133 resultados para Topology.
Resumo:
This paper considers the design of a radial flux permanent magnet ironless core brushless DC motor for use in an electric wheel drive with an integrated epicyclic gear reduction. The motor has been designed for a continuous output torque of 30 Nm and peak rating of 60 Nm with a maximum operating speed of 7000 RPM. In the design of brushless DC motors with a toothed iron stator the peak air-gap magnetic flux density is typically chosen to be close to that of the remanence value of the magnets used. This paper demonstrates that for an ironless motor the optimal peak air-gap flux density is closer to the maximum energy product of the magnets used. The use of a radial flux topology allows for high frequency operation and can be shown to give high specific power output while maintaining a relatively low magnet mass. Two-dimensional finite element analysis is used to predict the airgap flux density. The motor design is based around commonly available NdFeB bar magnet size
Resumo:
The overarching aim of this programme of work was to evaluate the effectiveness of the existing learning environment within the Australian Institute of Sport (AIS) elite springboard diving programme. Unique to the current research programme, is the application of ideas from an established theory of motor learning, specifically ecological dynamics, to an applied high performance training environment. In this research programme springboard diving is examined as a complex system, where individual, task, and environmental constraints are continually interacting to shape performance. As a consequence, this thesis presents some necessary and unique insights into representative learning design and movement adaptations in a sample of elite athletes. The questions examined in this programme of work relate to how best to structure practice, which is central to developing an effective learning environment in a high performance setting. Specifically, the series of studies reported in the chapters of this doctoral thesis: (i) provide evidence for the importance of designing representative practice tasks in training; (ii) establish that completed and baulked (prematurely terminated) take-offs are not different enough to justify the abortion of a planned dive; and (iii), confirm that elite athletes performing complex skills are able to adapt their movement patterns to achieve consistent performance outcomes from variable dive take-off conditions. Chapters One and Two of the thesis provide an overview of the theoretical ideas framing the programme of work, and include a review of literature pertinent to the research aims and subsequent empirical chapters. Chapter Three examined the representativeness of take-off tasks completed in the two AIS diving training facilities routinely used in springboard diving. Results highlighted differences in the preparatory phase of reverse dive take-offs completed by elite divers during normal training tasks in the dry-land and aquatic training environments. The most noticeable differences in dive take-off between environments began during the hurdle (step, jump, height and flight) where the diver generates the necessary momentum to complete the dive. Consequently, greater step lengths, jump heights and flight times, resulted in greater board depression prior to take-off in the aquatic environment where the dives required greater amounts of rotation. The differences observed between the preparatory phases of reverse dive take-offs completed in the dry-land and aquatic training environments are arguably a consequence of the constraints of the training environment. Specifically, differences in the environmental information available to the athletes, and the need to alter the landing (feet first vs. wrist first landing) from the take-off, resulted in a decoupling of important perception and action information and a decomposition of the dive take-off task. In attempting to only practise high quality dives, many athletes have followed a traditional motor learning approach (Schmidt, 1975) and tried to eliminate take-off variations during training. Chapter Four examined whether observable differences existed between the movement kinematics of elite divers in the preparation phases of baulked (prematurely terminated) and completed take-offs that might justify this approach to training. Qualitative and quantitative analyses of variability within conditions revealed greater consistency and less variability when dives were completed, and greater variability amongst baulked take-offs for all participants. Based on these findings, it is probable that athletes choose to abort a planned take-off when they detect small variations from the movement patterns (e.g., step lengths, jump height, springboard depression) of highly practiced comfortable dives. However, with no major differences in coordination patterns (topology of the angle-angle plots), and the potential for negative performance outcomes in competition, there appears to be no training advantage in baulking on unsatisfactory take-offs during training, except when a threat of injury is perceived by the athlete. Instead, it was considered that enhancing the athletes' movement adaptability would be a more functional motor learning strategy. In Chapter Five, a twelve-week training programme was conducted to determine whether a sample of elite divers were able to adapt their movement patterns and complete dives successfully, regardless of the perceived quality of their preparatory movements on the springboard. The data indeed suggested that elite divers were able to adapt their movements during the preparatory phase of the take-off and complete good quality dives under more varied take-off conditions; displaying greater consistency and stability in the key performance outcome (dive entry). These findings are in line with previous research findings from other sports (e.g., shooting, triple jump and basketball) and demonstrate how functional or compensatory movement variability can afford greater flexibility in task execution. By previously only practising dives with good quality take-offs, it can be argued that divers only developed strong couplings between information and movement under very specific performance circumstances. As a result, this sample was sometimes characterised by poor performance in competition when the athletes experienced a suboptimal take-off. Throughout this training programme, where divers were encouraged to minimise baulking and attempt to complete every dive, they demonstrated that it was possible to strengthen the information and movement coupling in a variety of performance circumstances, widening of the basin of performance solutions and providing alternative couplings to solve a performance problem even when the take-off was not ideal. The results of this programme of research provide theoretical and experimental implications for understanding representative learning design and movement pattern variability in applied sports science research. Theoretically, this PhD programme contributes empirical evidence to demonstrate the importance of representative design in the training environments of high performance sports programmes. Specifically, this thesis advocates for the design of learning environments that effectively capture and enhance functional and flexible movement responses representative of performance contexts. Further, data from this thesis showed that elite athletes performing complex tasks were able to adapt their movements in the preparatory phase and complete good quality dives under more varied take-off conditions. This finding signals some significant practical implications for athletes, coaches and sports scientists. As such, it is recommended that care should be taken by coaches when designing practice tasks since the clear implication is that athletes need to practice adapting movement patterns during ongoing regulation of multi-articular coordination tasks. For example, volleyball servers can adapt to small variations in the ball toss phase, long jumpers can visually regulate gait as they prepare for the take-off, and springboard divers need to continue to practice adapting their take-off from the hurdle step. In summary, the studies of this programme of work have confirmed that the task constraints of training environments in elite sport performance programmes need to provide a faithful simulation of a competitive performance environment in order that performance outcomes may be stabilised with practice. Further, it is apparent that training environments can be enhanced by ensuring the representative design of task constraints, which have high action fidelity with the performance context. Ultimately, this study recommends that the traditional coaching adage 'perfect practice makes perfect", be reconsidered; instead advocating that practice should be, as Bernstein (1967) suggested, "repetition without repetition".
Resumo:
Voltage unbalance is a major power quality problem in low voltage residential feeders due to the random location and rating of single-phase rooftop photovoltaic cells (PV). In this paper, two different improvement methods based on the application of series (DVR) and parallel (DSTATCOM) custom power devices are investigated to improve the voltage unbalance problem in these feeders. First, based on the load flow analysis carried out in MATLAB, the effectiveness of these two custom power devices is studied vis-à-vis the voltage unbalance reduction in urban and semi-urban/rural feeders containing rooftop PVs. Their effectiveness is studied from the installation location and rating points of view. Later, a Monte Carlo based stochastic analysis is carried out to investigate their efficacy for different uncertainties of load and PV rating and location in the network. After the numerical analyses, a converter topology and control algorithm is proposed for the DSTATCOM and DVR for balancing the network voltage at their point of common coupling. A state feedback control, based on pole-shift technique, is developed to regulate the voltage in the output of the DSTATCOM and DVR converters such that the voltage balancing is achieved in the network. The dynamic feasibility of voltage unbalance and profile improvement in LV feeders, by the proposed structure and control algorithm for the DSTATCOM and DVR, is verified through detailed PSCAD/EMTDC simulations.
Resumo:
Live migration of multiple Virtual Machines (VMs) has become an indispensible management activity in datacenters for application performance, load balancing, server consolidation. While state-of-the-art live VM migration strategies focus on the improvement of the migration performance of a single VM, little attention has been given to the case of multiple VMs migration. Moreover, existing works on live VM migration ignore the inter-VM dependencies, and underlying network topology and its bandwidth. Different sequences of migration and different allocations of bandwidth result in different total migration times and total migration downtimes. This paper concentrates on developing a multiple VMs migration scheduling algorithm such that the performance of migration is maximized. We evaluate our proposed algorithm through simulation. The simulation results show that our proposed algorithm can migrate multiple VMs on any datacenter with minimum total migration time and total migration downtime.
Resumo:
This article studies the problem of transforming a process model with an arbitrary topology into an equivalent well-structured process model. While this problem has received significant attention, there is still no full characterization of the class of unstructured process models that can be transformed into well-structured ones, nor an automated method for structuring any process model that belongs to this class. This article fills this gap in the context of acyclic process models. The article defines a necessary and sufficient condition for an unstructured acyclic process model to have an equivalent well-structured process model under fully concurrent bisimulation, as well as a complete structuring method. The method has been implemented as a tool that takes process models captured in the BPMN and EPC notations as input. The article also reports on an empirical evaluation of the structuring method using a repository of process models from commercial practice.
Resumo:
This article addresses the problem of estimating the Quality of Service (QoS) of a composite service given the QoS of the services participating in the composition. Previous solutions to this problem impose restrictions on the topology of the orchestration models, limiting their applicability to well-structured orchestration models for example. This article lifts these restrictions by proposing a method for aggregate QoS computation that deals with more general types of unstructured orchestration models. The applicability and scalability of the proposed method are validated using a collection of models from industrial practice.
Resumo:
This paper addresses the problem of transforming a process model with an arbitrary topology into an equivalent well-structured process model. While this problem has received significant attention, there is still no full characterization of the class of unstructured process models that can be transformed into well-structured ones, nor an automated method to structure any process model that belongs to this class. This paper fills this gap in the context of acyclic process models. The paper defines a necessary and sufficient condition for an unstructured process model to have an equivalent structured model under fully concurrent bisimulation, as well as a complete structuring method.
Resumo:
Interfacing converters used in connecting energy storage systems like supercapacitors and battery banks to wind power systems introduce additional cost and power losses. This paper therefore presents a direct integration scheme for supercapacitors used in mitigating short-term power fluctuations in wind power systems. This scheme uses a dual inverter topology for both grid connection and interfacing a supercapacitor bank. The main inverter of the dual inverter system is powered by the rectified output of a wind turbine-coupled permanent-magnet synchronous generator. The auxiliary inverter is directly connected to the supercapacitor bank. With this approach, an interfacing converter is not required, and there are no associated costs and power losses incurred. The operation of the proposed system is discussed in detail. Simulation and experimental results are presented to verify the efficacy of the proposed system in suppressing short-term wind power fluctuations.
Resumo:
A robust and reliable grid power interface system for wind turbines using a permanent-magnet synchronous generator (PMSG) is proposed in this paper, where an integration of a generator-side three-switch buck-type rectifier and a grid-side Z-source inverter is employed as a bridge between the generator and the grid. The modulation strategy for the proposed topology is developed from space-vector modulation and Z-source network operation principles. Two PMSG control methods, namely, unity-power-factor control and rotor-flux-orientation control (Id = 0), are studied to establish an optimized control scheme for the generator-side three-switch buck-type rectifier. The system control scheme decouples active- and reactive-power control through voltage-oriented control and optimizes PMSG control for the grid- and generator-side converters independently. Maximum power point tracking is implemented by adjusting the shoot-through duty cycles of the Z-source network. The design considerations of the passive components are also provided. The performances and practicalities of the designed architecture have been verified by simulations and experiments.
Resumo:
For the renewable energy sources whose outputs vary continuously, a Z-source current-type inverter has been proposed as a possible buck-boost alternative for grid-interfacing. With a unique X-shaped LC network connected between its dc power source and inverter topology, Z-source current-type inverter is however expected to suffer from compounded resonant complications in addition to those associated with its second-order output filter. To improve its damping performance, this paper proposes the careful integration of Posicast or three-step compensators before the inverter pulse-width modulator for damping triggered resonant oscillations. In total, two compensators are needed for wave-shaping the inverter boost factor and modulation ratio, and they can conveniently be implemented using first-in first-out stacks and embedded timers of modern digital signal processors widely used in motion control applications. Both techniques are found to damp resonance of ac filter well, but for cases of transiting from current-buck to boost state, three-step technique is less effective due to the sudden intermediate discharging interval introduced by its non-monotonic stepping (unlike the monotonic stepping of Posicast damping). These findings have been confirmed both in simulations and experiments using an implemented laboratory prototype.
Resumo:
To overcome the limitations of existing gate drive topologies an improved gate drive concept is proposed to provide fast, controlled switching of power MOSFETs. The proposed topology exploits the cascode configuration with the inclusion of an active gate clamp to ensure that the driven MOSFET may be turned off under all load conditions. Key operating principles and advantages of the proposed gate drive topology are discussed. Characteristic waveforms are investigated via simulation and experimentation for the cascode driver in an inductive switching application at 375V and 10A. Experimental waveforms compared well with simulations with long gate charging delays (including the Miller plateau) being eliminated from the gate voltage waveform.
Resumo:
Typical Inductive Power Transfer (IPT) systems employ two power conversion stages to generate a high frequency current from low frequency utility supply. This paper proposes a matrix converter based IPT system that facilitates the generation of high frequency current through a single power conversion stage. The proposed matrix converter topology transforms a 3-phase low frequency voltage system to a high frequency single phase voltage which in turn powers a series compensated IPT system. A comprehensive mathematical model is developed to investigate the behavior of the proposed IPT topology. Theoretical results are presented in comparison to simulations, which are performed in Matlab/ Simulink, to demonstrate the applicability of the proposed concept and the validity of the developed model.
Resumo:
A Three-Phase Nine-Switch Converter (NSC) topology for Doubly Fed Induction Generator in wind energy generation is proposed in this paper. This converter topology was used in various applications such as Hybrid Electric Vehicles and Uninterruptable Power Supplies. In this paper, Nine-Switch Converter is introduced in Doubly Fed Induction Generator in renewable energy application for the first time. It replaces the conventional Back-to-Back Pulse Width Modulated voltage source converter (VSC) which composed of twelve switches in many DFIG applications. Reduction in number of switches is the most beneficial in terms of cost and power switching losses. The operation principle of Nine-Switch Converter using SPWM method is discussed. The resulting NSC performance of rotor side current control, active power and reactive control are compared with Back-to Back voltage source converter performance. DC link voltage regulation using front end converter is also presented. Finally the simulation results of DFIG performances using NSC and Back-to-Back VSC are analyzed and compared.
Resumo:
Throughout a lifetime of operation, a mobile service robot needs to acquire, store and update its knowledge of a working environment. This includes the ability to identify and track objects in different places, as well as using this information for interaction with humans. This paper introduces a long-term updating mechanism, inspired by the modal model of human memory, to enable a mobile robot to maintain its knowledge of a changing environment. The memory model is integrated with a hybrid map that represents the global topology and local geometry of the environment, as well as the respective 3D location of objects. We aim to enable the robot to use this knowledge to help humans by suggesting the most likely locations of specific objects in its map. An experiment using omni-directional vision demonstrates the ability to track the movements of several objects in a dynamic environment over an extended period of time.
Resumo:
An offshore wind turbine usually has the grid step-up transformer integrated in the nacelle. This increases mechanical loading of the tower. In that context, a transformer-less, high voltage, highly-reliable and compact converter system for nacelle installation would be an attractive solution for large offshore wind turbines. This paper, therefore, presents a transformer-less grid integration topology for PMSG based large wind turbine generator systems using modular matrix converters. Each matrix converter module is fed from three generator coils of the PMSG which are phase shifted by 120°. Outputs of matrix converter modules are connected in series to increase the output voltage and thus eliminate the need of a coupling step-up transformer. Moreover, dc-link capacitors found in conventional back-to-back converter topologies are eliminated in the proposed system. Proper multilevel output voltage generation and power sharing between converter modules are achieved through an advanced switching strategy. Simulation results are presented to validate the proposed modular matrix converter system, modulation method and control techniques.