179 resultados para 660402 Residential and commercial

em Queensland University of Technology - ePrints Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The article explains and compares sustainability programs available for use by residential and commercial premises; as well as the respective legal tenure frameworks of commercial and residential tenancies. It identifies that while the desire of commercial tenants drive the participation by landlords in these programs, residential tenants appear to be ignorant of sustainable measures. The article contends that the reason for this difference is rooted in the legal and social status of residential tenants. It explores the impact that secure tenure may have in promoting residential sustainability programs and concludes by observing that the lack of involvement of residential tenants in programs stems from the absence of tenure security, which prevents any long term cooperation between the parties.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In Bryan v Maloney, the High Court extended a builder’s duty of care to encompass a liability in negligence for the pure economic loss sustained by a subsequent purchaser of a residential dwelling as a result of latent defects in the building’s construction. Recently, in Woolcock Street Investments Pty Ltd v CDG Pty Ltd, the Court refused to extend this liability to defects in commercial premises. The decision therefore provides an opportunity to re-examine the rationale and policy behind current jurisprudence governing builders’ liability for pure economic loss. In doing so, this article considers the principles relevant to the determination of a duty of care generally and whether the differences between purchasers of residential and commercial properties are as great as the case law suggests

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A substantial body of research is focused on understanding the relationships between socio-demographics, land-use characteristics, and mode specific attributes on travel mode choice and time-use patterns. Residential and commercial densities, inter-mixing of land uses, and route directness in conjunction with transportation performance characteristics interact to influence accessibility to destinations as well as time spent traveling and engaging in activities. This study uniquely examines the activity durations undertaken for out-of-home subsistence; maintenance, and discretionary activities. Also examined are total tour durations (summing all activity categories within a tour). Cross-sectional activities are obtained from household activity travel survey data from the Atlanta Metropolitan Region. Time durations allocated to weekdays and weekends are compared. The censoring and endogeneity between activity categories and within individuals are captured using multiple equations Tobit models. The analysis and modeling reveal that land-use characteristics such as net residential density and the number of commercial parcels within a kilometer of a residence are associated with differences in weekday and weekend time-use allocations. Household type and structure are significant predictors across the three activity categories, but not for overall travel times. Tour characteristics such as time-of-day and primary travel mode of the tours also affect traveler's out-of-home activity-tour time-use patterns.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Collaborative user-led content creation by online communities, or produsage (Bruns 2008), has generated a variety of useful and important resources and other valuable outcomes, from open source software through the Wikipedia to a variety of smaller-scale, specialist projects. These are often seen as standing in an inherent opposition to commercial interests, and attempts to develop collaborations between community content creators and commercial partners have had mixed success rates to date. However, such tension between community and commerce is not inevitable, and there is substantial potential for more fruitful exchanges and collaboration. This article contributes to the development of this understanding by outlining the key underlying principles of such participatory community processes and exploring the potential tensions which could arise between these communities and their potential external partners. It also sketches out potential approaches to resolving them.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background There is no legal requirement for Iranian military truck drivers to undergo regular visual checkups as compared to commercial truck drivers. Objectives This study aimed to evaluate the impact of drivers’ visual checkups by comparing the visual function of Iranian military and commercial truck drivers. Patients and Methods In this comparative cross-sectional study, two hundred military and 200 commercial truck drivers were recruited and their Visual Acuity (VA), Visual Field (VF), color vision and Contrast Sensitivity (CS) were assessed and compared using the Snellen chart, confrontation screening method, D15 test and Pelli-Robson letter chart, respectively. A questionnaire regarding driving exposure and history of motor-vehicle crashes (MVCs) was also filled by drivers. Results were analyzed using an independent samples t-test, one-way ANOVA (assessing difference in number of MVCs across different age groups), chi-square test and Pearson correlation at statistical significance level of P < 0.05. Results Mean age was 41.6 ± 9.2 for the military truck drivers and 43.4 ± 10.9 for commercial truck drivers (P > 0.05). No significant difference between military and commercial drivers was found in terms of driving experience, number of MVCs, binocular VA, frequency of color vision defects and CS scores. In contrast, the last ocular examination was significantly earlier in military drivers than commercial drivers (P < 0.001). In addition, 4% of military drivers did not meet the national standards to drive as opposed to 2% of commercial drivers. There was a significant but weak correlation between binocular VA and age (r = 0.175, P < 0.001). However, CS showed a significantly moderate correlation with age (r = -0.488, P < 0.001). Conclusions The absence of legal requirement for regular eye examination in military drivers caused the incompetent drivers to be missed in contrast to commercial drivers. The need for scientific revision of VA standard for Iranian drivers is also discussed. The CS measurement in visual checkups of older drivers deserves to be investigated more thoroughly.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Concrete made of brick chips as coarse aggregate are extensively used in Bangladesh for construction of different types of structures from residential and commercial buildings to industrial complex. As creep is influenced among many factors including the constituents’ materials, relative humidity and temperature, it is essential to examine the creep behavior for Bangladeshi brick chips made concrete in Bangladeshi environment. In this work, investigation on the behaviour of creep in concrete of same grade made with brick chips collected from various locations under single stage loading was done. With these investigations, a formula was derived to get theoretical creep values for 24 MPa brick chips made concrete in Bangladeshi environment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fire safety of light gauge steel frame (LSF) stud walls is important in the design of buildings. Currently LSF walls are increasingly used in the building industry, and are usually made of cold-formed and thin-walled steel studs that are fire-protected by two layers of plasterboard on both sides. Many experimental and numerical studies have been undertaken to investigate the fire performance of load bearing LSF walls under standard fire conditions. However, the standard time-temperature curve does not represent the fire load present in typical residential and commercial buildings that include considerable amount of thermoplastic materials. Real building fires are unlikely to follow a standard time-temperature curve. However, only limited research has been undertaken to investigate the fire performance of load bearing LSF walls under realistic design fire conditions. Therefore in this research, finite element thermal models of the traditional LSF wall panels without cavity insulation and the new LSF composite wall panels were developed to simulate their fire performance under recently developed realistic design fire curves. Suitable thermal properties were proposed for plasterboards and insulations based on laboratory tests and literature review. The developed models were then validated by comparing their thermal performance results with available results from realistic design fire tests, and were later used in parametric studies. This paper presents the details of the developed finite element thermal models of load bearing LSF wall panels under realistic design fire time-temperature curves and the re-sults. It shows that finite element thermal models can be used to predict the fire performance of load bearing LSF walls with varying configurations of insulations and plasterboards under realistic design fires. Failure times of load bearing LSF walls were also predicted based on the results from finite element thermal analyses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Load bearing Light Gauge Steel Frame (LSF) walls made of cold-formed steel studs and tracks are commonly used in residential and commercial buildings. Fire safety of these walls is essential to minimize the damage caused by fire related accidents. Past investigations on the fire performance of load bearing LSF wall systems have been limited to LSF walls made of conventional lipped channel section studs. Although structurally efficient hollow flange steel sections are available in the building industry, they are not used as LSF wall studs due to the lack of fire performance data for such walls. The hollow flange sections have torsionally rigid hollow flanges that eliminate the occurrence of local and distortional buckling to an extent, thereby increasing their structural efficiency. The weaknesses of hollow flange sections such as lower lateral distortional buckling capacity are also eliminated when they are used as studs of LSF walls as the plasterboard restraints will prevent any lateral movement. Therefore hollow flange sections can be considered as structurally more efficient studs for use in LSF wall systems. This paper reports the full scale fire tests of LSF walls made of hollow flange section studs under standard fire conditions. The frames were made of 1.6 mm thick and 150 mm deep hollow flange section studs with two closed rectangular flanges of 45 mm width x 15 mm depth. Dual plasterboards were attached on both sides of the test wall panels. The load ratio was varied and the failure times, the lateral deflections and the axial displacements of the test walls were obtained. The failure behaviour of LSF walls made of hollow flange section studs was found to be different to that of LSF walls made of conventional lipped channel section studs. The results of these fire tests show that hollow flange section studs have a higher potential in being used in load bearing LSF Walls.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cold-formed steel members have been widely used in residential and commercial buildings as primary load bearing structural elements. They are often made of thin steel sheets and hence they are more susceptible to local buckling. The buckling behaviour of cold-formed steel compression members under fire conditions is not fully investigated yet and hence there is a lack of knowledge on the fire performance of cold-formed steel compression members. Current cold-formed steel design standards do not provide adequate design guidelines for the fire design of cold-formed steel compression members. Therefore a research project based on extensive experimental and numerical studies was undertaken to investigate the local buckling behaviour of light gauge cold-formed steel compression members under simulated fire conditions. First a series of 91 local buckling tests was conducted at ambient and uniform elevated temperatures up to 700oC on cold-formed lipped and unlipped channels. Suitable finite element models were then developed to simulate the behaviour of tested columns and were validated using test results. All the ultimate load capacity results for local buckling were compared with the predictions from the available design rules based on AS/NZS 4600, BS 5950 Part 5, Eurocode 3 Parts 1.2 and 1.3 and the direct strength method (DSM), based on which suitable recommendations have been made for the fire design of cold-formed steel compression members subject to local buckling at uniform elevated temperatures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Our built heritage plays an important role in the ongoing story of our city. Modern cities such as Brisbane embraced Art Deco style in its architecture as it swept the world during the interwar period. From inner city landmarks such as the striking McWhirters department store to lesser-known gems further afield like the streamlined Archerfield Airport administration building, Brisbane has a significant range of intriguing and beautiful Art Deco buildings. This publication documents and celebrates a selection of our favourite residential and commercial examples. Written contributions from a range of authors are complemented by stunning modern photography and historic archive imagery, taking readers on a journey through this fascinating era. The articles not only describe the aesthetic and architectural features, but also delve into the associated social history. Brisbane Art Deco: Stories of our Built Heritage is a charming and informative reference, and offers a colourful insight into Brisbane’s built heritage and the life and times of this dynamic city.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Light gauge steel frame (LSF) wall systems are increasingly used in residential and commercial buildings as load bearing and non-load bearing elements. Conventionally, the fire resistance ratings of such building elements are determined using approximate prescriptive methods based on limited standard fire tests. However, recent studies have shown that in some instances real building fire time-temperature curves could be more severe than the standard fire curve, in terms of maximum temperature and rate of temperature rise. This has caused problems for safe evacuation and rescue activities, and in some instances has also lead to the collapse of buildings earlier than the prescribed fire resistance. Therefore a detailed research study into the performance of LSF wall systems under both standard fire and realistic fire conditions was undertaken using full scale fire tests to understand the fire performance of different LSF wall configurations. Both load bearing and non-load bearing full scale fire tests were performed on LSF walls configurations which included single layer, double layer, externally insulated wall panels made up of different steel sections and thicknesses of gypsum plasterboards. The non-load bearing fire test results were utilized to understand the factors affecting the fire resistance of LSF walls, while loading bearing fire test results led to development of simplified methods to predict the fire resistance ratings of load bearing LSF walls exposed to both standard and realistic design fires. This paper presents the results of full scale experimental study and highlights the effects of standard and realistic fire conditions on fire performance of LSF walls.