222 resultados para rigid contact lenses


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper is concerned with the surface profiles of a strip after rigid bodies with serrated (saw-teeth) surfaces indent the strip and are subsequently removed. Plane-strain conditions are assumed. This has application in roughness transfer of final metal forming process. The effects of the semi-angle of the teeth, the depth of indentation and the friction on the contact surface on the profile are considered.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The aim of this study was to characterize the clinical signs, symptoms, and ocular and systemic comorbidities in a large case series of contact lens-related microbial keratitis. Methods: Two hundred ninety-seven cases of contact lens-related microbial keratitis, aged between 15 and 64 years were detected through surveillance of hospital and community based ophthalmic practitioners in Australia and New Zealand. Full clinical data were available for 190 cases and 90 were interviewed by telephone. Clinical data included the size, location, and degree of anterior chamber response. Symptom data were available from the practitioner and from participant self-report. Associations between symptoms and disease severity were evaluated. Data on ocular and systemic disease were collected from participants and practitioners. The frequency of comorbidities was compared between the different severities of disease and to population norms. Results: More severe disease was associated with greater symptom severity and pain was the most prevalent symptom reported. Ninety-one percent of cases showed progression of ocular symptoms after lens removal, and symptom progression was associated with all severities of disease. Twenty-five percent of cases reported prior episodes requiring emergency attention. Thyroid disease (p 0.05) and self-reported poor health (p 0.001) were more common in cases compared with age-matched population norms. Discussion: Information on the signs, symptoms, and comorbidities associated with contact lens-related microbial keratitis may be useful in patient education and for practitioners involved in the fitting of lenses and management of complications. Although pain was the most common symptom experienced, progression of symptoms despite lens removal was close to universal. Poor general health, particularly respiratory disease and thyroid disease was more common in cases than in the general population, which may prompt practitioners to recommend flexibility in wear schedules when in poor health or the selection of a lower risk wear schedule in at risk patients

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The ageing population highlights the need to provide effective optical solutions for presbyopic contact lens wearers. However, data gathered from annual contact lens fitting surveys demonstrate that fewer than 40% of contact lens wearers over 45 years of age (virtually all of whom can be presumed to suffer a partial or complete loss of accommodation) are prescribed a presbyopic correction. Furthermore, monovision is prescribed as frequently as multifocal lenses. These observations suggest that an optimal solution to the contact lens correction of presbyopia remains elusive.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An algorithm to improve the accuracy and stability of rigid-body contact force calculation is presented. The algorithm uses a combination of analytic solutions and numerical methods to solve a spring-damper differential equation typical of a contact model. The solution method employs the recently proposed patch method, which especially suits the spring-damper differential equations. The resulting semi-analytic solution reduces the stiffness of the differential equations, while performing faster than conventional alternatives.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

There have been significant improvements in toric soft contact lens design over the past decade. Data from our international contact lens prescribing survey were mined to assess recent trends in toric soft contact lens fitting. This survey was conducted by sending up to 1000 survey forms to contact lens fitters in Australia, Canada, Japan, the Netherlands, Norway, the UK and the USA each year between 2000 and 2009. Practitioners were asked to record data relating to the first 10 contact lens fits or refits performed after receiving the forms and to return them to us for analysis. The data revealed a gradual increase in the extent of toric soft lens fitting this century. Excluding Japan – which had a consistently low rate of soft toric lens fitting over the survey period – soft toric lenses now represent over 35% of all soft lenses prescribed; it can be assumed that, on average (and again excluding Japan), all cases of astigmatism 0.75 D or less remains uncorrected among contact lens wearers. Toric lenses are fitted more to those who are older, full-time wearers and reusable lens wearers, and less to those wearing silicone hydrogel and extended wear lenses.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Current contact lens prescribing data speaks for itself: GP lenses represented 5 percent or less of fits in 13 of the 27 countries examined in the February 2009 article "International Contact Lens Prescribing in 2008" by Morgan et al. GP lens fitting is becoming a specialist activity undertaken by a minority of practitioners. I believe the question is no longer: "Are GP lenses on the decline?" but rather: "Why are GP lenses on the decline?" So, here I'll try to answer the latter question.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This is the eighth consecutive year that we have presented data from a survey of international contact lens prescribing in Contact Lens Spectrum. In this article we report on an assessment of 25,801 fits across 28 contact lens markets located in North America, Europe, the Middle East, Asia, and Africa. As in previous years, we opted for a prospective approach to this work. Up to 1,000 survey forms were randomly disseminated in each market to contact lens practitioners (ophthalmologists, optometrists, and/or opticians depending on the market), and information about the first 10 patients prescribed with lenses after receipt of paper or electronic survey forms was anonymously recorded.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The results of the annual survey on international contact lens fits have become available again, which presents a great opportunity to distill the RGP lens data to see what the status of RGP lenses is today as well as to revisit the last decade of RGP lens fitting and to look ahead to the next decade.

Relevância:

30.00% 30.00%

Publicador:

Relevância:

30.00% 30.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hand hygiene is critical in the healthcare setting and it is believed that methicillin-resistant Staphylococcus aureus (MRSA), for example, is transmitted from patient to patient largely via the hands of health professionals. A study has been carried out at a large teaching hospital to estimate how often the gloves of a healthcare worker are contaminated with MRSA after contact with a colonized patient. The effectiveness of handwashing procedures to decontaminate the health professionals' hands was also investigated, together with how well different healthcare professional groups complied with handwashing procedures. The study showed that about 17% (9–25%) of contacts between a healthcare worker and a MRSA-colonized patient results in transmission of MRSA from a patient to the gloves of a healthcare worker. Different health professional groups have different rates of compliance with infection control procedures. Non-contact staff (cleaners, food services) had the shortest handwashing times. In this study, glove use compliance rates were 75% or above in all healthcare worker groups except doctors whose compliance was only 27%.