3 resultados para Anemometer

em Queensland University of Technology - ePrints Archive


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Wind speed measurement systems are sparse in the tropical regions of Australia. Tropical cyclone wind speeds impacting communities are often ‘guestimated’ from analyzing damaged structures. A re-locatable anemometer system is required to enable measurements of wind speeds. This paper discusses design criteria of the tripods and tie down system, proposed deployment of the anemometers, instrumentation, and data logging. Preliminary assessment of the anemometer response indicates a reliable system for 1 second response, however, it is noted that the Australian building code and wind loading standard uses a moving average time of approximately 0.2 seconds for its wind speed design criteria.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Wind speed measurement systems are sparse in the tropical regions of Australia. Given this, tropical cyclone wind speeds impacting communities are seldom measured and often only ‘guestimated’ by analysing the extent of damage to structures. In an attempt to overcome this dearth of data, a re-locatable network of anemometers to be deployed prior to tropical cyclone landfall is currently being developed. This paper discusses design criteria of the network’s tripods and tie down system, proposed deployment of the anemometers, instrumentation and data logging. Preliminary assessment of the anemometer response indicates a reliable system for measuring the spectral component of wind with frequencies of approximately 1 Hz. This system limitation highlights an important difference between the capabilities of modern instrumentation and that of the Dines anemometer (around 0.2 seconds) that was used to develop much of the design criteria within the Australian building code and wind loading standard.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The wind-speed at a site can be measured by installing anemometers on top of meteorological (met) towers. In addition to other sources of error, accelerated airflow, or speed-up, around the top of met towers can cause incorrect anemometer measurements. We consider a particular example where an anemometer was located only 2 tower diameters above the met tower. Using a standard computational fluid-dynamics package, we found the maximum error for this configuration to be 2% of the wind-speed. We conclude that a top-mounted anemometer should be located at the windward side of its met tower, raised 5 diameters above the top. This will reduce speed-up error to less than 1%.