271 resultados para Royal Hospital for Seamen at Greenwich
Resumo:
Aim. To develop and evaluate the implementation of a communication board for paramedics to use with patients as an augmentative or alternative communication tool to address communication needs of patients in the pre-hospital setting. Method. A double-sided A4-size communication board was designed specifically for use in the pre-hospital setting by the Queensland Ambulance Service and Disability and Community Care Services. One side of the board contains expressive messages that could be used by both the patient and paramedic. The other side contains messages to support patients’ understanding and interaction tips for the paramedic. The communication board was made available in every ambulance and patient transport vehicle in the Brisbane Region. Results. A total of 878 paramedics completed a survey that gauged which patient groups they might use the communication board with. The two most common groups were patients from culturally and linguistically diverse backgrounds and children. Staff reported feeling confident in using the board, and 72% of interviewed paramedics agreed that the communication board was useful for aiding communication with patients. Feedback from paramedics suggests that the board is simple to use, reduces patient frustration and improves communication. Conclusion. These results suggest that a communication board can be applied in the pre-hospital setting to support communication success with patients. What is known about the topic? It is imperative that communication between patient and paramedic is clear and effective. Research has shown that communication boards have been effective with people with temporary or permanent communication difficulties. What does this paper add? This is the first paper outlining the development and use of a communication board by paramedics in the pre-hospital setting in Australia. The paper details the design of the communication board for the unique pre-hospital environment. The paper provides some preliminary data on the use of the communication board with certain patient groups and its effectiveness as an alternative communication tool. What are the implications for practitioners? The findings support the use of the tool as a viable option in supporting the communication between paramedics and a range of patients. It is not suggested that this communication board will meet the complete communication needs of any individual in this environment, but it is hoped that the board’s presence within the Queensland Ambulance Service may result in paramedics introducing the board on occasions where communication with a patient is challenging.
Resumo:
Background Carbohydrate-rich fluids are used to improve postoperative recovery but the effectiveness of the product for reducing length of hospital stay is uncertain. Objective To assess the effectiveness of preoperative loading with carbohydrates on postoperative outcomes. Participants Forty six patients booked for elective colorectal surgery. Methods Participants were allocated to a Carbohydrate-rich fluid group or Usual Care group during their pre-admission clinic visit. The primary outcome was ‘Time to readiness for discharge’. Results Patients in the control group spent on average 4.3 days (95% confidence interval 3.2 to 5.7) and the Carbohydrate-rich fluid group spent 4.1 days (95% confidence interval 3.2 to 5.4) until the primary outcome was met (p=0.824). Conclusion The safety of preoperative high carbohydrate fluids is supported but we were unable to confirm or refute the benefit of CHO for shorter hospital stay following elective colorectal surgery.
Resumo:
Purpose: The precise shape of the three-dimensional dose distributions created by intensity-modulated radiotherapy means that the verification of patient position and setup is crucial to the outcome of the treatment. In this paper, we investigate and compare the use of two different image calibration procedures that allow extraction of patient anatomy from measured electronic portal images of intensity-modulated treatment beams. Methods and Materials: Electronic portal images of the intensity-modulated treatment beam delivered using the dynamic multileaf collimator technique were acquired. The images were formed by measuring a series of frames or segments throughout the delivery of the beams. The frames were then summed to produce an integrated portal image of the delivered beam. Two different methods for calibrating the integrated image were investigated with the aim of removing the intensity modulations of the beam. The first involved a simple point-by-point division of the integrated image by a single calibration image of the intensity-modulated beam delivered to a homogeneous polymethyl methacrylate (PMMA) phantom. The second calibration method is known as the quadratic calibration method and required a series of calibration images of the intensity-modulated beam delivered to different thicknesses of homogeneous PMMA blocks. Measurements were made using two different detector systems: a Varian amorphous silicon flat-panel imager and a Theraview camera-based system. The methods were tested first using a contrast phantom before images were acquired of intensity-modulated radiotherapy treatment delivered to the prostate and pelvic nodes of cancer patients at the Royal Marsden Hospital. Results: The results indicate that the calibration methods can be used to remove the intensity modulations of the beam, making it possible to see the outlines of bony anatomy that could be used for patient position verification. This was shown for both posterior and lateral delivered fields. Conclusions: Very little difference between the two calibration methods was observed, so the simpler division method, requiring only the single extra calibration measurement and much simpler computation, was the favored method. This new method could provide a complementary tool to existing position verification methods, and it has the advantage that it is completely passive, requiring no further dose to the patient and using only the treatment fields.
Resumo:
Introduction: The accurate identification of tissue electron densities is of great importance for Monte Carlo (MC) dose calculations. When converting patient CT data into a voxelised format suitable for MC simulations, however, it is common to simplify the assignment of electron densities so that the complex tissues existing in the human body are categorized into a few basic types. This study examines the effects that the assignment of tissue types and the calculation of densities can have on the results of MC simulations, for the particular case of a Siemen’s Sensation 4 CT scanner located in a radiotherapy centre where QA measurements are routinely made using 11 tissue types (plus air). Methods: DOSXYZnrc phantoms are generated from CT data, using the CTCREATE user code, with the relationship between Hounsfield units (HU) and density determined via linear interpolation between a series of specified points on the ‘CT-density ramp’ (see Figure 1(a)). Tissue types are assigned according to HU ranges. Each voxel in the DOSXYZnrc phantom therefore has an electron density (electrons/cm3) defined by the product of the mass density (from the HU conversion) and the intrinsic electron density (electrons /gram) (from the material assignment), in that voxel. In this study, we consider the problems of density conversion and material identification separately: the CT-density ramp is simplified by decreasing the number of points which define it from 12 down to 8, 3 and 2; and the material-type-assignment is varied by defining the materials which comprise our test phantom (a Supertech head) as two tissues and bone, two plastics and bone, water only and (as an extreme case) lead only. The effect of these parameters on radiological thickness maps derived from simulated portal images is investigated. Results & Discussion: Increasing the degree of simplification of the CT-density ramp results in an increasing effect on the resulting radiological thickness calculated for the Supertech head phantom. For instance, defining the CT-density ramp using 8 points, instead of 12, results in a maximum radiological thickness change of 0.2 cm, whereas defining the CT-density ramp using only 2 points results in a maximum radiological thickness change of 11.2 cm. Changing the definition of the materials comprising the phantom between water and plastic and tissue results in millimetre-scale changes to the resulting radiological thickness. When the entire phantom is defined as lead, this alteration changes the calculated radiological thickness by a maximum of 9.7 cm. Evidently, the simplification of the CT-density ramp has a greater effect on the resulting radiological thickness map than does the alteration of the assignment of tissue types. Conclusions: It is possible to alter the definitions of the tissue types comprising the phantom (or patient) without substantially altering the results of simulated portal images. However, these images are very sensitive to the accurate identification of the HU-density relationship. When converting data from a patient’s CT into a MC simulation phantom, therefore, all possible care should be taken to accurately reproduce the conversion between HU and mass density, for the specific CT scanner used. Acknowledgements: This work is funded by the NHMRC, through a project grant, and supported by the Queensland University of Technology (QUT) and the Royal Brisbane and Women's Hospital (RBWH), Brisbane, Australia. The authors are grateful to the staff of the RBWH, especially Darren Cassidy, for assistance in obtaining the phantom CT data used in this study. The authors also wish to thank Cathy Hargrave, of QUT, for assistance in formatting the CT data, using the Pinnacle TPS. Computational resources and services used in this work were provided by the HPC and Research Support Group, QUT, Brisbane, Australia.
Resumo:
Introduction: The use of amorphous-silicon electronic portal imaging devices (a-Si EPIDs) for dosimetry is complicated by the effects of scattered radiation. In photon radiotherapy, primary signal at the detector can be accompanied by photons scattered from linear accelerator components, detector materials, intervening air, treatment room surfaces (floor, walls, etc) and from the patient/phantom being irradiated. Consequently, EPID measurements which presume to take scatter into account are highly sensitive to the identification of these contributions. One example of this susceptibility is the process of calibrating an EPID for use as a gauge of (radiological) thickness, where specific allowance must be made for the effect of phantom-scatter on the intensity of radiation measured through different thicknesses of phantom. This is usually done via a theoretical calculation which assumes that phantom scatter is linearly related to thickness and field-size. We have, however, undertaken a more detailed study of the scattering effects of fields of different dimensions when applied to phantoms of various thicknesses in order to derive scattered-primary ratios (SPRs) directly from simulation results. This allows us to make a more-accurate calibration of the EPID, and to qualify the appositeness of the theoretical SPR calculations. Methods: This study uses a full MC model of the entire linac-phantom-detector system simulated using EGSnrc/BEAMnrc codes. The Elekta linac and EPID are modelled according to specifications from the manufacturer and the intervening phantoms are modelled as rectilinear blocks of water or plastic, with their densities set to a range of physically realistic and unrealistic values. Transmissions through these various phantoms are calculated using the dose detected in the model EPID and used in an evaluation of the field-size-dependence of SPR, in different media, applying a method suggested for experimental systems by Swindell and Evans [1]. These results are compared firstly with SPRs calculated using the theoretical, linear relationship between SPR and irradiated volume, and secondly with SPRs evaluated from our own experimental data. An alternate evaluation of the SPR in each simulated system is also made by modifying the BEAMnrc user code READPHSP, to identify and count those particles in a given plane of the system that have undergone a scattering event. In addition to these simulations, which are designed to closely replicate the experimental setup, we also used MC models to examine the effects of varying the setup in experimentally challenging ways (changing the size of the air gap between the phantom and the EPID, changing the longitudinal position of the EPID itself). Experimental measurements used in this study were made using an Elekta Precise linear accelerator, operating at 6MV, with an Elekta iView GT a-Si EPID. Results and Discussion: 1. Comparison with theory: With the Elekta iView EPID fixed at 160 cm from the photon source, the phantoms, when positioned isocentrically, are located 41 to 55 cm from the surface of the panel. At this geometry, a close but imperfect agreement (differing by up to 5%) can be identified between the results of the simulations and the theoretical calculations. However, this agreement can be totally disrupted by shifting the phantom out of the isocentric position. Evidently, the allowance made for source-phantom-detector geometry by the theoretical expression for SPR is inadequate to describe the effect that phantom proximity can have on measurements made using an (infamously low-energy sensitive) a-Si EPID. 2. Comparison with experiment: For various square field sizes and across the range of phantom thicknesses, there is good agreement between simulation data and experimental measurements of the transmissions and the derived values of the primary intensities. However, the values of SPR obtained through these simulations and measurements seem to be much more sensitive to slight differences between the simulated and real systems, leading to difficulties in producing a simulated system which adequately replicates the experimental data. (For instance, small changes to simulated phantom density make large differences to resulting SPR.) 3. Comparison with direct calculation: By developing a method for directly counting the number scattered particles reaching the detector after passing through the various isocentric phantom thicknesses, we show that the experimental method discussed above is providing a good measure of the actual degree of scattering produced by the phantom. This calculation also permits the analysis of the scattering sources/sinks within the linac and EPID, as well as the phantom and intervening air. Conclusions: This work challenges the assumption that scatter to and within an EPID can be accounted for using a simple, linear model. Simulations discussed here are intended to contribute to a fuller understanding of the contribution of scattered radiation to the EPID images that are used in dosimetry calculations. Acknowledgements: This work is funded by the NHMRC, through a project grant, and supported by the Queensland University of Technology (QUT) and the Royal Brisbane and Women's Hospital, Brisbane, Australia. The authors are also grateful to Elekta for the provision of manufacturing specifications which permitted the detailed simulation of their linear accelerators and amorphous-silicon electronic portal imaging devices. Computational resources and services used in this work were provided by the HPC and Research Support Group, QUT, Brisbane, Australia.
Resumo:
The purpose of this study was to describe Japanese hospital nurses’ perceptions of the nursing practice environment and examine its association with nurse-reported ability to provide quality nursing care, quality of patient care and ward morale. A cross-sectional survey design was used including 223 nurses working in 12 acute inpatient wards in a large Japanese teaching hospital. Nurses rated their work environment favorably overall using the Japanese version of the Practice Environment Scale of the Nursing Work Index. Subscale scores indicated high perceptions of physician relations and quality of nursing management, but lower scores for staffing and resources. Ward nurse managers generally rated the practice environment more positively than staff nurses except for staffing and resources. Regression analyses found the practice environment was a significant predictor of quality of patient care and ward morale, whereas perceived ability to provide quality nursing care was most strongly associated with years of clinical experience. These findings support interventions to improve the nursing practice environment, particularly staffing and resource adequacy, to enhance quality of care and ward morale in Japan.
Resumo:
Background: Previous attempts at costing infection control programmes have tended to focus on accounting costs rather than economic costs. For studies using economic costs, estimates tend to be quite crude and probably underestimate the true cost. One of the largest costs of any intervention is staff time, but this cost is difficult to quantify and has been largely ignored in previous attempts. Aim: To design and evaluate the costs of hospital-based infection control interventions or programmes. This article also discusses several issues to consider when costing interventions, and suggests strategies for overcoming these issues. Methods: Previous literature and techniques in both health economics and psychology are reviewed and synthesized. Findings: This article provides a set of generic, transferable costing guidelines. Key principles such as definition of study scope and focus on large costs, as well as pitfalls (e.g. overconfidence and uncertainty), are discussed. Conclusion: These new guidelines can be used by hospital staff and other researchers to cost their infection control programmes and interventions more accurately.
Resumo:
BACKGROUND: Public hospital EDs in Australia have become increasingly congested because of increasing demand and access block. Six per cent of ED patients attend private hospital EDs whereas 45% of the population hold private health insurance. OBJECTIVES: This study describes the patients attending a small selection of four private hospital EDs in Queensland and Victoria, and tests the feasibility of a private ED database. METHODS: De-identified routinely collected patient data were provided by the four participating private hospital and amalgamated into a single data set. RESULT: The mean age of private ED patients was 52 years. Males outnumbered females in all age groups except > 80 years. Attendance was higher on weekends and Mondays, and between 08.00 and 20.00 h. There were 6.6% of the patients triaged as categories 1 and 2, and 60% were categories 4 or 5. There were 36.4% that required hospital admission. Also, 96% of the patients had some kind of insurance. Furthermore, 72% were self-referred and 12% were referred by private medical practitioners. Approximately 25% arrived by ambulance. There were 69% that completed their ED treatment within 4 h. CONCLUSION: This study is the first public description of patients attending private EDs in Australia. Private EDs have a significant role to play in acute medical care and in providing access to private hospitals which could alleviate pressure on public EDs. This study demonstrates the need for consolidated data based on a consistent data set and data dictionary to enable system-wide analysis, benchmarking and evaluation
Resumo:
Mortality and cost outcomes of elderly intensive care unit (ICU) trauma patients were characterised in a retrospective cohort study from an Australian tertiary ICU. Trauma patients admitted between January 2000 and December 2005 were grouped into three major age categories: aged ≥65 years admitted into ICU (n=272); aged ≥65 years admitted into general ward (n=610) and aged <65 years admitted into ICU (n=1617). Hospital mortality predictors were characterised as odds ratios (OR) using logistic regression. The impact of predictor variables on (log) total hospital-stay costs was determined using least squares regression. An alternate treatment-effects regression model estimated the mortality cost-effect as an endogenous variable. Mortality predictors (P ≤0.0001, comparator: ICU ≥65 years, ventilated) were: ICU <65 not-ventilated (OR 0.014); ICU <65 ventilated (OR 0.090); ICU age ≥65 not-ventilated (OR 0.061) and ward ≥65 (OR 0.086); increasing injury severity score and increased Charlson comorbidity index of 1 and 2, compared with zero (OR 2.21 [1.40 to 3.48] and OR 2.57 [1.45 to 4.55]). The raw mean daily ICU and hospital costs in A$ 2005 (US$) for age <65 and ≥65 to ICU, and ≥65 to the ward were; for year 2000: ICU, $2717 (1462) and $2777 (1494); hospital, $1837 (988) and $1590 (855); ward $933 (502); for year 2005: ICU, $3202 (2393) and $3086 (2307); hospital, $1938 (1449) and $1914 (1431); ward $1180 (882). Cost increments were predicted by age ≥65 and ICU admission, increasing injury severity score, mechanical ventilation, Charlson comorbidity index increments and hospital survival. Mortalitycost-effect was estimated at -63% by least squares regression and -82% by treatment-effects regression model. Patient demographic factors, injury severity and its consequences predict both cost and survival in trauma. The cost mortality effect was biased upwards by conventional least squares regression estimation.
Resumo:
Despite the increasing number of immigrants, there is a limited body of literature describing the use of hospital emergency department (ED) care by immigrants in Australia. This study aims to describe how immigrants from refugee source countries (IRSC) utilise ED care, compared to immigrants from the main English speaking countries (MESC), immigrants from other countries (IOC) and the local population in Queensland. A retrospective analysis of a Queensland state-wide hospital ED dataset (ED Information System) from 1-1-2008 to 31-12-2010 was conducted. Our study showed that immigrants are not a homogenous group. We found that immigrants from IRSC are more likely to use interpreters (8.9%) in the ED compared to IOC. Furthermore, IRSC have a higher rate of ambulance use (odds ratio 1.2, 95% confidence interval (CI) 1.2–1.3), are less likely to be admitted to the hospital from the ED (odds ratio 0.7 (95% CI 0.7–0.8), and have a longer length of stay (LOS; mean differences 33.0, 95% CI 28.8–37.2), in minutes, in the ED compared to the Australian born population. Our findings highlight the need to develop policies and educational interventions to ensure the equitable use of health services among vulnerable immigrant populations.
Resumo:
Background Falls are one of the most frequently occurring adverse events that impact upon the recovery of older hospital inpatients. Falls can threaten both immediate and longer-term health and independence. There is need to identify cost-effective means for preventing falls in hospitals. Hospital-based falls prevention interventions tested in randomized trials have not yet been subjected to economic evaluation. Methods Incremental cost-effectiveness analysis was undertaken from the health service provider perspective, over the period of hospitalization (time horizon) using the Australian Dollar (A$) at 2008 values. Analyses were based on data from a randomized trial among n = 1,206 acute and rehabilitation inpatients. Decision tree modeling with three-way sensitivity analyses were conducted using burden of disease estimates developed from trial data and previous research. The intervention was a multimedia patient education program provided with trained health professional follow-up shown to reduce falls among cognitively intact hospital patients. Results The short-term cost to a health service of one cognitively intact patient being a faller could be as high as A$14,591 (2008). The education program cost A$526 (2008) to prevent one cognitively intact patient becoming a faller and A$294 (2008) to prevent one fall based on primary trial data. These estimates were unstable due to high variability in the hospital costs accrued by individual patients involved in the trial. There was a 52% probability the complete program was both more effective and less costly (from the health service perspective) than providing usual care alone. Decision tree modeling sensitivity analyses identified that when provided in real life contexts, the program would be both more effective in preventing falls among cognitively intact inpatients and cost saving where the proportion of these patients who would otherwise fall under usual care conditions is at least 4.0%. Conclusions This economic evaluation was designed to assist health care providers decide in what circumstances this intervention should be provided. If the proportion of cognitively intact patients falling on a ward under usual care conditions is 4% or greater, then provision of the complete program in addition to usual care will likely both prevent falls and reduce costs for a health service.
Resumo:
This study is the first to employ an epidemiological framework to evaluate the ‘fit-for-purpose’ of ICD-10-AM external cause of injury codes, ambulance and hospital clinical documentation for injury surveillance. Importantly, this thesis develops an evidence-based platform to guide future improvements in routine data collections used to inform the design of effective injury prevention strategies. Quantification of the impact of ambulance clinical records on the overall information quality of Queensland hospital morbidity data collections for injury causal information is a unique and notable contribution of this study.