150 resultados para Total Erythrocyte Count


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Successful anatomic fitting of a total artificial heart (TAH) is vital to achieve optimal pump hemodynamics after device implantation. Although many anatomic fitting studies have been completed in humans prior to clinical trials, few reports exist that detail the experience in animals for in vivo device evaluation. Optimal hemodynamics are crucial throughout the in vivo phase to direct design iterations and ultimately validate device performance prior to pivotal human trials. In vivo evaluation in a sheep model allows a realistically sized representation of a smaller patient, for which smaller third-generation TAHs have the potential to treat. Our study aimed to assess the anatomic fit of a single device rotary TAH in sheep prior to animal trials and to use the data to develop a threedimensional, computer-aided design (CAD)-operated anatomic fitting tool for future TAH development. Following excision of the native ventricles above the atrio-ventricular groove, a prototype TAH was inserted within the chest cavity of six sheep (28–40 kg).Adjustable rods representing inlet and outlet conduits were oriented toward the center of each atrial chamber and the great vessels, with conduit lengths and angles recorded for future analysis. A threedimensional, CAD-operated anatomic fitting tool was then developed, based on the results of this study, and used to determine the inflow and outflow conduit orientation of the TAH. The mean diameters of the sheep left atrium, right atrium, aorta, and pulmonary artery were 39, 33, 12, and 11 mm, respectively. The center-to-center distance and outer-edge-to-outer-edge distance between the atria, found to be 39 ± 9 mm and 72 ± 17 mm in this study, were identified as the most critical geometries for successful TAH connection. This geometric constraint restricts the maximum separation allowable between left and right inlet ports of a TAH to ensure successful alignment within the available atrial circumference.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis studied technology’s role in promoting and supporting active lifestyles through behavioural strategies to reduce sedentary time and increase physical activity. The five studies included (1) development of a self-report instrument quantifying daily sedentary behaviour and light-intensity physical activity; (2) establishment of instrument validity and reliability; (3) use of an online personal activity monitor to successfully reduce sedentary time and increase physical activity; (4) identification of positive differences in total wellness as related to high/low levels of sitting time combined with insufficient/sufficient physical activity; and (5) improvement of total wellness through positive changes in sedentary behaviour and physical activity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background The construct of total wellness includes a holistic approach to the body, mind and spirit components of life. While the health benefits of reducing sedentary behavior and increasing physical activity are well documented, little is known about the influence on total wellness of an internet-based physical activity monitor designed to help people to achieve higher physical activity levels. Purpose The purpose of this four-week, personal activity monitor-based intervention program was to reduce sedentary behavior and increase physical activity levels in daily living for sedentary adults and to determine if these changes would also be associated with improvement in total wellness. Methods Twenty-two men and 11 women (27 years ± 4.0) were randomly assigned to either an intervention (n = 18) or control group (n = 15). The intervention group interacted with an online personal activity monitor (Gruve Solution™) designed to reduce sedentary time and increase physical activity during activities of daily living. The control group did not interact with the monitor, as they were asked to follow their normal daily physical activities and sedentary behavior routines. The Wellness Evaluation of Lifestyle (WEL) inventory was used to assess total wellness. Sedentary time, light, walking, moderate and vigorous intensity physical activities were assessed for both intervention and control groups at baseline and at week-4 by the 7-day Sedentary and Light Intensity Physical Activity Log (7-day SLIPA Log) and the International Physical Activity Questionnaire (IPAQ). Results Significant increases in pre-post total wellness scores (from 64% ± 5.7 to 75% ± 8.5) (t (17) = -6.5, p < 0.001) were observed in the intervention group by the end of week four. Intervention participants decreased their sedentary time (21%, 2.3 hours/day) and increased their light (36.7%, 2.5 hours/day), walking (65%, 1057 MET-min/week), moderate (67%, 455 MET-min/week) and vigorous intensity (60%, 442 MET-min/week) physical activity (all p < 0.001). No significant differences for total wellness were observed between the groups at baseline and no pre-post significant differences were observed for any outcome variable in the control group. Conclusion Total wellness is improved when sedentary, but sufficiently physically active adults, reduce sedentary time and increase physical activity levels (i.e. light, walking, moderate and vigorous).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Under the concept of Total Quality Control, based on their experience, the authors discussed potential demand for quality of immunization services and possible solutions to these demands. Abstract in Chinese 全面质量管理(total quality control,TQC)是在20世纪60年代由美国人V,Feigonbaum和J.unan先后提出的新的质量管理观念,众所周知的ISO9000族标准即建立在TQC理念下的质量管理标准,该标准已成为当今世界全球一致、最具权威的质量管理和质量保证的国际规则[1-2].21世纪是质量世纪,推行TQC,不断改进产品和服务质量,目前已成为我国各行各业在不断激烈的市场竞争下完善自我、保证生存和发展的重要手段.实施预防接种是预防和控制传染病,保护人群健康的重要措施,预防接种工作中,产品即预防接种服务,需方(顾客)为接受预防接种服务的广大人群,是产品的消费者.随社会的迅速发展,人们对健康需求的不断提高,对预防接种工作也提出了更高的质量要求.本文对TQC模式下顾客对预防接种服务的质量要求进行了综合分析,并对如何改进服务质量进行了初步探讨.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Microvessel density, an indirect measure of angiogenesis, has been shown to be an independent prognostic marker in many solid tumours including non-small cell lung cancer (NSCLC). Platelets transport and release angiogenic growth factors. Platelets are increasingly likely to adhere to tumour microvessels due to raised expression of platelet-binding proteins and stasis in blood-flow. Increased vascular permeability in tumour microvessels facilitates platelet extravasation into the extracellular matrix. Adherence and extravasation both lead to platelet activation and release of growth factors capable of instigating the angiogenic process. Methods: A total of 181 patients were identified who underwent resection of stage I-IIIa NSCLC with a post-operative survival >60 days. Patients were followed-up for a minimum of 24 months. Sections from the tumour periphery were stained for the endothelial marker CD34 (Novocastra NCL-END) using standard ABC immunohistochemistry. Chalkley counting was used to assess microvessel density. Results: A pre-operative platelet count greater than the median and above the normal range (>400) was associated with a poor outcome (P = 0.01 and P = 0.04, respectively). Tumours with an above median and high Chalkley count (upper tertile) had a worse prognosis (P = 0.007 and P = 0.0006, respectively). There was no association between platelet count and Chalkley count. Conclusions: Platelet and microvessel counts are both potential prognostic markers for NSCLC. The role of platelets in the angiogenic process needs to be further investigated. (C) 2000 Elsevier Science Ireland Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Total Artificial Hearts are mechanical pumps which can be used to replace the failing natural heart. This novel study developed a means of controlling a new design of pump to reproduce physiological flow bringing closer the realisation of a practical artificial heart. Using a mathematical model of the device, an optimisation algorithm was used to determine the best configuration for the magnetic levitation system of the pump. The prototype device was constructed and tested in a mock circulation loop. A physiological controller was designed to replicate the Frank-Starling like balancing behaviour of the natural heart. The device and controller provided sufficient support for a human patient while also demonstrating good response to various physiological conditions and events. This novel work brings the design of a practical artificial heart closer to realisation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Whilst resistance training has been proven to convey considerable benefits to older people; immediately post-exercise there may be elevated transient risks for cardiac events and falls. Objectives and Measurements We assessed the acute effects of eccentrically-biased (EB) and conventional (CONV) resistance exercise on: platelet number, activation and granule exocytsosis; and mean velocity of centre of pressure displacement (Vm). Design, Setting, Participants and Intervention Ten older adults (7 males, 3 females; 69 ± 4 years) participated in this randomised controlled cross-over study in which they performed EB and CONV training sessions that were matched for total work and a control condition. Results Immediately post-exercise there was a statistically significant difference in platelet count between the control condition, in which it fell (pre 224 ± 35 109/L; post 211 ± 30 109/L: P < 0.05) and CONV in which it increased (pre 236 ± 55 109/L; post 242 ± 51 109/L: P > 0.05). There was no change in platelet activation and granule exocytsosis or Vm following EB and CONV. Conclusions Overall, while minor differences between regimens were observed, no major adverse effect on parameters of platelet function or centre of pressure displacement were observed acutely following either regimen. Eccentrically-biased and conventional resistance exercise training regimens do not appear to present an elevated acute risk in the context of changes to platelet function contributing to a cardiac event or postural stability increasing falls risk for apparently healthy older adults.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stagnation-point total heat transfer was measured on a 1:27.7 model of the Flight Investigation of Reentry Environment II flight vehicle. Experiments were performed in the X1 expansion tube at an equivalent flight velocity and static enthalpy of 11 km/s and 12.7 MJ/kg, respectively. Conditions were chosen to replicate the flight condition at a total flight time of 1639.5 s, where radiation contributed an estimated 17-36% of the total heat transfer. This contribution is theorized to reduce to <2% in the scaled experiments, and the heating environment on the test model was expected to be dominated by convection. A correlation between reported flight heating rates and expected experimental heating, referred to as the reduced flight value, was developed to predict the level of heating expected on the test model. At the given flow conditions, the reduced flight value was calculated to be 150 MW/m2. Average stagnation-point total heat transfer was measured to be 140 ± 7% W/m2, showing good agreement with the predicted value. Experimentally measured heat transfer was found to have good agreement of between 5 and 15% with a number of convective heating correlations, confirming that convection dominates the tunnel heating environment, and that useful experimental measurements could be made in weakly coupled radiating flow

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have developed a method to test the cytotoxicity of wound dressings, ointments, creams and gels used in our Burn Centre, by placing them on a permeable Nunc Polycarbonate cell culture insert, incubated with a monolayer of cells (HaCaTs and primary human keratinocytes). METHODS: We performed two different methods to determine the relative toxicity to cells. (1) Photo visualisation: The dressings or compounds were positioned on the insert's membrane which was placed onto the monolayer tissue culture plate. After 24 h the surviving adherent cells were stained with Toluidine Blue and photos of the plates were taken. The acellular area of non-adherent dead cells which had been washed off with buffer was measured as a percentage of the total area of the plate. (2) Cell count of surviving cells: After 24 h incubation with the test material, the remaining cells were detached with trypsin, spun down and counted in a Haemocytometer with Trypan Blue, which differentiates between live and dead cells. RESULTS: Seventeen products were tested. The least cytotoxic products were Melolite, White soft Paraffin and Chlorsig1% Ointment. Some cytotoxicity was shown with Jelonet, Mepitel((R)), PolyMem((R)), DuoDerm((R)) and Xeroform. The most cytotoxic products included those which contained silver or Chlorhexidine and Paraffin Cream a moisturizer which contains the preservative Chlorocresol. CONCLUSION: This in vitro cell culture insert method allows testing of agents without direct cell contact. It is easy and quick to perform, and should help the clinician to determine the relative cytotoxicity of various dressings and the optimal dressing for each individual wound.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Australia's economic growth and national identity have been widely celebrated as being founded on the nation's natural resources. With the golden era of pastoralism fading into the distance, a renewed love affair with primary industries has been much lauded, particularly by purveyors of neoliberal ideology. The considerable wealth generated by resource extraction has, despite its environmental and social record, proved seductive to the university sector. The mining industry is one of a number of industries and sectors (alongside pharmaceutical, chemical and biotechnological) that is increasingly courting Australian universities. These new public-private alliances are often viewed as the much-needed cash cow to bridge the public funding shortfall in the tertiary sector. However, this trend also raises profound questions about the capacity of public good institutions, as universities were once assumed to be, to maintain institutional independence and academic freedoms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Prevention strategies are critical to reduce infection rates in total joint arthroplasty (TJA), but evidence-based consensus guidelines on prevention of surgical site infection (SSI) remain heterogeneous and do not necessarily represent this particular patient population. Questions/Purposes What infection prevention measures are recommended by consensus evidence-based guidelines for prevention of periprosthetic joint infection? How do these recommendations compare to expert consensus on infection prevention strategies from orthopedic surgeons from the largest international tertiary referral centers for TJA? Patients and Methods A review of consensus guidelines was undertaken as described by Merollini et al. Four clinical guidelines met inclusion criteria: Centers for Disease Control and Prevention's, British Orthopedic Association, National Institute of Clinical Excellence's, and National Health and Medical Research Council's (NHMRC). Twenty-eight recommendations from these guidelines were used to create an evidence-based survey of infection prevention strategies that was administered to 28 orthopedic surgeons from members of the International Society of Orthopedic Centers. The results between existing consensus guidelines and expert opinion were then compared. Results Recommended strategies in the guidelines such as prophylactic antibiotics, preoperative skin preparation of patients and staff, and sterile surgical attire were considered critically or significantly important by the surveyed surgeons. Additional strategies such as ultraclean air/laminar flow, antibiotic cement, wound irrigation, and preoperative blood glucose control were also considered highly important by surveyed surgeons, but were not recommended or not uniformly addressed in existing guidelines on SSI prevention. Conclusion Current evidence-based guidelines are incomplete and evidence should be updated specifically to address patient needs undergoing TJA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To synthesise the available evidence and estimate the comparative efficacy of control strategies to prevent total hip replacement (THR)-related surgical site infections (SSIs) using a mixed treatment comparison. DESIGN: Systematic review and mixed treatment comparison. SETTING: Hospital and other healthcare settings. PARTICIPANTS: Patients undergoing THR. PRIMARY AND SECONDARY OUTCOME MEASURES: The number of THR-related SSIs occurring following the surgical operation. RESULTS: 12 studies involving 123 788 THRs and 9 infection control strategies were identified. The strategy of 'systemic antibiotics+antibiotic-impregnated cement+conventional ventilation' significantly reduced the risk of THR-related SSI compared with the referent strategy (no systemic antibiotics+plain cement+conventional ventilation), OR 0.13 (95% credible interval (CrI) 0.03-0.35), and had the highest probability (47-64%) and highest median rank of being the most effective strategy. There was some evidence to suggest that 'systemic antibiotics+antibiotic-impregnated cement+laminar airflow' could potentially increase infection risk compared with 'systemic antibiotics+antibiotic-impregnated cement+conventional ventilation', 1.96 (95% CrI 0.52-5.37). There was no high-quality evidence that antibiotic-impregnated cement without systemic antibiotic prophylaxis was effective in reducing infection compared with plain cement with systemic antibiotics, 1.28 (95% CrI 0.38-3.38). CONCLUSIONS: We found no convincing evidence in favour of the use of laminar airflow over conventional ventilation for prevention of THR-related SSIs, yet laminar airflow is costly and widely used. Antibiotic-impregnated cement without systemic antibiotics may not be effective in reducing THR-related SSIs. The combination with the highest confidence for reducing SSIs was 'systemic antibiotics+antibiotic-impregnated cement+conventional ventilation'. Our evidence synthesis underscores the need to review current guidelines based on the available evidence, and to conduct further high-quality double-blind randomised controlled trials to better inform the current clinical guidelines and practice for prevention of THR-related SSIs.