Purpose: To estimate refractive indices used with the Lenstar biometer. Methods: Axial lengths of model eyes were determined using an IOLMaster biometer and a Lenstar; comparing these lengths gave an overall eye index for the Lenstar. Using the Lenstar Graphical User interface, we determined that boundaries between media could be manipulated so that there were opposite changes in optical pathlength on either side of the boundary and specified changes in distances determined the ratios of media indices. These ratios were combined with the overall eye index to estimate indices. Results: The IOLMaster and Lenstar produced axial length estimates to within ±0.01 mm. Estimations of group refractive indices were 1.340, 1.341, 1.415 and 1.354 for cornea, aqueous, lens and overall eye, respectively. The aqueous and lens indices, but not those for the cornea, are similar to schematic eye indices and reasonable lens indices. Conclusion: The Lenstar appears to use different refractive indices for different ocular media.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE To estimate refractive indices used by the Lenstar biometer to translate measured optical path lengths into geometrical path lengths within the eye. METHODS Axial lengths of model eyes were determined using the IOLMaster and Lenstar biometers; comparing those lengths gave an overall eye refractive index estimate for the Lenstar. Using the Lenstar Graphical User Interface, we noticed that boundaries between media could be manipulated and opposite changes in optical path lengths on either side of the boundary could be introduced. Those ratios were combined with the overall eye refractive index to estimate separate refractive indices. Furthermore, Haag-Streit provided us with a template to obtain 'air thicknesses' to compare with geometrical distances. RESULTS The axial length estimates obtained using the IOLMaster and the Lenstar agreed to within 0.01 mm. Estimates of group refractive indices used in the Lenstar were 1.340, 1.341, 1.415, and 1.354 for cornea, aqueous, lens, and overall eye, respectively. Those refractive indices did not match those of schematic eyes, but were close in the cases of aqueous and lens. Linear equations relating air thicknesses to geometrical thicknesses were consistent with our findings. CONCLUSION The Lenstar uses different refractive indices for different ocular media. Some of the refractive indices, such as that for the cornea, are not physiological; therefore, it is likely that the calibrations in the instrument correspond to instrument-specific corrections and are not the real optical path lengths.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Information uncertainty which is inherent in many real world applications brings more complexity to the visualisation problem. Despite the increasing number of research papers found in the literature, much more work is needed. The aims of this chapter are threefold: (1) to provide a comprehensive analysis of the requirements of visualisation of information uncertainty and their dimensions of complexity; (2) to review and assess current progress; and (3) to discuss remaining research challenges. We focus on four areas: information uncertainty modelling, visualisation techniques, management of information uncertainty modelling, propagation and visualisation, and the uptake of uncertainty visualisation in application domains.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To determine likely errors in estimating retinal shape using partial coherence interferometric instruments when no allowance is made for optical distortion. Method: Errors were estimated using Gullstrand’s No. 1 schematic eye and variants which included a 10 D axial myopic eye, an emmetropic eye with a gradient-index lens, and a 10.9 D accommodating eye with a gradient-index lens. Performance was simulated for two commercial instruments, the IOLMaster (Carl Zeiss Meditec) and the Lenstar LS 900 (Haag-Streit AG). The incident beam was directed towards either the centre of curvature of the anterior cornea (corneal-direction method) or the centre of the entrance pupil (pupil-direction method). Simple trigonometry was used with the corneal intercept and the incident beam angle to estimate retinal contour. Conics were fitted to the estimated contours. Results: The pupil-direction method gave estimates of retinal contour that were much too flat. The cornea-direction method gave similar results for IOLMaster and Lenstar approaches. The steepness of the retinal contour was slightly overestimated, the exact effects varying with the refractive error, gradient index and accommodation. Conclusion: These theoretical results suggest that, for field angles ≤30º, partial coherence interferometric instruments are of use in estimating retinal shape by the corneal-direction method with the assumptions of a regular retinal shape and no optical distortion. It may be possible to improve on these estimates out to larger field angles by using optical modeling to correct for distortion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To assess intrasessional and intersessional repeatability of two commercial partial coherence interferometry instruments for measuring peripheral eye lengths and to investigate the agreement between the two instruments. Methods: Central and peripheral eye lengths were determined with the IOLMaster (Carl-Zeiss Meditec AG, Jena, Germany) and the Lenstar (Haag Streit, Bern, Switzerland) in seven adults. Measurements were performed out to 35° and 30° from fixation for horizontal and vertical visual fields, respectively, in 5° intervals. An external fixation target at optical infinity was used. At least four measurements were taken at each location for each instrument, and measurements were taken at two sessions. Results: The mean intrasessional SDs for the IOLMaster along both the horizontal and vertical visual fields were 0.04 ± 0.04 mm; corresponding results for the Lenstar were 0.02 ± 0.02 mm along both fields. The intersessional SDs for the IOLMaster for the horizontal and vertical visual fields were ±0.11 and ±0.08 mm, respectively; corresponding limits for the Lenstar were ±0.05 and ±0.04 mm. The intrasessional and intersessional variability increased away from fixation. The mean differences between the two instruments were 0.01 ± 0.07 mm and 0.02 ± 0.07 mm in the horizontal and vertical visual fields, but the lengths with the Lenstar became greater than those with the IOLMaster as axial length increased (rate of approximately 0.016 mm/mm). Conclusions: Both the IOLMaster and the Lenstar demonstrated good intrasessional and intersessional repeatability for peripheral eye length measurements, with the Lenstar showing better repeatability. The Lenstar would be expected to give a slightly greater range of eye lengths than the IOLMaster across the visual field.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose:Race appears to be associated with myopiogenesis, with East Asians showing high myopia prevalence. Considering structural variations in the eye, it is possible that retinal shapes are different between races. The purpose of this study was to quantify and compare retinal shapes between racial groups using peripheral refraction (PR) and peripheral eye lengths (PEL). Methods:A Shin-Nippon SRW5000 autorefractor and a Haag-Streit Lenstar LS900 biometer measured PR and PEL, respectively, along horizontal (H) and vertical (V) fields out to ±35° in 5° steps in 29 Caucasian (CA), 16 South Asian (SA) and 23 East Asian (EA) young adults (spherical equivalent range +0.75D to –5.00D in all groups). Retinal vertex curvature Rv and asphericity Q were determined from two methods: a) PR (Dunne): The Gullstrand-Emsley eye was modified according to participant’s intraocular lengths and anterior cornea curvature. Ray-tracing was performed at each angle through the stop, altering cornea asphericity until peripheral astigmatism matched experimental measurements. Retinal curvature and hence retinal co-ordinate intersection with the chief ray were altered until sagittal refraction matched its measurement. b) PEL: Ray-tracing was performed at each angle through the anterior corneal centre of curvature of the Gullstrand-Emsley eye. Ignoring lens refraction, retinal co-ordinates relative to the fovea were determined from PEL and trigonometry. From sets of retinal co-ordinates, conic retinal shapes were fitted in terms of Rv and Q. Repeated-measures ANOVA were conducted on Rv and Q, and post hoc t-tests with Bonferroni correction were used to compare races. Results:In all racial groups both methods showed greater Rv for the horizontal than for the vertical meridian and greater Rv for myopes than emmetropes. Rv was greater in EA than in CA (P=0.02), with Rv for SA being intermediate and not significantly different from CA and EA. The PEL method provided larger Rv than the PR method: PEL: EA vs CA 87±13 vs 83±11 m-1 (H), 79±13 vs 72±14 m-1 (V); PR: EA vs CA 79±10 vs 67±10 m-1 (H), 71±17 vs 66±12 m-1 (V). Q did not vary significantly with race. Conclusions:Estimates of Rv, but not of Q, varied significantly with race. The greater Rv found in EA than in CA and the comparatively high prevalence rate of myopia in many Asian countries may be related.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Shorter telomere length (TL) has found to be associated with lower birth weight and with lower cognitive ability and psychiatric disorders. However, the direction of causation of these associations and the extent to which they are genetically or environmentally mediated are unclear. Within-pair comparisons of monozygotic (MZ) and dizygotic (DZ) twins can throw light on these questions. We investigated correlations of within pair differences in telomere length, IQ, and anxiety/depression in an initial sample from Brisbane (242 MZ pairs, 245 DZ same sex (DZSS) pairs) and in replication samples from Amsterdam (514 MZ pairs, 233 DZSS pairs) and Melbourne (19 pairs selected for extreme high or low birth weight difference). Intra-pair differences of birth weight and telomere length were significantly correlated in MZ twins, but not in DZSS twins. Greater intra-pair differences of telomere length were observed in the 10% of MZ twins with the greatest difference in birth weight compared to the bottom 90% in both samples and also in the Melbourne sample. Intra-pair differences of telomere length and IQ, but not of TL and anxiety/depression, were correlated in MZ twins, and to a smaller extent in DZSS twins. Our findings suggest that the same prenatal effects that reduce birth weight also influence telomere length in MZ twins. The association between telomere length and IQ is partly driven by the same prenatal effects that decrease birth weight.