124 resultados para To-hip-ratio


Relevância:

80.00% 80.00%

Publicador:

Resumo:

- Purpose Communication of risk management practices are a critical component of good corporate governance. Research to date has been of little benefit in informing regulators internationally. This paper seeks to contribute to the literature by investigating how listed Australian companies in a setting where disclosures are explicitly required by the ASX corporate governance framework, disclose risk management (RM) information in the corporate governance statements within annual reports. - Design/methodology/approach To address our study’s research questions and related hypotheses, we examine the top 300 ASX-listed companies by market capitalisation at 30 June 2010. For these firms, we identify, code and categorise RM disclosures made in the annual reports according to the disclosure categories specified in Australian Stock Exchange Corporate Governance Principles and Recommendations (ASX CGPR). The derived data is then examined using a comprehensive approach comprising thematic content analysis and regression analysis. - Findings The results indicate widespread divergence in disclosure practices and low conformance with the Principle 7 of the ASX CGPR. This result suggests that companies are not disclosing all ‘material business risks’ possibly due to ignorance at the board level, or due to the intentional withholding of sensitive information from financial statement users. The findings also show mixed results across the factors expected to influence disclosure behaviour. Notably, the presence of a risk committee (RC) (in particular, a standalone RC) and technology committee (TC) are found to be associated with improved levels of disclosure. we do not find evidence that company risk measures (as proxied by equity beta and the market-to-book ratio) are significantly associated with greater levels of RM disclosure. Also, contrary to common findings in the disclosure literature, factors such as board independence and expertise, audit committee independence, and the usage of a Big-4 auditor do not seem to impact the level of RM disclosure in the Australian context. - Research limitation/implications The study is limited by the sample and study period selection as the RM disclosures of only the largest (top 300) ASX firms are examined for the fiscal year 2010. Thus, the finding may not be generalisable to smaller firms, or earlier/later years. Also, the findings may have limited applicability in other jurisdictions with different regulatory environments. - Practical implications The study’s findings suggest that insufficient attention has been applied to RM disclosures by listed companies in Australia. These results suggest that the RM disclosures practices observed in the Australian setting may not be meeting the objectives of regulators and the needs of stakeholders. - Originality/value Despite the importance of risk management communication, it is unclear whether disclosures in annual financial reports achieve this communication. The Australian setting provides an ideal environment to examine the nature and extent of risk management communication as the Australian Securities Exchange (ASX) has recommended risk management disclosures follow Principle 7 of its principle-based governance rules since 2007.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE This study determined if deficits in corneal nerve fiber length (CNFL) assessed using corneal confocal microscopy (CCM) can predict future onset of diabetic peripheral neuropathy (DPN). RESEARCH DESIGN AND METHODS CNFL and a range of other baseline measures were compared between 90 nonneuropathic patients with type 1 diabetes who did or did not develop DPN after 4 years. The receiver operator characteristic (ROC) curve was used to determine the capability of single and combined measures of neuropathy to predict DPN. RESULTS DPN developed in 16 participants (18%) after 4 years. Factors predictive of 4-year incident DPN were lower CNFL (P = 0.041); longer duration of diabetes (P = 0.002); higher triglycerides (P = 0.023); retinopathy (higher on the Early Treatment of Diabetic Retinopathy Study scale) (P = 0.008); nephropathy (higher albumin-to-creatinine ratio) (P = 0.001); higher neuropathy disability score (P = 0.037); lower cold sensation (P = 0.001) and cold pain (P = 0.027) thresholds; higher warm sensation (P = 0.008), warm pain (P = 0.024), and vibration (P = 0.003) thresholds; impaired monofilament response (P = 0.003); and slower peroneal (P = 0.013) and sural (P = 0.002) nerve conduction velocity. CCM could predict the 4-year incident DPN with 63% sensitivity and 74% specificity for a CNFL threshold cutoff of 14.1 mm/mm2 (area under ROC curve = 0.66, P = 0.041). Combining neuropathy measures did not improve predictive capability. CONCLUSIONS DPN can be predicted by various demographic, metabolic, and conventional neuropathy measures. The ability of CCM to predict DPN broadens the already impressive diagnostic capabilities of this novel ophthalmic marker.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We use Bayesian model selection techniques to test extensions of the standard flat LambdaCDM paradigm. Dark-energy and curvature scenarios, and primordial perturbation models are considered. To that end, we calculate the Bayesian evidence in favour of each model using Population Monte Carlo (PMC), a new adaptive sampling technique which was recently applied in a cosmological context. The Bayesian evidence is immediately available from the PMC sample used for parameter estimation without further computational effort, and it comes with an associated error evaluation. Besides, it provides an unbiased estimator of the evidence after any fixed number of iterations and it is naturally parallelizable, in contrast with MCMC and nested sampling methods. By comparison with analytical predictions for simulated data, we show that our results obtained with PMC are reliable and robust. The variability in the evidence evaluation and the stability for various cases are estimated both from simulations and from data. For the cases we consider, the log-evidence is calculated with a precision of better than 0.08. Using a combined set of recent CMB, SNIa and BAO data, we find inconclusive evidence between flat LambdaCDM and simple dark-energy models. A curved Universe is moderately to strongly disfavoured with respect to a flat cosmology. Using physically well-motivated priors within the slow-roll approximation of inflation, we find a weak preference for a running spectral index. A Harrison-Zel'dovich spectrum is weakly disfavoured. With the current data, tensor modes are not detected; the large prior volume on the tensor-to-scalar ratio r results in moderate evidence in favour of r=0.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Three-dimensional (3D) hierarchical nanoscale architectures comprised of building blocks, with specifically engineered morphologies, are expected to play important roles in the fabrication of 'next generation' microelectronic and optoelectronic devices due to their high surface-to-volume ratio as well as opto-electronic properties. Herein, a series of well-defined 3D hierarchical rutile TiO2 architectures (HRT) were successfully prepared using a facile hydrothermal method without any surfactant or template, simply by changing the concentration of hydrochloric acid used in the synthesis. The production of these materials provides, to the best of our knowledge, the first identified example of a ledgewise growth mechanism in a rutile TiO2 structure. Also for the first time, a Dye-sensitized Solar Cell (DSC) combining a HRT is reported in conjunction with a high-extinction-coefficient metal-free organic sensitizer (D149), achieving a conversion efficiency of 5.5%, which is superior to ones employing P25 (4.5%), comparable to state-of-the-art commercial transparent titania anatase paste (5.8%). Further to this, an overall conversion efficiency 8.6% was achieved when HRT was used as the light scattering layer, a considerable improvement over the commercial transparent/reflector titania anatase paste (7.6%), a significantly smaller gap in performance than has been seen previously.