116 resultados para Allele frequency data


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective. To elucidate the relative importance of the HLA-DR and HLA-DQ loci in conferring genetic predisposition to rheumatoid arthritis (RA). Methods. HLA-DRB1 and HLA-DQB1 alleles were typed in a set of 685 patients with RA using sequence-specific polymerase chain reaction. Allele and phenotype frequencies were compared with those in 2 large sets of historical, ethnically matched healthy controls, using the relative predispositional effect method. Results. Positive association was confirmed with the shared epitope positive HLA-DRB1 alleles associated with RA in Caucasians. A significant susceptibility effect was observed with HLA-DRB1*09, described in other ethnically diverse populations but not in Caucasians. A significant underrepresentation of the HLA-DRB1*0103 variant was noted among the RA cases, supporting the proposed protective role of the DERAA motif at residues 70-74 of the DRβ molecule. No HLA-DRB1 independent association of the HLA-DQB1 alleles, implicated in predisposing to RA, was evident. Conclusion. These data corroborate the shared epitope hypothesis of susceptibility to RA and provide strong evidence for the DRB1 locus as the primary RA susceptibility factor in the HLA region.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Online grocery shopping has enjoyed strong growth and it is predicted this channel will continue to grow exponentially in the coming years. While online shopping has attracted an abundance of research interest, examinations of online grocery shopping behaviour are only now emerging. Shopping online for groceries differs considerably from general online shopping due to the perishability and variability of the product, and frequency of the shopping activity. Two salient gaps underpin this research into online grocery shopping. This study responds to calls to investigate the online shoppers’ experience in the context of online purchasing frequency. Second, this study examines the mediating effect of perceived risk between trust and online repurchase intention of groceries. An online survey was employed to collect data from shoppers who were recruited from a multi-channel grocery e-retailer’s database. The online survey, comprising 16 reflective validated scale items, was sent to 555 frequent and infrequent online grocery shoppers. Results find that while customer satisfaction predicts trust for both infrequent and frequent online grocery shoppers, perceived risk fully mediates the effect of trust on repurchase intentions for infrequent online grocery shoppers. Furthermore path analysis reveals that the developed behavioural model is variant across both groups of shoppers. Theoretically, we provide a deeper understanding of the online customer experience, while gaining insight into two shopper segments identified as being important to grocery e-retailers. For managers, this study tests an online customer behavioural model with actual purchasing behaviour and identifies the continued presence of perceived risk in grocery e-retailing regardless of purchase frequency or experience.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

STUDY QUESTION Is there a contribution of the minor allele at the KRAS single nucleotide polymorphism (SNP) rs61764370 in the let-7 microRNA-binding site to endometriosis risk? SUMMARY ANSWER We found no evidence for association between endometriosis risk and rs61764370 or any other SNPs in KRAS. WHAT IS KNOWN ALREADY The rs61764370 SNP in the 3' untranslated region of the KRAS gene is predicted to disrupt a complementary binding site (LCS6) for the let-7 microRNA, and was recently reported to be at a high frequency (31%) in 132 women of varying ancestry with endometriosis compared with frequencies in a database of population controls (up to 7.6% depending on ancestry), suggesting a strong effect of this KRAS SNP in the aetiology of endometriosis. STUDY DESIGN, SIZE AND DURATION This was a case-control study with a total of 11 206 subjects. The study was performed between February 2012 and July 2012. PARTICIPANTS/MATERIALS, SETTINGAND METHODS We first investigated a possible association between common markers in KRAS and endometriosis risk from our genome-wide association (GWA) data in 3194 surgically confirmed endometriosis cases and 7060 controls of European ancestry. Although rs61764370 was not genotyped on the GWA arrays, five SNPs typed in the study were highly correlated with this variant. The rs61764370 and two SNPs highly correlated with rs61764370 were then genotyped in 933 endometriosis cases and 952 controls using the Sequenom MassARRAY platform. MAIN RESULTS AND THE ROLE OF CHANCE There was no evidence for an association between rs61764370 and endometriosis risk P = 0.411 and odds ratio = 1.10 (95% confidence intervals: 0.88-1.36). We also found no evidence for an association between the highly correlated SNP rs17387019 and endometriosis. Their minor allele frequencies in cases and controls were of 0.087-0.091 similar to the population frequency reported previously for this variant in controls. Analyses of endometriosis cases with revised American Fertility Society stage III/IV disease also showed no evidence for an association between these SNPs and endometriosis risk. LIMITATIONS AND REASONS FOR CAUTION The GWA and genotyped data sets were not independent since individuals and cases from some families overlap. Controls in our GWA study were not screened for endometriosis. WIDER IMPLICATIONS OF THE FINDINGS The key SNP, rs61764370, was genotyped in a subset of samples. Our results do not support the suggestion that carrying the minor allele at rs61764370 contributes to a significant number of endometriosis cases and rs61764370 is, therefore, unlikely to be a useful marker of endometriosis risk. STUDY FUNDING/COMPETING INTEREST(S) The research was funded by grants from the Australian National Health and Medical Research Council and Wellcome Trust. None of the authors has competing interests for the study.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Genotyping in DNA pools reduces the cost and the time required to complete large genotyping projects. The aim of the present study was to evaluate pooling as part of a strategy for fine mapping in regions of significant linkage. Thirty-nine single nucleotide polymorphisms (SNPs) were analyzed in two genomic DNA pools of 384 individuals each and results compared with data after typing all individuals used in the pools. There were no significant differences using data from either 2 or 8 heterozygous individuals to correct frequency estimates for unequal allelic amplification. After correction, the mean difference between estimates from the genomic pool and individual allele frequencies was .033. A major limitation of the use of DNA pools is the time and effort required to carefully adjust the concentration of each individual DNA sample before mixing aliquots. Pools were also constructed by combining DNA after Multiple Displacement Amplification (MDA). The MDA pools gave similar results to pools constructed after careful DNA quantitation (mean difference from individual genotyping .040) and MDA provides a rapid method to generate pools suitable for some applications. Pools provide a rapid and cost-effective screen to eliminate SNPs that are not polymorphic in a test population and can detect minor allele frequencies as low as 1% in the pooled samples. With current levels of accuracy, pooling is best suited to an initial screen in the SNP validation process that can provide high-throughput comparisons between cases and controls to prioritize SNPs for subsequent individual genotyping.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

As for other complex diseases, linkage analyses of schizophrenia (SZ) have produced evidence for numerous chromosomal regions, with inconsistent results reported across studies. The presence of locus heterogeneity appears likely and may reduce the power of linkage analyses if homogeneity is assumed. In addition, when multiple heterogeneous datasets are pooled, inter-sample variation in the proportion of linked families (alpha) may diminish the power of the pooled sample to detect susceptibility loci, in spite of the larger sample size obtained. We compare the significance of linkage findings obtained using allele-sharing LOD scores (LOD(exp))-which assume homogeneity-and heterogeneity LOD scores (HLOD) in European American and African American NIMH SZ families. We also pool these two samples and evaluate the relative power of the LOD(exp) and two different heterogeneity statistics. One of these (HLOD-P) estimates the heterogeneity parameter alpha only in aggregate data, while the second (HLOD-S) determines alpha separately for each sample. In separate and combined data, we show consistently improved performance of HLOD scores over LOD(exp). Notably, genome-wide significant evidence for linkage is obtained at chromosome 10p in the European American sample using a recessive HLOD score. When the two samples are combined, linkage at the 10p locus also achieves genome-wide significance under HLOD-S, but not HLOD-P. Using HLOD-S, improved evidence for linkage was also obtained for a previously reported region on chromosome 15q. In linkage analyses of complex disease, power may be maximised by routinely modelling locus heterogeneity within individual datasets, even when multiple datasets are combined to form larger samples.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background People admitted to intensive care units and those with chronic health care problems often require long-term vascular access. Central venous access devices (CVADs) are used for administering intravenous medications and blood sampling. CVADs are covered with a dressing and secured with an adhesive or adhesive tape to protect them from infection and reduce movement. Dressings are changed when they become soiled with blood or start to come away from the skin. Repeated removal and application of dressings can cause damage to the skin. The skin is an important barrier that protects the body against infection. Less frequent dressing changes may reduce skin damage, but it is unclear whether this practice affects the frequency of catheter-related infections. Objectives To assess the effect of the frequency of CVAD dressing changes on the incidence of catheter-related infections and other outcomes including pain and skin damage. Search methods In June 2015 we searched: The Cochrane Wounds Specialised Register; The Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library); Ovid MEDLINE; Ovid MEDLINE (In-Process & Other Non-Indexed Citations); Ovid EMBASE and EBSCO CINAHL. We also searched clinical trials registries for registered trials. There were no restrictions with respect to language, date of publication or study setting. Selection criteria All randomised controlled trials (RCTs) evaluating the effect of the frequency of CVAD dressing changes on the incidence of catheter-related infections on all patients in any healthcare setting. Data collection and analysis We used standard Cochrane review methodology. Two review authors independently assessed studies for inclusion, performed risk of bias assessment and data extraction. We undertook meta-analysis where appropriate or otherwise synthesised data descriptively when heterogeneous. Main results We included five RCTs (2277 participants) that compared different frequencies of CVAD dressing changes. The studies were all conducted in Europe and published between 1995 and 2009. Participants were recruited from the intensive care and cancer care departments of one children's and four adult hospitals. The studies used a variety of transparent dressings and compared a longer interval between dressing changes (5 to15 days; intervention) with a shorter interval between changes (2 to 5 days; control). In each study participants were followed up until the CVAD was removed or until discharge from ICU or hospital. - Confirmed catheter-related bloodstream infection (CRBSI) One trial randomised 995 people receiving central venous catheters to a longer or shorter interval between dressing changes and measured CRBSI. It is unclear whether there is a difference in the risk of CRBSI between people having long or short intervals between dressing changes (RR 1.42, 95% confidence interval (CI) 0.40 to 4.98) (low quality evidence). - Suspected catheter-related bloodstream infection Two trials randomised a total of 151 participants to longer or shorter dressing intervals and measured suspected CRBSI. It is unclear whether there is a difference in the risk of suspected CRBSI between people having long or short intervals between dressing changes (RR 0.70, 95% CI 0.23 to 2.10) (low quality evidence). - All cause mortality Three trials randomised a total of 896 participants to longer or shorter dressing intervals and measured all cause mortality. It is unclear whether there is a difference in the risk of death from any cause between people having long or short intervals between dressing changes (RR 1.06, 95% CI 0.90 to 1.25) (low quality evidence). - Catheter-site infection Two trials randomised a total of 371 participants to longer or shorter dressing intervals and measured catheter-site infection. It is unclear whether there is a difference in risk of catheter-site infection between people having long or short intervals between dressing changes (RR 1.07, 95% CI 0.71 to 1.63) (low quality evidence). - Skin damage One small trial (112 children) and three trials (1475 adults) measured skin damage. There was very low quality evidence for the effect of long intervals between dressing changes on skin damage compared with short intervals (children: RR of scoring ≥ 2 on the skin damage scale 0.33, 95% CI 0.16 to 0.68; data for adults not pooled). - Pain Two studies involving 193 participants measured pain. It is unclear if there is a difference between long and short interval dressing changes on pain during dressing removal (RR 0.80, 95% CI 0.46 to 1.38) (low quality evidence). Authors' conclusions The best available evidence is currently inconclusive regarding whether longer intervals between CVAD dressing changes are associated with more or less catheter-related infection, mortality or pain than shorter intervals.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Environmental changes have put great pressure on biological systems leading to the rapid decline of biodiversity. To monitor this change and protect biodiversity, animal vocalizations have been widely explored by the aid of deploying acoustic sensors in the field. Consequently, large volumes of acoustic data are collected. However, traditional manual methods that require ecologists to physically visit sites to collect biodiversity data are both costly and time consuming. Therefore it is essential to develop new semi-automated and automated methods to identify species in automated audio recordings. In this study, a novel feature extraction method based on wavelet packet decomposition is proposed for frog call classification. After syllable segmentation, the advertisement call of each frog syllable is represented by a spectral peak track, from which track duration, dominant frequency and oscillation rate are calculated. Then, a k-means clustering algorithm is applied to the dominant frequency, and the centroids of clustering results are used to generate the frequency scale for wavelet packet decomposition (WPD). Next, a new feature set named adaptive frequency scaled wavelet packet decomposition sub-band cepstral coefficients is extracted by performing WPD on the windowed frog calls. Furthermore, the statistics of all feature vectors over each windowed signal are calculated for producing the final feature set. Finally, two well-known classifiers, a k-nearest neighbour classifier and a support vector machine classifier, are used for classification. In our experiments, we use two different datasets from Queensland, Australia (18 frog species from commercial recordings and field recordings of 8 frog species from James Cook University recordings). The weighted classification accuracy with our proposed method is 99.5% and 97.4% for 18 frog species and 8 frog species respectively, which outperforms all other comparable methods.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The BeiDou system is the first global navigation satellite system in which all satellites transmit triple-frequency signals that can provide the positioning, navigation, and timing independently. A benefit of triple-frequency signals is that more useful combinations can be formed, including some extrawide-lane combinations whose ambiguities can generally be instantaneously fixed without distance restriction, although the narrow-lane ambiguity resolution (NL AR) still depends on the interreceiver distance or requires a long time to achieve. In this paper, we synthetically study decimeter and centimeter kinematic positioning using BeiDou triple-frequency signals. It starts with AR of two extrawide-lane signals based on the ionosphere-free or ionosphere-reduced geometry-free model. For decimeter positioning, one can immediately use two ambiguity-fixed extrawide-lane observations without pursuing NL AR. To achieve higher accuracy, NL AR is the necessary next step. Despite the fact that long-baseline NL AR is still challenging, some NL ambiguities can indeed be fixed with high reliability. Partial AR for NL signals is acceptable, because as long as some ambiguities for NL signals are fixed, positioning accuracy will be certainly improved.With accumulation of observations, more and more NL ambiguities are fixed and the positioning accuracy continues to improve. An efficient Kalman-filtering system is established to implement the whole process. The formulated system is flexible, since the additional constraints can be easily applied to enhance the model's strength. Numerical results from a set of real triple-frequency BeiDou data on a 50 km baseline show that decimeter positioning is achievable instantaneously.With only five data epochs, 84% of NL ambiguities can be fixed so that the real-time kinematic accuracies are 4.5, 2.5, and 16 cm for north, east, and height components (respectively), while with 10 data epochs more than 90% of NL ambiguities are fixed, and the rea- -time kinematic solutions are improved to centimeter level for all three coordinate components.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Carrier phase ambiguity resolution over long baselines is challenging in BDS data processing. This is partially due to the variations of the hardware biases in BDS code signals and its dependence on elevation angles. We present an assessment of satellite-induced code bias variations in BDS triple-frequency signals and the ambiguity resolutions procedures involving both geometry-free and geometry-based models. First, since the elevation of a GEO satellite remains unchanged, we propose to model the single-differenced fractional cycle bias with widespread ground stations. Second, the effects of code bias variations induced by GEO, IGSO and MEO satellites on ambiguity resolution of extra-wide-lane, wide-lane and narrow-lane combinations are analyzed. Third, together with the IGSO and MEO code bias variations models, the effects of code bias variations on ambiguity resolution are examined using 30-day data collected over the baselines ranging from 500 to 2600 km in 2014. The results suggest that although the effect of code bias variations on the extra-wide-lane integer solution is almost ignorable due to its long wavelength, the wide-lane integer solutions are rather sensitive to the code bias variations. Wide-lane ambiguity resolution success rates are evidently improved when code bias variations are corrected. However, the improvement of narrow-lane ambiguity resolution is not obvious since it is based on geometry-based model and there is only an indirect impact on the narrow-lane ambiguity solutions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The paper presents a geometry-free approach to assess the variation of covariance matrices of undifferenced triple frequency GNSS measurements and its impact on positioning solutions. Four independent geometryfree/ ionosphere-free (GFIF) models formed from original triple-frequency code and phase signals allow for effective computation of variance-covariance matrices using real data. Variance Component Estimation (VCE) algorithms are implemented to obtain the covariance matrices for three pseudorange and three carrier-phase signals epoch-by-epoch. Covariance results from the triple frequency Beidou System (BDS) and GPS data sets demonstrate that the estimated standard deviation varies in consistence with the amplitude of actual GFIF error time series. The single point positioning (SPP) results from BDS ionosphere-free measurements at four MGEX stations demonstrate an improvement of up to about 50% in Up direction relative to the results based on a mean square statistics. Additionally, a more extensive SPP analysis at 95 global MGEX stations based on GPS ionosphere-free measurements shows an average improvement of about 10% relative to the traditional results. This finding provides a preliminary confirmation that adequate consideration of the variation of covariance leads to the improvement of GNSS state solutions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A key challenge of wide area kinematic positioning is to overcome the effects of the varying hardware biases in code signals of the BeiDou system. Based on three geometryfree/ionosphere-free combinations, the elevation-dependent code biases are modelled for all BeiDou satellites. Results from the data sets of 30-day for 5 baselines of 533 to 2545 km demonstrate that the wide-lane (WL) integer-fixing success rates of 98% to 100% can be achieved within 25 min. Under the condition of HDOP of less than 2, the overall RMS statistics show that ionospheric-free WL single-epoch solutions achieve 24 to 50 cm in the horizontal direction. Smoothing processing over the moving window of 20 min reduces the RMS values by a factor of about 2. Considering distance-independent nature, the above results show the potential that reliable and high precision positioning services could be provided in a wide area based on a sparsely distributed ground network.