420 resultados para cross-likelihood ratio


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper will explore how a general education can contribute successfully to vocational outcomes using both Participatory Action Research (PAR) and Program Theory methodology. The paper will focus on the development aspects of ‘marrying’ vocational and general education including engagement processes, student, teacher, institute and employer preparation and the pathway possibilities that emerge. Successful cases presented include the: Healthy Futures program (pathways into the Health and Allied industries); Accounting Pathways program (simultaneously studying a general Accounting subject and a Certificate III vocational qualification); and Sustainable Sciences initiative (development of a vocational qualification that focuses on the emerging renewable energy industry and is linked to school science programs). The case studies have been selected because they are unique in character and application and can be used as a basis for future program development in other settings or curriculum areas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Children with early and continuously treated phenylketonuria (ECT-PKU) remain at risk of developing executive function (EF) deficits. There is some evidence that a high phenylalanine to tyrosine ratio (phe:tyr) is more strongly associated with impaired EF development than high phenylalanine alone. This study examined EF in a sample of 11 adolescents against concurrent and historical levels of phenylalanine, phe:tyr, and tyrosine. Lifetime measures of phe:tyr were more strongly associated with EF than phenylalanine-only measures. Children with a lifetime phe:tyr less than 6 demonstrated normal EF, whereas children who had a lifetime phe:tyr above 6, on average, demonstrated clinically impaired EF.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The rhetoric of the pedagogic discourses of landscape architectural students and interior design students is described as part of a doctoral study undertaken to document practices and orientations prior to cross-disciplinary collaboration. We draw on the theoretical framework of Basil Bernstein, an educational sociologist, and the rhetorical method of Kenneth Burke, a literary dramatist, to study the grammars of ‘landscape’ representation employed within these disciplinary examples. We investigate how prepared final year students are for working in a cross-disciplinary manner. The discursive interactions of their work, as illustrated by four examples of drawn images and written text, are described. Our findings suggest that we need to concern ourselves aspects of our pedagogic discourse that brings uniqueness and value to our disciplines ,as well as that shared discourses between disciplines.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The purpose of this paper is to explore the role of cross-functional teams in the alignment between system effectiveness and operational effectiveness after the implementation of enterprise information systems (EIS). In addition, it aims to explore the contribution of cross-functional teams to improvement in operational performance. ---------- Design/methodology/approach: The research uses a combination of qualitative and quantitative methods, in a two-stage methodological approach, to investigate the influence of cross-functional teams on the alignment between system effectiveness and operational effectiveness and the impact of the stated alignment on the improvement in operational performance. ---------- Findings: Initial findings suggest that factors stemming from system effectiveness and the performance objectives stemming from operational effectiveness are important and significantly well correlated factors that promote the alignment between the effectiveness of technological implementation and the effectiveness of operations. In addition, confirmatory factor analysis has been used to find the structural relationships and provide explanations for the stated alignment and the contribution of cross-functional teams to the improvement in operational performance. ---------- Research limitations/implications: The principal limitation of this study is its small sample size. ---------- Practical implications: Cross-functional teams have been used by many organisations as a way of involving expertise from different functional areas in the implementation of innovative technologies. An appropriate use of the dimensions that emerged from this research, in the context of cross-functional teams, will assist organisations to properly utilise cross-functional teams with the aim of improving operational performance. ---------- Originality/value: The paper presents a new approach to measure the effectiveness of EIS implementation by adding new dimensions to measure it.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Queensland University of Technology (QUT) allows the presentation of theses for the Degree of Doctor of Philosophy in the format of published or submitted papers, where such papers have been published, accepted or submitted during the period of candidature. This thesis is composed of ten published /submitted papers and book chapters of which nine have been published and one is under review. This project is financially supported by an Australian Research Council (ARC) Discovery Grant with the aim of investigating multilevel topologies for high quality and high power applications, with specific emphasis on renewable energy systems. The rapid evolution of renewable energy within the last several years has resulted in the design of efficient power converters suitable for medium and high-power applications such as wind turbine and photovoltaic (PV) systems. Today, the industrial trend is moving away from heavy and bulky passive components to power converter systems that use more and more semiconductor elements controlled by powerful processor systems. However, it is hard to connect the traditional converters to the high and medium voltage grids, as a single power switch cannot stand at high voltage. For these reasons, a new family of multilevel inverters has appeared as a solution for working with higher voltage levels. Besides this important feature, multilevel converters have the capability to generate stepped waveforms. Consequently, in comparison with conventional two-level inverters, they present lower switching losses, lower voltage stress across loads, lower electromagnetic interference (EMI) and higher quality output waveforms. These properties enable the connection of renewable energy sources directly to the grid without using expensive, bulky, heavy line transformers. Additionally, they minimize the size of the passive filter and increase the durability of electrical devices. However, multilevel converters have only been utilised in very particular applications, mainly due to the structural limitations, high cost and complexity of the multilevel converter system and control. New developments in the fields of power semiconductor switches and processors will favor the multilevel converters for many other fields of application. The main application for the multilevel converter presented in this work is the front-end power converter in renewable energy systems. Diode-clamped and cascade converters are the most common type of multilevel converters widely used in different renewable energy system applications. However, some drawbacks – such as capacitor voltage imbalance, number of components, and complexity of the control system – still exist, and these are investigated in the framework of this thesis. Various simulations using software simulation tools are undertaken and are used to study different cases. The feasibility of the developments is underlined with a series of experimental results. This thesis is divided into two main sections. The first section focuses on solving the capacitor voltage imbalance for a wide range of applications, and on decreasing the complexity of the control strategy on the inverter side. The idea of using sharing switches at the output structure of the DC-DC front-end converters is proposed to balance the series DC link capacitors. A new family of multioutput DC-DC converters is proposed for renewable energy systems connected to the DC link voltage of diode-clamped converters. The main objective of this type of converter is the sharing of the total output voltage into several series voltage levels using sharing switches. This solves the problems associated with capacitor voltage imbalance in diode-clamped multilevel converters. These converters adjust the variable and unregulated DC voltage generated by renewable energy systems (such as PV) to the desirable series multiple voltage levels at the inverter DC side. A multi-output boost (MOB) converter, with one inductor and series output voltage, is presented. This converter is suitable for renewable energy systems based on diode-clamped converters because it boosts the low output voltage and provides the series capacitor at the output side. A simple control strategy using cross voltage control with internal current loop is presented to obtain the desired voltage levels at the output voltage. The proposed topology and control strategy are validated by simulation and hardware results. Using the idea of voltage sharing switches, the circuit structure of different topologies of multi-output DC-DC converters – or multi-output voltage sharing (MOVS) converters – have been proposed. In order to verify the feasibility of this topology and its application, steady state and dynamic analyses have been carried out. Simulation and experiments using the proposed control strategy have verified the mathematical analysis. The second part of this thesis addresses the second problem of multilevel converters: the need to improve their quality with minimum cost and complexity. This is related to utilising asymmetrical multilevel topologies instead of conventional multilevel converters; this can increase the quality of output waveforms with a minimum number of components. It also allows for a reduction in the cost and complexity of systems while maintaining the same output quality, or for an increase in the quality while maintaining the same cost and complexity. Therefore, the asymmetrical configuration for two common types of multilevel converters – diode-clamped and cascade converters – is investigated. Also, as well as addressing the maximisation of the output voltage resolution, some technical issues – such as adjacent switching vectors – should be taken into account in asymmetrical multilevel configurations to keep the total harmonic distortion (THD) and switching losses to a minimum. Thus, the asymmetrical diode-clamped converter is proposed. An appropriate asymmetrical DC link arrangement is presented for four-level diode-clamped converters by keeping adjacent switching vectors. In this way, five-level inverter performance is achieved for the same level of complexity of the four-level inverter. Dealing with the capacitor voltage imbalance problem in asymmetrical diodeclamped converters has inspired the proposal for two different DC-DC topologies with a suitable control strategy. A Triple-Output Boost (TOB) converter and a Boost 3-Output Voltage Sharing (Boost-3OVS) converter connected to the four-level diode-clamped converter are proposed to arrange the proposed asymmetrical DC link for the high modulation indices and unity power factor. Cascade converters have shown their abilities and strengths in medium and high power applications. Using asymmetrical H-bridge inverters, more voltage levels can be generated in output voltage with the same number of components as the symmetrical converters. The concept of cascading multilevel H-bridge cells is used to propose a fifteen-level cascade inverter using a four-level H-bridge symmetrical diode-clamped converter, cascaded with classical two-level Hbridge inverters. A DC voltage ratio of cells is presented to obtain maximum voltage levels on output voltage, with adjacent switching vectors between all possible voltage levels; this can minimize the switching losses. This structure can save five isolated DC sources and twelve switches in comparison to conventional cascade converters with series two-level H bridge inverters. To increase the quality in presented hybrid topology with minimum number of components, a new cascade inverter is verified by cascading an asymmetrical four-level H-bridge diode-clamped inverter. An inverter with nineteen-level performance was achieved. This synthesizes more voltage levels with lower voltage and current THD, rather than using a symmetrical diode-clamped inverter with the same configuration and equivalent number of power components. Two different predictive current control methods for the switching states selection are proposed to minimise either losses or THD of voltage in hybrid converters. High voltage spikes at switching time in experimental results and investigation of a diode-clamped inverter structure raised another problem associated with high-level high voltage multilevel converters. Power switching components with fast switching, combined with hard switched-converters, produce high di/dt during turn off time. Thus, stray inductance of interconnections becomes an important issue and raises overvoltage and EMI issues correlated to the number of components. Planar busbar is a good candidate to reduce interconnection inductance in high power inverters compared with cables. The effect of different transient current loops on busbar physical structure of the high-voltage highlevel diode-clamped converters is highlighted. Design considerations of proper planar busbar are also presented to optimise the overall design of diode-clamped converters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this chapter we propose clipping with amplitude and phase corrections to reduce the peak-to-average power ratio (PAR) of orthogonal frequency division multiplexed (OFDM) signals in high-speed wireless local area networks defined in IEEE 802.11a physical layer. The proposed techniques can be implemented with a small modification at the transmitter and the receiver remains standard compliant. PAR reduction as much as 4dB can be achieved by selecting a suitable clipping ratio and a correction factor depending on the constellation used. Out of band noise (OBN) is also reduced.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Parallel combinatory orthogonal frequency division multiplexing (PC-OFDM yields lower maximum peak-to-average power ratio (PAR), high bandwidth efficiency and lower bit error rate (BER) on Gaussian channels compared to OFDM systems. However, PC-OFDM does not improve the statistics of PAR significantly. In this chapter, the use of a set of fixed permutations to improve the statistics of the PAR of a PC-OFDM signal is presented. For this technique, interleavers are used to produce K-1 permuted sequences from the same information sequence. The sequence with the lowest PAR, among K sequences is chosen for the transmission. The PAR of a PC-OFDM signal can be further reduced by 3-4 dB by this technique. Mathematical expressions for the complementary cumulative density function (CCDF)of PAR of PC-OFDM signal and interleaved PC-OFDM signal are also presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Physical activity has the potential to modulate appetite control by improving the sensitivity of the physiological satiety signalling system, by adjusting macronutrient preferences or food choices and by altering the hedonic response to food. There is evidence for all these actions. Concerning the impact of physical activity on energy balance, there exists a belief that physical activity drives up hunger and increases food intake, thereby rendering it futile as a method of weight control.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: This cross-cultural study compared both the symptoms of anxiety and their severity in a community sample of children from Colombia and Australia. Method: The sample comprised 516 children (253 Australian children and 263 Colombian children), aged 8 to 12-years-old. The Spence Children’s Anxiety Scale (SCAS) was used to measure both the symptoms and levels of anxiety. Results: The results showed a significant difference in the severity of the symptoms between the children in the two countries. In general, Colombian children reported more severe symptoms than their Australian peers, however there were no difference in the types of symptoms reported by the children in the two countries. Discussion and Conclusion: The implications of these findings and their importance to cross-cultural research are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Relatively little information has been reported about foot and ankle problems experienced by nurses, despite anecdotal evidence which suggests they are common ailments. The purpose of this study was to improve knowledge about the prevalence of foot and ankle musculoskeletal disorders (MSDs) and to explore relationships between these MSDs and proposed risk factors. A review of the literature relating to work-related MSDs, MSDs in nursing, foot and lower-limb MSDs, screening for work-related MSDs, foot discomfort, footwear and the prevalence of foot problems in the community was undertaken. Based on the review, theoretical risk factors were proposed that pertained to the individual characteristics of the nurses, their work activity or their work environment. Three studies were then undertaken. A cross-sectional survey of 304 nurses, working in a large tertiary paediatric hospital, established the prevalence of foot and ankle MSDs. The survey collected information about self-reported risk factors of interest. The second study involved the clinical examination of a subgroup of 40 nurses, to examine changes in body discomfort, foot discomfort and postural sway over the course of a single work shift. Objective measurements of additional risk factors, such as individual foot posture (arch index) and the hardness of shoe midsoles, were performed. A final study was used to confirm the test-retest reliability of important aspects of the survey and key clinical measurements. Foot and ankle problems were the most common MSDs experienced by nurses in the preceding seven days (42.7% of nurses). They were the second most common MSDs to cause disability in the last 12 months (17.4% of nurses), and the third most common MSDs experienced by nurses in the last 12 months (54% of nurses). Substantial foot discomfort (Visual Analogue Scale (VAS) score of 50mm or more) was experienced by 48.5% of nurses at sometime in the last 12 months. Individual risk factors, such as obesity and the number of self-reported foot conditions (e.g., callouses, curled toes, flat feet) were strongly associated with the likelihood of experiencing foot problems in the last seven days or during the last 12 months. These risk factors showed consistent associations with disabling foot conditions and substantial foot discomfort. Some of these associations were dependent upon work-related risk factors, such as the location within the hospital and the average hours worked per week. Working in the intensive care unit was associated with higher odds of experiencing foot problems within the last seven days, foot problems in the last 12 months and foot problems that impaired activity in the last 12 months. Changes in foot discomfort experienced within a day, showed large individual variability. Fifteen of the forty nurses experienced moderate/substantial foot discomfort at the end of their shift (VAS 25+mm). Analysis of the association between risk factors and moderate/substantial foot discomfort revealed that foot discomfort was less likely for nurses who were older, had greater BMI or had lower foot arches, as indicated by higher arch index scores. The nurses’ postural sway decreased over the course of the work shift, suggesting improved body balance by the end of the day. These findings were unexpected. Further clinical studies examining individual nurses on several work shifts are needed to confirm these results, particularly due to the small sample size and the single measurement occasion. There are more than 280,000 nurses registered to practice in Australia. The nursing workforce is ageing and the prevalence of foot problems will increase. If the prevalence estimates from this study are extrapolated to the profession generally, more than 70,000 hospital nurses have experienced substantial foot discomfort and 25-30,000 hospital nurses have been limited in their activity due to foot problems during the last 12 months. Nurses with underlying foot conditions were more likely to report having foot problems at work. Strategies to prevent or manage foot conditions exist and they should be disseminated to nurses. Obesity is a significant risk factor for foot and ankle MSDs and these nurses may need particular assistance to manage foot problems. The risk of foot problems for particular groups of nurses, e.g. obese nurses, may vary depending upon the location within the hospital. Further research is needed to confirm the findings of this study. Similar studies should be conducted in other occupational groups that require workers to stand for prolonged periods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis deals with the problem of the instantaneous frequency (IF) estimation of sinusoidal signals. This topic plays significant role in signal processing and communications. Depending on the type of the signal, two major approaches are considered. For IF estimation of single-tone or digitally-modulated sinusoidal signals (like frequency shift keying signals) the approach of digital phase-locked loops (DPLLs) is considered, and this is Part-I of this thesis. For FM signals the approach of time-frequency analysis is considered, and this is Part-II of the thesis. In part-I we have utilized sinusoidal DPLLs with non-uniform sampling scheme as this type is widely used in communication systems. The digital tanlock loop (DTL) has introduced significant advantages over other existing DPLLs. In the last 10 years many efforts have been made to improve DTL performance. However, this loop and all of its modifications utilizes Hilbert transformer (HT) to produce a signal-independent 90-degree phase-shifted version of the input signal. Hilbert transformer can be realized approximately using a finite impulse response (FIR) digital filter. This realization introduces further complexity in the loop in addition to approximations and frequency limitations on the input signal. We have tried to avoid practical difficulties associated with the conventional tanlock scheme while keeping its advantages. A time-delay is utilized in the tanlock scheme of DTL to produce a signal-dependent phase shift. This gave rise to the time-delay digital tanlock loop (TDTL). Fixed point theorems are used to analyze the behavior of the new loop. As such TDTL combines the two major approaches in DPLLs: the non-linear approach of sinusoidal DPLL based on fixed point analysis, and the linear tanlock approach based on the arctan phase detection. TDTL preserves the main advantages of the DTL despite its reduced structure. An application of TDTL in FSK demodulation is also considered. This idea of replacing HT by a time-delay may be of interest in other signal processing systems. Hence we have analyzed and compared the behaviors of the HT and the time-delay in the presence of additive Gaussian noise. Based on the above analysis, the behavior of the first and second-order TDTLs has been analyzed in additive Gaussian noise. Since DPLLs need time for locking, they are normally not efficient in tracking the continuously changing frequencies of non-stationary signals, i.e. signals with time-varying spectra. Nonstationary signals are of importance in synthetic and real life applications. An example is the frequency-modulated (FM) signals widely used in communication systems. Part-II of this thesis is dedicated for the IF estimation of non-stationary signals. For such signals the classical spectral techniques break down, due to the time-varying nature of their spectra, and more advanced techniques should be utilized. For the purpose of instantaneous frequency estimation of non-stationary signals there are two major approaches: parametric and non-parametric. We chose the non-parametric approach which is based on time-frequency analysis. This approach is computationally less expensive and more effective in dealing with multicomponent signals, which are the main aim of this part of the thesis. A time-frequency distribution (TFD) of a signal is a two-dimensional transformation of the signal to the time-frequency domain. Multicomponent signals can be identified by multiple energy peaks in the time-frequency domain. Many real life and synthetic signals are of multicomponent nature and there is little in the literature concerning IF estimation of such signals. This is why we have concentrated on multicomponent signals in Part-H. An adaptive algorithm for IF estimation using the quadratic time-frequency distributions has been analyzed. A class of time-frequency distributions that are more suitable for this purpose has been proposed. The kernels of this class are time-only or one-dimensional, rather than the time-lag (two-dimensional) kernels. Hence this class has been named as the T -class. If the parameters of these TFDs are properly chosen, they are more efficient than the existing fixed-kernel TFDs in terms of resolution (energy concentration around the IF) and artifacts reduction. The T-distributions has been used in the IF adaptive algorithm and proved to be efficient in tracking rapidly changing frequencies. They also enables direct amplitude estimation for the components of a multicomponent

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In recent years, multilevel converters are becoming more popular and attractive than traditional converters in high voltage and high power applications. Multilevel converters are particularly suitable for harmonic reduction in high power applications where semiconductor devices are not able to operate at high switching frequencies or in high voltage applications where multilevel converters reduce the need to connect devices in series to achieve high switch voltage ratings. This thesis investigated two aspects of multilevel converters: structure and control. The first part of this thesis focuses on inductance between a DC supply and inverter components in order to minimise loop inductance, which causes overvoltages and stored energy losses during switching. Three dimensional finite element simulations and experimental tests have been carried out for all sections to verify theoretical developments. The major contributions of this section of the thesis are as follows: The use of a large area thin conductor sheet with a rectangular cross section separated by dielectric sheets (planar busbar) instead of circular cross section wires, contributes to a reduction of the stray inductance. A number of approximate equations exist for calculating the inductance of a rectangular conductor but an assumption was made that the current density was uniform throughout the conductors. This assumption is not valid for an inverter with a point injection of current. A mathematical analysis of a planar bus bar has been performed at low and high frequencies and the inductance and the resistance values between the two points of the planar busbar have been determined. A new physical structure for a voltage source inverter with symmetrical planar bus bar structure called Reduced Layer Planar Bus bar, is proposed in this thesis based on the current point injection theory. This new type of planar busbar minimises the variation in stray inductance for different switching states. The reduced layer planar busbar is a new innovation in planar busbars for high power inverters with minimum separation between busbars, optimum stray inductance and improved thermal performances. This type of the planar busbar is suitable for high power inverters, where the voltage source is supported by several capacitors in parallel in order to provide a low ripple DC voltage during operation. A two layer planar busbar with different materials has been analysed theoretically in order to determine the resistance of bus bars during switching. Increasing the resistance of the planar busbar can gain a damping ratio between stray inductance and capacitance and affects the performance of current loop during switching. The aim of this section is to increase the resistance of the planar bus bar at high frequencies (during switching) and without significantly increasing the planar busbar resistance at low frequency (50 Hz) using the skin effect. This contribution shows a novel structure of busbar suitable for high power applications where high resistance is required at switching times. In multilevel converters there are different loop inductances between busbars and power switches associated with different switching states. The aim of this research is to consider all combinations of the switching states for each multilevel converter topology and identify the loop inductance for each switching state. Results show that the physical layout of the busbars is very important for minimisation of the loop inductance at each switch state. Novel symmetrical busbar structures are proposed for multilevel converters with diode-clamp and flying-capacitor topologies which minimise the worst case in stray inductance for different switching states. Overshoot voltages and thermal problems are considered for each topology to optimise the planar busbar structure. In the second part of the thesis, closed loop current techniques have been investigated for single and three phase multilevel converters. The aims of this section are to investigate and propose suitable current controllers such as hysteresis and predictive techniques for multilevel converters with low harmonic distortion and switching losses. This section of the thesis can be classified into three parts as follows: An optimum space vector modulation technique for a three-phase voltage source inverter based on a minimum-loss strategy is proposed. One of the degrees of freedom for optimisation of the space vector modulation is the selection of the zero vectors in the switching sequence. This new method improves switching transitions per cycle for a given level of distortion as the zero vector does not alternate between each sector. The harmonic spectrum and weighted total harmonic distortion for these strategies are compared and results show up to 7% weighted total harmonic distortion improvement over the previous minimum-loss strategy. The concept of SVM technique is a very convenient representation of a set of three-phase voltages or currents used for current control techniques. A new hysteresis current control technique for a single-phase multilevel converter with flying-capacitor topology is developed. This technique is based on magnitude and time errors to optimise the level change of converter output voltage. This method also considers how to improve unbalanced voltages of capacitors using voltage vectors in order to minimise switching losses. Logic controls require handling a large number of switches and a Programmable Logic Device (PLD) is a natural implementation for state transition description. The simulation and experimental results describe and verify the current control technique for the converter. A novel predictive current control technique is proposed for a three-phase multilevel converter, which controls the capacitors' voltage and load current with minimum current ripple and switching losses. The advantage of this contribution is that the technique can be applied to more voltage levels without significantly changing the control circuit. The three-phase five-level inverter with a pure inductive load has been implemented to track three-phase reference currents using analogue circuits and a programmable logic device.