113 resultados para Knee Kinetics


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Over the last two decades, Transcutaneous Bone-Anchored Prosthesis (TCBAP) has proven to be an effective alternative for prosthetic attachment for amputees, particularly for individuals unable to wear a socket. [1-17] However, the load transmitted through a typical TCBAP to the residual tibia and knee joint can be unbearable for transtibial amputees with knee arthritis. Aim A. To describe the surgical procedure combining TKR with TCBAP for the first time; and B. To present preliminary data on potential risks and benefits with assessment of clinical and functional outcomes at follow up Method We used a TCBAP connected to the tibial base plate of a Total Knee Replacement (TKR) prosthesis enabling the tibial residuum and the knee joint to act as weight sharing structures by transferring the load directly to the femur. We performed a standard hinged TKR connected to a custom made TCBAP at the first stage followed by creating a skin implant interface as a second stage. We retrospectively reviewed four cases of trans-tibial amputations presenting with knee joint arthritis. Patients were assessed clinically and functionally including standard measures of health-related quality of life, amputee mobility predictor tool, ambulation tests and actual activity level. Progress was monitored for 6-24 months. Results Clinical outcomes including adverse events show no major complications but one case of superficial infection. Functional outcomes improved for all participants as early as 6 months follow up. Discussion & Conclusion TKR and TCBAP were combined for the first time in this proof-of-concept case series. The preliminary outcomes indicated that this procedure is potentially a safe and effective alternative for this patient group despite the theoretical increase in risk of ascending infection through the skin-implant interface to the external environment. We suggest larger comparative series to further validate these results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background/Aim: To investigate the role of eccentric knee flexor strength, between-limb imbalance and biceps femoris long head (BFlh) fascicle length on the risk of a future hamstring strain injury (HSI). Methods: Elite soccer players (n=152) from eight different teams participated. Eccentric knee flexor strength during the Nordic hamstring exercise and BFlh fascicle length were assessed at the beginning of pre-season. The occurrences of a HSI following this were recorded by the team medical staff. Relative risk (RR) was determined for univariate data, and logistic regression was employed for multivariate data. Results: Twenty-seven new HSIs were reported. Eccentric knee flexor strength below 337N (RR = 4.4; 95% CI = 1.1 to 17.5) and BFlh fascicles shorter than 10.56cm (RR = 4.1; 95% CI=1.9 to 8.7) significantly increased the risk of a subsequent HSI. Multivariate logistic regression revealed significant effects when combinations of age, previous history of HSI, eccentric knee flexor strength and BFlh fascicle length were explored. From these analyses the likelihood of a future HSI in older athletes or those with a previous HSI history was reduced if high levels of eccentric knee flexor strength and longer BFlh fascicles were present. Conclusions: The presence of short BFlh fascicles and low levels of eccentric strength in elite soccer players increase the risk of a future HSI. The greater risk of a future HSI in older players or those with a previous HSI is reduced when they possess longer BFlh fascicles and high levels of eccentric strength.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and purpose — Osseointegrated implants are an alternative for prosthetic attachment in individuals with amputation who are unable to wear a socket. However, the load transmitted through the osseointegrated fixation to the residual tibia and knee joint can be unbearable for those with transtibial amputation and knee arthritis. We report on the feasibility of combining total knee replacement (TKR) with an osseointegrated implant for prosthetic attachment. Patients and methods — We retrospectively reviewed all 4 cases (aged 38–77 years) of transtibial amputations managed with osseointegration and TKR in 2012–2014. The below-the-knee prosthesis was connected to the tibial base plate of a TKR, enabling the tibial residuum and knee joint to act as weight-sharing structures. A 2-stage procedure involved connecting a standard hinged TKR to custom-made implants and creation of a skin-implant interface. Clinical outcomes were assessed at baseline and after 1–3 years of follow-up using standard measures of health-related quality of life, ambulation, and activity level including the questionnaire for transfemoral amputees (Q-TFA) and the 6-minute walk test. Results — There were no major complications, and there was 1 case of superficial infection. All patients showed improved clinical outcomes, with a Q-TFA improvement range of 29–52 and a 6-minute walk test improvement range of 37–84 meters. Interpretation — It is possible to combine TKR with osseointegrated implants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction and Objectives Joint moments and joint powers during gait are widely used to determine the effects of rehabilitation programs as well as prosthetic fitting. Following the definition of power (dot product of joint moment and joint angular velocity) it has been previously proposed to analyse the 3D angle between both vectors, αMw. Basically, joint power is maximised when both vectors are parallel and cancelled when both vectors are orthogonal. In other words, αMw < 60° reveals a propulsion configuration (more than 50% of the moment contribute to positive power) while αMw > 120° reveals a resistance configuration (more than 50% of the moment contribute to negative power). A stabilisation configuration (less than 50% of the moment contribute to power) corresponds to 60° < αMw < 120°. Previous studies demonstrated that hip joints of able-bodied adults (AB) are mainly in a stabilisation configuration (αMw about 90°) during the stance phase of gait. [1, 2] Individuals with transfemoral amputation (TFA) need to maximise joint power at the hip while controlling the prosthetic knee during stance. Therefore, we tested the hypothesis that TFAs should adopt a strategy that is different from a continuous stabilisation. The objective of this study was to compute joint power and αMw for TFA and to compare them with AB. Methods Three trials of walking at self-selected speed were analysed for 8 TFAs (7 males and 1 female, 46±10 years old, 1.78±0.08 m 82±13 kg) and 8 ABs (males, 25±3 years old, 1.75±0.04, m 67±6 kg). The joint moments are computed from a motion analysis system (Qualisys, Goteborg, Sweden) and a multi-axial transducer (JR3, Woodland, USA) mounted above the prosthetic knee for TFAs and from a motion analysis system (Motion Analysis, Santa Rosa, USA) and force plates (Bertec, Columbus, USA) for ABs. The TFAs were fitted with an OPRA (Integrum, AB, Gothengurg, Sweden) osseointegrated implant system and their prosthetic designs include pneumatic, hydraulic and microprocessor knees. Previous studies showed that the inverse dynamics computed from the multi-axial transducer is the proper method considering the absorption at the foot and resistance at the knee. Results The peak of positive power at loading response (H1) was earlier and lower for TFA compared to AB. Although the joint power is lower, the 3D angle between joint moment and joint angular velocity, αMw, reveals an obvious propulsion configuration (mean αMw about 20°) for TFA compared to a stabilisation configuration (mean αMw about 70°) for AB. The peaks of negative power at midstance (H2) and of positive power at preswing / initial swing (H3) occurred later, lower and longer for TFA compared to AB. Again, the joint powers are lower for TFA but, in this case, αMw is almost comparable (with a time lag), demonstrating a stabilisation (almost a resistance for TFA, mean αMw about 120°) and a propulsion configuration, respectively. The swing phase is not analysed in the present study. Conclusion The analysis of hip joint power may indicate that TFAs demonstrated less propulsion and resistance than ABs during the stance phase of gait. This is true from a quantitative point of view. On the contrary, the 3D angle between joint moment and joint angular velocity, αMw, reveals that TFAs have a remarkable propulsion strategy at loading response and almost a resistance strategy at midstance while ABs adopted a stabilisation strategy. The propulsion configuration, with αMw close to 0°, seems to aim at maximising the positive joint power. The configuration close to resistance, with αMw far from 180°, might aim at unlocking the prosthetic knee before swing while minimising the negative power. This analysis of both joint power and 3D angle between the joint moment and the joint angular velocity provides complementary insights into the gait strategies of TFA that can be used to support evidence-based rehabilitation and fitting of prosthetic components.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives Impaired muscle function is common in knee osteoarthritis (OA). Numerous biochemical molecules have been implicated in the development of OA; however, these have only been identified in the joint and serum. This study compared the expression of interleukin (IL-15) and Forkhead box protein-O1 (FoxO1) in muscle of patients with knee OA asymptomatic individuals, and examined whether IL-15 was also present in the joint and serum. Method Muscle and blood samples were collected from 19 patients with diagnosed knee OA and 10 age-matched asymptomatic individuals. Synovial fluid and muscle biopsies were collected from the OA group during knee replacement surgery. IL-15 and FoxO1were measured in the skeletal muscle. IL-15 abundance was also analysed in the serum of both groups and synovial fluid from the OA group. Knee extensor strength was measured and correlated with IL-15 and FoxO1 in the muscle. Results FoxO1 protein expression was higher (p=0.04), whereas IL-15 expression was lower (p=0.02) in the muscle of the OA group. Strength was also lower in the OA group, and was inversely correlated with FoxO1 expression. No correlation was found between IL-15 in the joint, muscle or serum. Conclusion Skeletal muscle, particularly the quadriceps, is affected in people with knee OA where elevated FoxO1 protein expression was associated with reduced muscle strength. While IL-15 protein expression in the muscle was lower in the knee OA group, no correlation was found between the expression of IL-15 protein in the muscle, joint and serum, which suggests that inflammation is regulated differently within these tissues.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Healthy transparent cornea depends upon the regulation of fluid, nutrient and oxygen transport through the tissue to sustain cell metabolism and other critical processes for normal functioning. This research considers the corneal geometry and investigates oxygen distribution using a two-dimensional Monod kinetic model, showing that previous studies make assumptions that lead to predictions of near-anoxic levels of oxygen tension in the limbal regions of the cornea. It also considers the comparison of experimental spatial and temporal data with the predictions of novel mathematical models with respect to distributed mitotic rates during corneal epithelial wound healing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In contrast to the well-known Charcot neuroarthropathy (CN) of the foot, CN of the knee is hardly recognized. In a literature search, we only found five articles on total knee arthroplasty for Charcot joints (1–5). We did not find a single article dealing with alternative treatment options or the general clinical course of this disease. We started our study

Relevância:

20.00% 20.00%

Publicador:

Resumo:

γ-Y 2Si 2O 7 is a promising candidate material both for hightemperature structural applications and as an environmental/thermal barrier coating material due to its unique properties such as high melting point, machinability, thermal stability, low linear thermal expansion coefficient (3.9×10 -6/K, 200°-1300°C), and low thermal conductivity (<3.0 W/ṁK above 300°C). The hot corrosion behavior of γ-Y 2Si 2O 7 in thin-film molten Na 2SO 4 at 850°-1000°C for 20 h in flowing air was investigated using a thermogravimetric analyzer (TGA) and a mass spectrometer (MS). γ-Y 2Si 2O 7 exhibited good resistance against Na 2SO 4 molten salt. The kinetic curves were well fitted by a paralinear equation: the linear part was caused by the evaporation of Na2SO4 and the parabolic part came from gas products evolved from the hotcorrosion reaction. A thin silica film formed under the corrosion scale was the key factor for retarding the hot corrosion. The apparent activation energy for the corrosion of γ-Y 2Si 2O 7 in Na 2SO 4 molten salt with flowing air was evaluated to be 255 kJ/mol.