108 resultados para archives 2.0


Relevância:

90.00% 90.00%

Publicador:

Resumo:

The anhydrous salts of 1H-indole-3-ethanamine (tryptamine) with isomeric (2,4-dichlorophenoxy)acetic acid (2,4-D) and (3,5-dichlorophenoxy)acetic (3,5-D), C10H13N2+ (C8H5Cl2O3)-, [(I) and (II), respectively] have been determined and their one-dimensional hydrogen-bonded polymeric structures are described. In the crystal of (I),the aminium H-atoms are involved in three separate inter-species N-H...O hydrogen-bonding interactions, two with carboxyl O-atom acceptors and the third in an asymmetric three-centre bidentate carboxyl O,O' chelate [graph set R2/1(4)]. The indole H-atom forms an N-H...O~carboxyl~ hydrogen bond, extending the chain structure along the b axial direction. In (II), two of the three aminium H-atoms are also involved in N-H...O(carboxyl) hydrogen bonds similar to (I) but with the third, a three-centre asymmetric interaction with carboxyl and phenoxy O-atoms is found [graph set R2/1(5)]. The chain polymeric extension is also along b. There are no pi--pi ring interactions in either of the structures. The aminium side chain conformations differ significantly between the two structures, reflecting the conformational ambivalence of the tryptaminium cation, as found also in the benzoate salts.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The catalytic role of germanium (Ge) was investigated to improve the electrochemical performance of tin dioxide grown on graphene (SnO(2)/G) nanocomposites as an anode material of lithium ion batteries (LIBs). Germanium dioxide (GeO(20) and SnO(2) nanoparticles (<10 nm) were uniformly anchored on the graphene sheets via a simple single-step hydrothermal method. The synthesized SnO(2)(GeO(2))0.13/G nanocomposites can deliver a capacity of 1200 mA h g(-1) at a current density of 100 mA g(-1), which is much higher than the traditional theoretical specific capacity of such nanocomposites (∼ 702 mA h g(-1)). More importantly, the SnO(2)(GeO(2))0.13/G nanocomposites exhibited an improved rate, large current capability (885 mA h g(-1) at a discharge current of 2000 mA g(-1)) and excellent long cycling stability (almost 100% retention after 600 cycles). The enhanced electrochemical performance was attributed to the catalytic effect of Ge, which enabled the reversible reaction of metals (Sn and Ge) to metals oxide (SnO(2) and GeO(2)) during the charge/discharge processes. Our demonstrated approach towards nanocomposite catalyst engineering opens new avenues for next-generation high-performance rechargeable Li-ion batteries anode materials.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background: Clinicians frequently use their own judgement to assess patient’s hydration status although there is limited evidence for the diagnostic utility of any individual clinical symptom. Hence, the aim of this study was to compare the diagnostic accuracy of clinically assessed dehydration in older hospital patients (using multiple symptoms), versus dehydration measured using serum-calculated osmolality (CO) as the reference standard. Method: Participants were 44 hospital patients aged ≥ 60 years. Dehydration was assessed clinically and pathologically (CO) within 24 hours of admission and at study exit. Indicators of diagnostic accuracy were calculated. Results: Clinicians identified 27% of patients as dehydrated at admission, and 19% at exit, compared to 19% and 16% using CO. Agreement between the measures was fair at admission and poor at exit. Clinical assessment showed poor sensitivity for predicting dehydration with reasonable specificity. Conclusions: Compared to the use of CO, clinical assessment of dehydration in older patients was poor. Given that failure to identify dehydration in this population may have serious consequences, we recommend that clinicians do not rely upon their own assessments without also using the reference standard.