306 resultados para Complications: headache, pneumocephalus


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In their paper Lindberg and Ludvigsen (2012) have correctly identified the lack of evidence-based nurse-sensitive indicators measuring the quality of haemodialysis nursing care. The authors suggest that the intradialytic ultrafiltration rate (UFR) (total fluid removed divided by the total time in a single dialysis treatment, measured in litres per hour) may be one such indicator. Importantly it is best practice to minimise high UFRs as they are associated with higher risk of cardiovascular events and vascular access complications (Curatola et al., 2011). However, this does not justify UFR to qualify as a nurse-sensitive indicator of quality in the haemodialysis context. The aim of this response is to voice our concerns over the proposal to use haemodialysis treatment UFR as a haemodialysis nurse-sensitive quality indicator...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There remains a substantial shortfall in treatment of severe skeletal injuries. The current gold standard of autologous bone grafting from the same patient, has many undesirable side effects associated such as donor site morbidity. Tissue engineering seeks to offer a solution to this problem. The primary requirements for tissue engineered scaffolds have already been well established, and many materials, such as polyesters, present themselves as potential candidates for bone defects; they have comparable structural features, but they often lack the required osteoconductivity to promote adequate bone regeneration. By combining these materials with biological growth factors; which promote the infiltration of cells into the scaffold as well as the differentiation into the specific cell and tissue type, it is possible to increase the formation of new bone. However cost and potential complications associated with growth factors means controlled release is an important consideration in the design of new bone tissue engineering strategies. This review will cover recent research in the area of encapsulation and release of growth factors within a variety of different polymeric scaffolds.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A PCR assay, using three primer pairs, was developed for the detection of Ureaplasma urealyticum, parvo biovar, mba types 1, 3, and 6, in cultured clinical specimens. The primer pairs were designed by using the polymorphic base positions within a 310- to 311-bp fragment of the 5* end and upstream control region of the mba gene. The specificity of the assay was confirmed with reference serovars 1, 3, 6, and 14 and by the amplified-fragment sizes (81 bp for mba 1, 262 bp for mba 3, and 193 bp for mba 6). A more sensitive nested PCR was also developed. This involved a first-step PCR, using the primers UMS-125 and UMA226, followed by the nested mba-type PCR described above. This nested PCR enabled the detection and typing of small numbers of U. urealyticum cells, including mixtures, directly in original clinical specimens. By using random amplified polymorphic DNA (RAPD) PCR with seven arbitrary primers, we were also able to differentiate the two biovars of U. urealyticum and to identify 13 RAPD-PCR subtypes. By applying these subtyping techniques to clinical samples collected from pregnant women, we established that (i) U. urealyticum is often a persistent colonizer of the lower genital tract from early midtrimester until the third trimester of pregnancy, (ii) mba type 6 was isolated significantly more often (P 5 0.048) from women who delivered preterm than from women who delivered at term, (iii) no particular ureaplasma subtype(s) was associated with placental infections and/or adverse pregnancy outcomes, and (iv) the ureaplasma subtypes most frequently isolated from women were the same subtypes most often isolated from infected placentas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The majority of cancer nurses have to manage intravascular devices (IVDs) on a daily basis, thus placing nurses in the strongest position to generate and use best available evidence to inform this area of practice and to ensure that patients are receiving the best care available. Our literature clearly reflects that cancer nurses are concerned about complications associated with IVDs (eg, extravasation,1 IVD-related bloodstream infection [IVD-BSI],2,3 and thrombosis4). Although enormous attention is given to this area, a number of nursing practices are not sufficiently based on empirical evidence.5,6 Nurses need to set goals and priorities for future research and investments. Priority areas for future research are suggested here for your consideration.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

‘Positive Stories’ is a digital storytelling initiative that took place in Adelaide in 2010–2011.1 This article describes participants’ experiences of creative self-representation and the thorny complications of mediating voice, particularly in situations where privacy and publicity are significant issues.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: To investigate the effect of Baby-Friendly Hospital Initiative (BFHI) accreditation and hospital care practices on breastfeeding rates at 1 and 4 months. METHODS: All women who birthed in Queensland, Australia, from February 1 to May 31, 2010, received a survey 4 months postpartum. Maternal, infant, and hospital characteristics; pregnancy and birth complications; and infant feeding outcomes were measured. RESULTS: Sample size was 6752 women. Breastfeeding initiation rates were high (96%) and similar in BFHI-accredited and nonaccredited hospitals. After adjustment for significant maternal, infant, clinical, and hospital variables, women who birthed in BFHI-accredited hospitals had significantly lower odds of breastfeeding at 1 month (adjusted odds ratio 0.72, 95% confidence interval 0.58–0.90) than those who birthed in non–BFHI-accredited hospitals. BFHI accreditation did not affect the odds of breastfeeding at 4 months or exclusive breastfeeding at 1 or 4 months. Four in-hospital practices (early skin-to-skin contact, attempted breastfeeding within the first hour, rooming-in, and no in-hospital supplementation) were experienced by 70% to 80% of mothers, with 50.3% experiencing all 4. Women who experienced all 4 hospital practices had higher odds of breastfeeding at 1 month (adjusted odds ratio 2.20, 95% confidence interval 1.78–2.71) and 4 months (adjusted odds ratio 2.93, 95% confidence interval 2.40–3.60) than women who experienced fewer than 4. CONCLUSIONS: When breastfeeding-initiation rates are high and evidence-based practices that support breastfeeding are common within the hospital environment, BFHI accreditation per se has little effect on both exclusive or any breastfeeding rates.C

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Shoulder joint is a complex integration of soft and hard tissues. It plays an important role in performing daily activities and can be considered as a perfect compromise between mobility and stability. However, shoulder is vulnerable to complications such as dislocations and osteoarthritis. Finite element (FE) models have been developed to understand shoulder injury mechanisms, implications of disease on shoulder complex and in assessing the quality of shoulder implants. Further, although few, Finite element shoulder models have also been utilized to answer important clinical questions such as the difference between a normal and osteoarthritic shoulder joint. However, due to the absence of experimental validation, it is questionable whether the constitutive models applied in these FE models are adequate to represent mechanical behaviors of shoulder elements (Cartilages, Ligaments, Muscles etc), therefore the confidence of using current models in answering clinically relevant question. The main objective of this review is to critically evaluate the existing FE shoulder models that have been used to investigate clinical problems. Due concern is given to check the adequacy of representative constitutive models of shoulder elements in drawing clinically relevant conclusion. Suggestions have been given to improve the existing shoulder models by inclusion of adequate constitutive models for shoulder elements to confidently answer clinically relevant questions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Extracorporeal circulation (ECC), the diversion of blood flow through a circuit located outside of the body, has been one of the major advances in modern medicine. Cardio-pulmonary bypass (CPB), renal dialysis, apheresis and extracorporeal membrane oxygenation (ECMO) are all different forms of ECC. Despite its major benefits, when blood comes into contact with foreign material, both the coagulation and inflammation cascades are activated simultaneously. Short periods of exposure to ECC e.g. CPB (�2 h duration), are known to be associated with haemolysis, coagulopathies, bleeding and inflammation which demand blood product support. Therefore, it is not unexpected that these complications would be exaggerated with prolonged periods of ECC such as in ECMO (days to weeks duration). The variability and complexities of the underlying pathologies of patients requiring ECC makes it difficult to study the cause and effect of these complications. To overcome this problem we developed an ovine (sheep) model of ECC. Method: Healthy female sheep (1–3 y.o.) weighing 40–50 kg were fasted overnight, anaesthetised, intubated and ventilated [1]. Half the group received smoke induced acute lung injury (S-ALI group) (n = 8) and the other half did not (healthy group) (n = 8). Sheep were subsequently cannulated (Medtronic Inc, Minneapolis, MN, USA) and veno-venous ECMO commenced using PLS ECMO circuit and Quadrox D oxygenator (Maquet Cardiopulmonary AG, Hechinger Straße, Germany). There was continuous physiological monitoring and blood was collected at specified time intervals for full blood counts, platelet function analysis (by Multiplate®), routine coagulation and assessment of clot formation and lysis (by ROTEM®). Preliminary results Full blood counts and routine coagulation results from normal healthy sheep were comparable to those of normal human adults. Within 15 min of initiating of ECMO, PT, PTT and EXTEM clot formation time increased, whilst EXTEM maximum clot firmness decreased in both cohorts. Discussion & Conclusions: Preliminary results of sheep from both 2 h ECMO cohorts showed that the anatomy, haematology and coagulation parameters of an adult sheep are comparable to that a human adult. Experiments are currently underway with healthy (n = 8) and S-ALI (n = 8) sheep on ECMO for 24 h. In addition to characterising how ECMO alters haematology and coagulation parameters, we hope that it will also define which blood components will be most effective to correct bleeding or clotting complications during ECMO support.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: normal ageing processes impact on oropharyngeal swallowing function placing older adults at risk of developing oropharyngeal dysphagia (OD). Anecdotal clinical experience has observed that older patients recovering from hip fracture surgery commonly develop OD post-operatively. Objective: to document the presence of OD following hip fracture surgery, and the factors associated with OD. Methods: one hundred and eighty-one patients with a mean age of 83 years (range: 65–103) admitted to a specialised orthogeriatric unit were assessed for OD post-surgery for hip fracture. Pre-admission, intra-operative and post-operative factors were examined to determine their relationship with the presence of OD. Results: OD was found to be present post-operatively in 34% (n = 61) of the current population. Multivariate logistic regression analyses revealed the presence of pre-existing neurological and respiratory medical co-morbidities, presence of post-operative delirium, age and living in a residential aged care facility prior to hospital admission to be associated with the post-operative OD. Conclusion: these results highlight that OD is present in a large number of the older hip fracture population. Early identification of OD has important implications for the provision of timely dysphagia management that may prevent secondary complications and potentially reduce the hospital length of stay.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: Comprehensive, accurate information about road crashes and related trauma is a prerequisite for identification and control of risk factors as well as for identifying faults within the broader road safety system. Quality data and appropriate crash investigation are critical in reducing the road toll that is rapidly growing in much of the developing world, including Pakistan. This qualitative research explored the involvement of social and cultural factors (in particular, fatalism) in risky road use in Pakistan. The findings highlight a significant issue, previously unreported in the road safety literature, namely, the link between fatalistic beliefs and inaccurate reporting of road crashes. Method: Thirty interviews (one-to one) were conducted by the first author with police officers, drivers, policy makers and religious orators in three Pakistani cities. Findings: Evidence emerged of a strong link between fatalism and the under-reporting of road crashes. In many cases, crashes and related road trauma appear to go unreported because a crash is considered to be one’s fate and, therefore, beyond personal control. Fate was also implicated in the practice of reconciliation between parties after a crash without police involvement and the seeking and granting of pardon for a road death. Conclusions: These issues represent additional factors that can contribute to under-reporting of crashes and associated trauma. Together, they highlight complications involved in establishing the true cost of road trauma in a country such as Pakistan and the difficulties faced when attempting to promote scientifically-based road safety information to counteract faith-based beliefs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background A large animal model is required for assessment of minimally invasive, tissue engineering based approaches to thoracic spine fusion, with relevance to deformity correction surgery for human adolescent idiopathic scoliosis. Here we develop a novel open mini–thoracotomy approach in an ovine model of thoracic interbody fusion which allows assessment of various fusion constructs, with a focus on novel, tissue engineering based interventions. Methods The open mini-thoracotomy surgical approach was developed through a series of mock surgeries, and then applied in a live sheep study. Customized scaffolds were manufactured to conform with intervertebral disc space clearances required of the study. Twelve male Merino sheep aged 4 to 6 years and weighing 35 – 45 kg underwent the abovementioned procedure and were divided into two groups of six sheep at survival timelines of 6 and 12 months. Each sheep underwent a 3-level discectomy (T6/7, T8/9 and T10/11) with randomly allocated implantation of a different graft substitute at each of the three levels; (i) polycaprolactone (PCL) based scaffold plus 0.54μg rhBMP-2, (ii) PCL-based scaffold alone or (iii) autograft. The sheep were closely monitored post- operatively for signs of pain (i.e. gait abnormalities/ teeth gnawing/ social isolation). Fusion assessments were conducted post-sacrifice using Computed Tomography and hard-tissue histology. All scientific work was undertaken in accordance with the study protocol has been approved by the Institute's committee on animal research. Results. All twelve sheep were successfully operated on and reached the allotted survival timelines, thereby demonstrating the feasibility of the surgical procedure and post-operative care. There were no significant complications and during the post-operative period the animals did not exhibit marked signs of distress according to the described assessment criteria. Computed Tomographic scanning demonstrated higher fusion grades in the rhBMP-2 plus PCL-based scaffold group in comparison to either PCL-based scaffold alone or autograft. These results were supported by histological evaluation of the respective groups. Conclusion. This novel open mini-thoracotomy surgical approach to the ovine thoracic spine represents a safe surgical method which can reproducibly form the platform for research into various spine tissue engineered constructs (TEC) and their fusion promoting properties.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Thoracoscopic anterior scoliosis instrumentation is a safe and viable surgical option for corrective fusion of progressive adolescent idiopathic scoliosis (AIS) and has been performed at our centre on 205 patients since 2000. However, there is a paucity of literature reporting on or examining optimum methods of analgesia following this type of surgery. A retrospective study was designed to present the authors’ technique for delivering intermittent local anaesthetic boluses via an intrapleural catheter following thoracoscopic scoliosis surgery; report the pain levels that may be expected and any adverse effects associated with the use of intrapleural analgesia, as part of a combined postoperative analgesia regime. Methods Records for 32 patients who underwent thoracoscopic anterior correction for AIS were reviewed. All patients received an intrapleural catheter inserted during surgery, in addition to patient-controlled opiate analgesia and oral analgesia. After surgery, patients received a bolus of 0.25% bupivacaine every four hours via the intrapleural catheter. Patient’s perceptions of their pain control was measured using the visual analogue pain scale scores which were recorded before and after local anaesthetic administration and the quantity and time of day that any other analgesia was taken, were also recorded. Results 28 female and four male patients (mean age 14.5 ± 1.5 years) had a total of 230 boluses of local anaesthetic administered in the 96 hour period following surgery. Pain scores significantly decreased following the administration of a bolus (p < 0.0001), with the mean pain score decreasing from 3.66 to 1.83. The quantity of opiates via patient-controlled analgesia after surgery decreased steadily between successive 24 hours intervals after an initial increase in the second 24 hour period when patients were mobilised. One intrapleural catheter required early removal due to leakage; there were no other associated complications with the intermittent intrapleural analgesia method. Conclusions Local anaesthetic administration via an intrapleural catheter is a safe and effective method of analgesia following thoracoscopic anterior scoliosis correction. Post-operative pain following anterior thoracic scoliosis surgery can be reduced to ‘mild’ levels by combined analgesia regimes. Keywords: Adolescent idiopathic scoliosis; Thoracoscopic anterior spinal fusion; Anterior fusion; Intrapleural analgesia; Endoscopic anterior surgery; Pain relief; Scoliosis surgery

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: To identify and appraise the literature concerning nurse-administered procedural sedation and analgesia in the cardiac catheter laboratory. Design and data sources: An integrative review method was chosen for this study. MEDLINE and CINAHL databases as well as The Cochrane Database of Systematic Reviews and the Joanna Briggs Institute were searched. Nineteen research articles and three clinical guidelines were identified. Results: The authors of each study reported nurse-administered sedation in the CCL is safe due to the low incidence of complications. However, a higher percentage of deeply sedated patients were reported to experience complications than moderately sedated patients. To confound this issue, one clinical guideline permits deep sedation without an anaesthetist present, while others recommend against it. All clinical guidelines recommend nurses are educated about sedation concepts. Other findings focus on pain and discomfort and the cost-savings of nurse-administered sedation, which are associated with forgoing anaesthetic services. Conclusions: Practice is varied due to limitations in the evidence and inconsistent clinical practice guidelines. Therefore, recommendations for research and practice have been made. Research topics include determining how and in which circumstances capnography can be used in the CCL, discerning the economic impact of sedation-related complications and developing a set of objectives for nursing education about sedation. For practice, if deep sedation is administered without an anaesthetist present, it is essential nurses are adequately trained and have access to vital equipment such as capnography to monitor ventilation because deeply sedated patients are more likely to experience complications related to sedation. These initiatives will go some way to ensuring patients receiving nurse-administered procedural sedation and analgesia for a procedure in the cardiac catheter laboratory are cared for using consistent, safe and evidence-based practices.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Procedural sedation and analgesia (PSA) administered by nurses in the cardiac catheterisation laboratory (CCL) is unlikely to yield serious complications. However, the safety of this practice is dependent on timely identification and treatment of depressed respiratory function. Aim: Describe respiratory monitoring in the CCL. Methods: Retrospective medical record audit of adult patients who underwent a procedure in the CCLs of one private hospital in Brisbane during May and June 2010. An electronic database was used to identify subjects and an audit tool ensured data collection was standardised. Results: Nurses administered PSA during 172/473 (37%) procedures including coronary angiographies, percutaneous coronary interventions, electrophysiology studies, radiofrequency ablations, cardiac pacemakers, implantable cardioverter defibrillators, temporary pacing leads and peripheral vascular interventions. Oxygen saturations were recorded during 160/172 (23%) procedures, respiration rate was recorded during 17/172 (10%) procedures, use of oxygen supplementation was recorded during 40/172 (23%) procedures and 13/172 (7.5%; 95% CI=3.59–11.41%) patients experienced oxygen desaturation. Conclusion: Although oxygen saturation was routinely documented, nurses did not regularly record respiration observations. It is likely that surgical draping and the requirement to minimise radiation exposure interfered with nurses’ ability to observe respiration. Capnography could overcome these barriers to respiration assessment as its accurate measurement of exhaled carbon dioxide coupled with the easily interpretable waveform output it produces, which displays a breath-by-breath account of ventilation, enables identification of respiratory depression in real-time. Results of this audit emphasise the need to ascertain the clinical benefits associated with using capnography to assess ventilation during PSA in the CCL.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cardiovascular diseases are a leading cause of death throughout the developed world. With the demand for donor hearts far exceeding the supply, a bridge-to-transplant or permanent solution is required. This is currently achieved with ventricular assist devices (VADs), which can be used to assist the left ventricle (LVAD), right ventricle (RVAD), or both ventricles simultaneously (BiVAD). Earlier generation VADs were large, volume-displacement devices designed for temporary support until a donor heart was found. The latest generation of VADs use rotary blood pump technology which improves device lifetime and the quality of life for end stage heart failure patients. VADs are connected to the heart and greater vessels of the patient through specially designed tubes called cannulae. The inflow cannulae, which supply blood to the VAD, are usually attached to the left atrium or ventricle for LVAD support, and the right atrium or ventricle for RVAD support. Few studies have characterized the haemodynamic difference between the two cannulation sites, particularly with respect to rotary RVAD support. Inflow cannulae are usually made of metal or a semi-rigid polymer to prevent collapse with negative pressures. However suction, and subsequent collapse, of the cannulated heart chamber can be a frequent occurrence, particularly with the relatively preload insensitive rotary blood pumps. Suction events may be associated with endocardial damage, pump flow stoppages and ventricular arrhythmias. While several VAD control strategies are under development, these usually rely on potentially inaccurate sensors or somewhat unreliable inferred data to estimate preload. Fixation of the inflow cannula is usually achieved through suturing the cannula, often via a felt sewing ring, to the cannulated chamber. This technique extends the time on cardiopulmonary bypass which is associated with several postoperative complications. The overall objective of this thesis was to improve the placement and design of rotary LVAD and RVAD inflow cannulae to achieve enhanced haemodynamic performance, reduced incidence of suction events, reduced levels of postoperative bleeding and a faster implantation procedure. Specific objectives were: * in-vitro evaluation of LVAD and RVAD inflow cannula placement, * design and in-vitro evaluation of a passive mechanism to reduce the potential for heart chamber suction, * design and in-vitro evaluation of a novel suture-less cannula fixation device. In order to complete in-vitro evaluation of VAD inflow cannulae, a mock circulation loop (MCL) was developed to accurately replicate the haemodynamics in the human systemic and pulmonary circulations. Validation of the MCL’s haemodynamic performance, including the form and magnitude of pressure, flow and volume traces was completed through comparisons of patient data and the literature. The MCL was capable of reproducing almost any healthy or pathological condition, and provided a useful tool to evaluate VAD cannulation and other cardiovascular devices. The MCL was used to evaluate inflow cannula placement for rotary VAD support. Left and right atrial and ventricular cannulation sites were evaluated under conditions of mild and severe heart failure. With a view to long term LVAD support in the severe left heart failure condition, left ventricular inflow cannulation was preferred due to improved LVAD efficiency and reduced potential for thrombus formation. In the mild left heart failure condition, left atrial cannulation was preferred to provide an improved platform for myocardial recovery. Similar trends were observed with RVAD support, however to a lesser degree due to a smaller difference in right atrial and ventricular pressures. A compliant inflow cannula to prevent suction events was then developed and evaluated in the MCL. As rotary LVAD or RVAD preload was reduced, suction events occurred in all instances with a rigid inflow cannula. Addition of the compliant segment eliminated suction events in all instances. This was due to passive restriction of the compliant segment as preload dropped, thus increasing the VAD circuit resistance and decreasing the VAD flow rate. Therefore, the compliant inflow cannula acted as a passive flow control / anti-suction system in LVAD and RVAD support. A novel suture-less inflow cannula fixation device was then developed to reduce implantation time and postoperative bleeding. The fixation device was evaluated for LVAD and RVAD support in cadaveric animal and human hearts attached to a MCL. LVAD inflow cannulation was achieved in under two minutes with the suture-less fixation device. No leakage through the suture-less fixation device – myocardial interface was noted. Continued development and in-vivo evaluation of this device may result in an improved inflow cannulation technique with the potential for off-bypass insertion. Continued development of this research, in particular the compliant inflow cannula and suture-less inflow cannulation device, will result in improved postoperative outcomes, life span and quality of life for end-stage heart failure patients.