147 resultados para Computed tomography


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The primary aim of this study was to determine whether endplate pre-selection makes a difference to the Cobb Angle change between supine and standing which is known to occur in idiopathic scoliosis. A secondary aim of this study was to identify which (if any) patient characteristics were correlated with supine versus standing Cobb change. The study found that pre-selecting vertebral endplates causes only has a minor effect on supine to standing Cobb change in scoliosis. There is a statistically significant relationship between supine to standing Cobb Angle change and fulcrum flexibility. Therefore, supine to standing Cobb Angle change can be considered as a measure of spinal flexibility when both standing and supine images are clinically available.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

To complement the existing treatment guidelines for all tumour types, ESMO organises consensus conferences to focus on specific issues in each type of tumour. The 2nd ESMO Consensus Conference on Lung Cancer was held on 11-12 May 2013 in Lugano. A total of 35 experts met to address several questions on non-small-cell lung cancer (NSCLC) in each of four areas: pathology and molecular biomarkers, first-line/second and further lines in advanced disease, earlystage disease and locally advanced disease. For each question, recommendations were made including reference to the grade of recommendation and level of evidence. This consensus paper focuses on early-stage disease. © The Author 2014. Published by Oxford University Press on behalf of the European Society for Medical Oncology. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Despite the importance of paediatric pneumonia as a cause of short and long-term morbidity and mortality worldwide, a reliable gold standard for its diagnosis remains elusive. The utility of clinical, microbiological and radiological diagnostic approaches varies widely within and between populations and is heavily dependent on the expertise and resources available in various settings. Here we review the role of radiology in the diagnosis of paediatric pneumonia. Chest radiographs (CXRs) are the most widely employed test, however, they are not indicated in ambulatory settings, cannot distinguish between viral and bacterial infections and have a limited role in the ongoing management of disease. A standardised definition of alveolar pneumonia on a CXR exists for epidemiological studies targeting bacterial pneumonias but it should not be extrapolated to clinical settings. Radiography, computed tomography and to a lesser extent ultrasonography and magnetic resonance imaging play an important role in complicated pneumonias but there are limitations that preclude their use as routine diagnostic tools. Large population-based studies are needed in different populations to address many of the knowledge gaps in the radiological diagnosis of pneumonia in children, however, the feasibility of such studies is an important barrier.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Collections of biological specimens are fundamental to scientific understanding and characterization of natural diversity - past, present and future. This paper presents a system for liberating useful information from physical collections by bringing specimens into the digital domain so they can be more readily shared, analyzed, annotated and compared. It focuses on insects and is strongly motivated by the desire to accelerate and augment current practices in insect taxonomy which predominantly use text, 2D diagrams and images to describe and characterize species. While these traditional kinds of descriptions are informative and useful, they cannot cover insect specimens "from all angles" and precious specimens are still exchanged between researchers and collections for this reason. Furthermore, insects can be complex in structure and pose many challenges to computer vision systems. We present a new prototype for a practical, cost-effective system of off-the-shelf components to acquire natural-colour 3D models of insects from around 3 mm to 30 mm in length. ("Natural-colour" is used to contrast with "false-colour", i.e., colour generated from, or applied to, gray-scale data post-acquisition.) Colour images are captured from different angles and focal depths using a digital single lens reflex (DSLR) camera rig and two-axis turntable. These 2D images are processed into 3D reconstructions using software based on a visual hull algorithm. The resulting models are compact (around 10 megabytes), afford excellent optical resolution, and can be readily embedded into documents and web pages, as well as viewed on mobile devices. The system is portable, safe, relatively affordable, and complements the sort of volumetric data that can be acquired by computed tomography. This system provides a new way to augment the description and documentation of insect species holotypes, reducing the need to handle or ship specimens. It opens up new opportunities to collect data for research, education, art, entertainment, biodiversity assessment and biosecurity control. © 2014 Nguyen et al.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The signal-to-noise ratio achievable in x-ray computed tomography (CT) images of polymer gels can be increased by averaging over multiple scans of each sample. However, repeated scanning delivers a small additional dose to the gel which may compromise the accuracy of the dose measurement. In this study, a NIPAM-based polymer gel was irradiated and then CT scanned 25 times, with the resulting data used to derive an averaged image and a "zero-scan" image of the gel. Comparison between these two results and the first scan of the gel showed that the averaged and zero-scan images provided better contrast, higher contrast-to- noise and higher signal-to-noise than the initial scan. The pixel values (Hounsfield units, HU) in the averaged image were not noticeably elevated, compared to the zero-scan result and the gradients used in the linear extrapolation of the zero-scan images were small and symmetrically distributed around zero. These results indicate that the averaged image was not artificially lightened by the small, additional dose delivered during CT scanning. This work demonstrates the broader usefulness of the zero-scan method as a means to verify the dosimetric accuracy of gel images derived from averaged x-ray CT data.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This thesis examines and compares imaging methods used during the radiotherapy treatment of prostate cancer. The studies found that radiation therapists were able to localise and target the prostate consistently with planar imaging techniques and that the use of small gold markers in the prostate reduced the variation in prostate localisation when using volumetric imaging. It was concluded that larger safety margins are required when using volumetric imaging without gold markers.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Progression of spinal deformity in children was studied with Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) to identify how gravity affects the deformity and to determine the full three-dimensional character of the deformity. The CT study showed that gravity is significant in deformity progression in some patients which has implications for clinical patient management. The world first MRI study showed that the standard clinical measure used to define the extent of the deformity is inadequate and further use of three-dimensional MRI should be considered by spinal surgeons.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This thesis introduces a new way of using prior information in a spatial model and develops scalable algorithms for fitting this model to large imaging datasets. These methods are employed for image-guided radiation therapy and satellite based classification of land use and water quality. This study has utilized a pre-computation step to achieve a hundredfold improvement in the elapsed runtime for model fitting. This makes it much more feasible to apply these models to real-world problems, and enables full Bayesian inference for images with a million or more pixels.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Study Design This was a randomised controlled trial in patients with degenerative disc disease (DDD) who underwent instrumented posterolateral lumbar fusion (PLF) surgery. Objective The aim of this study was to assess the efficacy of the bone grafting substitute, silicate-substituted calcium phosphate (SiCaP) compared with bone morphogenetic protein (rhBMP-2) and to evaluate clinical outcomes over a period of two years. Methods Patients undergoing PLF surgery for DDD at a single centre were recruited and randomised to one of two groups; SiCaP (n=9) or rhBMP-2 (n=10). One patient withdrew prior to randomisation and another from the rhBMP-2 group after randomisation. The radiological and clinical outcomes were examined and compared. Fusion was assessed at 12 months with computed tomography (CT) and plain radiographs. Clinical outcomes were evaluated by recording measures of pain, quality of life, disability and neurological status from six weeks to two years postoperatively. Results In the SiCaP and rhBMP-2 groups, fusion was observed in 9/9 and 8/9 patients respectively. Pain and disability scores were reduced and quality of life increased in both groups. Leg pain, disability and satisfaction scores were similar between the groups at each postoperative time point, however, back pain was less at six weeks and quality of life was higher at six months in the SiCaP group than the rhBMP-2 group. Conclusions SiCaP and rhBMP-2 were comparable in terms of achieving successful bone growth and fusion. Both groups similarly alleviated pain and improved quality of life, neurological, satisfaction and return to work outcomes following PLF surgery.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background Context There are differences in definitions of end plate lesions (EPLs), often referred to as Schmorl’s nodes, that may, to some extent, account for the large range of reported prevalence (3.8 to 76%). Purpose To develop a technique to measure the size, prevalence and location of EPLs in a consistent manner. Study Design/Setting This study proposed a method using a detection algorithm which was applied to five adolescent females (average age 15.1 years, range 13.0 to 19.2 years) with idiopathic scoliosis (average major Cobb angle 60°, range 55 to 67°). Methods Existing low-dose, computed tomography scans were segmented semi-automatically to extract 3D morphology of each vertebral endplate. Any remaining attachments to the posterior elements of adjacent vertebrae or endplates were then manually sectioned. An automatic algorithm was used to determine the presence and position of EPLs. Results EPLs were identified in 15 of the 170 (8.8%) endplates analysed with an average depth of 3.1mm. 11/15 of the EPLs were seen in the lumbar spine. The algorithm was found to be most sensitive to changes in the minimum EPL gradient at the edges of the EPL. Conclusions This study describes an imaging analysis technique for consistent measurement of the prevalence, location and size of EPLs. The technique can be used to analyse large populations without observer errors in EPL definitions.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

INTRODUCTION There is a large range in the reported prevalence of end plate lesions (EPLs), sometimes referred to as Schmorl's nodes in the general population (3.8-76%). One possible reason for this large range is the differences in definitions used by authors. Previous research has suggested that EPLs may potentially be a primary disturbance of growth plates that leads to the onset of scoliosis. The aim of this study was to develop a technique to measure the size, prevalence and location of EPLs on Computed Tomography (CT) images of scoliosis patients in a consistent manner. METHODS A detection algorithm was developed and applied to measure EPLs for five adolescent females with idiopathic scoliosis (average age 15.1 years, average major Cobb 60°). In this algorithm, the EPL definition was based on the lesion depth, the distance from the edge of the vertebral body and the gradient of the lesion edge. Existing low-dose, CT scans of the patients' spines were segmented semi-automatically to extract 3D vertebral endplate morphology. Manual sectioning of any attachments between posterior elements of adjacent vertebrae and, if necessary, endplates was carried out before the automatic algorithm was used to determine the presence and position of EPLs. RESULTS EPLs were identified in 15 of the 170 (8.8%) endplates analysed with an average depth of 3.1mm. 73% of the EPLs were seen in the lumbar spines (11/15). A sensitivity study demonstrated that the algorithm was most sensitive to changes in the minimum gradient required at the lesion edge. CONCLUSION An imaging analysis technique for consistent measurement of the prevalence, location and size of EPLs on CT images has been developed. Although the technique was tested on scoliosis patients, it can be used to analyse other populations without observer errors in EPL definitions.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective. Twelve families that were multiply affected with diffuse idiopathic skeletal hyperostosis (DISH) and/or chondrocalcinosis, were identified on the island of Terceira, The Azores, potentially supporting the hypothesis that the 2 disorders share common etiopathogenic factors. The present study was undertaken to investigate this hypothesis. Methods. One hundred three individuals from 12 unrelated families were assessed. Probands were identified from patients attending the Rheumatic Diseases Clinic, Hospital de Santo Espirito, in The Azores. Family members were assessed by rheumatologists and radiologists. Radiographs of all family members were obtained, including radiographs of the dorsolumbar spine, pelvis, knees, elbows, and wrists, and all cases were screened for known features of chondrocalcinosis. Results. Ectopic calcifications were identified in 70 patients. The most frequent symptoms or findings were as follows: axial pain, elbow, knee and metacarpophalangeal (MCP) joint pain, swelling, and/or deformity, and radiographic enthesopathic changes. Elbow and MCP joint periarticular calcifications were observed in 35 and 5 patients, respectively, and chondrocalcinosis was identified in 12 patients. Fifteen patients had sacroiliac disease (ankylosis or sclerosis) on computed tomography scans. Fifty-two patients could be classified as having definite (17%), probable (26%), or possible (31%) DISH. Concomitant DISH and chondrocalcinosis was diagnosed in 12 patients. Pyrophosphate crystals were identified from knee effusions in 13 patients. The pattern of disease transmission was compatible with an autosomal-dominant monogenic disease. The mean age at which symptoms developed was 38 years. Conclusion. These families may represent a familial type of pyrophosphate arthropathy with a phenotype that includes peripheral and axial enthesopathic calcifications. The concurrence of DISH and chondrocalcinosis suggests a shared pathogenic mechanism in the 2 conditions.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study reports on an original concept of additive manufacturing for the fabrication of tissue engineered constructs (TEC), offering the possibility of concomitantly manufacturing a customized scaffold and a bioreactor chamber to any size and shape. As a proof of concept towards the development of anatomically relevant TECs, this concept was utilized for the design and fabrication of a highly porous sheep tibia scaffold around which a bioreactor chamber of similar shape was simultaneously built. The morphology of the bioreactor/scaffold device was investigated by micro-computed tomography and scanning electron microscopy confirming the porous architecture of the sheep tibiae as opposed to the non-porous nature of the bioreactor chamber. Additionally, this study demonstrates that both the shape, as well as the inner architecture of the device can significantly impact the perfusion of fluid within the scaffold architecture. Indeed, fluid flow modelling revealed that this was of significant importance for controlling the nutrition flow pattern within the scaffold and the bioreactor chamber, avoiding the formation of stagnant flow regions detrimental for in vitro tissue development. The bioreactor/scaffold device was dynamically seeded with human primary osteoblasts and cultured under bi-directional perfusion for two and six weeks. Primary human osteoblasts were observed homogenously distributed throughout the scaffold, and were viable for the six week culture period. This work demonstrates a novel application for additive manufacturing in the development of scaffolds and bioreactors. Given the intrinsic flexibility of the additive manufacturing technology platform developed, more complex culture systems can be fabricated which would contribute to the advances in customized and patient-specific tissue engineering strategies for a wide range of applications.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVE: Idiopathic pulmonary fibrosis (IPF) is a degenerative disease characterized by fibrosis following failed epithelial repair. Mesenchymal stromal cells (MSC), a key component of the stem cell niche in bone marrow and possibly other organs including lung, have been shown to enhance epithelial repair and are effective in preclinical models of inflammation-induced pulmonary fibrosis, but may be profibrotic in some circumstances. METHODS: In this single centre, non-randomized, dose escalation phase 1b trial, patients with moderately severe IPF (diffusing capacity for carbon monoxide (DLCO ) ≥ 25% and forced vital capacity (FVC) ≥ 50%) received either 1 × 10(6) (n = 4) or 2 × 10(6) (n = 4) unrelated-donor, placenta-derived MSC/kg via a peripheral vein and were followed for 6 months with lung function (FVC and DLCO ), 6-min walk distance (6MWD) and computed tomography (CT) chest. RESULTS: Eight patients (4 female, aged 63.5 (57-75) years) with median (interquartile range) FVC 60 (52.5-74.5)% and DLCO 34.5 (29.5-40)% predicted were treated. Both dose schedules were well tolerated with only minor and transient acute adverse effects. MSC infusion was associated with a transient (1% (0-2%)) fall in SaO2 after 15 min, but no changes in haemodynamics. At 6 months FVC, DLCO , 6MWD and CT fibrosis score were unchanged compared with baseline. There was no evidence of worsening fibrosis. CONCLUSIONS: Intravenous MSC administration is feasible and has a good short-term safety profile in patients with moderately severe IPF.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Molecular imaging is utilised in modern medicine to aid in the diagnosis and treatment of disease by allowing its spatiotemporal state to be examined in vivo. This study focuses on the development of novel multimodal molecular imaging agents based on hyperbranched polymers that combine the complementary capabilities of optical fluorescence imaging and positron emission tomography-computed tomography (PET/CT) into one construct. RAFT-mediated polymerisation was used to prepare two hydrophilic hyperbranched polymers that were differentiated by their size and level of branching. The multiple functional end-groups facilitated covalent attachment of both near infrared fluorescent dyes for optical imaging, as well as a copper chelator allowing binding of 64Cu as a PET radio nuclei. In vivo multimodal imaging of mice using PET/CT and planar optical imaging was first used to assess the biodistribution of the polymeric materials and it was shown that the larger and more branched polymer had a significantly longer circulation time. The larger constructs were also shown to exhibit enhanced accumulation in solid tumours in a murine B16 melanoma model. Importantly, it was demonstrated that the PET modality gave rise to high sensitivity immediately after injection of the agent, while the optical modality facilitated extended longitudinal studies, thus highlighting how the complementary capabilities of the molecular imaging agents can be useful for studying various diseases, including cancer.