116 resultados para ultrasound


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Arterial mechanical property may be a potential variable for risk stratification. Large artery and central arterial compliance have been shown not only to correlate well with overall cardiovascular outcome in large epidemiological studies [1, 2] but also to correlate with coronary atherosclerotic burden as measured by conventional angiography [3]. Until recently, real-time B-mode ultrasound combined with simultaneous blood pressure measurements have been used to assess large artery compliance [4]. These techniques have an excellent temporal resolution but are unable to provide adequate spatial resolution to determine changes in vessel area as opposed to diameter and make the assumption that the vessel is perfectly round. Attempts to use MR imaging to measure large artery compliance have been published previously [5]. However, they have not utilised simultaneous blood pressure measurements during sequence acquisition. We report a technique using regular and simultaneous blood pressure measurement during 2 dimensional phase contrast magnetic resonance imaging 2DPC-MRI to determine local carotid compliance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background and purpose: To prospectively evaluate differences in carotid plaque characteristics in symptomatic and asymptomatic patients using high resolution MRI. Methods: 20 symptomatic and 20 asymptomatic patients, with at least 50% carotid stenosis as determined by Doppler ultrasound, underwent preoperative in vivo multispectral MRI of the carotid arteries. Studies were analysed both qualitatively and quantitatively in a randomised manner by two experienced readers in consensus, blinded to clinical status, and plaques were classified according to the modified American Heart Association (AHA) criteria. Results: After exclusion of poor quality images, 109 MRI sections in 18 symptomatic and 19 asymptomatic patients were available for analysis. There were no significant differences in mean luminal stenosis severity (72.9% vs 67.6%; p = 0.09) or plaque burden (median plaque areas 50 mm2 vs 50 mm 2; p = 0.858) between the symptomatic and asymptomatic groups. However, symptomatic lesions had a higher incidence of ruptured fibrous caps (36.5% vs 8.7%; p = 0.004), haemorrhage or thrombus (46.5% vs 14.0%; p<0.001), large necrotic lipid cores (63.8% vs 28.0%; p = 0.002) and complicated type VI AHA lesions (61.5% vs 28.1%; p = 0.001) compared with asymptomatic lesions. The MRI findings of plaque haemorrhage or thrombus had an odds ratio of 5.25 (95% CI 2.08 to 13.24) while thin or ruptured fibrous cap (as opposed to a thick fibrous cap) had an odds ratio of 7.94 (95% CI 2.93 to 21.51) for prediction of symptomatic clinical status. Conclusions: There are significant differences in plaque characteristics between symptomatic and asymptomatic carotid atheroma and these can be detected in vivo by high resolution MRI.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Arterial compliance has been shown to correlate well with overall cardiovascular outcome and it may also be a potential risk factor for the development of atheromatous disease. This study assesses the utility of 2-D phase contrast Magnetic Resonance (MR) imaging with intra-sequence blood pressure measurement to determine carotid compliance and distensibility. 20 patients underwent 2-D phase contrast MR imaging and also ultrasound-based wall tracking measurements. Values for carotid compliance and distensibility were derived from the two different modalities and compared. Linear regression analysis was utilised to determine the extent of correlation between MR and ultrasound derived parameters. In those variables that could be directly compared, an agreement analysis was undertaken. MR measures of compliance showed a good correlation with measures based on ultrasound wall-tracking (r=0.61, 95% CI 0.34 to 0.81 p=0.0003). Vessels that had undergone carotid endarterectomy previously were significantly less compliant than either diseased or normal contralateral vessels (p=0.04). Agreement studies showed a relatively poor intra-class correlation coefficient (ICC) between diameter-based measures of compliance through either MR or ultrasound (ICC=0.14). MRI based assessment of local carotid compliance appears to be both robust and technically feasible in most subjects. Measures of compliance correlate well with ultrasound-based values and correlate best when cross-sectional area change is used rather than derived diameter changes. If validated by further larger studies, 2-D phase contrast imaging with intra-sequence blood pressure monitoring and off-line radial artery tonometry may provide a useful tool in further assessment of patients with carotid atheroma.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

- Study Design Controlled laboratory study - Objective To investigate the effect of a 12–mm in–shoe orthotic heel lift on Achilles tendon loading during shod walking using transmission–mode ultrasonography. - Background Orthotic heel lifts are thought to lower tension in the Achilles tendon but evidence for this effect is equivocal. - Methods The propagation speed of ultrasound, which is governed by the elastic modulus and density of tendon and is proportional to the tensile load to which it is exposed, was measured in the right Achilles tendon of twelve recreationally–active males during shod treadmill walking at matched speeds (3.4±0.7 km/h), with and without addition of a heel lift. Vertical ground reaction force and spatiotemporal gait parameters were simultaneously recorded. Data were acquired at 100Hz during 10s of steady–state walking. Statistical comparisons were made using paired t–tests (α=.05). - Results Ultrasound transmission speed in the Achilles tendon was characterized by two maxima (P1, P2) and minima (M1, M2) during walking. Addition of a heel lift to footwear resulted in a 2% increase and 2% decrease in the first vertical ground reaction force peak and the local minimum, respectively (P<.05). Peak ultrasonic velocity in the Achilles tendon (P1, P2, M2) was significantly lower with addition of an orthotic heel lift (P<.05). - Conclusions Peak ultrasound transmission speed in the Achilles tendon was lower with the addition of a 12–mm orthotic heel lift, indicating the heel lift reduced tensile load in the Achilles tendon, thereby counteracting the effect of footwear. These findings support the addition of orthotic heel lifts to footwear in the rehabilitation of Achilles tendon disorders where management aims to lower tension within the tendon. - Level of Evidence Therapy, level 2a

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Measurement of tendon loading patterns during gait is important for understanding the pathogenesis of tendon "overuse" injury. Given that the speed of propagation of ultrasound in tendon is proportional to the applied load, this study used a noninvasive ultrasonic transmission technique to measure axial ultrasonic velocity in the right Achilles tendon of 27 healthy adults (11 females and 16 males; age, 26 ± 9 years; height, 1.73 ± 0.07 m; weight, 70.6 ± 21.2 kg), walking at self-selected speed (1.1 ± 0.1 m/s), and running at fixed slow speed (2 m/s) on a treadmill. Synchronous measures of ankle kinematics, spatiotemporal gait parameters, and vertical ground reaction forces were simultaneously measured. Slow running was associated with significantly higher cadence, shorter step length, but greater range of ankle movement, higher magnitude and rate of vertical ground reaction force, and higher ultrasonic velocity in the tendon than walking (P < 0.05). Ultrasonic velocity in the Achilles tendon was highly reproducible during walking and slow running (mean within-subject coefficient of variation < 2%). Ultrasonic maxima (P1, P2) and minima (M1, M2) were significantly higher and occurred earlier in the gait cycle (P1, M1, and M2) during running than walking (P < 0.05). Slow running was associated with higher and earlier peaks in loading of the Achilles tendon than walking.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim was to investigate the effects of the GABAB receptor antagonist, CGP46381, on form-deprivation myopia (FDM) in guinea pigs. Twenty-four guinea pigs had monocular visual deprivation induced using a diffuser for 11 days (day 14 to 25). The deprived eyes were treated with daily subconjunctival injections (100 μl) of either 2% CGP46381, 0.2% CGP46381, or saline or received no injection. The fellow eyes were left untreated. Another six animals received no treatment. At the start and end of the treatment period, ocular refractions were measured using retinoscopy and vitreous chamber depth (VCD) and axial length (AL) using A-scan ultrasound. All of the deprived eyes developed relative myopia (treated versus untreated eyes, P < 0.05). The amount of myopia was significantly affected by the drug treatment (one-way ANOVA, P < 0.0001). The highest dose tested, 2% CGP46381, significantly inhibited myopia development compared to saline (2% CGP46381: -1.08 ± 0.40 D, saline: -4.33 ± 0.67 D, P < 0.01). The majority of these effects were due to less AL (2% CGP46381: 0.03 ± 0.01 mm, saline: 0.13 ± 0.02 mm, P < 0.01) and VCD (2% CGP46381: 0.02 ± 0.01 mm, saline: 0.08 ± 0.01 mm, P < 0.01) elongation. The lower dose tested, 0.2% CGP46381, did not significantly inhibit FDM (P > 0.05). Subconjunctival injections of CGP46381 inhibit FDM development in guinea pigs in a dose-dependent manner.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Traditionally twins are classified as dizygous or fraternal and monozygous or identical (Hall Twinning, 362, 2003 and 735-743). We report a rare case of 46,XX/46,XY twins: Twin A presented with ambiguous genitalia and Twin B was a phenotypically normal male. These twins demonstrate a third, previously unreported mechanism for twinning. The twins underwent initial investigation with 17-hydroxyprogesterone and testosterone levels, pelvic ultrasound and diagnostic laparoscopy. Cytogenetic analysis was performed on peripheral blood cells and skin fibroblasts. Histological examination and Fluorescence in situ hybridization studies on touch imprints were performed on gonadal biopsies. DNA analysis using more than 6,000 DNA markers was performed on skin fibroblast samples from the twins and on peripheral blood samples from both parents. Twin A was determined to be a true hermaphrodite and Twin B an apparently normal male. Both twins had a 46,XX/46,XY chromosome complement in peripheral lymphocytes, skin fibroblasts, and gonadal biopsies. The proportion of XX to XY cells varied between the twins and the tissues evaluated. Most significantly the twins shared 100% of maternal alleles and approximately 50% of paternal alleles in DNA analysis of skin fibroblasts. The twins are chimeric and share a single genetic contribution from their mother but have two genetic contributions from their father thus supporting the existence of a third, previously unreported type of twinning.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sonographic diagnosis of appendicitis in children is an important clinical tool, often obviating the need for potentially harmful ionising radiation from computed tomography (CT) scans and unnecessary appendectomies. Established criteria do not commonly account for the sonographic secondary signs of acute appendicitis as an adjunct or corollary to an identifiably inflamed appendix. If one of, or combinations of these secondary signs are a reliable positive and/or negative indicator of the condition, diagnostic accuracy may be improved. This will be of particular importance in cases where the appendix cannot be easily identified, possibly providing referring clinicians with a less equivocal diagnosis. Acute appendicitis (AA) is the most common emergency presentation requiring surgical intervention among both adults and children. During 2010-11 in Australia 25000 appendicectomies were performed on adults and children, more than double the number of the next most common surgical procedure [1]. Ultrasound has been commonly used to diagnose AA since the 1980s, however the best imaging modality or combination of modalities to accurately and cost-effectively diagnose the condition is still debated. A study by Puylaert advocated ultrasound in all presentations [2], whereas others suggested it only as a first line modality [3–5]. Conversely, York et al state that it is not appropriate as it delays treatment [6]. CT has been shown to more accurately diagnose AA than ultrasound, however its inherent radiation risks warrant cautionary use in children [7]. Improved accuracy in the diagnosis of suspected AA using ultrasound would enable surgeons to make a decision without the need to expose children to the potentially harmful effects of CT. Secondary signs of appendicitis are well established [8], although research into their predictive values has only recently been undertaken [9,10] indicating their potential diagnostic benefit in the absence of an identifiable appendix. The purpose of this review is to examine the history of appendiceal sonography, established sonographic criteria, paediatric specific techniques and the predictive value of secondary signs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION There is a paucity of research investigating the scar outcome of children with partial thickness burns. The aim of this study was to assess the scar outcome of children with partial thickness burns who received a silver dressing acutely. METHOD Children aged 0-15 years with an acute partial thickness burn, ≤10% TBSA were included. Children were originally recruited for an RCT investigating three dressings for partial thickness burns. Children were assessed at 3 and 6 months after re-epithelialization. 3D photographs were taken of the burn site, POSAS was completed and skin thickness was measured using ultrasound imaging. RESULTS Forty-three children returned for 3 and 6 month follow-ups or returned a photo. Days to re-epithelialization was a significant predictor of skin/scar quality at 3 and 6 months (p<0.01). Patient-rated color and observer-rated vascularity and pigmentation POSAS scores were comparable at 3 months (color vs. vascularity 0.88, p<0.001; color vs. pigmentation 0.64, p<0.001), but patients scored higher than the observer at 6 months (color vs. vascularity 0.57, p<0.05; color vs. pigmentation 0.15, p=0.60). Burn depth was significantly correlated with skin thickness (r=0.51, p<0.01). Hypopigmentation of the burn site was present in 25.8% of children who re-epithelialized in ≤2 weeks. CONCLUSION This study has provided information on outcomes for children with partial thickness burns and highlighted a need for further education of this population.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We have used B-mode (brightness-mode) ultrasound to investigate the fascial planes within subcutaneous fat at the triceps and abdominal sites in a group of 17 women attending a weight control group over a 12 month period. In most subjects there was a single intralipid fascial plane at each site. As the thickness of adipose tissue increased, most of the change at the abdominal site was in the deep rather than the superficial layer of fat. At the triceps site both deep and superficial layers increased. Our findings confirm the presence of two different layers in human subcutaneous fat at the triceps and abdominal sites. These layers have been shown to be functionally different in animals and our study supports this in humans at the abdominal site.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

- Background Sonography is an important diagnostic tool in children with suspected appendicitis. Reported accuracy and appendiceal visualisation rates vary significantly, as does the management of equivocal ultrasound findings. The aim of this study was to audit appendiceal sonography at a tertiary children's hospital, and provide baseline data for a future prospective study. - Summary of work Records of children who underwent ultrasound studies for possible appendicitis between January 2008 and December 2010 were reviewed. Variables included patient demographics, sonographic appendix characteristics, and secondary signs. Descriptive statistics and analysis using ANOVA, Mann-Whitney U test, and ROC curves were performed. Mater Human Research Ethic Committee approval was granted. - Summary of results There were 457 eligible children. Using a dichotomous diagnostic model (including equivocal results), sensitivity was 89.6%, specificity 91.6%, and diagnostic yield of 40.7%. ROC curve analysis of a 6mm diameter cut-off was 0.88 AUC (95% CI 0.80 to 0.95). - Discussion and conclusions Sonography is an accurate test for acute appendicitis in children, with a high sensitivity and negative predictive value. A diameter of 6mm as an absolute cut-off in a binary model can lead to false findings. Results were compared with available literature. Recent publications propose categorising diameter1 and integrating secondary signs2 to improve accuracy and provide more meaningful results to clinicians. This study will be a benchmark for future studies with multiple diagnostic categorisation.