatigue environment, plaque rupture was treated as a chronic fatigue crack growth process in this study. Fracture mechanics theory was introduced to describe the stress status at the crack tip and Paris' law was used to calculate the crack growth rate. The effect of anatomical variation of an idealized plaque cross-section model was investigated. The crack initiation was considered to be either at the maximum circumferential stress location or at any other possible locations around the lumen. Although the crack automatically initialized at the maximum circumferential stress location usually propagated faster than others, it was not necessarily the most critical location where the fatigue life reached its minimum. We found that the fatigue life was minimum for cracks initialized in the following three regions: the midcap zone, the shoulder zone, and the backside zone. The anatomical variation has a significant influence on the fatigue life. Either a decrease in cap thickness or an increase in lipid pool size resulted in a significant decrease in fatigue life. Comparing to the previously used stress analysis, this fatigue model provides some possible explanations of plaque rupture at a low stress level in a pulsatile cardiovascular environment, and the method proposed here may be useful for further investigation of the mechanism of plaque rupture based on in vivo patient data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Rupture of atheromatous plaque in the carotid artery often leads to thrombosis and subsequent stroke. The mechanism of plaque rupture is not entirely clear but is thought to be a multi-factorial process involving thinning and weakening of the fibrous cap and biomechanical stress as the trigger leading to plaque rupture. As the cardiovascular system is a classic fatigue environment, the weakening of plaque leading to rupture may be a fatigue process, which is a symptomatically quiescent but potentially progressive failure process. In this study, we used a fatigue analysis based on in vivo magnetic resonance imaging (MRI) to investigate the rupture initiation location, crack propagation path and fatigue life within plaques of asymptomatic and symptomatic individuals. METHODS: Forty non-consecutive subjects (20 symptomatic and 20 asymptomatic) underwent high-resolution multi-sequence in vivo MRI of the carotid bifurcation. Fatigue analysis was performed based on the plaque geometry derived from in vivo MRI of the carotid artery at the point of maximum stenosis. Paris’ Law in fracture mechanics is adopted to determine the fatigue crack growth rate. Incremental crack propagation was dynamically simulated based on stress distributions. Plaque initiation location, crack propagation path and fatigue cycle of symptomatic and asymptomatic individuals were compared. RESULTS: Cracks were often found to begin at the lumen wall at areas of stress concentration. The preferred rupture direction was radial from the lumen center. The crack initially advanced slowly but accelerated as it developed, depending on plaque morphology. The fatigue cycles of symptomatic plaques were significantly less than those in the asymptomatic group (2.3 ± 0.9 vs 3.1 ± 0.7 (x106); p = 0.003). CONCLUSIONS: The number of cycles to rupture in symptomatic patients was higher than those predicted in asymptomatic patients by fatigue analysis, suggesting the possibility that plaques with a less fatigue life may be more prone to be symptomatic and rupture. If further validated by large-scale longitudinal studies, fatigue analysis based on high resolution in vivo MRI could potentially act as a useful tool for risk assessment of carotid atheroma.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study evaluates the effectiveness and social implications of home monitoring of 31 infants at risk of sudden infant death syndrome (SIDS). Thirteen siblings of children dying of SIDS, nine near miss SIDS infants and nine preterm infants with apnoea persisting beyond 40 weeks post conceptual age were monitored from a mean age of 15 days to a mean of 10 months. Chest movement detection monitors were used in 27 and thoracic impedance monitors in four. Genuine apnoeic episodes were reported by 21 families, and 13 infants required resuscitation. Apnoeic episodes occurred in all nine preterm infants but in only five (38%) of the siblings of SIDS (P<0.05). Troublesome false alarms were a major problem occurring with 61% of the infants and were more common with the preterm infants than the siblings of SIDS. All but two couples stated that the monitor decreased anxiety and improved their quality of life. Most parents accepted that the social restrictions imposed by the monitor were part of the caring process but four couples were highly resentful of the changes imposed on their lifestyle. The monitors used were far from ideal with malfunction occurring in 17, necessitating replacement in six, repair in six and cessation of monitoring in three. The parents became ingenious in modifying the monitors to their own individual requirements Although none of these 31 ‘at risk’ infants died the study sample was far too small to conclude whether home monitoring prevented any cases of SIDS.