451 resultados para Space consumption
Resumo:
Piezoelectric polymers based on polyvinylidene fluoride (PVDF) are of interest for large aperture space-based telescopes. Dimensional adjustments of adaptive polymer films are achieved via charge deposition and require a detailed understanding of the piezoelectric material responses which are expected to suffer due to strong vacuum UV, gamma, X-ray, energetic particles and atomic oxygen under low earth orbit exposure conditions. The degradation of PVDF and its copolymers under various stress environments has been investigated. Initial radiation aging studies using gamma- and e-beam irradiation have shown complex material changes with significant crosslinking, lowered melting and Curie points (where observable), effects on crystallinity, but little influence on overall piezoelectric properties. Surprisingly, complex aging processes have also been observed in elevated temperature environments with annealing phenomena and cyclic stresses resulting in thermal depoling of domains. Overall materials performance appears to be governed by a combination of chemical and physical degradation processes. Molecular changes are primarily induced via radiative damage, and physical damage from temperature and AO exposure is evident as depoling and surface erosion. Major differences between individual copolymers have been observed providing feedback on material selection strategies.
Resumo:
Background Interdialytic weight gain (IDWG) can be reduced by lowering the dialysate sodium concentration ([Na]) in haemodialysis patients. It has been assumed that this is because thirst is reduced, although this has been difficult to prove. We compared thirst patterns in stable haemodialysis patients with high and low IDWG using a novel technique and compared the effect of low sodium dialysis (LSD) with normal sodium dialysis (NSD). Methods Eight patients with initial high IDWG and seven with low IDWG completed hourly visual analogue ratings of thirst using a modified palmtop computer during the dialysis day and the interdialytic day. The dialysate [Na] was progressively reduced by up to 5 mmol/l over five treatments. Dialysis continued at the lowest attained [Na] for 2 weeks and the measurements were repeated. The dialysate [Na] then returned to baseline and the process was repeated. Results Baseline interdialytic day mean thirst was higher than the dialysis day mean for the high IDWG group (49.9±14.0 vs 36.2±16.6) and higher than the low weight gain group (49.9±14.0 vs 34.1±14.6). This trend persisted on LSD, but there was a pronounced increase in post-dialysis thirst scores for both groups (high IDWG: 46±13 vs 30±21; low IDWG: 48±24 vs 33±18). The high IDWG group demonstrated lower IDWG during LSD than NSD (2.23±0.98 vs 2.86±0.38 kg; P<0.05). Conclusions Our results indicate that patients with high IDWG experience more intense feelings of thirst on the interdialytic day. LSD reduces their IDWG, but paradoxically increases thirst in the immediate post-dialysis period.
Resumo:
The focus of this paper questions how the performance place was transformed to a performance space. This major change in distinction holds an ongoing significance to the development of the actors, scenographers, animators, writers and film directors craft within current digitally mediated and interactive performance environments. As part of this discussion this paper traces the crucial seed of the revolution that transformed modern scenographic practice from the droll of the romantic realism of the Victorian stage to the open potential of the performance environment of today. This is achieved through close readings on the practical work of Edward Gordon Craig and Adolphe Appia as well as the scenographic discussions of Chris Baugh.
Resumo:
Presentation about information modelling and artificial intelligence, semantic structure, cognitive processing and quantum theory.
Resumo:
The collective purpose of these two studies was to determine a link between the V02 slow component and the muscle activation patterns that occur during cycling. Six, male subjects performed an incremental cycle ergometer exercise test to determine asub-TvENT (i.e. 80% of TvENT) and supra-TvENT (TvENT + 0.75*(V02 max - TvENT) work load. These two constant work loads were subsequently performed on either three or four occasions for 8 mins each, with V02 captured on a breath-by-breath basis for every test, and EMO of eight major leg muscles collected on one occasion. EMG was collected for the first 10 s of every 30 s period, except for the very first 10 s period. The V02 data was interpolated, time aligned, averaged and smoothed for both intensities. Three models were then fitted to the V02 data to determine the kinetics responses. One of these models was mono-exponential, while the other two were biexponential. A second time delay parameter was the only difference between the two bi-exponential models. An F-test was used to determine significance between the biexponential models using the residual sum of squares term for each model. EMO was integrated to obtain one value for each 10 s period, per muscle. The EMG data was analysed by a two-way repeated measures ANOV A. A correlation was also used to determine significance between V02 and IEMG. The V02 data during the sub-TvENT intensity was best described by a mono-exponential response. In contrast, during supra-TvENT exercise the two bi-exponential models best described the V02 data. The resultant F-test revealed no significant difference between the two models and therefore demonstrated that the slow component was not delayed relative to the onset of the primary component. Furthermore, only two parameters were deemed to be significantly different based upon the two models. This is in contrast to other findings. The EMG data, for most muscles, appeared to follow the same pattern as V02 during both intensities of exercise. On most occasions, the correlation coefficient demonstrated significance. Although some muscles demonstrated the same relative increase in IEMO based upon increases in intensity and duration, it cannot be assumed that these muscles increase their contribution to V02 in a similar fashion. Larger muscles with a higher percentage of type II muscle fibres would have a larger increase in V02 over the same increase in intensity.