7 resultados para 21.10.Sf - Coulomb energies
em Queensland University of Technology - ePrints Archive
Resumo:
The effects of tumour motion during radiation therapy delivery have been widely investigated. Motion effects have become increasingly important with the introduction of dynamic radiotherapy delivery modalities such as enhanced dynamic wedges (EDWs) and intensity modulated radiation therapy (IMRT) where a dynamically collimated radiation beam is delivered to the moving target, resulting in dose blurring and interplay effects which are a consequence of the combined tumor and beam motion. Prior to this work, reported studies on the EDW based interplay effects have been restricted to the use of experimental methods for assessing single-field non-fractionated treatments. In this work, the interplay effects have been investigated for EDW treatments. Single and multiple field treatments have been studied using experimental and Monte Carlo (MC) methods. Initially this work experimentally studies interplay effects for single-field non-fractionated EDW treatments, using radiation dosimetry systems placed on a sinusoidaly moving platform. A number of wedge angles (60º, 45º and 15º), field sizes (20 × 20, 10 × 10 and 5 × 5 cm2), amplitudes (10-40 mm in step of 10 mm) and periods (2 s, 3 s, 4.5 s and 6 s) of tumor motion are analysed (using gamma analysis) for parallel and perpendicular motions (where the tumor and jaw motions are either parallel or perpendicular to each other). For parallel motion it was found that both the amplitude and period of tumor motion affect the interplay, this becomes more prominent where the collimator tumor speeds become identical. For perpendicular motion the amplitude of tumor motion is the dominant factor where as varying the period of tumor motion has no observable effect on the dose distribution. The wedge angle results suggest that the use of a large wedge angle generates greater dose variation for both parallel and perpendicular motions. The use of small field size with a large tumor motion results in the loss of wedged dose distribution for both parallel and perpendicular motion. From these single field measurements a motion amplitude and period have been identified which show the poorest agreement between the target motion and dynamic delivery and these are used as the „worst case motion parameters.. The experimental work is then extended to multiple-field fractionated treatments. Here a number of pre-existing, multiple–field, wedged lung plans are delivered to the radiation dosimetry systems, employing the worst case motion parameters. Moreover a four field EDW lung plan (using a 4D CT data set) is delivered to the IMRT quality control phantom with dummy tumor insert over four fractions using the worst case parameters i.e. 40 mm amplitude and 6 s period values. The analysis of the film doses using gamma analysis at 3%-3mm indicate the non averaging of the interplay effects for this particular study with a gamma pass rate of 49%. To enable Monte Carlo modelling of the problem, the DYNJAWS component module (CM) of the BEAMnrc user code is validated and automated. DYNJAWS has been recently introduced to model the dynamic wedges. DYNJAWS is therefore commissioned for 6 MV and 10 MV photon energies. It is shown that this CM can accurately model the EDWs for a number of wedge angles and field sizes. The dynamic and step and shoot modes of the CM are compared for their accuracy in modelling the EDW. It is shown that dynamic mode is more accurate. An automation of the DYNJAWS specific input file has been carried out. This file specifies the probability of selection of a subfield and the respective jaw coordinates. This automation simplifies the generation of the BEAMnrc input files for DYNJAWS. The DYNJAWS commissioned model is then used to study multiple field EDW treatments using MC methods. The 4D CT data of an IMRT phantom with the dummy tumor is used to produce a set of Monte Carlo simulation phantoms, onto which the delivery of single field and multiple field EDW treatments is simulated. A number of static and motion multiple field EDW plans have been simulated. The comparison of dose volume histograms (DVHs) and gamma volume histograms (GVHs) for four field EDW treatments (where the collimator and patient motion is in the same direction) using small (15º) and large wedge angles (60º) indicates a greater mismatch between the static and motion cases for the large wedge angle. Finally, to use gel dosimetry as a validation tool, a new technique called the „zero-scan method. is developed for reading the gel dosimeters with x-ray computed tomography (CT). It has been shown that multiple scans of a gel dosimeter (in this case 360 scans) can be used to reconstruct a zero scan image. This zero scan image has a similar precision to an image obtained by averaging the CT images, without the additional dose delivered by the CT scans. In this investigation the interplay effects have been studied for single and multiple field fractionated EDW treatments using experimental and Monte Carlo methods. For using the Monte Carlo methods the DYNJAWS component module of the BEAMnrc code has been validated and automated and further used to study the interplay for multiple field EDW treatments. Zero-scan method, a new gel dosimetry readout technique has been developed for reading the gel images using x-ray CT without losing the precision and accuracy.
Resumo:
Residual amplitude modulation (RAM) is an unwanted noise source in electro-optic phase modulators. The analysis presented shows that while the magnitude of the RAM produced by a MgO:LiNbO3 modulator increases with intensity, its associated phase becomes less well defined. This combination results in temporal fluctuations in RAM that increase with intensity. This behaviour is explained by the presented phenomenological model based on gradually evolving photorefractive scattering centres randomly distributed throughout the optically thick medium. This understanding is exploited to show that RAM can be reduced to below the 10-5 level by introducing an intense optical beam to erase the photorefractive scatter.
Resumo:
This article examines the decisions in Galway v Constable [2001] QSC 180 and Mazelow Pty Ltd v Herberton Shire Council [2001] QSC 250
Resumo:
Background Cancer and its treatments produce lingering side-effects that undermine the quality of life (QOL) of survivors. Exercise and psycho-therapies increase QOL among survivors, however, research is needed to identify intervention characteristics most associated with such improvements. Objective This research aimed to assess the feasibility of a 9 week individual or group based exercise and counselling program, and to examine if a group based intervention is as effective at improving the QOL of breast cancer survivors as an individual-based intervention. Methods A three group design was implemented to compare the efficacy of a 9 week individual (IEC n = 12) and group based exercise and counselling (GEC n = 14) intervention to a usual care (UsC n = 10) group on QOL of thirty-six breast cancer survivors. Results Across all groups, 90% of participants completed the interventions, with no adverse effects documented. At the completion of the intervention, there was a significant difference between groups for change in global QOL across time (p < 0.023), with IEC improving significantly more (15.0 points) than the UsC group (1.8 points). The effect size was moderate (0.70). Although the GEC improved QOL by almost 10.0 points, this increase did not reach significance. Both increases were above the minimally important difference of 7–8 points. Conclusion These preliminary results suggest a combined exercise and psychological counseling program is both a feasible and acceptable intervention for breast cancer survivors. Whilst both the individual and group interventions improved QOL above the clinically important difference, only the individual based intervention was significant when compared to UsC.
Resumo:
Complementary experiments and numerical modeling reveal the important role of photo-ionization in the guided streamer propagation in helium-air gas mixtures. It is shown that the minimum electron concentration ∼108 cm−3 is required for the regular, repeated propagation of the plasma bullets, while the streamers propagate in the stochastic mode below this threshold. The stochastic-to-regular mode transition is related to the higher background electron density in front of the propagating streamers. These findings help improving control of guided streamer propagation in applications from health care to nanotechnology and improve understanding of generic pre-breakdown phenomena.
Resumo:
Telomere length (TL) has been associated with aging and mortality, but individual differences are also influenced by genetic factors, with previous studies reporting heritability estimates ranging from 34 to 82%. Here we investigate the heritability, mode of inheritance and the influence of parental age at birth on TL in six large, independent cohort studies with a total of 19 713 participants. The meta-analysis estimate of TL heritability was 0.70 (95% CI 0.64–0.76) and is based on a pattern of results that is highly similar for twins and other family members. We observed a stronger mother–offspring (r=0.42; P-value=3.60 × 10−61) than father–offspring correlation (r=0.33; P-value=7.01 × 10−5), and a significant positive association with paternal age at offspring birth (β=0.005; P-value=7.01 × 10−5). Interestingly, a significant and quite substantial correlation in TL between spouses (r=0.25; P-value=2.82 × 10−30) was seen, which appeared stronger in older spouse pairs (mean age ≥55 years; r=0.31; P-value=4.27 × 10−23) than in younger pairs (mean age<55 years; r=0.20; P-value=3.24 × 10−10). In summary, we find a high and very consistent heritability estimate for TL, evidence for a maternal inheritance component and a positive association with paternal age.