149 resultados para Replacement hip


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Metal ion release is common following total hip arthroplasty, yet postoperative levels have not been defined for most stems currently used in clinical practice. AIM: To assess metal ion release in the serum of patients with well functioning unilateral Exeter V40 primary total hip arthroplasties one year after surgery. METHODS: Whole blood chromium and serum cobalt levels were measured in 20 patients following primary total hip arthroplasty with the Exeter V40 stem and a variety of acetabular components one year after surgery. RESULTS: Whole blood chromium levels were within the normal range (10-100 nmol/L), with a single mild elevation of serum cobalt (normal < 20 nmol/L). CONCLUSION: In well functioning primary unilateral total hip arthroplasty using the Exeter V40 stem with a variety of acetabular components one year post surgery, whole blood chromium levels are normal and serum cobalt elevations are rare and mild.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction This study aimed to examine the geometric and dosimetric results when radiotherapy treatment plans are designed for prostate cancer patients with hip prostheses. Methods Ten EBRT treatment plans for localised prostate cancer, in the presence of hip prostheses, were analysed and compared with a reference set of 196 treatment plans for localised prostate cancer in patients without prostheses. Crowe et al.’s TADA code [1] was used to extract treatment plan parameters and evaluate doses to target volumes and critical structures against recommended goals [2] and constraints [3, 4]. Results The need to avoid transmitting the radiation beam through the hip prostheses limited the range of gantry angles available for use in both the rotational (VMAT) and the non-rotational (3DCRT and IMRT) radiotherapy treatments. This geometric limitation (exemplified in the VMAT data shown in Fig. 1) reduced the overall quality of the treatment plans for patients with prostheses compared to the reference plans. All plans with prostheses failed the PTV dose homogeneity requirement [2], whereas only 4 % of the plans without prostheses failed this test. Several treatment plans for patients with hip prostheses also failed the QUANTEC requirements that less than 50 % of the rectum receive 50 Gy and less than 35 % of the rectum receive 60 Gy to keep the grade 3 toxicity rate below 10 % [3], or the Hansen and Roach requirement that less than 25 % of the bladder receive 75 Gy [4]. Discussion and conclusions The results of this study exemplify the difficulty of designing prostate radiotherapy treatment plans, where beams provide adequate doses to targeted tissues while avoiding nearby organs at risk, when the presence of hip prostheses limits the available treatment geometries. This work provides qualitative evidence of the compromised dose distributions that can result, in such cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The LCC15-MB cell line was established from a femoral bone metastasis that arose in a 29-year-old woman initially diagnosed with an infiltrating ductal mammary adenocarcinoma. The tumor had a relatively high (8%) S-phase fraction and 1/23 positive lymph nodes (LN). Both the primary tumor and LN metastasis were positive for estrogen receptor (ER) and progesterone receptor (PgR), but lacked erbB2 expression. Approximately one year later, the patient presented with a 0.8 cm comedo-type intraductal mammary adenocarcinoma in the left breast that was negative for ER and PgR, but positive for erbB2. Thirty-five months after the initial diagnosis she was treated for acute skeletal metastasis, and stabilized with a hip replacement. At this time, tumor cells were removed from surplus involved bone, inoculated into cell culture, and developed into the LCC15-MB cell line. The bone metastasis was a poorly differentiated adenocarcinoma lacking ER, PgR, and erbB2, characteristics shared by the LCC15-MB cells, although ER can be re-expressed by treatment of the LCC15-MB cells for 5 days with 75 μM 5-aza-2'-deoxycytidine. The LCC15-MB cell line is tumorigenic when implanted subcutaneously in NCr nu/nu mice and produces long-bone metastases after intracardiac injection. Although the bone metastasis from which the LCC15-MB cell line was derived lacked vimentin (VIM) expression, the original primary tumor and lymph node metastasis were strongly VIM positive, as are LCC15-MB cells in vitro and in nude mice. The karyotype and isozyme profiles of LCC15-MB cells are consistent with its origin from a human female, with most chromosome counts in the hypertriploid range. Thirty-two marker chromosomes are present. These cells provide an in vitro/in vivo model in which to study the inter-relationships between ER, VIM, and bone metastasis in human breast cancer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Periprosthetic joint infection (PJI) after THA is a major complication with an incidence of 1-3%. We report our experiences with a technique using a custom-made articulating spacer (CUMARS) at the first of two-stage treatment for PJI. This technique uses widely available all-polyethylene acetabular components and the Exeter Universal stem, fixed using antibiotic loaded acrylic cement. Seventy-six hips were treated for PJI using this technique. Performed as the first of a two-stage procedure, good functional results were commonly seen, leading to postponing second stage indefinitely with retention of the CUMARS prosthesis in 34 patients. The CUMARS technique presents an alternative to conventional spacers, using readily available components that are well tolerated, allowing weight bearing and mobility, and achieving comparable eradication rates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The validity of fatigue protocols involving multi-joint movements, such as stepping, has yet to be clearly defined. Although surface electromyography can monitor the fatigue state of individual muscles, the effects of joint angle and velocity variation on signal parameters are well established. Therefore, the aims of this study were to i) describe sagittal hip and knee kinematics during repetitive stepping ii) identify periods of high inter-trial variability and iii) determine within-test reliability of hip and knee kinematic profiles. A group of healthy men (N = 15) ascended and descended from a knee-high platform wearing a weighted vest (10%BW) for 50 consecutive trials. The hip and knee underwent rapid flexion and extension during step ascent and descent. Variability of hip and knee velocity peaked between 20-40% of the ascent phase and 80-100% of the descent. Significant (p<0.05) reductions in joint range of motion and peak velocity during step ascent were observed, while peak flexion velocity increased during descent. Healthy individuals use complex hip and knee motion to negotiate a knee-high step with kinematic patterns varying across multiple repetitions. These findings have important implications for future studies intending to use repetitive stepping as a fatigue model for the knee extensors and flexors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Submission in response to government options paper regarding arrangements for regulation of charities following abolition of the Australian Charities and Not-for-profits Commission.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The primary motivation for the vehicle replacement schemes that were implemented in many countries was to encourage the purchase of new cars. The basic assumption of these schemes was that these acquisitions would benefit both the economy and the environment as older and less fuel-efficient cars were scrapped and replaced with more fuel-efficient models. In this article, we present a new environmental impact assessment method for assessing the effectiveness of scrappage schemes for reducing CO2 emissions taking into account the rebound effect, driving behavior for older versus new cars and entire lifecycle emissions for during the manufacturing processes of new cars. The assessment of the Japanese scrappage scheme shows that CO2 emissions would only decrease if users of the scheme retained their new gasoline passenger vehicles for at least 4.7 years. When vehicle replacements were restricted to hybrid cars, the reduction in CO2 achieved by the scheme would be 6-8.5 times higher than the emissions resulting from a scheme involving standard, gasoline passenger vehicles. Cost-benefit analysis, based on the emission reduction potential, showed that the scheme was very costly. Sensitivity analysis showed that the Japanese government failed to determine the optimum, or target, car age for scrapping old cars in the scheme. Specifically, scrapping cars aged 13 years and over did not maximize the environmental benefits of the scheme. Consequently, modifying this policy to include a reduction in new car subsidies, focused funding for fuel-efficient cars, and modifying the target car age, would increase environmental benefits. © 2013 Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: In an attempt to reduce stress shielding in the proximal femur multiple new shorter stem design have become available. We investigated the load to fracture of a new polished tapered cemented short stem in comparison to the conventional polished tapered Exeter stem. Method: A total of forty-two stems, twenty-one short stems and twenty-one conventional stems both with three different offsets were cemented in a composite sawbone model and loaded to fracture. Results: study showed that femurs will break at a significantly lower load to failure with a shorter compared to conventional length Exeter stem. Conclusion: This Both standard and short stem design are safe to use as the torque to failure is 7–10 times as much as the torques seen in activities of daily living.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study compared proximal femoral morphology in patients living in soft and hard water regions. The proximal femoral morphology of two groups of 70 patients living in hard and soft water regions with a mean age of 72.3 (range 50 to 87 years) were measured using an antero-posterior radiograph of the non-operated hip with magnification adjusted. The medullary canal diameter at the level of the lesser trochanter (LT) was significantly wider in patients living in the hard water region (mean width 1.9 mm wider; p= 0.003). No statistical significant difference was found in the medullary canal width at 10 cm below the level of LT, Dorr index, or Canal Bone Ratio (CBR). In conclusion, the proximal femoral morphology does differ in patients living in soft and hard water areas. These results may have an important clinical bearing in patients undergoing total hip replacement surgery. Further research is needed to determine whether implant survivorship is affected in patients living in hard and soft water regions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Clinical guidelines for the treatment of chronic low back pain suggest the use of supervised exercise. Motor control (MC) based exercise is widely used within clinical practice but its efficacy is equivalent to general exercise therapy. MC exercise targets the trunk musculature. Considering the mechanical links between the hip, pelvis, and lumbar spine, surprisingly little focus has been on investigating the contribution of the hip musculature to lumbopelvic support. The purpose of this study is to compare the efficacy of two exercise programs for the treatment of non-specific low back pain (NSLBP). Methods Eighty individuals aged 18-65 years of age were randomized into two groups to participate in this trial. The primary outcome measures included self-reported pain intensity (0-100mm VAS) and percent disability (Oswestry Disability Index V2). Bilateral measures of hip strength (N/kg) and two dimensional frontal plane mechanics (º) were the secondary outcomes. Outcomes were measured at baseline and following a six-week home based exercise program including weekly sessions of real-time ultrasound imaging. Results Within group comparisons revealed clinically meaningful reductions in pain for both groups. The MC exercise only (N= 40, xˉ =-20.9mm, 95%CI -25.7, -16.1) and the combined MC and hip exercise (N= 40, xˉ = -24.9mm, 95%CI -30.8, -19.0). There was no statistical difference in the change of pain (xˉ =-4.0mm, t= -1.07, p=0.29, 95%CI -11.5, 3.5) or disability (xˉ =-0.3%, t=-0.19, p=0.85, 95%CI -11.5, 3.5) between groups. Conclusion Both exercise programs had similar and positive effects on NSLBP which support the use of the home based exercise programs with weekly supervised visits. However, the addition of specific hip strengthening exercises to a MC based exercise program did not result in significantly greater reductions in pain or disability. Trial Registration NCTO1567566 Funding: Worker’s Compensation Board Alberta Research Grant.