220 resultados para Radiation sources.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Generating nano-sized materials of a controlled size and chemical composition is essential for the manufacturing of materials with enhanced properties on an industrial scale, as well as for research purposes, such as toxicological studies. Among the generation methods for airborne nanoparticles (also known as aerosolisation methods), liquid-phase techniques have been widely applied due to the simplicity of their use and their high particle production rate. The use of a collison nebulizer is one such technique, in which the atomisation takes place as a result of the liquid being sucked into the air stream and injected toward the inner walls of the nebulizer reservoir via nozzles, before the solution is dispersed. Despite the above-mentioned benefits, this method also falls victim to various sources of impurities (Knight and Petrucci 2003; W. LaFranchi, Knight et al. 2003). Since these impurities can affect the characterization of the generated nanoparticles, it is crucial to understand and minimize their effect.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method for prediction of the radiation pattern of N strongly coupled antennas with mismatched sources is presented. The method facilitates fast and accurate design of compact arrays. The prediction is based on the measured N-port S parameters of the coupled antennas and the N active element patterns measured in a 50 ω environment. By introducing equivalent power sources, the radiation pattern with excitation by sources with arbitrary impedances and various decoupling and matching networks (DMN) can be accurately predicted without the need for additional measurements. Two experiments were carried out for verification: pattern prediction for parasitic antennas with different loads and for antennas with DMN. The difference between measured and predicted patterns was within 1 to 2 dB.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel method was developed for studying the genetic relatedness of Pseudomonas aeruginosa isolates from clinical and environmental sources. This bacterium is ubiquitous in the natural environment and is an important pathogen known to infect Cystic Fibrosis (CF) patients. The transmission route of strains has not yet been defined; current theories include acquisition from an environmental source or through patient-to-patient spread. A highly discriminatory, bioinformatics based, DNA typing method was developed to investigate the relatedness of clinical and environmental isolates. This study found a similarity between the environmental and several CF clonal strains and also highlighted occurrence of environmental P. aeruginosa strains in CF infections.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Prior to 2009, one of the problems faced by radiation therapists who supervised and assessed students on placement in Australian clinical centres, was that each of the six Australian universities where Radiation Therapy (RT) programmes were conducted used different clinical assessment and reporting criteria. This paper describes the development of a unified national clinical assessment and reporting form that was implemented nationally by all six universities in 2009. Methods: A four phase methodology was used to develop the new assessment form and user guide. Phase 1 included university consensus around domains of student practice and assessment, and alignment with national competency standards; Phase 2 was a national consensus workshop attended by radiation therapists involved in student supervision and assessment; Phase 3 was an action research re-iterative Delphi technique involving two rounds of a mail-out to gain further expert consensus; and stage 4 was national piloting of the developed assessment form. Results: The new assessment form includes five main domains of practice and 19 sub-domain criteria which students are assessed against during placement. Feedback from the pilot centre participants was positive, with the new form being assessed to be comprehensive and complemented by the accompanying user guide. Conclusion: The new assessment form has improved both the formative and summative assessment of students on placement, as well as enhancing the quality of feedback to students and the universities. The new national form has high acceptance from the Australian universities and has been subject to wide review by the profession.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose The aim of this case study is to describe clinical staff perceptions of implementing a person-centred model of nursing in an outpatient radiotherapy treatment department, using a Primary Nursing/Collaborative Practice framework. The questions are: 1) what are the nursing and radiotherapy staff perspectives of the changed model of care, 2) what factors impacted on aspects of the evolving model?, and 3) how was interdisciplinary collaboration influenced by the new model? Methods An instrumental case study addressed the multiple perspectives of several radiotherapy health professionals, within a qualitative approach, to assess the new model of nursing care. Interview data were obtained from thirteen clinical staff over a six month period approximately one year after the model was implemented. Results The new model supports nurses to work more closely with the individual patient, with some perceived positive patient outcomes. Nurses reported increased satisfaction with their work, more autonomy and responsibility, and improved working relationships with medical staff. They also became more aware of the holistic approach to support positive patient outcomes. However, this study acknowledged that education was required for nurses to provide holistic care, especially in the context of complex interdisciplinary relationships. Conclusions A person-centred nursing approach in radiotherapy represents a radical change to the functional approach, providing some benefits for patients. However, the challenges of providing holistic care in the context of complex interdisciplinary relationships are evident, and this study acknowledges the importance of a team approach to addressing changes in practice in the future.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A design for a cascaded multilevel DC-DC converter is proposed. The applications of a multilevel converter and the design issues involved in changing from a single converter to multiple converters are discussed. Implementation of the multilevel system using multiple Cuk converters is suggested and explanations of design decisions are given. The merits of the proposed design are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose Intensity modulated radiotherapy (IMRT) treatments require more beam-on time and produce more linac head leakage to deliver similar doses to conventional, unmodulated, radiotherapy treatments. It is necessary to take this increased leakage into account when evaluating the results of radiation surveys around bunkers that are, or will be, used for IMRT. The recommended procedure of 15 applying a monitor-unit based workload correction factor to secondary barrier survey measurements, to account for this increased leakage when evaluating radiation survey measurements around IMRT bunkers, can lead to potentially-costly over estimation of the required barrier thickness. This study aims to provide initial guidance on the validity of reducing the value of the correction factor when applied to different radiation barriers (primary barriers, doors, maze walls and other walls) by 20 evaluating three different bunker designs. Methods Radiation survey measurements of primary, scattered and leakage radiation were obtained at each of five survey points around each of three different radiotherapy bunkers and the contribution of leakage to the total measured radiation dose at each point was evaluated. Measurements at each survey point were made with the linac gantry set to 12 equidistant positions from 0 to 330o, to 25 assess the effects of radiation beam direction on the results. Results For all three bunker designs, less than 0.5% of dose measured at and alongside the primary barriers, less than 25% of the dose measured outside the bunker doors and up to 100% of the dose measured outside other secondary barriers was found to be caused by linac head leakage. Conclusions Results of this study suggest that IMRT workload corrections are unnecessary, for 30 survey measurements made at and alongside primary barriers. Use of reduced IMRT workload correction factors is recommended when evaluating survey measurements around a bunker door, provided that a subset of the measurements used in this study are repeated for the bunker in question. Reduction of the correction factor for other secondary barrier survey measurements is not recommended unless the contribution from leakage is separetely evaluated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research developed and scientifically validated a new ultrasound transmission computed tomography system with the aim of quantitative assessment of a polymer gel dosimeter including dose response verification of ultrasonic parameters of attenuation, velocity and broadband ultrasound attenuation (BUA). This work was the first to investigate and report ultrasound frequency dependent attenuation in a gel dosimeter, demonstrating a dose dependence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study identified the key self-regulated learning (SRL) strategies and their sources for nine school-aged adolescent males aged 15 to 17 years. The Self-Regulated Learning Interview Schedule (SRLIS) was used along with semi-structured interviews with the participants and their parents to elicit information on SRL strategies and contexts for the formation of self-regulatory habits. Early habit-forming experiences of the family home in relation to homework and study routines were found to form an important base for effective SRL. Teachers were identified as the most common source of SRL strategies with important formative experiences occurring during the first two years of high school.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Custom designed for display on the Cube Installation situated in the new Science and Engineering Centre (SEC) at QUT, the ECOS project is a playful interface that uses real-time weather data to simulate how a five-star energy building operates in climates all over the world. In collaboration with the SEC building managers, the ECOS Project incorporates energy consumption and generation data of the building into an interactive simulation, which is both engaging to users and highly informative, and which invites play and reflection on the roles of green buildings. ECOS focuses on the principle that humans can have both a positive and negative impact on ecosystems with both local and global consequence. The ECOS project draws on the practice of Eco-Visualisation, a term used to encapsulate the important merging of environmental data visualization with the philosophy of sustainability. Holmes (2007) uses the term Eco-Visualisation (EV) to refer to data visualisations that ‘display the real time consumption statistics of key environmental resources for the goal of promoting ecological literacy’. EVs are commonly artifacts of interaction design, information design, interface design and industrial design, but are informed by various intellectual disciplines that have shared interests in sustainability. As a result of surveying a number of projects, Pierce, Odom and Blevis (2008) outline strategies for designing and evaluating effective EVs, including ‘connecting behavior to material impacts of consumption, encouraging playful engagement and exploration with energy, raising public awareness and facilitating discussion, and stimulating critical reflection.’ Consequently, Froehlich (2010) and his colleagues also use the term ‘Eco-feedback technology’ to describe the same field. ‘Green IT’ is another variation which Tomlinson (2010) describes as a ‘field at the juncture of two trends… the growing concern over environmental issues’ and ‘the use of digital tools and techniques for manipulating information.’ The ECOS Project team is guided by these principles, but more importantly, propose an example for how these principles may be achieved. The ECOS Project presents a simplified interface to the very complex domain of thermodynamic and climate modeling. From a mathematical perspective, the simulation can be divided into two models, which interact and compete for balance – the comfort of ECOS’ virtual denizens and the ecological and environmental health of the virtual world. The comfort model is based on the study of psychometrics, and specifically those relating to human comfort. This provides baseline micro-climatic values for what constitutes a comfortable working environment within the QUT SEC buildings. The difference between the ambient outside temperature (as determined by polling the Google Weather API for live weather data) and the internal thermostat of the building (as set by the user) allows us to estimate the energy required to either heat or cool the building. Once the energy requirements can be ascertained, this is then balanced with the ability of the building to produce enough power from green energy sources (solar, wind and gas) to cover its energy requirements. Calculating the relative amount of energy produced by wind and solar can be done by, in the case of solar for example, considering the size of panel and the amount of solar radiation it is receiving at any given time, which in turn can be estimated based on the temperature and conditions returned by the live weather API. Some of these variables can be altered by the user, allowing them to attempt to optimize the health of the building. The variables that can be changed are the budget allocated to green energy sources such as the Solar Panels, Wind Generator and the Air conditioning to control the internal building temperature. These variables influence the energy input and output variables, modeled on the real energy usage statistics drawn from the SEC data provided by the building managers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Ondansetron is a 5-HT3 receptor antagonist commonly used as an anti-emetic to prevent the nausea and vomiting associated with anti-cancer drugs, cancer radiotherapy, or postoperatively. Recently, the US Food and Drug Administration (FDA) issued a warning for ondansetron due to a potential for prolongation of the QT interval of the electrocardiogram (ECG), a phenomenon that is associated with an increased risk of the potentially fatal arrhythmia torsade de pointes. Areas covered: We undertook a review of the cardiac safety of ondansetron. Our primary sources of information were PubMed (with downloading of full articles), and the internet. Expert opinion: The dose of ondansetron that the FDA has concerns about is 32 mg iv (or several doses that are equivalent to this), which is only used in preventing nausea and vomiting associated with cancer chemotherapy. This suggests that ondansetron may be safe in the lower doses used to prevent the nausea and vomiting in radiation treatment or postoperatively. However, as there is a report that a lower dose of ondansetron prolonged the QT interval in healthy volunteers, this needs to be clarified by the FDA. More research needs to be undertaken of the relationship between QT prolongation and torsades in order that the FDA can produce clear-cut evidence of pro-arrhythmic risk when introducing warnings for this.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The incidences of skin cancers resulting from chronic ultraviolet radiation (UVR) exposure are on the incline both in Australia and globally. Hence, the cellular and molecular pathways associated with UVR-induced photocarcinogenesis urgently need to be elucidated, in order to develop more robust preventative and treatment strategies against skin cancers. In vitro investigations into the effects of UVR (in particular the highly-mutagenic UVB wavelength) have, to date, mainly involved the use of cell culture and animal models. However, these models possess biological disparities to native skin, which to some extent have limited their relevance to the in vivo situation. To address this, we characterised a 3-dimensional, tissue-engineered human skin equivalent (HSE) model (consisting of primary human keratinocytes cultured on a dermal-derived scaffold) as a representation of a more physiologically-relevant platform to study keratinocyte responses to UVB. Significantly, we demonstrate that this model retains several important epidermal properties of native skin. Moreover, UVB-irradiation of the HSE constructs was shown to induce key markers of photodamage in the HSE keratinocytes, including the formation of cyclobutane pyrimidine dimers, the activation of apoptotic pathways, the accumulation of p53 and the secretion of inflammatory cytokines. Importantly, we also demonstrate that the UVB-exposed HSE constructs retain the capacity for epidermal repair and regeneration following photodamage. Together, our results demonstrate the potential of this skin equivalent model as a tool to study various aspects of the acute responses of human keratinocytes to UVB radiation damage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Radiation-induced skin reaction (RISR) is a common side effect that affects the majority of cancer patients receiving radiation treatment. RISR is often characterised by swelling,redness, pigmentation, fibrosis, and ulceration, pain, warmth, burning, and itching of the skin. The aim of this systematic review was to assess the effects of interventions which aim to prevent or manage RISR in people with cancer. Methods We searched the following databases up to November 2012: Cochrane Skin Group Specialised Register, CENTRAL (2012, Issue 11), MEDLINE (from 1946), EMBASE (from 1974), PsycINFO (from 1806), CINAHL (from 1981) and LILACS (from 1982). Randomized controlled trials evaluating interventions for preventing or managing RISR in cancer patients were included. The primary outcomes were development of RISR, and levels of RISR and symptom severity. Secondary outcomes were time taken to develop erythema or dry desquamation; quality of life; time taken to heal, a number of skin reaction and symptom severity measures; cost, participant satisfaction; ease of use and adverse effects. Where appropriate, we pooled results of randomized controlled trials using mean differences (MD) or odd ratios (OR) with 95% confidence intervals (CI). Results Forty-seven studies were included in this review. These evaluated six types of interventions (oral systemic medications; skin care practices; steroidal topical therapies; non-steroidal topical therapies; dressings and other). Findings from two meta-analyses demonstrated significant benefits of oral Wobe-Mugos E for preventing RISR (OR 0.13 (95% CI 0.05 to 0.38)) and limiting the maximal level of RISR (MD −0.92 (95% CI −1.36 to −0.48)). Another meta-analysis reported that wearing deodorant does not influence the development of RISR (OR 0.80 (95% CI 0.47 to 1.37)). Conclusions Despite the high number of trials in this area, there is limited good, comparative research that provides definitive results suggesting the effectiveness of any single intervention for reducing RISR. More research is required to demonstrate the usefulness of a wide range of products that are being used for reducing RISR. Future efforts for reducing RISR severity should focus on promising interventions, such as Wobe-Mugos E and oral zinc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In vitro studies indicate that folate in collected human blood is vulnerable to degradation after exposure to ultraviolet (UV) radiation. This has raised concerns about folate depletion in individuals with high sun exposure. Here, we investigate the association between personal solar UV radiation exposure and serum folate concentration, using a three-week prospective study that was undertaken in females aged 18–47 years in Brisbane, Australia (153 E, 27 S). Following two weeks of supplementation with 500 μg of folic acid daily, the change in serum folate status was assessed over a 7-day period of measured personal sun exposure. Compared to participants with personal UV exposures of <200 Joules per day, participants with personal UV exposures of 200–599 and >600 Joules per day had significantly higher depletion of serum folate (p = 0.015). Multivariable analysis revealed personal UV exposure as the strongest predictor accounting for 20% of the overall change in serum folate (Standardised B = −0.49; t = −3.75; p = <0.01). These data show that increasing solar UV radiation exposures reduces the effectiveness of folic acid supplementation. The consequences of this association may be most pronounced for vulnerable individuals, such as women who are pregnant or of childbearing age with high sun exposures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigates the variability in response of optically stimulated luminescence dosimeters (OSLDs). Examining the source of sensitivity variations in these dosimeters allows for a more comprehensive understanding of the Landauer nanoDots and their potential for current and future applications. In this work, OSLDs were scanned with a MicroCT scanner to determine potential sources for the variation in relative sensitivity across a selection of Landauer nanoDot dosimeters. Specifically, the correlation between a dosimeters relative sensitivity and the loading density of Al2O3:C powder was determined. When extrapolating the sensitive volume's radiodensity from the CT data, it was shown that there is a non-uniform distribution in crystal growth. It was calculated that a 0.05% change in the nominal volume of the chip produces a 1% change in the overall response. Additionally, the ‘true’ volume of an OSLD's sensitive material is, on average, 18% less than that which has been reported in literature, mainly due to the presence of air cavities in the material's structure. This work demonstrated that the amount of sensitive material is approximately linked to the total correction factor.