281 resultados para Reactive power control
Resumo:
Decentralized and regional load-frequency control of power systems operating in normal and near-normal conditions has been well studied; and several analysis/synthesis approaches have been developed during the last few decades. However in contingency and off-normal conditions, the existing emergency control plans, such as under-frequency load shedding, are usually applied in a centralized structure using a different analysis model. This paper discusses the feasibility of using frequency-based emergency control schemes based on tie-line measurements and local information available within a control area. The conventional load-frequency control model is generalized by considering the dynamics of emergency control/protection schemes and an analytic approach to analyze the regional frequency response under normal and emergency conditions is presented.
Resumo:
Understanding micropolitics has become an important part of understanding leadership and power relations within schools. In this paper we review some of the pertinent literature and writing in the field, particularly as it relates to school leadership. Drawing on a couple of existing models, we present a new model that highlights three central power-based leadership approaches—‘power with’, ‘power through’ and ‘power over’. We put forward two contrasting vignettes that reveal a variety of micropolitical strategies used by school principals in the governance of their schools. These strategies range from favouritism and control at one end to empowerment and collaboration at the other. The vignettes are analysed in the light of the model and micropolitical literature presented in this article.
Resumo:
This article was written in 1997. After a 2009 review the content was left mostly unchanged - apart from this re-written abstract, restructured headings and a table of contents. The article deals directly with professional registration of surveyors; but it also relates to government procurement of professional services. The issues include public service and professional ethics; setting of professional fees; quality assurance; official corruption; and professional recruitment, education and training. Debate on the Land Surveyors Act 1908 (Qld) and its amendments to 1916 occurred at a time when industrial unrest of the 1890s and common market principles of the new Commonwealth were fresh in peoples’ minds. Industrial issues led to a constitutional crisis in the Queensland’s then bicameral legislature and frustrated a first attempt to pass a Surveyors Bill in 1907. The Bill was re-introduced in 1908 after fresh elections and Kidston’s return as state premier. Co-ordinated immigration and land settlement polices of the colonies were discontinued when the Commonwealth gained power over immigration in 1901. Concerns shifted to protecting jobs from foreign competition. Debate on 1974 amendments to the Act reflected concerns about skill shortages and professional accreditation. However, in times of economic downturn, a so-called ‘chronic shortage of surveyors’ could rapidly degenerate into oversupply and unemployment. Theorists championed a naïve ‘capture theory’ where the professions captured governments to create legislative barriers to entry to the professions. Supposedly, this allowed rent-seeking and monopoly profits through lack of competition. However, historical evidence suggests that governments have been capable of capturing and exploiting surveyors. More enlightened institutional arrangements are needed if the community is to receive benefits commensurate with sizable co-investments of public and private resources in developing human capital.
Resumo:
In the region of self-organized criticality (SOC) interdependency between multi-agent system components exists and slight changes in near-neighbor interactions can break the balance of equally poised options leading to transitions in system order. In this region, frequency of events of differing magnitudes exhibits a power law distribution. The aim of this paper was to investigate whether a power law distribution characterized attacker-defender interactions in team sports. For this purpose we observed attacker and defender in a dyadic sub-phase of rugby union near the try line. Videogrammetry was used to capture players’ motion over time as player locations were digitized. Power laws were calculated for the rate of change of players’ relative position. Data revealed that three emergent patterns from dyadic system interactions (i.e., try; unsuccessful tackle; effective tackle) displayed a power law distribution. Results suggested that pattern forming dynamics dyads in rugby union exhibited SOC. It was concluded that rugby union dyads evolve in SOC regions suggesting that players’ decisions and actions are governed by local interactions rules.
Resumo:
This paper presents dynamic hysteresis band height control to reduce the overshoot and undershoot issue on output voltage caused by load change. The converters in this study are Boost and Positive Buck-Boost (PBB) converters. PBB has been controlled to work in a step up conversion and avoid overshoot when load is changed. Simulation and experimental results have been presented to verify the proposed method.
Resumo:
Workflow Management Systems (WfMSs) enable the development and maintenance of workflow specifications at design time and their execution and monitoring at runtime. The open source WfMS YAWL supports the YAWL language – a formally defined language based on Petri nets which offers comprehensive support for control-flow and resource patterns. In addition, the YAWL system provides extensive support for process flexibility, in particular for process configuration, exception handling, dynamic workflow and declarative workflow. Due to its formal foundation, sophisticated verification support can also be achieved. This paper presents the YAWL system and its main applications.
Resumo:
This research investigated underlying issues that were critical to the success of the bifocal trial and comprised of three studies. The first study evaluated if Chinese-Canadian children were suitable subjects for the bifocal trial. The high prevalence of myopia in Chinese children suggests that genetic input plays a role in myopia development, but the rapid increase in prevalence over the last few decades indicates environmental factors are also important. Since this bifocal trial was conducted in Canada, this work aimed to determine whether Chinese children who had migrated to Canada would still have high myopia prevalence and a high rate of myopia progression. The second study determined the optimal bifocal lens power for myopia treatment and the effect of incorporating base-in prism into the bifocal. In the majority of published myopia control studies, the power of the prescribed near addition was usually predetermined in the belief that the near addition would always help to improve the near focus. In fact, the effect of near addition on the accommodative error might be quite different even for individuals in which the same magnitude of accommodation lag had been measured. Therefore, this work was necessary to guide the selection of bifocal and prism powers most suitable for the subsequent bifocal trial. The third study, the ultimate goal of this research, was to conduct a longitudinal clinical trial to determine if bifocals and prismatic bifocals could control myopia progression in children.
Resumo:
This paper proposes a method of enhancing system stability with a distribution static compensator (DSTATCOM) in an autonomous microgrid with multiple distributed generators (DG). It is assumed that there are both inertial and non-inertial DGs connected to the microgrid. The inertial DG can be a synchronous machine of smaller rating while inertia less DGs (solar) are assumed as DC sources. The inertia less DGs are connected through Voltage Source Converter (VSC) to the microgrid. The VSCs are controlled by either state feedback or current feedback mode to achieve desired voltage-current or power outputs respectively. The power sharing among the DGs is achieved by drooping voltage angle. Once the reference for the output voltage magnitude and angle is calculated from the droop, state feedback controllers are used to track the reference. The angle reference for the synchronous machine is compared with the output voltage angle of the machine and the error is fed to a PI controller. The controller output is used to set the power reference of the synchronous machine. The rate of change in the angle in a synchronous machine is restricted by the machine inertia and to mimic this nature, the rate of change in the VSCs angles are restricted by a derivative feedback in the droop control. The connected distribution static compensator (DSTATCOM) provides ride through capability during power imbalance in the microgrid, especially when the stored energy of the inertial DG is not sufficient to maintain stability. The inclusion of the DSATCOM in such cases ensures the system stability. The efficacies of the controllers are established through extensive simulation studies using PSCAD.
Resumo:
Multi-output boost (MOB) converter is a novel DC-DC converter unlike the regular boost converter, has the ability to share its total output voltage and to have different series output voltage from a given duty cycle for low and high power applications. In this paper, discrete voltage control with inner hysteresis current control loop has been proposed to keep the simplicity of the control law for the double-output MOB converter, which can be implemented by a combination of analogue and logical ICs or simple microcontroller to constrain the output voltages of MOB converter at their reference voltages against variation in load or input voltage. The salient features of the proposed control strategy are simplicity of implementation and ease to extend to multiple outputs in the MOB converter. Simulation and experimental results are presented to show the validity of control strategy.
Resumo:
A high voltage pulsed power supply is proposed in this paper based on oscillation between an inductor and a capacitor in an LC circuit. A two-leg resonant circuit, supplied through an inverter with an alternative voltage waveform, can generate output voltage up to four times an input voltage magnitude. Bipolar and unipolar modulations are used in a single phase inverter to analyse their effects on the proposed resonant converter. Simulations have been carried out to evaluate the proposed topology and control.
Resumo:
This paper presents a high voltage pulsed power system based on low voltage switch-capacitor units connected to a current source for several applications such as plasma systems. A buck-boost converter topology is used to utilize the current source and a series of low voltage switch-capacitor units is connected to the current source in order to provide high voltage with high voltage stress (dv/dt) as demanded by loads. This pulsed power converter is flexible in terms of energy control, in that the stored energy in the current source can be adjusted by changing the current magnitude to significantly improve the efficiency of various systems with different requirements. Output voltage magnitude and stress (dv/dt) can be controlled by a proper selection of components and control algorithm to turn on and off switching devices.