187 resultados para neighbourhood size
Resumo:
Results of an interlaboratory comparison on size characterization of SiO2 airborne nanoparticles using on-line and off-line measurement techniques are discussed. This study was performed in the framework of Technical Working Area (TWA) 34—“Properties of Nanoparticle Populations” of the Versailles Project on Advanced Materials and Standards (VAMAS) in the project no. 3 “Techniques for characterizing size distribution of airborne nanoparticles”. Two types of nano-aerosols, consisting of (1) one population of nanoparticles with a mean diameter between 30.3 and 39.0 nm and (2) two populations of non-agglomerated nanoparticles with mean diameters between, respectively, 36.2–46.6 nm and 80.2–89.8 nm, were generated for characterization measurements. Scanning mobility particle size spectrometers (SMPS) were used for on-line measurements of size distributions of the produced nano-aerosols. Transmission electron microscopy, scanning electron microscopy, and atomic force microscopy were used as off-line measurement techniques for nanoparticles characterization. Samples were deposited on appropriate supports such as grids, filters, and mica plates by electrostatic precipitation and a filtration technique using SMPS controlled generation upstream. The results of the main size distribution parameters (mean and mode diameters), obtained from several laboratories, were compared based on metrological approaches including metrological traceability, calibration, and evaluation of the measurement uncertainty. Internationally harmonized measurement procedures for airborne SiO2 nanoparticles characterization are proposed.
Resumo:
A nanoparticles size is one of their key physical characteristics that can affect their fate in a human’s respiratory tract (in case of inhalation) and also in the environment. Hence, measuring the size distribution of nanoparticles is absolutely essential and contributes greatly to their characterization. For years, Scanning Mobility Particle Sizers (SMPS), which rely on measuring the electrical mobility diameter of particles, have been used as one of the most reliable real-time instruments for the size distribution measurement of nanoparticles. Despite its benefits, this instrument has some drawbacks, including equivalency problems for non-spherical particles (i.e. assuming a non-spherical particle is equal to a spherical particle of diameter d due to the same electrical mobility), as well as limitations in terms of its use in workplaces, because of its large size and the complexity of its operation...
Resumo:
A technique for analysing exhaust emission plumes from unmodified locomotives under real world conditions is described and applied to the task of characterizing plumes from railway trains servicing an Australian shipping port. The method utilizes the simultaneous measurement, downwind of the railway line, of the following pollutants; particle number, PM2.5 mass fraction, SO2, NOx and CO2, with the last of these being used as an indicator of fuel combustion. Emission factors are then derived, in terms of number of particles and mass of pollutant emitted per unit mass of fuel consumed. Particle number size distributions are also presented. The practical advantages of the method are discussed including the capacity to routinely collect emission factor data for passing trains and to thereby build up a comprehensive real world database for a wide range of pollutants. Samples from 56 train movements were collected, analyzed and presented. The quantitative results for emission factors are: EF(N)=(1.7±1)×1016 kg-1, EF(PM2.5)= (1.1±0.5) g·kg-1, EF(NOx)= (28±14) g·kg-1, and EF(SO2 )= (1.4±0.4) g·kg-1. The findings are compared with comparable previously published work. Statistically significant (p<α, α=0.05) correlations within the group of locomotives sampled were found between the emission factors for particle number and both SO2 and NOx.
Resumo:
The question as to whether poser race affects the happy categorization advantage, the faster categorization of happy than of negative emotional expressions, has been answered inconsistently. Hugenberg (2005) found the happy categorization advantage only for own race faces whereas faster categorization of angry expressions was evident for other race faces. Kubota and Ito (2007) found a happy categorization advantage for both own race and other race faces. These results have vastly different implications for understanding the influence of race cues on the processing of emotional expressions. The current study replicates the results of both prior studies and indicates that face type (computer-generated vs. photographic), presentation duration, and especially stimulus set size influence the happy categorization advantage as well as the moderating effect of poser race.
Role of particle size and composition in metal adsorption by solids deposited on urban road surfaces
Resumo:
Despite common knowledge that the metal content adsorbed by fine particles is relatively higher compared to coarser particles, the reasons for this phenomenon has gained little research attention. The research study discussed in the paper investigated the variations in metal content for different particle sizes of solids associated with pollutant build-up on urban road surfaces. Data analysis confirmed that parameters favourable for metal adsorption to solids such as specific surface area, organic carbon content, effective cation exchange capacity and clay forming minerals content decrease with the increase in particle size. Furthermore, the mineralogical composition of solids was found to be the governing factor influencing the specific surface area and effective cation exchange capacity. There is high quartz content in particles >150µm compared to particles <150µm. As particle size reduces below 150µm, the clay forming minerals content increases, providing favourable physical and chemical properties that influence adsorption.
Resumo:
This study investigates the use of patterned collectors to increase the pore size of electrospun scaffolds for enhanced cell infiltration. The morphology of the patterned scaffolds was investigated by scanning electron microscopy, which showed that the collector pattern was accurately mimicked by the electrospun fibres. We observed an enlargement in the pore size and in the pore size distribution compared with conventional electrospinning. Mechanical testing revealed that the mechanical properties could be tailored, to some extent, according to the patterning and that the patterned scaffolds were softer than standard electrospun scaffolds. When NIH 3T3 fibroblasts were seeded onto patterned collectors improved cell infiltration was observed. Cells were able to penetrate up to 250 μm into the scaffolds, compared with 30 μm for the standard scaffolds. This increase in the depth of infiltration occurred as early as 24 h post-seeding and remained constant over 7 days.
Resumo:
This research paper examines the potential of neighbourhood centres to generate and enhance social capital through their programs, activities, membership associations and community engagement. Social capital is a complex concept involving elements of norms, networks, and trust and is generally seen as enhancing community cohesion and the ability to attain common goals (outlined in more detail in Section 3). The aim of this research project is to describe the nature of social capital formation in terms of development and change in norms, networks and trust within the context of the operations of neighbourhood centres in three Queensland locations (i.e., Sherwood, Kingston/Slacks Creek, and Maleny). The study was prompted by surprisingly little research into how neighbourhood centres and their clients contribute to the development of social capital. Considering the large volume of research on the role of community organisations in building social capital, it is remarkable that perhaps the most obvious organisation with 'social capitalist' intentions has received so little attention (apart from Bullen and Onyx, 2005). Indeed, ostensibly, neighbourhood centres are all about social capital.
Resumo:
Bangkok Metropolitan Region (BMR) is the centre for various major activities in Thailand including political, industry, agriculture, and commerce. Consequently, the BMR is the highest and most densely populated area in Thailand. Thus, the demand for houses in the BMR is also the largest, especially in subdivision developments. For these reasons, the subdivision development in the BMR has increased substantially in the past 20 years and generated large numbers of subdivision developments (AREA, 2009; Kridakorn Na Ayutthaya & Tochaiwat, 2010). However, this dramatic growth of subdivision development has caused several problems including unsustainable development, especially for subdivision neighbourhoods, in the BMR. There have been rating tools that encourage the sustainability of neighbourhood design in subdivision development, but they still have practical problems. Such rating tools do not cover the scale of the development entirely; and they concentrate more on the social and environmental conservation aspects, which have not been totally accepted by the developers (Boonprakub, 2011; Tongcumpou & Harvey, 1994). These factors strongly confirm the need for an appropriate rating tool for sustainable subdivision neighbourhood design in the BMR. To improve level of acceptance from all stakeholders in subdivision developments industry, the new rating tool should be developed based on an approach that unites the social, environmental, and economic approaches, such as eco-efficiency principle. Eco-efficiency is the sustainability indicator introduced by the World Business Council for Sustainable Development (WBCSD) since 1992. The eco-efficiency is defined as the ratio of the product or service value according to its environmental impact (Lehni & Pepper, 2000; Sorvari et al., 2009). Eco-efficiency indicator is concerned to the business, while simultaneously, is concerned with to social and the environment impact. This study aims to develop a new rating tool named "Rating for sustainable subdivision neighbourhood design (RSSND)". The RSSND methodology is developed by a combination of literature reviews, field surveys, the eco-efficiency model development, trial-and-error technique, and the tool validation process. All required data has been collected by the field surveys from July to November 2010. The ecoefficiency model is a combination of three different mathematical models; the neighbourhood property price (NPP) model, the neighbourhood development cost (NDC) model, and the neighbourhood occupancy cost (NOC) model which are attributable to the neighbourhood subdivision design. The NPP model is formulated by hedonic price model approach, while the NDC model and NOC model are formulated by the multiple regression analysis approach. The trial-and-error technique is adopted for simplifying the complex mathematic eco-efficiency model to a user-friendly rating tool format. Credibility of the RSSND has been validated by using both rated and non-rated of eight subdivisions. It is expected to meet the requirements of all stakeholders which support the social activities of the residents, maintain the environmental condition of the development and surrounding areas, and meet the economic requirements of the developers.
Resumo:
This paper presents the findings of an analysis of the activities of rural nurses from a national audit of the role and function of the rural nurse (Hegney, Pearson and McCarthy 1997). The results suggest that the size of the health service (defined by the number of acute beds) influences the activities of rural nurses. Further, the study reports on the differences of the context of practice between different size rural health services and the impact this has on the scope of rural nursing practice. The paper will conclude that the size of the health service is an outcome of rurality (small population densities, distance from larger health facilities, lack of on-site medical and allied health staff). It also notes that the size of the health service is a major contextual determinant of patient acuity and staff skill-mix in small rural hospitals, and therefore the scope of rural nursing practice.
Resumo:
Background The size of the carrier influences the aerosolization of drug from a dry powder inhaler (DPI) formulation. Currently, lactose monohydrate particles in a variety of sizes are preferably used in carrier based DPI formulations of various drugs; however, contradictory reports exist regarding the effect of the size of the carrier on the dispersion of drug. In this study we examined the influence of the intrinsic particle size of the polymeric carrier on the aerosolization of a model drug salbutamol sulphate (SS). Methods Four different sizes (20–150 lm) of polymer carriers were fabricated using solvent evaporation technique and the dispersion of SS particles from these carriers was measured by a Twin Stage Impinger (TSI). The size and morphological properties of polymer carriers were by laser diffraction and SEM, respectively. Results The FPF from these carriers was found to be increasing from 5.6% to 21.3% with increasing the carrier size. The FPF was found to be greater (21%) with the highest particle size of the carrier (150 lm). Conclusions The aerosolization of drug was dependent on the size of polymer carriers. The smaller size of the carrier resulted in lower FPF which was increased with increasing the carrier size. For a fixed mass of drug particles in a formulation, the mass of drug particles per unit area of carriers is higher in formulations containing the larger carriers, which leads to an increase in the dispersion of drug due to the increased mechanical forces occurred between the carriers and the device walls.
Resumo:
Timely and comprehensive scene segmentation is often a critical step for many high level mobile robotic tasks. This paper examines a projected area based neighbourhood lookup approach with the motivation towards faster unsupervised segmentation of dense 3D point clouds. The proposed algorithm exploits the projection geometry of a depth camera to find nearest neighbours which is time independent of the input data size. Points near depth discontinuations are also detected to reinforce object boundaries in the clustering process. The search method presented is evaluated using both indoor and outdoor dense depth images and demonstrates significant improvements in speed and precision compared to the commonly used Fast library for approximate nearest neighbour (FLANN) [Muja and Lowe, 2009].
Access to commercial destinations within the neighbourhood and walking among Australian older adults
Resumo:
BACKGROUND: Physical activity, particularly walking, is greatly beneficial to health; yet a sizeable proportion of older adults are insufficiently active. The importance of built environment attributes for walking is known, but few studies of older adults have examined neighbourhood destinations and none have investigated access to specific, objectively-measured commercial destinations and walking. METHODS: We undertook a secondary analysis of data from the Western Australian state government's health surveillance survey for those aged 65--84 years and living in the Perth metropolitan region from 2003--2009 (n = 2,918). Individual-level road network service areas were generated at 400 m and 800 m distances, and the presence or absence of six commercial destination types within the neighbourhood service areas identified (food retail, general retail, medical care services, financial services, general services, and social infrastructure). Adjusted logistic regression models examined access to and mix of commercial destination types within neighbourhoods for associations with self-reported walking behaviour. RESULTS: On average, the sample was aged 72.9 years (SD = 5.4), and was predominantly female (55.9%) and married (62.0%). Overall, 66.2% reported some weekly walking and 30.8% reported sufficient walking (>=150 min/week). Older adults with access to general services within 400 m (OR = 1.33, 95% CI = 1.07-1.66) and 800 m (OR = 1.20, 95% CI = 1.02-1.42), and social infrastructure within 800 m (OR = 1.19, 95% CI = 1.01-1.40) were more likely to engage in some weekly walking. Access to medical care services within 400 m (OR = 0.77, 95% CI = 0.63-0.93) and 800 m (OR = 0.83, 95% CI = 0.70-0.99) reduced the odds of sufficient walking. Access to food retail, general retail, financial services, and the mix of commercial destination types within the neighbourhood were all unrelated to walking. CONCLUSIONS: The types of neighbourhood commercial destinations that encourage older adults to walk appear to differ slightly from those reported for adult samples. Destinations that facilitate more social interaction, for example eating at a restaurant or church involvement, or provide opportunities for some incidental social contact, for example visiting the pharmacy or hairdresser, were the strongest predictors for walking among seniors in this study. This underscores the importance of planning neighbourhoods with proximate access to social infrastructure, and highlights the need to create residential environments that support activity across the life course.
Resumo:
We explored the impact of neighborhood walkability on young adults, early-middle adults, middle-aged adults, and older adults' walking across different neighborhood buffers. Participants completed the Western Australian Health and Wellbeing Surveillance System Survey (2003–2009) and were allocated a neighborhood walkability score at 200 m, 400 m, 800 m, and 1600 m around their home. We found little difference in strength of associations across neighborhood size buffers for all life stages. We conclude that neighborhood walkability supports more walking regardless of adult life stage and is relevant for small (e.g., 200 m) and larger (e.g., 1600 m) neighborhood buffers.
Resumo:
Purpose This work introduces the concept of very small field size. Output factor (OPF) measurements at these field sizes require extremely careful experimental methodology including the measurement of dosimetric field size at the same time as each OPF measurement. Two quantifiable scientific definitions of the threshold of very small field size are presented. Methods A practical definition was established by quantifying the effect that a 1 mm error in field size or detector position had on OPFs, and setting acceptable uncertainties on OPF at 1%. Alternatively, for a theoretical definition of very small field size, the OPFs were separated into additional factors to investigate the specific effects of lateral electronic disequilibrium, photon scatter in the phantom and source occlusion. The dominant effect was established and formed the basis of a theoretical definition of very small fields. Each factor was obtained using Monte Carlo simulations of a Varian iX linear accelerator for various square field sizes of side length from 4 mm to 100 mm, using a nominal photon energy of 6 MV. Results According to the practical definition established in this project, field sizes < 15 mm were considered to be very small for 6 MV beams for maximal field size uncertainties of 1 mm. If the acceptable uncertainty in the OPF was increased from 1.0 % to 2.0 %, or field size uncertainties are 0.5 mm, field sizes < 12 mm were considered to be very small. Lateral electronic disequilibrium in the phantom was the dominant cause of change in OPF at very small field sizes. Thus the theoretical definition of very small field size coincided to the field size at which lateral electronic disequilibrium clearly caused a greater change in OPF than any other effects. This was found to occur at field sizes < 12 mm. Source occlusion also caused a large change in OPF for field sizes < 8 mm. Based on the results of this study, field sizes < 12 mm were considered to be theoretically very small for 6 MV beams. Conclusions Extremely careful experimental methodology including the measurement of dosimetric field size at the same time as output factor measurement for each field size setting and also very precise detector alignment is required at field sizes at least < 12 mm and more conservatively < 15 mm for 6 MV beams. These recommendations should be applied in addition to all the usual considerations for small field dosimetry, including careful detector selection.