144 resultados para USED CARS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many cyclist deaths and serious injuries result from rear-end or sideswipe collisions involving a car or heavy vehicle. As a consequence, minimum passing distance laws (often referred to as ‘one metre rules’) have been introduced in a number of U.S. states along with European countries such as France, Belgium and Spain. A two-year trial of a minimum passing distance rule is underway in Queensland. The international studies show that while the average passing distance is more than one metre, significant proportions of passes occur at less than this distance. Average passing distances are greater with wider lanes, when bicycle lanes are present, for cars rather than vans or trucks, and (possibly) at higher speed limits. Perceived characteristics of the cyclist (other than gender) appear to have little effect on passing distances. The research questions the ability to judge lateral distance and whether nominated distances predict on-road behaviour. Cyclists have strong concerns about drivers passing too close but the extent to which this behaviour reflects deliberate intimidation versus an inability to judge what is a safe passing distance is not clear. There has been no systematic evaluation of the road safety benefits of minimum passing distance laws. These laws have received little police enforcement but it is unclear whether enforcement is necessary for them to be effective.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract: A strategy that is often used for designing low band gap polymers involves the incorporation of electron-rich (donor) and electron-deficient (acceptor) conjugated segments within the polymer backbone. In this paper we investigate such a series of Diketopyrrolopyrrole (DPP)-based co-polymers. The co-polymers consisted of a DPP unit attached to a phenylene, naphthalene, or anthracene unit. Additionally, polymers utilizing either the thiophene-flanked DPP or the furan-flanked DPP units paired with the naphthalene comonomer were compared. As these polymers have been used as donor materials and subsequent hole transporting materials in organic solar cells, we are specifically interested in characterizing the optical absorption of the hole polaron of these DPP based copolymers. We employ chemical doping, electrochemical doping, and photoinduced absorption (PIA) studies to probe the hole polaron absorption spectra. While some donor-acceptor polymers have shown an appreciable capacity to generate free charge carriers upon photoexcitation, no polaron signal was observed in the PIA spectrum of the polymers in this study. The relations between molecular structure and optical properties are discussed. Keywords: organic solar cell; organic photovoltaic; diketopyrrolopyrrole; chemical doping; spectroelectrochemistry; photoinduced absorption; hole polaron

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Integration of biometrics is considered as an attractive solution for the issues associated with password based human authentication as well as for secure storage and release of cryptographic keys which is one of the critical issues associated with modern cryptography. However, the widespread popularity of bio-cryptographic solutions are somewhat restricted by the fuzziness associated with biometric measurements. Therefore, error control mechanisms must be adopted to make sure that fuzziness of biometric inputs can be sufficiently countered. In this paper, we have outlined such existing techniques used in bio-cryptography while explaining how they are deployed in different types of solutions. Finally, we have elaborated on the important facts to be considered when choosing appropriate error correction mechanisms for a particular biometric based solution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Map-matching algorithms that utilise road segment connectivity along with other data (i.e.position, speed and heading) in the process of map-matching are normally suitable for high frequency (1 Hz or higher) positioning data from GPS. While applying such map-matching algorithms to low frequency data (such as data from a fleet of private cars, buses or light duty vehicles or smartphones), the performance of these algorithms reduces to in the region of 70% in terms of correct link identification, especially in urban and sub-urban road networks. This level of performance may be insufficient for some real-time Intelligent Transport System (ITS) applications and services such as estimating link travel time and speed from low frequency GPS data. Therefore, this paper develops a new weight-based shortest path and vehicle trajectory aided map-matching (stMM) algorithm that enhances the map-matching of low frequency positioning data on a road map. The well-known A* search algorithm is employed to derive the shortest path between two points while taking into account both link connectivity and turn restrictions at junctions. In the developed stMM algorithm, two additional weights related to the shortest path and vehicle trajectory are considered: one shortest path-based weight is related to the distance along the shortest path and the distance along the vehicle trajectory, while the other is associated with the heading difference of the vehicle trajectory. The developed stMM algorithm is tested using a series of real-world datasets of varying frequencies (i.e. 1 s, 5 s, 30 s, 60 s sampling intervals). A high-accuracy integrated navigation system (a high-grade inertial navigation system and a carrier-phase GPS receiver) is used to measure the accuracy of the developed algorithm. The results suggest that the algorithm identifies 98.9% of the links correctly for every 30 s GPS data. Omitting the information from the shortest path and vehicle trajectory, the accuracy of the algorithm reduces to about 73% in terms of correct link identification. The algorithm can process on average 50 positioning fixes per second making it suitable for real-time ITS applications and services.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Wechsler and Stanford Binet scales are among the most commonly used tests of intelligence. In clinical practice, they often seem to be used interchangeably. This paper reports the results of two studies that compared the most recent editions of two Wechsler scales (WPPSI-III and WISC-IV) with the Stanford-Binet Fifth Edition (SB5). The participants in the first study were 36 typically developing 4-year-old children who completed the WPPSI-III and SB5 in counter-balanced order. Although correlations of composite scores ranged from r = .59 to r = .82 and were similar to those reported for earlier versions of the two instruments, more than half the sample had a score discrepancy greater than 10 points across the two instruments. In the second study, the WISC-IV and SB5 were administered to 30 children aged 12-14 years. There was a significant difference between Full Scale IQs on the two measures, with scores being higher on the WISC-IV. Differences between the two verbal scales were also significant and favoured the WISC-IV. There were moderate correlations of Full Scale IQs (r = .58) and Nonverbal IQs (r = .54) but the relationship between the two Verbal scales was not significant. For some children, notable score differences led to different categorisations of their level of intellectual ability The findings suggest that the Wechsler and Stanford Binet scales cannot be presumed to be interchangeable. The discussion focuses on how psychologists might reconcile large differences in test scores and the need for caution when interpreting and comparing test results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background The capacity to diagnosys, quantify and evaluate movement beyond the general confines of a clinical environment under effectiveness conditions may alleviate rampant strain on limited, expensive and highly specialized medical resources. An iPhone 4® mounted a three dimensional accelerometer subsystem with highly robust software applications. The present study aimed to evaluate the reliability and concurrent criterion-related validity of the accelerations with an iPhone 4® in an Extended Timed Get Up and Go test. Extended Timed Get Up and Go is a clinical test with that the patient get up from the chair and walking ten meters, turn and coming back to the chair. Methods A repeated measure, cross-sectional, analytical study. Test-retest reliability of the kinematic measurements of the iPhone 4® compared with a standard validated laboratory device. We calculated the Coefficient of Multiple Correlation between the two sensors acceleration signal of each subject, in each sub-stage, in each of the three Extended Timed Get Up and Go test trials. To investigate statistical agreement between the two sensors we used the Bland-Altman method. Results With respect to the analysis of the correlation data in the present work, the Coefficient of Multiple Correlation of the five subjects in their triplicated trials were as follows: in sub-phase Sit to Stand the ranged between r = 0.991 to 0.842; in Gait Go, r = 0.967 to 0.852; in Turn, 0.979 to 0.798; in Gait Come, 0.964 to 0.887; and in Turn to Stand to Sit, 0.992 to 0.877. All the correlations between the sensors were significant (p < 0.001). The Bland-Altman plots obtained showed a solid tendency to stay at close to zero, especially on the y and x-axes, during the five phases of the Extended Timed Get Up and Go test. Conclusions The inertial sensor mounted in the iPhone 4® is sufficiently reliable and accurate to evaluate and identify the kinematic patterns in an Extended Timed Get and Go test. While analysis and interpretation of 3D kinematics data continue to be dauntingly complex, the iPhone 4® makes the task of acquiring the data relatively inexpensive and easy to use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective The objective of this study was to determine the roadside prevalence of alcohol-impaired driving among drivers and riders in northern Ghana. The study also verifies motorists’ perception on their own alcohol use and knowledge of legal Blood Alcohol Concentration (BAC) limit of Ghana. Method With the assistance of police, the systematic random sampling was used to collect data at roadblocks using a cross-sectional study design. Breathalyzers were used to screen whether motorists had detectable alcohol in their breath and a follow-up breath tests conducted to measure the actual breath alcohol levels among positive participants. Results In all, 9.7% of the 789 participants had detectable alcohol among whom 6% exceeded the legal (BAC) limit of 0.08%. The prevalence of alcohol-impaired driving/riding was highest among cyclists (10% of all cyclists breath tested) followed by truck drivers 9% and motorcyclists (7% of all motorcyclists breath tested). The occurrence of a positive BAC among cyclists was about 8 times higher, (OR=7.73; p<0.001) and 2 times higher, among motorcyclists (OR=2.30; p=0.039) compared with private car drivers. The likelihood for detecting a positive BAC among male motorists/riders was higher than females (OR=1.67; p=0.354). The odds for detecting a positive BAC among weekend motorists/riders was significantly higher than weekdays (OR=2.62; p=0.001). Conclusion Alcohol-impaired driving/riding in Ghana is high by international standards. In order to attenuate the harmful effects of alcohol misuse such as alcohol-impaired driving/riding, there is the need to educate road users about how much alcohol they can consume and stay below the legal limit. The police should also initiate random breath testing to instil the deterrence of detection, certainty of apprehension and punishment, and severity and celerity of punishment among drink-driving motorists and riders.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The extreme diversity of conditions acting on railways necessitates a variety of experimental approaches to study the critical wear mechanisms that present themselves at the contact interface. This work investigates the effects of contact pressure and geometry in rolling-contact wear tests by using discs with different radii of curvature to simulate the varying contact conditions that may be typically found in the field. It is commonly adapted to line contact interface as it has constant contact pressure. But practical scenario of the rail wheel interface, the contact area increase and contact pressure change as tracks worn off. The tests were conducted without any significant amount of traction, but micro slip was still observed due to contact deformation. Moreover, variation of contact pressure was observed due to contact patch elongation and diameter reduction. Rolling contact fatigue, adhesive and sliding wear were observed on the curved contact interface. The development of different wear regimes and material removal phenomena were analysed using microscopic images in order to broaden the understanding of the wear mechanisms occurring in the rail-wheel contact.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work investigates the effects of contact pressure and geometry in rolling-contact wear tests by using discs with different radii of curvature to simulate the varying contact conditions that may be typically found in the field. The tests were conducted without any significant amount of traction, but micro slip was still observed due to contact deformation. Moreover, variation of contact pressure was observed due to contact patch elongation and diameter reduction. Rolling contact fatigue, adhesive and sliding wear were observed on the curved contact interface. The development of different wear regimes and material removal phenomena were analyzed using microscopic images in order to broaden the understanding of the wear mechanisms occurring in the rail-wheel contact.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE To estimate refractive indices used by the Lenstar biometer to translate measured optical path lengths into geometrical path lengths within the eye. METHODS Axial lengths of model eyes were determined using the IOLMaster and Lenstar biometers; comparing those lengths gave an overall eye refractive index estimate for the Lenstar. Using the Lenstar Graphical User Interface, we noticed that boundaries between media could be manipulated and opposite changes in optical path lengths on either side of the boundary could be introduced. Those ratios were combined with the overall eye refractive index to estimate separate refractive indices. Furthermore, Haag-Streit provided us with a template to obtain 'air thicknesses' to compare with geometrical distances. RESULTS The axial length estimates obtained using the IOLMaster and the Lenstar agreed to within 0.01 mm. Estimates of group refractive indices used in the Lenstar were 1.340, 1.341, 1.415, and 1.354 for cornea, aqueous, lens, and overall eye, respectively. Those refractive indices did not match those of schematic eyes, but were close in the cases of aqueous and lens. Linear equations relating air thicknesses to geometrical thicknesses were consistent with our findings. CONCLUSION The Lenstar uses different refractive indices for different ocular media. Some of the refractive indices, such as that for the cornea, are not physiological; therefore, it is likely that the calibrations in the instrument correspond to instrument-specific corrections and are not the real optical path lengths.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Creatinine was proposed to be used as a population normalising factor in sewage epidemiology but its stability in the sewer system has not been assessed. This study thus aimed to evaluate the fate of creatinine under different sewer conditions using laboratory sewer reactors. The results showed that while creatinine was stable in wastewater only, it degraded quickly in reactors with the presence of sewer biofilms. The degradation followed first order kinetics with significantly higher rate in rising main condition than in gravity sewer condition. Additionally, daily loads of creatinine were determined in wastewater samples collected on Census day from 10 wastewater treatment plants around Australia. The measured loads of creatinine from those samples were much lower than expected and did not correlate with the populations across the sampled treatment plants. The results suggested that creatinine may not be a suitable biomarker for population normalisation purpose in sewage epidemiology, especially in sewer catchment with high percentage of rising mains.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Paediatric onset inflammatory bowel disease (IBD) may cause alterations in energy requirements and invalidate the use of standard prediction equations. Our aim was to evaluate four commonly used prediction equations for resting energy expenditure (REE) in children with IBD. Methods: Sixty-three children had repeated measurements of REE as part of a longitudinal research study yielding a total of 243 measurements. These were compared with predicted REE from Schofield, Oxford, FAO/WHO/UNU, and Harris-Benedict equations using the Bland-Altman method. Results: Mean (±SD) age of the patients was 14.2 (2.4) years. Mean measured REE was 1566 (336) kcal per day compared with 1491 (236), 1441 (255), 1481 (232), and 1435 (212) kcal per day calculated from Schofield, Oxford, FAO/WHO/UNU, and Harris-Benedict, respectively. While the Schofield equation demonstrated the least difference between measured and predicted REE, it, along with the other equations tested, did not perform uniformly across all subjects, indicating greater errors at either end of the spectrum of energy expenditure. Smaller differences were found for all prediction equations for Crohn's disease compared with ulcerative colitis. Conclusions: Of the commonly used equations, the equation of Schofield should be used in pediatric patients with IBD when measured values are not able to be obtained. (Inflamm Bowel Dis 2010;) Copyright © 2010 Crohn's & Colitis Foundation of America, Inc.