122 resultados para ROTATIONAL RELAXATION


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background There is increasing interest in using complementary and alternative treatments to manage behavioural and psychological symptoms of dementia such as agitation, aggression and depressed mood. Objective To compare the effect of foot massage (intervention) and quiet presence (control) on agitation and mood in people with dementia. Design A randomised controlled trial using a within-subjects, crossover design. Settings Five long-term care facilities in Brisbane, Australia. The primary outcome was the Cohen-Mansfield Agitation Inventory (CMAI) and the secondary outcome was the Observed Emotion Rating Scale (OERS). The screening and data collection research assistants, families, and care staff were blinded to participant allocation. Participants Participants of the study were 55 long-term care residents aged 74–103 years (mean age 86.5), with moderate to severe dementia and a history of agitated behaviour according to the Pittsburgh Agitation Scale. A computer-program randomised participants to 10-min foot massage (intervention) or quiet presence (control), every weekday for 3 weeks. Results A carry-over effect was identified in the data, and so the data was treated as a parallel groups RCT. The mean total CMAI increased in both groups (reflecting an increase in agitation) with this increase greater in the quiet presence group than the foot massage group (p=0.03). There was a trend towards a difference on OERS General Alertness, with a positive change in alertness for participants in the foot massage group (indicating reduced alertness) and a negative change for participants in the quiet presence group (indicating increased alertness) (F(1,51)=3.88, p=0.05, partial ή2=0.07). Conclusions The findings highlight the need for further research on the specific conditions under which massage might promote relaxation and improve mood for people with dementia. The unfamiliar research assistants and variations in usual activity may have contributed to the increase in agitation and this needs further research.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background There is increasing interest in using complementary and alternative treatments to manage behavioural and psychological symptoms of dementia such as agitation, aggression and depressed mood. Objective To compare the effect of foot massage (intervention) and quiet presence (control) on agitation and mood in people with dementia. Design A randomised controlled trial using a within-subjects, crossover design. Settings Five long-term care facilities in Brisbane, Australia. The primary outcome was the Cohen-Mansfield Agitation Inventory (CMAI) and the secondary outcome was the Observed Emotion Rating Scale (OERS). The screening and data collection research assistants, families, and care staff were blinded to participant allocation. Participants Participants of the study were 55 long-term care residents aged 74–103 years (mean age 86.5), with moderate to severe dementia and a history of agitated behaviour according to the Pittsburgh Agitation Scale. A computer-program randomised participants to 10-min foot massage (intervention) or quiet presence (control), every weekday for 3 weeks. Results A carry-over effect was identified in the data, and so the data was treated as a parallel groups RCT. The mean total CMAI increased in both groups (reflecting an increase in agitation) with this increase greater in the quiet presence group than the foot massage group (p=0.03). There was a trend towards a difference on OERS General Alertness, with a positive change in alertness for participants in the foot massage group (indicating reduced alertness) and a negative change for participants in the quiet presence group (indicating increased alertness) (F(1,51)=3.88, p=0.05, partial ή2=0.07). Conclusions The findings highlight the need for further research on the specific conditions under which massage might promote relaxation and improve mood for people with dementia. The unfamiliar research assistants and variations in usual activity may have contributed to the increase in agitation and this needs further research.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim To explore the effects of a dementia-specific, aquatic exercise intervention on behavioural and psychological symptoms in people with dementia (BPSD). Method Residents from two aged care facilities in Queensland, Australia, received a 12-week intervention consisting of aquatic exercises for strength, agility, flexibility, balance and relaxation. The Psychological Well-Being in Cognitively Impaired Persons Scale (PW-BCIP) and the Revised Memory and Behaviour Problems Checklist (RMBPC) were completed by registered nurses at baseline, week 6, week 9 and post intervention. Results Ten women and one man (median age = 88.4 years, interquartile range = 12.3) participated. Statistically significant declines in the RMBPC and PW-BCIP were observed over the study period. Conclusion Preliminary evidence suggests that a dementia-specific, aquatic exercise intervention reduces BPSD and improves psychological well-being in people with moderate to severe dementia. With further testing, this innovative intervention may prove effective in addressing some of the most challenging aspects of dementia care.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This pilot project aimed to try something different - rekindle positive memories of swimming in people with dementia who enjoyed swimming throughout their lives, and involve them in active swimming again using a swimming club intervention. Club members were recruited from two residential aged care facilities in Queensland, Australia (n=25 recruited, n=18 commenced, n=11 (median age=88.4, IQR=12.3; 1 male) completed the intervention). The 12 week program consisted of two, 45 minute sessions per week held at a municipal pool, using a trained instructor and assistants. Measures, taken at baseline, Week 6, Week 9 and post intervention included psychosocial and physical assessments such as the Revised Memory and Behavior Problems Checklist, Psychological Well-Being in Cognitively Impaired Persons, Seniors Physical Performance Battery and bioelectric impedance analysis. Stakeholder focus groups determined the barriers and facilitators for the club. Three outcomes have been achieved: 1) the development of a dementia specific, evidence-based, aquatic exercise program. This valuable resource will ensure that the benefits will be maximized with tailored exercises for strength, agility, flexibility, balance, relaxation and stress reduction, 2) improved quality of life for members, with statistically significant improvements in psychological wellbeing (χ2 =8.66, p<0.05), BPSD expression (χ2=16.91, p=0.001) and staff distress (χ2=16.86, p=0.001) and 3) an informative website with instructional video clips and a manual to assist others in implementing and maintaining a Watermemories Swimming Club. This pilot project has provided strong evidence that aquatic exercise can produce positive physical, psychosocial and behavioral outcomes for people with dementia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this study, the mixed convection heat transfer and fluid flow behaviors in a lid-driven square cavity filled with high Prandtl number fluid (Pr = 5400, ν = 1.2×10-4 m2/s) at low Reynolds number is studied using thermal Lattice Boltzmann method (TLBM) where ν is the viscosity of the fluid. The LBM has built up on the D2Q9 model and the single relaxation time method called the Lattice-BGK (Bhatnagar-Gross-Krook) model. The effects of the variations of non dimensional mixed convection parameter called Richardson number(Ri) with and without heat generating source on the thermal and flow behavior of the fluid inside the cavity are investigated. The results are presented as velocity and temperature profiles as well as stream function and temperature contours for Ri ranging from 0.1 to 5.0 with other controlling parameters that present in this study. It is found that LBM has good potential to simulate mixed convection heat transfer and fluid flow problem. Finally the simulation results have been compared with the previous numerical and experimental results and it is found to be in good agreement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Composites with carbon nanotubes are becoming increasingly used in energy storage and electronic devices, due to incorporated excellent properties from carbon nanotubes and polymers. Although their properties make them more attractive than conventional smart materials, their electrical properties are found to be temperature-dependent which is important to consider for the design of devices. To study the effects of temperature in electrically conductive multi-wall carbon nanotube/epoxy composites, thin films were prepared and the effect of temperature on the resistivity, thermal properties and Raman spectral characteristics of the composite films was evaluated. Resistivity-temperature profiles showed three distinct regions in as-cured samples and only two regions in samples whose thermal histories had been erased. In the vicinity of the glass transition temperature, the as-cured composites exhibited pronounced resistivity and enthalpic relaxation peaks, which both disappeared after erasing the composites’ thermal histories by temperature cycling. Combined DSC, Raman spectroscopy, and resistivity-temperature analyses indicated that this phenomenon can be attributed to the physical aging of the epoxy matrix and that, in the region of the observed thermal history-dependent resistivity peaks, structural rearrangement of the conductive carbon nanotube network occurs through a volume expansion/relaxation process. These results have led to an overall greater understanding of the temperature-dependent behaviour of conductive carbon nanotube/epoxy composites, including the positive temperature coefficient effect.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of dual growing rods is a fusionless surgical approach to the treatment of early onset scoliosis (EOS) which aims to harness potential growth in order to correct spinal deformity. This study compared through in-vitro experiments the biomechanical response of two different rod designs under axial rotation loading. The study showed that a new design of telescoping growing rod preserved the rotational flexibility of the spine in comparison with rigid rods indicating them to be a more physiological way to improve the spinal deformity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Various studies have been conducted to investigate the effects of impact loading on cartilage damage and chondrocyte death. These have shown that the rate and magnitude of the applied strain significantly influence chondrocyte death, and that cell death occurred mostly in the superficial zone of cartilage suggesting the need to further understand the fundamental mechanisms underlying the chondrocytes death induced at certain levels of strain-rate. To date there is no comprehensive study providing insight on this phenomenon. The aim of this study is to examine the strain-rate dependent behavior of a single chondrocyte using a computational approach based on Finite Element Method (FEM). An FEM model was developed using various mechanical models, which were Standard Neo-Hookean Solid (SnHS), porohyperelastic (PHE) and poroviscohyperelastic (PVHE) to simulate Atomic Force Microscopy (AFM) experiments of chondrocyte. The PVHE showed, it can capture both relaxation and loading rate dependent behaviors of chondrocytes, accurately compared to other models.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the title compound, [K2(C7H3Cl2O2)2(H2O)]n, the potassium salt of 2,4-dichlorobenzoic acid, the repeating unit in the polymeric structure consists of two identical irregular KO6Cl complex units related by twofold rotational symmetry, linked by a bridging water molecule lying on the twofold axis. The coordination polyhedron about each K+ comprises a carboxyl O-atom and a Cl-atom donor from a bidentate chelate ligand interaction, four O-atom donors from a doubly bridging bidentate carboxyl (O,O')-chelate interaction and the water molecule. A two-dimensional layered coordination polymer structure lying parallel to (100) is generated through a series of conjoined cyclic bridges between K centres and is stabilized by water O-H...O(carboxyl) hydrogen-bonding interactions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction This study aimed to examine the geometric and dosimetric results when radiotherapy treatment plans are designed for prostate cancer patients with hip prostheses. Methods Ten EBRT treatment plans for localised prostate cancer, in the presence of hip prostheses, were analysed and compared with a reference set of 196 treatment plans for localised prostate cancer in patients without prostheses. Crowe et al.’s TADA code [1] was used to extract treatment plan parameters and evaluate doses to target volumes and critical structures against recommended goals [2] and constraints [3, 4]. Results The need to avoid transmitting the radiation beam through the hip prostheses limited the range of gantry angles available for use in both the rotational (VMAT) and the non-rotational (3DCRT and IMRT) radiotherapy treatments. This geometric limitation (exemplified in the VMAT data shown in Fig. 1) reduced the overall quality of the treatment plans for patients with prostheses compared to the reference plans. All plans with prostheses failed the PTV dose homogeneity requirement [2], whereas only 4 % of the plans without prostheses failed this test. Several treatment plans for patients with hip prostheses also failed the QUANTEC requirements that less than 50 % of the rectum receive 50 Gy and less than 35 % of the rectum receive 60 Gy to keep the grade 3 toxicity rate below 10 % [3], or the Hansen and Roach requirement that less than 25 % of the bladder receive 75 Gy [4]. Discussion and conclusions The results of this study exemplify the difficulty of designing prostate radiotherapy treatment plans, where beams provide adequate doses to targeted tissues while avoiding nearby organs at risk, when the presence of hip prostheses limits the available treatment geometries. This work provides qualitative evidence of the compromised dose distributions that can result, in such cases.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Portable water-filled barriers (PWFBs) are roadside appurtenances that prevent vehicles from penetrating into temporary construction zones on roadways. PWFBs are required to satisfy the strict regulations for vehicle re-direction in tests. However, many of the current PWFBs fail to re-direct the vehicle at high speeds due to the inability of the joints to provide appropriate stiffness. The joint mechanism hence plays a crucial role in the performance of a PWFB system at high speed impacts. This paper investigates the desired features of the joint mechanism in a PWFB system that can re-direct vehicles at high speeds, while limiting the lateral displacement to acceptable limits. A rectangular “wall” representative of a 30 m long barrier system was modeled and a novel method of joining adjacent road barriers was introduced through appropriate pin-joint connections. The impact response of the barrier “wall” and the vehicle was obtained and the results show that a rotational stiffness of 3000 kNm/rad at the joints seems to provide the desired features of the PWFB system to re-direct impacting vehicles and restrict the lateral deflection. These research findings will be useful to safety engineers and road barrier designers in developing a new generation of PWFBs for increased road safety.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The mechanical properties of microfilament networks are systematically summarized at different special scales in this paper. We have presented the mechanical models of single microfilaments and microfilament networks at microscale. By adopting a coarse-grained simulation strategy, the mechanical stability of microfilaments related cellular structures are analysed. Structural analysis is conducted to microfilament networks to understand the stress relaxation under compression. The nanoscale molecular mechanisms of the microfilaments deformation is also summarized from the viewpoint of molecular dynamics simulation. This paper provides the fundaments of multiscale modelling framework for the mechanical behaviours simulation of hierarchical microfilament networks.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The effect of radiation on natural convection of Newtonian fluid contained in an open cavity is investigated in this study. The governing partial differential equations are solved numerically using the Alternate Direct Implicit method together with the Successive Over Relaxation method. The study is focused on studying the flow pattern and the convective and radiative heat transfer rates are studied for different values of radiation parameters namely, the optical thickness of the fluid, scattering albedo, and the Planck number. It was found that in the optically thin limit, an increase in the optical thickness of the fluid raises the temperature and radiation heat transfer of the fluid. However, a further increase in the optical thickness decreases the radiative heat transfer rate due to increase in the energy level of the fluid, which ultimately reduces the total heat transfer rate within the fluid.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION Managing spinal deformities in young children is challenging, particularly early onset scoliosis (EOS). Surgical intervention is often required if EOS has been unresponsive to conservative treatment particularly with rapidly progressive curves. An emerging treatment option for EOS is fusionless scoliosis surgery. Similar to bracing, this surgical option potentially harnesses growth, motion and function of the spine along with correcting spinal deformity. Dual growing rods are one such fusionless treatment, which aims to modulate growth of the vertebrae. The aim of this study was to ascertain the extent to which semiconstrained growing rods (Medtronic, Sofamor, Danek, Memphis, TN) with a telescopic sleeve component, reduce rotational constraint on the spine compared with standard "constrained / rigid" rods and hence potentially provide a more physiological mechanical environment for the growing spine. METHODS Six 40-60kg English Large White porcine spines served as a model for the paediatric human spine. Each spine was dissected into a 7 level thoracolumbar multi-segment unit (MSU), removing all non-ligamentous soft tissues and leaving 3cm of ribs either side. Pure nondestructive axial rotation moments of ±4Nm at a constant rotation rate of 8deg.s-1 were applied to the mounted MSU spines using a biaxial Instron testing machine. Displacement of each vertebral level was captured using a 3D motion tracking system (Optotrak 3020, Northern Digital Inc, Waterloo, ON). Each spine was tested in an un-instrumented state first and then with appropriately sized semi-constrained growing rods and rigid rods in alternating sequence. The rods were secured by multi-axial pedicle screws (Medtronic CD Horizon) at levels 2 and 6 of the construct. The range of motion (ROM), neutral zone (NZ) size and stiffness (Nm.deg-1) were calculated from the Instron load-displacement data and intervertebral ROM was calculated through a MATLAB algorithm from Optotrak data. RESULTS Irrespective of the order of testing, rigid rods significantly reduced the total ROM compared with semi-constrained rods (p<0.05) with in a significantly stiffer spine for both left and right axial rotation (p<0.05). Analysing the intervertebral motion within the instrumented levels 2-6, rigid rods showed reduced ROM compared with semi-constrained growing rods and compared with un-instrumented motion segments. CONCLUSION Semi-constrained growing rods maintain similar stiffness in axial rotation to un-instrumented spines, while dual rigid rods significantly reduce axial rotation. Clinically the effect of semi-constrained growing rods as observed in this study is that they would be expected to allow growth via the telescopic rod components while maintaining the axial flexibility of the spine, which may reduce occurrence of the crankshaft phenomenon.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The dust-charge variation process is revisited, accounting for the background density variation associated with electron capture and release by the dust grains. It appears possible to maintain overall charge neutrality in the plasma without any external particle source or sink. It is shown that if the dust charge and density are sufficiently high, the effect of the background electron density variation on dust-charge relaxation is important. The equilibrium dust charge and its rate of variation are obtained for dusty plasmas subject to strong UV irradiation. The latter releases photoelectrons from the dust surface and can significantly affect the equilibrium dust charge, its variation rate, as well as the overall charge neutrality in the plasma.