8 resultados para 1232
em Queensland University of Technology - ePrints Archive
Resumo:
When the supply voltages are balanced and sinusoidal, load compensation can give both unity power factor (UPF) and perfect harmonic cancellation (PHC) source currents. But under distorted supply voltages, achieving both UPF and PHC currents are not possible and contradictory to each other. Hence there should be an optimal performance between these two important compensation goals. This paper presents an optimal control algorithm for load compensation under unbalanced and distorted supply voltages. In this algorithm source currents are compensated for reactive, imbalance components and harmonic distortions set by the limits. By satisfying the harmonic distortion limits and power balance, this algorithm gives the source currents which will provide the maximum achievable power factor. The detailed simulation results using MATLAB are presented to support the performance of the proposed optimal control algorithm.
Resumo:
Hazard perception in driving involves a number of different processes. This paper reports the development of two measures designed to separate these processes. A Hazard Perception Test was developed to measure how quickly drivers could anticipate hazards overall, incorporating detection, trajectory prediction, and hazard classification judgements. A Hazard Change Detection Task was developed to measure how quickly drivers can detect a hazard in a static image regardless of whether they consider it hazardous or not. For the Hazard Perception Test, young novices were slower than mid-age experienced drivers, consistent with differences in crash risk, and test performance correlated with scores in pre-existing Hazard Perception Tests. For drivers aged 65 and over, scores on the Hazard Perception Test declined with age and correlated with both contrast sensitivity and a Useful Field of View measure. For the Hazard Change Detection Task, novices responded quicker than the experienced drivers, contrary to crash risk trends, and test performance did not correlate with measures of overall hazard perception. However for drivers aged 65 and over, test performance declined with age and correlated with both hazard perception and Useful Field of View. Overall we concluded that there was support for the validity of the Hazard Perception Test for all ages but the Hazard Change Detection Task might only be appropriate for use with older drivers.
Resumo:
Utilization of multiport-antennas represents an appropriate way for the mitigation of multi-path fading in wireless communication systems. However, to obtain low correlation between the signals from different antenna ports and to prevent gain reduction by cross-talk, large antenna elements spacing is expected. Polarization diversity allows signal separation even with small antenna spacing. Although it is effective, polarization diversity alone does not suffice once the number of antennas exceeds the number of orthogonal polarizations. This paper presents an approach which combines a novel array concept with the use of dual polarization. The theory is verified by a compact dual polarized patch antenna array, which consists of four elements and a decoupling network.
Resumo:
RNA interference induced in insects after ingestion of plant-expressed hairpin RNA offers promise for managing devastating crop pests
Resumo:
Structural investigations of large biomolecules in the gas phase are challenging. Herein, it is reported that action spectroscopy taking advantage of facile carbon-iodine bond dissociation can be used to examine the structures of large molecules, including whole proteins. Iodotyrosine serves as the active chromophore, which yields distinctive spectra depending on the solvation of the side chain by the remainder of the molecule. Isolation of the chromophore yields a double featured peak at ∼290 nm, which becomes a single peak with increasing solvation. Deprotonation of the side chain also leads to reduced apparent intensity and broadening of the action spectrum. The method can be successfully applied to both negatively and positively charged ions in various charge states, although electron detachment becomes a competitive channel for multiply charged anions. In all other cases, loss of iodine is by far the dominant channel which leads to high sensitivity and simple data analysis. The action spectra for iodotyrosine, the iodinated peptides KGYDAKA, DAYLDAG, and the small protein ubiquitin are reported in various charge states. © 2012 American Chemical Society.
Resumo:
Matrix converter (MC) based bi-directional inductive power transfer (BD-IPT) systems are gaining popularity as an efficient and reliable technique with single stage grid integration as opposed to two stage grid integration of conventional grid connected BD-IPT systems. However MCs are invariably rich in harmonics and thus affect both power quality and power factor on the grid side. This paper proposes a mathematical model through which the grid side harmonics of MC based BD-IPT systems can accurately be estimated. The validity of the proposed mathematical model is verified using simulated results of a 3 kW BD-IPT system and results suggest that the MC based BD-IPT systems have a better power factor with higher power quality over conventional grid connected rectifier based systems.
Resumo:
Empirical evidence suggests impaired facial emotion recognition in schizophrenia. However, the nature of this deficit is the subject of ongoing research. The current study tested the hypothesis that a generalized deficit at an early stage of face-specific processing (i.e. putatively subserved by the fusiform gyrus) accounts for impaired facial emotion recognition in schizophrenia as opposed to the Negative Emotion-specific Deficit Model, which suggests impaired facial information processing at subsequent stages. Event-related potentials (ERPs) were recorded from 11 schizophrenia patients and 15 matched controls while performing a gender discrimination and a facial emotion recognition task. Significant reduction of the face-specific vertex positive potential (VPP) at a peak latency of 165 ms was confirmed in schizophrenia subjects whereas their early visual processing, as indexed by P1, was found to be intact. Attenuated VPP was found to correlate with subsequent P3 amplitude reduction and to predict accuracy when performing a facial emotion discrimination task. A subset of ten schizophrenia patients and ten matched healthy control subjects also performed similar tasks in the magnetic resonance imaging scanner. Patients showed reduced blood oxygenation level-dependent (BOLD) activation in the fusiform, inferior frontal, middle temporal and middle occipital gyrus as well as in the amygdala. Correlation analyses revealed that VPP and the subsequent P3a ERP components predict fusiform gyrus BOLD activation. These results suggest that problems in facial affect recognition in schizophrenia may represent flow-on effects of a generalized deficit in early visual processing.
Resumo:
Background Little is known about the relation between vitamin D status in early life and neurodevelopment outcomes. Objective This study was designed to examine the association of cord blood 25-hydroxyvitamin D [25(OH)D] at birth with neurocognitive development in toddlers. Methods As part of the China-Anhui Birth Cohort Study, 363 mother-infant pairs with completed data were selected. Concentrations of 25(OH)D in cord blood were measured by radioimmunoassay. Mental development index (MDI) and psychomotor development index (PDI) in toddlers were assessed at age 16–18 mo by using the Bayley Scales of Infant Development. The data on maternal sociodemographic characteristics and other confounding factors were also prospectively collected. Results Toddlers in the lowest quintile of cord blood 25(OH)D exhibited a deficit of 7.60 (95% CI: −12.4, −2.82; P = 0.002) and 8.04 (95% CI: −12.9, −3.11; P = 0.001) points in the MDI and PDI scores, respectively, compared with the reference category. Unexpectedly, toddlers in the highest quintile of cord blood 25(OH)D also had a significant deficit of 12.3 (95% CI: −17.9, −6.67; P < 0.001) points in PDI scores compared with the reference category. Conclusions This prospective study suggested that there was an inverted-U–shaped relation between neonatal vitamin D status and neurocognitive development in toddlers. Additional studies on the optimal 25(OH)D concentrations in early life are needed.