123 resultados para 1995_12070321 Optics-7


Relevância:

20.00% 20.00%

Publicador:

Resumo:

After more than twenty years of basic and applied research, the use of nanotechnology in the design and manufacture of nanoscale materials is rapidly increasing, particularly in commercial applications that span from electronics across renewable energy areas, and biomedical devices. Novel polymers are attracting significant attention for they promise to provide a low−cost high−performance alternative to existing materials. Furthermore, these polymers have the potential to overcome limitations imposed by currently available materials thus enabling the development of new technologies and applications that are currently beyond our reach. This work focuses on the development of a range of new low−cost environmentally−friendly polymer materials for applications in areas of organic (flexible) electronics, optics, and biomaterials. The choice of the monomer reflects the environmentally−conscious focus of this project. Terpinen−4−ol is a major constituent of Australian grown Melaleuca alternifolia (tea tree) oil, attributed with the oil's antimicrobial and anti−inflammatory properties. Plasma polymerisation was chosen as a deposition technique for it requires minimal use of harmful chemicals and produces no hazardous by−products. Polymer thin films were fabricated under varied process conditions to attain materials with distinct physico−chemical, optoelectrical, biological and degradation characteristics. The resultant materials, named polyterpenol, were extensively characterised using a number of well−accepted and novel techniques, and their fundamental properties were defined. Polyterpenol films were demonstrated to be hydrocarbon rich, with variable content of oxygen moieties, primarily in the form of hydroxyl and carboxyl functionalities. The level of preservation of original monomer functionality was shown to be strongly dependent on the deposition energy, with higher applied power increasing the molecular fragmentation and substrate temperature. Polyterpenol water contact angle contact angle increased from 62.7° for the 10 W samples to 76.3° for the films deposited at 100 W. Polymers were determined to resist solubilisation by water, due to the extensive intermolecular and intramolecular hydrogen bonds present, and other solvents commonly employed in electronics and biomedical processing. Independent of deposition power, the surface topography of the polymers was shown to be smooth (Rq <0.5 nm), uniform and defect free. Hardness of polyterpenol coatings increased from 0.33 GPa for 10 W to 0.51 GPa for 100 W (at 500 μN load). Coatings deposited at higher input RF powers showed less mechanical deformation during nanoscratch testing, with no considerable damage, cracking or delamination observed. Independent of the substrate, the quality of film adhesion improved with RF power, suggesting these coatings are likely to be more stable and less susceptible to wear. Independent of fabrication conditions, polyterpenol thin films were optically transparent, with refractive index approximating that of glass. Refractive index increased slightly with deposition power, from 1.54 (10 W) to 1.56 (100 W) at 500 nm. The optical band gap values declined with increasing power, from 2.95 eV to 2.64 eV, placing the material within the range for semiconductors. Introduction of iodine impurity reduced the band gap of polyterpenol, from 2.8 eV to 1.64 eV, by extending the density of states more into the visible region of the electromagnetic spectrum. Doping decreased the transparency and increased the refractive index from 1.54 to 1.70 (at 500 nm). At optical frequencies, the real part of permittivity (k) was determined to be between 2.34 and 2.65, indicating a potential low-k material. These permittivity values were confirmed at microwave frequencies, where permittivity increased with input RF energy – from 2.32 to 2.53 (at 10 GHz ) and from 2.65 to 2.83 (at 20 GHz). At low frequencies, the dielectric constant was determined from current−voltage characteristics of Al−polyterpenol−Al devices. At frequencies below 100 kHz, the dielectric constant varied with RF power, from 3.86 to 4.42 at 1 kHz. For all samples, the resistivity was in order of 10⁸−10⁹ _m (at 6 V), confirming the insulating nature of polyterpenol material. In situ iodine doping was demonstrated to increase the conductivity of polyterpenol, from 5.05 × 10⁻⁸ S/cm to 1.20 × 10⁻⁶ S/cm (at 20 V). Exposed to ambient conditions over extended period of time, polyterpenol thin films were demonstrated to be optically, physically and chemically stable. The bulk of ageing occurred within first 150 h after deposition and was attributed to oxidation and volumetric relaxation. Thermal ageing studies indicated thermal stability increased for the films manufactured at higher RF powers, with degradation onset temperature associated with weight loss shifting from 150 ºC to 205 ºC for 10 W and 100 W polyterpenol, respectively. Annealing the films to 405 °C resulted in full dissociation of the polymer, with minimal residue. Given the outcomes of the fundamental characterisation, a number of potential applications for polyterpenol have been identified. Flexibility, tunable permittivity and loss tangent properties of polyterpenol suggest the material can be used as an insulating layer in plastic electronics. Implementation of polyterpenol as a surface modification of the gate insulator in pentacene-based Field Effect Transistor resulted in significant improvements, shifting the threshold voltage from + 20 V to –3 V, enhancing the effective mobility from 0.012 to 0.021 cm²/Vs, and improving the switching property of the device from 10⁷ to 10⁴. Polyterpenol was demonstrated to have a hole transport electron blocking property, with potential applications in many organic devices, such as organic light emitting diodes. Encapsulation of biomedical devices is also proposed, given that under favourable conditions, the original chemical and biological functionality of terpinen−4−ol molecule can be preserved. Films deposited at low RF power were shown to successfully prevent adhesion and retention of several important human pathogens, including P. aeruginosa, S. aureus, and S. epidermidis, whereas films deposited at higher RF power promoted bacterial cell adhesion and biofilm formation. Preliminary investigations into in vitro biocompatibility of polyterpenol demonstrated the coating to be non−toxic for several types of eukaryotic cells, including Balb/c mice macrophage and human monocyte type (HTP−1 non-adherent) cells. Applied to magnesium substrates, polyterpenol encapsulating layer significantly slowed down in vitro biodegradation of the metal, thus increasing the viability and growth of HTP−1 cells. Recently, applied to varied nanostructured titanium surfaces, polyterpenol thin films successfully reduced attachment, growth, and viability of P. aeruginosa and S. aureus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Familial isolated hyperparathyroidism (FIHP) is an autosomal dominantly inherited form of primary hyperparathyroidism. Although comprising only about 1% of cases of primary hyperparathyroidism, identification and functional analysis of a causative gene for FIHP is likely to advance our understanding of parathyroid physiology and pathophysiology. METHODS: A genome-wide screen of DNA from seven pedigrees with FIHP was undertaken in order to identify a region of genetic linkage with the disorder. RESULTS: Multipoint linkage analysis identified a region of suggestive linkage (LOD score 2.68) on chromosome 2. Fine mapping with the addition of three other families revealed significant linkage adjacent to D2S2368 (maximum multipoint LOD score 3.43). Recombination events defined a 1.7 Mb region of linkage between D2S2368 and D2S358 in nine pedigrees. Sequencing of the two most likely candidate genes in this region, however, did not identify a gene for FIHP. CONCLUSIONS: We conclude that a causative gene for FIHP lies within this interval on chromosome 2. This is a major step towards eventual precise identification of a gene for FIHP, likely to be a key component in the genetic regulation of calcium homeostasis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To describe distributions of ocular biometry and their associations with refraction in 7- and 14-year-old children in urban areas of Anyang, central China. Methods: A total of 2271 grade 1 students aged 7.1 ± 0.4 years and 1786 grade 8 students aged 13.7 ± 0.5 years were measured with ocular biometry and cycloplegic refraction. A parental myopia questionnaire was administered to parents. Results: Mean axial length, anterior chamber depth, lens thickness, central corneal thickness, corneal diameter, corneal radius of curvature, axial length/corneal radius of curvature ratio, and spherical equivalent refraction were 22.72 ± 0.76 mm, 2.89 ± 0.24 mm, 3.61 ± 0.19 mm, 540.5 ± 31 μm, 12.06 ± 0.44 mm, 7.80 ± 0.25 mm, 2.91 ± 0.08, and +0.95 ± 1.05 diopters (D), respectively, in 7-year-old children. They were 24.39 ± 1.13 mm, 3.42 ± 0.41 mm, 3.18 ± 0.24 mm, 548.9 ± 33 μm, 12.03 ± 0.43 mm, 7.80 ± 0.26 mm, 3.13 ± 0.14, and −2.06 ± 2.20 D, respectively, in 14-year-old children. Compared with 7-year-old children, the older group had significantly more myopia (−3.0 D), longer axial length (1.7 mm), deeper anterior chamber depth (0.3 mm), thinner lens thickness (−0.2 mm), thicker central corneal thickness (10 μm), and greater axial length/corneal radius of curvature ratio (0.22) (all p < 0.001), as well as smaller corneal diameter (−0.03 mm, p = 0.02) and similar corneal radius of curvature. Sex differences were similar in both age groups, with boys having longer axial length (0.5 mm), deeper anterior chamber depth (0.1 mm), shorter lens thickness (0.03 mm), greater central corneal thickness (5 μm), greater corneal diameter (0.15 mm), and greater corneal radius of curvature (0.14 mm) than girls (all p < 0.01). The most important variables related to spherical equivalent refraction were vitreous length, corneal radius of curvature, and lens thickness. Conclusions: The 14-year-old group had larger parameter dimensions than the 7-year-old group except for corneal radius of curvature (unchanged) and lens thickness and corneal diameter (both smaller). Boys had large parameter dimensions than girls except for lens thickness (smaller). Axial length, corneal radius of curvature, and lens thickness were the most important determinants of refraction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To determine the distribution of peripheral refraction, including astigmatism, in 7- and 14-year-old Chinese children. Methods: 2134 7-year-old and 1780 14-year-old children were measured with cycloplegic central and horizontal peripheral refraction (15° and 30° at temporal and nasal visual fields). Results: 7- and 14-year-old children included 9 and 594, respectively, with moderate and high myopia (≤−3.0 D), 259 and 831 with low myopia (−2.99 to −0.5 D), 1207 and 305 with emmetropia (−0.49 to +1.0 D), and 659 and 50 with hyperopia (>1.0 D), respectively. Myopic children had relative peripheral hyperopia while hyperopic and emmetropic children had relative peripheral myopia, with greater changes in relative peripheral refraction occurring in the nasal than the temporal visual field. The older group had the greater relative peripheral hyperopia and higher peripheral J180. Both age groups showed positive slopes of J45 across the visual field, with greater slopes in the older group. Conclusions: Myopic children in mainland China have relative peripheral hyperopia while hyperopic and emmetropic children have relative peripheral myopia. Significant differences exist between 7- and 14-year-old children, with the latter showing more relative peripheral hyperopia, greater rate of change in J45 across the visual field, and higher peripheral J180.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose.: To develop three-surface paraxial schematic eyes with different ages and sexes based on data for 7- and 14-year-old Chinese children from the Anyang Childhood Eye Study. Methods.: Six sets of paraxial schematic eyes, including 7-year-old eyes, 7-year-old male eyes, 7-year-old female eyes, 14-year-old eyes, 14-year-old male eyes, and 14-year-old female eyes, were developed. Both refraction-dependent and emmetropic eye models were developed, with the former using linear dependence of ocular parameters on refraction. Results.: A total of 2059 grade 1 children (boys 58%) and 1536 grade 8 children (boys 49%) were included, with mean age of 7.1 ± 0.4 and 13.7 ± 0.5 years, respectively. Changes in these schematic eyes with aging are increased anterior chamber depth, decreased lens thickness, increased vitreous chamber depth, increased axial length, and decreased lens equivalent power. Male schematic eyes have deeper anterior chamber depth, longer vitreous chamber depth, longer axial length, and lower lens equivalent power than female schematic eyes. Changes in the schematic eyes with positive increase in refraction are decreased anterior chamber depth, increased lens thickness, decreased vitreous chamber depth, decreased axial length, increased corneal radius of curvature, and increased lens power. In general, the emmetropic schematic eyes have biometric parameters similar to those arising from regression fits for the refraction-dependent schematic eyes. Conclusions.: The paraxial schematic eyes of Chinese children may be useful for myopia research and for facilitating comparison with other children with the same or different racial backgrounds and living in different places.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To validate a simple partial coherence interferometry (PCI) based retinal shape method, estimates of retinal shape were determined in 60 young adults using off-axis PCI, with three stages of modeling using variants of the Le Grand model eye, and magnetic resonance imaging (MRI). Stage 1 and 2 involved a basic model eye without and with surface ray deviation, respectively and Stage 3 used model with individual ocular biometry and ray deviation at surfaces. Considering the theoretical uncertainty of MRI (12-14%), the results of the study indicate good agreement between MRI and all three stages of PCI modeling with <4% and <7% differences in retinal shapes along horizontal and vertical meridians, respectively. Stage 2 and Stage 3 gave slightly different retinal co-ordinates than Stage 1 and we recommend the intermediate Stage 2 as providing a simple and valid method of determining retinal shape from PCI data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose To explore the effect of small-aperture optics, designed to aid presbyopes by increasing ocular depth-of-focus, on measurements of the visual field. Methods Simple theoretical and ray-tracing models were used to predict the impact of different designs of small-aperture contact lenses or corneal inlays on the proportion of light passing through natural pupils of various diameters as a function of the direction in the visual field. The left eyes of five healthy volunteers were tested using three afocal, hand-painted opaque soft contact lenses (www.davidthomas.com). Two were opaque over a 10 mm diameter but had central clear circular apertures of 1.5 and 3.0 mm in diameter. The third had an annular opaque zone with inner and outer diameters of 1.5 and 4.0 mm, approximately simulating the geometry of the KAMRA inlay (www.acufocus.com). A fourth, clear lens was used for comparison purposes. Visual fields along the horizontal meridian were evaluated up to 50° eccentricity with static automated perimetry (Medmont M700, stimulus Goldmann-size III; www.medmont.com). Results According to ray-tracing, the two lenses with the circular apertures were expected to reduce the relative transmittance of the pupil to zero at specific field angles (around 60° for the conditions of the experimental measurements). In contrast, the annular stop had no effect on the absolute field but relative transmittance was reduced over the central area of the field, the exact effects depending upon the natural pupil diameter. Experimental results broadly agreed with these theoretical expectations. With the 1.5 and 3.0 mm pupils, only minor losses in sensitivity (around 2 dB) in comparison with the clear-lens case occurred across the central 10° radius of field. Beyond this angle, sensitivity losses increased, to reach about 7 dB at the edge of the measured field (50°). The field results with the annular stop showed at most only a slight loss in sensitivity (≤3 dB) across the measured field. Conclusion The present theoretical and experimental results support earlier clinical findings that KAMRA-type annular stops, unlike circular artificial pupils, have only minor effects on measurements of the visual field.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To examine mean level differences, and longitudinal and reciprocal relations among behavioral sleep problems, emotional dysregulation, and attentional regulation across early childhood for children with and without ADHD at 8-9 years. Method This study used data from Growing Up in Australia: The Longitudinal Study of Australian Children (LSAC) – Infant Cohort (n = 4109 analyzed). Children with and without ADHD were identified at age 8-9 years via parent-report of ADHD diagnosis and the 5-item Inattention-Hyperactivity subscale from the Strengths and Difficulties Questionnaire. Maternal report of child sleep problems and self-regulation was collected at 0-1, 2-3, 4-5 and 6-7 years of age. ANOVA was used to compare mean level differences in sleep problems, emotional and attentional regulation by ADHD group. Longitudinal structural equation modeling examined the relations among sleep and self-regulation across time in children with and without ADHD. Results Children with ADHD had persistently elevated levels of sleep problems (from infancy) and emotional and attentional dysregulation compared to controls (from 2-3 years of age). Sleep problems, emotional dysregulation, and attentional regulation were stable over time for both groups. Sleep problems were associated with greater emotional dysregulation two years later from 2-3 years of age for both groups, which in turn was associated with poorer attentional regulation. There was no direct relationship between sleep problems and later attentional regulation. Conclusion Sleep problems in children with and without ADHD are associated with emotional dysregulation, which in turn contributes to poorer attentional functioning. This study highlights the importance of assessing and managing sleep problems in young children.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ovarian cancer is the leading cause of cancer-related death in women, and the need for curative treatments is urgent. This study characterised an enzyme associated with the most lethal form of ovarian cancer, showing this enzyme to be a promising therapeutic target. Fifteen novel protein targets and key signalling pathways were determined to be regulated by this enzyme, kallikrein-related peptidase 7, in the ovarian tumour microenvironment, highlighting its involvement in cancer progression. Inhibition of this enzyme may be a useful therapeutic option to improve the life expectancy of women suffering from this cancer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This edition testifies to the broad international reach of the journal, with contributions variously concerned with Arctic Indigenous communities, the Métis of Canada, Native Hawaiians and Māori of Aotearoa (New Zealand). Two articles stress the need to work collaboratively and respectfully with Indigenous populations whilst conducting research. The first, by Gwen Healey, notes the increased interest in health research in the Arctic, particularly with Inuit populations. Healy seeks to add to the growing body of literature concerned with Indigenous ways of knowing by highlighting Inuit concepts that inform an effective Arctic research model. The second, by primary author Peter Hutchinson and a range of co-contributors, highlights the ways in which Métis collaborators working in health developed a participatory Indigenous research method that was unique in that it foregrounded Métis relationships and relationality. In so doing, the researchers were able to give substance to otherwise staid policy statements about the need for good ethical research conduct.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This edition scales the merlons and embrasures that mark the epistemological barriers that contemporary colonising power continually puts in place. Each article harnesses a critical Indigenous perspective in order to challenge conservative approaches or positions, be they concerned with reconciliation, Indigenous-led research, research tools or the nature of Aboriginal being. The first article, by Barry Judd and Emma Barrow, examines reconciliation discourse within the higher education sector and highlights the ways a normative Anglo-Australian identity militates against genuine ‘whitefella’ attempts to ‘reconcile’. The authors stress the importance of inclusive, institutional practice that serves to decentre Anglo-centrism and which, in turn, brings Indigenous peoples more fully into the fold of Australian university life.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Early detection of (pre-)signs of ulceration on a diabetic foot is valuable for clinical practice. Hyperspectral imaging is a promising technique for detection and classification of such (pre-)signs. However, the number of the spectral bands should be limited to avoid overfitting, which is critical for pixel classification with hyperspectral image data. The goal was to design a detector/classifier based on spectral imaging (SI) with a small number of optical bandpass filters. The performance and stability of the design were also investigated. The selection of the bandpass filters boils down to a feature selection problem. A dataset was built, containing reflectance spectra of 227 skin spots from 64 patients, measured with a spectrometer. Each skin spot was annotated manually by clinicians as "healthy" or a specific (pre-)sign of ulceration. Statistical analysis on the data set showed the number of required filters is between 3 and 7, depending on additional constraints on the filter set. The stability analysis revealed that shot noise was the most critical factor affecting the classification performance. It indicated that this impact could be avoided in future SI systems with a camera sensor whose saturation level is higher than 106, or by postimage processing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thickness measurements derived from optical coherence tomography (OCT) images of the eye are a fundamental clinical and research metric, since they provide valuable information regarding the eye’s anatomical and physiological characteristics, and can assist in the diagnosis and monitoring of numerous ocular conditions. Despite the importance of these measurements, limited attention has been given to the methods used to estimate thickness in OCT images of the eye. Most current studies employing OCT use an axial thickness metric, but there is evidence that axial thickness measures may be biased by tilt and curvature of the image. In this paper, standard axial thickness calculations are compared with a variety of alternative metrics for estimating tissue thickness. These methods were tested on a data set of wide-field chorio-retinal OCT scans (field of view (FOV) 60° x 25°) to examine their performance across a wide region of interest and to demonstrate the potential effect of curvature of the posterior segment of the eye on the thickness estimates. Similarly, the effect of image tilt was systematically examined with the same range of proposed metrics. The results demonstrate that image tilt and curvature of the posterior segment can affect axial tissue thickness calculations, while alternative metrics, which are not biased by these effects, should be considered. This study demonstrates the need to consider alternative methods to calculate tissue thickness in order to avoid measurement error due to image tilt and curvature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Welcome to Volume 7 of Student Success. This editorial has two parts: The first part maintains the “doing things differently” tradition, making readers aware by chronicling the publishing of the journal in an open access (OA) forum. Future editorials will briefly discuss other aspects and issues pertaining to the new scholarly publishing landscape that this journal adheres to, such as: Creative Commons Licencing; ORCID IDs; considerations of new peer review models and importantly; measuring research impact in OA publishing. The second part presents the usual editorial summary of the content of this issue.