353 resultados para wide angle scanning phased array


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Utilization of multiport-antennas represents an appropriate way for the mitigation of multi-path fading in wireless communication systems. However, to obtain low correlation between the signals from different antenna ports and to prevent gain reduction by cross-talk, large antenna elements spacing is expected. Polarization diversity allows signal separation even with small antenna spacing. Although it is effective, polarization diversity alone does not suffice once the number of antennas exceeds the number of orthogonal polarizations. This paper presents an approach which combines a novel array concept with the use of dual polarization. The theory is verified by a compact dual polarized patch antenna array, which consists of four elements and a decoupling network.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

3D models of long bones are being utilised for a number of fields including orthopaedic implant design. Accurate reconstruction of 3D models is of utmost importance to design accurate implants to allow achieving a good alignment between two bone fragments. Thus for this purpose, CT scanners are employed to acquire accurate bone data exposing an individual to a high amount of ionising radiation. Magnetic resonance imaging (MRI) has been shown to be a potential alternative to computed tomography (CT) for scanning of volunteers for 3D reconstruction of long bones, essentially avoiding the high radiation dose from CT. In MRI imaging of long bones, the artefacts due to random movements of the skeletal system create challenges for researchers as they generate inaccuracies in the 3D models generated by using data sets containing such artefacts. One of the defects that have been observed during an initial study is the lateral shift artefact occurring in the reconstructed 3D models. This artefact is believed to result from volunteers moving the leg during two successive scanning stages (the lower limb has to be scanned in at least five stages due to the limited scanning length of the scanner). As this artefact creates inaccuracies in the implants designed using these models, it needs to be corrected before the application of 3D models to implant design. Therefore, this study aimed to correct the lateral shift artefact using 3D modelling techniques. The femora of five ovine hind limbs were scanned with a 3T MRI scanner using a 3D vibe based protocol. The scanning was conducted in two halves, while maintaining a good overlap between them. A lateral shift was generated by moving the limb several millimetres between two scanning stages. The 3D models were reconstructed using a multi threshold segmentation method. The correction of the artefact was achieved by aligning the two halves using the robust iterative closest point (ICP) algorithm, with the help of the overlapping region between the two. The models with the corrected artefact were compared with the reference model generated by CT scanning of the same sample. The results indicate that the correction of the artefact was achieved with an average deviation of 0.32 ± 0.02 mm between the corrected model and the reference model. In comparison, the model obtained from a single MRI scan generated an average error of 0.25 ± 0.02 mm when compared with the reference model. An average deviation of 0.34 ± 0.04 mm was seen when the models generated after the table was moved were compared to the reference models; thus, the movement of the table is also a contributing factor to the motion artefacts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hamstring strain injuries are amongst the most common and problematic injuries in a wide range of sports that involve high speed running. The comparatively high rate of hamstring injury recurrence is arguably the most concerning aspect of these injuries. A number of modifiable and nonmodifiable risk factors are proposed to predispose athletes to hamstring strains. Potentially, the persistence of risk factors and the development of maladaptations following injury may explain injury recurrence. Here, the role of neuromuscular inhibition following injury is discussed as a potential mechanism for several maladaptations associated with hamstring re-injury. These maladaptations include eccentric hamstring weakness, selective hamstring atrophy and shifts in the knee flexor torque-joint angle relationship. Current evidence indicates that athletes return to competition after hamstring injury having developed maladaptations that predispose them to further injury. When rehabilitating athletes to return to competition following hamstring strain injury, the role of neuromuscular inhibition in re-injury should be considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fast calculation of quantities such as in-cylinder volume and indicated power is important in internal combustion engine research. Multiple channels of data including crank angle and pressure were collected for this purpose using a fully instrumented diesel engine research facility. Currently, existing methods use software to post-process the data, first calculating volume from crank angle, then calculating the indicated work and indicated power from the area enclosed by the pressure-volume indicator diagram. Instead, this work investigates the feasibility of achieving real-time calculation of volume and power via hardware implementation on Field Programmable Gate Arrays (FPGAs). Alternative hardware implementations were investigated using lookup tables, Taylor series methods or the CORDIC (CoOrdinate Rotation DIgital Computer) algorithm to compute the trigonometric operations in the crank angle to volume calculation, and the CORDIC algorithm was found to use the least amount of resources. Simulation of the hardware based implementation showed that the error in the volume and indicated power is less than 0.1%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents an analytical model to study the effect of stiffening ribs on vibration transmission between two rectangular plates coupled at right angle. Interesting wave attenuation patterns were observed by placing the stiffening rib either on the source or on the receiving plate. The result can be used to improve the understanding of vibration and for vibration control of more complex structures such as transformer tanks and machine covers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This is the protocol for a review and there is no abstract. The objectives are as follows: Primary research objective To determine the effects of community wide, multi-strategic interventions upon community levels of physical activity. Secondary research objectives 1. To explore whether any effects of the intervention are different within and between populations, and whether these differences form an equity gradient. 2. To describe other health (e.g. cardiovascular disease morbidity) and behavioural effects (e.g. diet) where appropriate outcomes are available. 3. To explore the influence of context in the design, delivery, and outcomes of the interventions. 4. To explore the relationship between the number of components, duration, and effects of the interventions. 5. To highlight implications for further research and research methods to improve knowledge of the interventions in relation to the primary research objective.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Passive air samplers (PAS) consisting of polyurethane foam (PUF) disks were deployed at 6 outdoor air monitoring stations in different land use categories (commercial, industrial, residential and semi-rural) to assess the spatial distribution of polybrominated diphenyl ethers (PBDEs) in the Brisbane airshed. Air monitoring sites covered an area of 1143 km2 and PAS were allowed to accumulate PBDEs in the city's airshed over three consecutive seasons commencing in the winter of 2008. The average sum of five (∑5) PBDEs (BDEs 28, 47, 99, 100 and 209) levels were highest at the commercial and industrial sites (12.7 ± 5.2 ng PUF−1), which were relatively close to the city center and were a factor of 8 times higher than residential and semi-rural sites located in outer Brisbane. To estimate the magnitude of the urban ‘plume’ an empirical exponential decay model was used to fit PAS data vs. distance from the CBD, with the best correlation observed when the particulate bound BDE-209 was not included (∑5-209) (r2 = 0.99), rather than ∑5 (r2 = 0.84). At 95% confidence intervals the model predicts that regardless of site characterization, ∑5-209 concentrations in a PAS sample taken between 4–10 km from the city centre would be half that from a sample taken from the city centre and reach a baseline or plateau (0.6 to 1.3 ng PUF−1), approximately 30 km from the CBD. The observed exponential decay in ∑5-209 levels over distance corresponded with Brisbane's decreasing population density (persons/km2) from the city center. The residual error associated with the model increased significantly when including BDE-209 levels, primarily due to the highest level (11.4 ± 1.8 ng PUF−1) being consistently detected at the industrial site, indicating a potential primary source at this site. Active air samples collected alongside the PAS at the industrial air monitoring site (B) indicated BDE-209 dominated congener composition and was entirely associated with the particulate phase. This study demonstrates that PAS are effective tools for monitoring citywide regional differences however, interpretation of spatial trends for POPs which are predominantly associated with the particulate phase such as BDE-209, may be restricted to identifying ‘hotspots’ rather than broad spatial trends.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Genome-wide association studies (GWAS) have identified multiple common genetic variants associated with an increased risk of prostate cancer (PrCa), but these explain less than one-third of the heritability. To identify further susceptibility alleles, we conducted a meta-analysis of four GWAS including 5953 cases of aggressive PrCa and 11 463 controls (men without PrCa). We computed association tests for approximately 2.6 million SNPs and followed up the most significant SNPs by genotyping 49 121 samples in 29 studies through the international PRACTICAL and BPC3 consortia. We not only confirmed the association of a PrCa susceptibility locus, rs11672691 on chromosome 19, but also showed an association with aggressive PrCa [odds ratio = 1.12 (95% confidence interval 1.03-1.21), P = 1.4 × 10(-8)]. This report describes a genetic variant which is associated with aggressive PrCa, which is a type of PrCa associated with a poorer prognosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Prostate cancer is the most frequently diagnosed cancer in males in developed countries. To identify common prostate cancer susceptibility alleles, we genotyped 211,155 SNPs on a custom Illumina array (iCOGS) in blood DNA from 25,074 prostate cancer cases and 24,272 controls from the international PRACTICAL Consortium. Twenty-three new prostate cancer susceptibility loci were identified at genome-wide significance (P < 5 × 10−8). More than 70 prostate cancer susceptibility loci, explaining ~30% of the familial risk for this disease, have now been identified. On the basis of combined risks conferred by the new and previously known risk loci, the top 1% of the risk distribution has a 4.7-fold higher risk than the average of the population being profiled. These results will facilitate population risk stratification for clinical studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The feasibility of real-time calculation of parameters for an internal combustion engine via reconfigurable hardware implementation is investigated as an alternative to software computation. A detailed in-hardware field programmable gate array (FPGA)-based design is developed and evaluated using input crank angle and in-cylinder pressure data from fully instrumented diesel engines in the QUT Biofuel Engine Research Facility (BERF). Results indicate the feasibility of employing a hardware-based implementation for real-time processing for speeds comparable to the data sampling rate currently used in the facility, with acceptably low level of discrepancies between hardware and software-based calculation of key engine parameters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Experiments were carried out on the sodium hypochlorite bleach sensitivity of a deep subsurface andesitic reservoir in order to predict possible deleterious mineral transformations during a downhole clean-up job. Experiments involved examination of core samples from the reservoir using an Environmental Scanning Electron Microscope (ESEM) with an attached Energy Dispersive Spectrometer (EDS) before and after the samples were immersed in bleach. Bleach immersion of whole-rock samples resulted in rapid (less than 1 min) precipitation of abundant 3.0-10.0-μm-wide calcite rhombs within clay-associated micropores and on clay and feldspar grain surfaces. Abundant microporefilling calcite rhombs also formed in pure separates of constituent chlorite/corrensite, whereas no calcite formed in a pure separate of constituent zeolite. These experiments indicate that corrensite is the likely calcium source in this experimental fluid-rock system. Formation of calcite occurs via a cation exchange reaction in which calcium in the smectitic interlayers of corrensite exchanges for sodium in the bleach. Serious formation damage due to calcite precipitation would have occurred in the andesite reservoir had it been exposed to bleach. This finding gives credence to earlier suggestions that cation exchange reactions have the potential to cause calcite precipitation in some sandstone reservoirs when exposed to drilling, completion or stimulation fluids. © 1993.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The future emergence of many types of airborne vehicles and unpiloted aircraft in the national airspace means collision avoidance is of primary concern in an uncooperative airspace environment. The ability to replicate a pilot’s see and avoid capability using cameras coupled with vision based avoidance control is an important part of an overall collision avoidance strategy. But unfortunately without range collision avoidance has no direct way to guarantee a level of safety. Collision scenario flight tests with two aircraft and a monocular camera threat detection and tracking system were used to study the accuracy of image-derived angle measurements. The effect of image-derived angle errors on reactive vision-based avoidance performance was then studied by simulation. The results show that whilst large angle measurement errors can significantly affect minimum ranging characteristics across a variety of initial conditions and closing speeds, the minimum range is always bounded and a collision never occurs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Evaluating the effectiveness of interventions designed to increase the physical activity in communities is often a difficult and complex task, requiring considerable expertise and investment, and often constrained by methodological limitations. These limitations, in turn, create additional challenges when these studies are used in systematic reviews as they hinder the confidence, precision and interpretation of results. The objective of this paper is to summarise the methodological challenges posed in conducting a systematic review of community-wide physical activity interventions to help inform those conducting future primary research and systematic reviews. Methods: We conducted a Cochrane systematic review of community-wide interventions to increase physical activity. We assessed the methodological quality of the included studies. We will investigate these in greater detail, particularly in relation to the potential impact on measures of effect, confidence in results, generalizability of results and general interpretation. Results: The systematic review was conducted and has been published in the Cochrane Library. A logic model was helpful in defining and interpreting the studies. Many studies of unsuitable study design were excluded; however several important methodological limitations of the primary studies evaluating community-wide physical activity interventions emerged. These included: - the failure to use validated tools to measure physical activity; - issues associated with pre and post test designs; - inadequate sampling of populations; - poor control groups; and - intervention and measurement protocols of inadequate duration. Although it is challenging to undertake rigorous evaluations of complex interventions, these issues result in significant uncertainty over the effectiveness of these interventions, and the possible factors required for a community-wide intervention to be successful. In particular, the combination of several of these limitations (e.g. un-validated tools, inadequate sampling, and short duration) is that studies may lack the sensitivity to detect any meaningful change. Multiple publications of findings for the same study also made interpretation difficult; however, interventions with parallel qualitative publications were helpful. Discussion: Evaluating community wide interventions to increase physical activity in a rigorous way is incredibly challenging. These findings reflect these challenges but have important ramifications for researchers conducting primary studies to determine the efficacy of such interventions, as well as for researchers conducting systematic reviews. This new review shows that the inadequacies of design and evaluation are continuing. It is hoped that the adoption of such suggestions may aid in the development of systematic reviews, but more importantly, in enabling translation of such findings into policy and practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High magnification and large depth of field with a temporal resolution of less than 100 microseconds are possible using the present invention which combines a linear electron beam produced by a tungsten filament from an SX-40A Scanning Electron Microscope (SEM), a magnetic deflection coil with lower inductance resulting from reducing the number of turns of the saddle-coil wires, while increasing the diameter of the wires, a fast scintillator, photomultiplier tube, photomultiplier tube base, and signal amplifiers and a high speed data acquisition system which allows for a scan rate of 381 frames per second and 256.times.128 pixel density in the SEM image at a data acquisition rate of 25 MHz. The data acquisition and scan position are fully coordinated. A digitizer and a digital waveform generator which generates the sweep signals to the scan coils run off the same clock to acquire the signal in real-time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Small-angle and ultra-small-angle neutron scattering (SANS and USANS), low-pressure adsorption (N2 and CO2), and high-pressure mercury intrusion measurements were performed on a suite of North American shale reservoir samples providing the first ever comparison of all these techniques for characterizing the complex pore structure of shales. The techniques were used to gain insight into the nature of the pore structure including pore geometry, pore size distribution and accessible versus inaccessible porosity. Reservoir samples for analysis were taken from currently-active shale gas plays including the Barnett, Marcellus, Haynesville, Eagle Ford, Woodford, Muskwa, and Duvernay shales. Low-pressure adsorption revealed strong differences in BET surface area and pore volumes for the sample suite, consistent with variability in composition of the samples. The combination of CO2 and N2 adsorption data allowed pore size distributions to be created for micro–meso–macroporosity up to a limit of �1000 Å. Pore size distributions are either uni- or multi-modal. The adsorption-derived pore size distributions for some samples are inconsistent with mercury intrusion data, likely owing to a combination of grain compression during high-pressure intrusion, and the fact that mercury intrusion yields information about pore throat rather than pore body distributions. SANS/USANS scattering data indicate a fractal geometry (power-law scattering) for a wide range of pore sizes and provide evidence that nanometer-scale spatial ordering occurs in lower mesopore–micropore range for some samples, which may be associated with inter-layer spacing in clay minerals. SANS/USANS pore radius distributions were converted to pore volume distributions for direct comparison with adsorption data. For the overlap region between the two methods, the agreement is quite good. Accessible porosity in the pore size (radius) range 5 nm–10 lm was determined for a Barnett shale sample using the contrast matching method with pressurized deuterated methane fluid. The results demonstrate that accessible porosity is pore-size dependent.