770 resultados para Parents non gardiens


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: This study examined the quality of life (QOL), measured by the Functional Assessment of Cancer Therapy (FACT) questionnaire, among urban (n=277) and non-urban (n=323) breast cancer survivors and women from the general population (n=1140) in Queensland, Australia. ---------- Methods: Population-based samples of breast cancer survivors aged <75 years who were 12 months post-diagnosis and similarly-aged women from the general population were recruited between 2002 and 2007. ---------- Results: Age-adjusted QOL among urban and non-urban breast cancer survivors was similar, although QOL related to breast cancer concerns was the weakest domain and was lower among non-urban survivors than their urban counterparts (36.8 versus 40.4, P<0.01). Irrespective of residence, breast cancer survivors, on average, reported comparable scores on most QOL scales as their general population peers, although physical well-being was significantly lower among non-urban survivors (versus the general population, P<0.01). Overall, around 20%-33% of survivors experienced lower QOL than peers without the disease. The odds of reporting QOL below normative levels were increased more than two-fold for those who experienced complications following surgery, reported upper-body problems, had higher perceived stress levels and/or a poor perception of handling stress (P<0.01 for all). ---------- Conclusions: Results can be used to identify subgroups of women at risk of low QOL and to inform components of tailored recovery interventions to optimize QOL for these women following cancer treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recently, the numerical modelling and simulation for anomalous subdiffusion equation (ASDE), which is a type of fractional partial differential equation( FPDE) and has been found with widely applications in modern engineering and sciences, are attracting more and more attentions. The current dominant numerical method for modelling ASDE is Finite Difference Method (FDM), which is based on a pre-defined grid leading to inherited issues or shortcomings. This paper aims to develop an implicit meshless approach based on the radial basis functions (RBF) for numerical simulation of the non-linear ASDE. The discrete system of equations is obtained by using the meshless shape functions and the strong-forms. The stability and convergence of this meshless approach are then discussed and theoretically proven. Several numerical examples with different problem domains are used to validate and investigate accuracy and efficiency of the newly developed meshless formulation. The results obtained by the meshless formulations are also compared with those obtained by FDM in terms of their accuracy and efficiency. It is concluded that the present meshless formulation is very effective for the modeling and simulation of the ASDE. Therefore, the meshless technique should have good potential in development of a robust simulation tool for problems in engineering and science which are governed by the various types of fractional differential equations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Ambiguity remains about the effectiveness of wearing surgical face masks. The purpose of this study was to assess the impact on surgical site infections when non-scrubbed operating room staff did not wear surgical face masks. Design: Randomised controlled trial. Participants: Patients undergoing elective or emergency obstetric, gynecological, general, orthopaedic, breast or urological surgery in an Australian tertiary hospital. Intervention: 827 participants were enrolled and complete follow-up data was available for 811 (98.1%) patients. Operating room lists were randomly allocated to a ‘Mask roup’ (all non-scrubbed staff wore a mask) or ‘No Mask group’ (none of the non-scrubbed staff wore masks). Primary end point: Surgical site infection (identified using in-patient surveillance; post discharge follow-up and chart reviews). The patient was followed for up to six weeks. Results: Overall, 83 (10.2%) surgical site infections were recorded; 46/401 (11.5%) in the Masked group and 37/410 (9.0%) in the No Mask group; odds ratio (OR) 0.77 (95% confidence interval (CI) 0.49 to 1.21), p = 0.151. Independent risk factors for surgical site infection included: any pre-operative stay (adjusted odds ratio [aOR], 0.43 (95% CI, 0.20; 0.95), high BMI aOR, 0.38 (95% CI, 0.17; 0.87), and any previous surgical site infection aOR, 0.40 (95% CI, 0.17; 0.89). Conclusion: Surgical site infection rates did not increase when non-scrubbed operating room personnel did not wear a face mask.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Patent systems around the world are being pressed to recognise and protect challengingly new and exciting subject matter in order to keep pace with the rapid technological advancement of our age and the fact we are moving into the era of the ‘knowledge economy’. This rapid development and pressure to expand the bounds of what has traditionally been recognised as patentable subject matter has created uncertainty regarding what it is that the patent system is actually supposed to protect. Among other things, the patent system has had to contend with uncertainty surrounding claims to horticultural and agricultural methods, artificial living micro-organisms, methods of treating the human body, computer software and business methods. The contentious issue of the moment is one at whose heart lies the important distinction between what is a mere abstract idea and what is properly an invention deserving of the monopoly protection afforded by a patent. That question is whether purely intangible inventions, being methods that do not involve a physical aspect or effect or cause a physical transformation of matter, constitute patentable subject matter. This paper goes some way to addressing these uncertainties by considering how the Australian approach to the question can be informed by developments arising in the United States of America, and canvassing some of the possible lessons we in Australia might learn from the approaches taken thus far in the United States.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Support and education for parents faced with managing a child with atopic dermatitis is crucial to the success of current treatments. Interventions aiming to improve parent management of this condition are promising. Unfortunately, evaluation is hampered by lack of precise research tools to measure change. OBJECTIVES: To develop a suite of valid and reliable research instruments to appraise parents' self-efficacy for performing atopic dermatitis management tasks; outcome expectations of performing management tasks; and self-reported task performance in a community sample of parents of children with atopic dermatitis. METHODS: The Parents' Eczema Management Scale (PEMS) and the Parents' Outcome Expectations of Eczema Management Scale (POEEMS) were developed from an existing self-efficacy scale, the Parental Self-Efficacy with Eczema Care Index (PASECI). Each scale was presented in a single self-administered questionnaire, to measure self-efficacy, outcome expectations, and self-reported task performance related to managing child atopic dermatitis. Each was tested with a community sample of parents of children with atopic dermatitis, and psychometric evaluation of the scales' reliability and validity was conducted. SETTING AND PARTICIPANTS: A community-based convenience sample of 120 parents of children with atopic dermatitis completed the self-administered questionnaire. Participants were recruited through schools across Australia. RESULTS: Satisfactory internal consistency and test-retest reliability was demonstrated for all three scales. Construct validity was satisfactory, with positive relationships between self-efficacy for managing atopic dermatitis and general perceived self-efficacy; self-efficacy for managing atopic dermatitis and self-reported task performance; and self-efficacy for managing atopic dermatitis and outcome expectations. Factor analyses revealed two-factor structures for PEMS and PASECI alike, with both scales containing factors related to performing routine management tasks, and managing the child's symptoms and behaviour. Factor analysis was also applied to POEEMS resulting in a three-factor structure. Factors relating to independent management of atopic dermatitis by the parent, involving healthcare professionals in management, and involving the child in the management of atopic dermatitis were found. Parents' self-efficacy and outcome expectations had a significant influence on self-reported task performance. CONCLUSIONS: Findings suggest that PEMS and POEEMS are valid and reliable instruments worthy of further psychometric evaluation. Likewise, validity and reliability of PASECI was confirmed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During the past decade, a significant amount of research has been conducted internationally with the aim of developing, implementing, and verifying "advanced analysis" methods suitable for non-linear analysis and design of steel frame structures. Application of these methods permits comprehensive assessment of the actual failure modes and ultimate strengths of structural systems in practical design situations, without resort to simplified elastic methods of analysis and semi-empirical specification equations. Advanced analysis has the potential to extend the creativity of structural engineers and simplify the design process, while ensuring greater economy and more uniform safety with respect to the ultimate limit state. The application of advanced analysis methods has previously been restricted to steel frames comprising only members with compact cross-sections that are not subject to the effects of local buckling. This precluded the use of advanced analysis from the design of steel frames comprising a significant proportion of the most commonly used Australian sections, which are non-compact and subject to the effects of local buckling. This thesis contains a detailed description of research conducted over the past three years in an attempt to extend the scope of advanced analysis by developing methods that include the effects of local buckling in a non-linear analysis formulation, suitable for practical design of steel frames comprising non-compact sections. Two alternative concentrated plasticity formulations are presented in this thesis: the refined plastic hinge method and the pseudo plastic zone method. Both methods implicitly account for the effects of gradual cross-sectional yielding, longitudinal spread of plasticity, initial geometric imperfections, residual stresses, and local buckling. The accuracy and precision of the methods for the analysis of steel frames comprising non-compact sections has been established by comparison with a comprehensive range of analytical benchmark frame solutions. Both the refined plastic hinge and pseudo plastic zone methods are more accurate and precise than the conventional individual member design methods based on elastic analysis and specification equations. For example, the pseudo plastic zone method predicts the ultimate strength of the analytical benchmark frames with an average conservative error of less than one percent, and has an acceptable maximum unconservati_ve error of less than five percent. The pseudo plastic zone model can allow the design capacity to be increased by up to 30 percent for simple frames, mainly due to the consideration of inelastic redistribution. The benefits may be even more significant for complex frames with significant redundancy, which provides greater scope for inelastic redistribution. The analytical benchmark frame solutions were obtained using a distributed plasticity shell finite element model. A detailed description of this model and the results of all the 120 benchmark analyses are provided. The model explicitly accounts for the effects of gradual cross-sectional yielding, longitudinal spread of plasticity, initial geometric imperfections, residual stresses, and local buckling. Its accuracy was verified by comparison with a variety of analytical solutions and the results of three large-scale experimental tests of steel frames comprising non-compact sections. A description of the experimental method and test results is also provided.