259 resultados para MR cardiac images
Resumo:
Aims: To determine whether incorporation of patient peer supporters in a Cardiac-Diabetes Self-Management Program (Peer-CDSMP) led to greater improvement in self-efficacy, knowledge and self-management behaviour in the intervention group compared to a control group. Background: Promoting improved self-management for those with diabetes and a cardiac condition is enhanced by raising motivation and providing a model. Peer support from former patients who are able to successfully manage similar conditions could enhance patient motivation to achieve better health outcomes and provide a model of how such management can be achieved. While studies on peer support have demonstrated the potential of peers in promoting self-management, none have examined the impact on patients with two comorbidities. Methods: A randomised controlled trial was used to develop and evaluate the effectiveness of the Peer-CDSMP from August 2009 to December 2010. Thirty cardiac patients with type 2 diabetes were recruited. The study commenced in an acute hospital, follow up at participants’ homes in Brisbane Australia. Results: While both the control and intervention groups had improved self-care behaviour, self-efficacy and knowledge, the improvement in knowledge was significantly greater for the intervention group. Conclusions: Significant improvement in knowledge was achieved for the intervention group. Absence of significant improvements in self-efficacy and self-care behaviour represents an inconclusive effect; further studies with larger sample sizes are recommended.
Resumo:
Background: Timely access to appropriate cardiac care is critical for optimising outcomes. Our aim was to derive an objective, comparable, geographic measure reflecting access to cardiac services for Australia's 20,387 population locations. Methods: An expert panel defined a single patient care pathway. Using geographic information systems (GIS) the numeric/alpha index was modelled in two phases. The acute phase index (numeric) ranged from 1 (access to tertiary centre with PCI ≤1 h) to 8 (no ambulance service, >3 h to medical facility, air transport required). The aftercare index was modelled into 5 alphabetic categories; A (Access to general practitioner, pharmacy, cardiac rehabilitation, pathology ≤1 h) to E (no services available within 1 h). Results: Approximately 70% or 13.9 million people lived within a CardiacARIAindex category 1A location. Disparity continues in access to category 1A cardiac services for 5.8 million (30%) of all Australians, 60% of Aboriginal and Torres Strait Islander people and 32% of people over 65 years of age. In a cardiac emergency only 40% of the Indigenous population reside within one hour of category 1 hospital. Approximately 30% (81,491 Indigenous persons) are more than one to three hours from basic cardiac services. Conclusion: Geographically, the majority of Australian's have timely access for survival of a cardiac event. The CardiacARIAindex objectively demonstrates that the healthcare system may not be providing for the needs of 60% of Indigenous people residing outside the 1A geographic radius. Innovative clinical practice maybe required to address these disparities.
Resumo:
Background/aims: Access to appropriate health care following an acute cardiac event is important for positive outcomes. The aim of the Cardiac ARIA index was to derive an objective, comparable, geographic measure reflecting access to cardiac services across Australia. Methods: Geographic Information Systems (GIS) were used to model a numeric-alpha index based on acute management from onset of symptoms to return to the community. Acute time frames have been calculated to include time for ambulance to arrive, assess and load patient, and travel to facility by road 40–80 kph. Results: The acute phase of the index was modelled into five categories: 1 [24/7 percutaneous cardiac intervention (PCI) ≤1 h]; 2 [24/7 PCI 1–3 h, and PCI less than an additional hour to nearest accident and emergency room (A&E)]: 3 [Nearest A&E ≤3 h (no 24/7 PCI within an extra hour)]: 4 [Nearest A&E 3–12 h (no 24/7 PCI within an extra hour)]: 5 [Nearest A&E 12–24 h (no 24/7 PCI within an extra hour)]. Discharge care was modelled into three categories based on time to a cardiac rehabilitation program, retail pharmacy, pathology services, hospital, GP or remote clinic: (A) all services ≤30 min; (B) >30 min and ≤60 min; (C) >60 min. Examples of the index indicate that the majority of population locations within capital cities were category 1A; Alice Springs and Byron Bay were 3A; and the Northern Territory town of Maningrida had minimal access to cardiac services with an index ranking of 5C. Conclusion: The Cardiac ARIA index provides an invaluable tool to inform appropriate strategies for the use of scarce cardiac resources.
Resumo:
Background: There are inequalities in geographical access and delivery of health care services in Australia, particularly for cardiovascular disease (CVD), Australia's major cause of death. Analyses and models that can inform and positively influence strategies to augment services and preventative measures are needed. The Cardiac-ARIA project is using geographical spatial technology (GIS) to develop a national index for each of Australia's 13,000 population centres. The index will describe the spatial distribution of CVD health care services available to support populations at risk, in a timely manner, after a major cardiac event. Methods: In the initial phase of the project, an expert panel of cardiologists and an emergency physician have identified key elements of national and international guidelines for management of acute coronary syndromes, cardiac arrest, life-threatening arrhythmias and acute heart failure, from the time of onset (potentially dial 000) to return from the hospital to the community (cardiac rehabilitation). Results: A systematic search has been undertaken to identify the geographical location of, and type of, cardiac services currently available. This has enabled derivation of a master dataset of necessary services, e.g. telephone networks, ambulance, RFDS, helicopter retrieval services, road networks, hospitals, general practitioners, medical community centres, pathology services, CCUs, catheterisation laboratories, cardio-thoracic surgery units and cardiac rehabilitation services. Conclusion: This unique and innovative project has the potential to deliver a powerful tool to both highlight and combat the burden of disease of CVD in urban and regional Australia.
Resumo:
Background/aims: Cardiovascular disease (CVD) continues to impose a heavy burden in terms of cost, disability and death in Australia. Recent evidence suggests that increasing remoteness, where cardiac services are scarce, is linked to an increased risk of dying from CVD. Fatal CVD events are reported to be between 20% and 50% higher in rural areas compared to major cities. Method: This project, with its extensive use of Geographic Information Systems (GIS) technology, will rank 11,338 rural and remote population centres to identify geographical ‘hotspots’ where there is likely to be a mismatch between the demand for and actual provision of cardiovascular services. It will, therefore, guide more equitable provision of services to rural and remote communities. Outcomes: The CARDIAC-ARIA project is designed to; map the type and location of cardiovascular services currently available in Australia, relative to the distribution of individuals who currently have symptomatic CVD; determine, by expert panel, what are the minimal requirements for comprehensive cardiovascular health support in metropolitan and rural communities and derive a rating classification based on the Accessibility and Remoteness Index of Australia (ARIA) for each of Australia's 11,338 rural and remote population centres. Conclusion: This unique, innovative and highly collaborative project has the potential to deliver a powerful tool to highlight and combat the burden imposed by cardiovascular disease (CVD) in Australia.
Resumo:
Volume measurements are useful in many branches of science and medicine. They are usually accomplished by acquiring a sequence of cross sectional images through the object using an appropriate scanning modality, for example x-ray computed tomography (CT), magnetic resonance (MR) or ultrasound (US). In the cases of CT and MR, a dividing cubes algorithm can be used to describe the surface as a triangle mesh. However, such algorithms are not suitable for US data, especially when the image sequence is multiplanar (as it usually is). This problem may be overcome by manually tracing regions of interest (ROIs) on the registered multiplanar images and connecting the points into a triangular mesh. In this paper we describe and evaluate a new discreet form of Gauss’ theorem which enables the calculation of the volume of any enclosed surface described by a triangular mesh. The volume is calculated by summing the vector product of the centroid, area and normal of each surface triangle. The algorithm was tested on computer-generated objects, US-scanned balloons, livers and kidneys and CT-scanned clay rocks. The results, expressed as the mean percentage difference ± one standard deviation were 1.2 ± 2.3, 5.5 ± 4.7, 3.0 ± 3.2 and −1.2 ± 3.2% for balloons, livers, kidneys and rocks respectively. The results compare favourably with other volume estimation methods such as planimetry and tetrahedral decomposition.
Resumo:
A system is described for calculating volume from a sequence of multiplanar 2D ultrasound images. Ultrasound images are captured using a video digitising card (Hauppauge Win/TV card) installed in a personal computer, and regions of interest transformed into 3D space using position and orientation data obtained from an electromagnetic device (Polbemus, Fastrak). The accuracy of the system was assessed by scanning 10 water filled balloons (13-141 ml), 10 kidneys (147 200 ml) and 16 fetal livers (8 37 ml) in water using an Acuson 128XP/10 (5 MHz curvilinear probe). Volume was calculated using the ellipsoid, planimetry, tetrahedral and ray tracing methods and compared with the actual volume measured by weighing (balloons) and water displacement (kidneys and livers). The mean percentage error for the ray tracing method was 0.9 ± 2.4%, 2.7 ± 2.3%, 6.6 ± 5.4% for balloons, kidneys and livers, respectively. So far the system has been used clinically to scan fetal livers and lungs, neonate brain ventricles and adult prostate glands.
Resumo:
A new system is described for estimating volume from a series of multiplanar 2D ultrasound images. Ultrasound images are captured using a personal computer video digitizing card and an electromagnetic localization system is used to record the pose of the ultrasound images. The accuracy of the system was assessed by scanning four groups of ten cadaveric kidneys on four different ultrasound machines. Scan image planes were oriented either radially, in parallel or slanted at 30 C to the vertical. The cross-sectional images of the kidneys were traced using a mouse and the outline points transformed to 3D space using the Fastrak position and orientation data. Points on adjacent region of interest outlines were connected to form a triangle mesh and the volume of the kidneys estimated using the ellipsoid, planimetry, tetrahedral and ray tracing methods. There was little difference between the results for the different scan techniques or volume estimation algorithms, although, perhaps as expected, the ellipsoid results were the least precise. For radial scanning and ray tracing, the mean and standard deviation of the percentage errors for the four different machines were as follows: Hitachi EUB-240, −3.0 ± 2.7%; Tosbee RM3, −0.1 ± 2.3%; Hitachi EUB-415, 0.2 ± 2.3%; Acuson, 2.7 ± 2.3%.
Resumo:
Sixteen formalin-fixed foetal livers were scanned in vitro using a new system for estimating volume from a sequence of multiplanar 2D ultrasound images. Three different scan techniques were used (radial, parallel and slanted) and four volume estimation algorithms (ellipsoid, planimetry, tetrahedral and ray tracing). Actual liver volumes were measured by water displacement. Twelve of the sixteen livers also received x-ray computed tomography (CT) and magnetic resonance (MR) scans and the volumes were calculated using voxel counting and planimetry. The percentage accuracy (mean ± SD) was 5.3 ± 4.7%, −3.1 ± 9.6% and −0.03 ± 9.7% for ultrasound (radial scans, ray volumes), MR and CT (voxel counting) respectively. The new system may be useful for accurately estimating foetal liver volume in utero.
Resumo:
Several track-before-detection approaches for image based aircraft detection have recently been examined in an important automated aircraft collision detection application. A particularly popular approach is a two stage processing paradigm which involves: a morphological spatial filter stage (which aims to emphasize the visual characteristics of targets) followed by a temporal or track filter stage (which aims to emphasize the temporal characteristics of targets). In this paper, we proposed new spot detection techniques for this two stage processing paradigm that fuse together raw and morphological images or fuse together various different morphological images (we call these approaches morphological reinforcement). On the basis of flight test data, the proposed morphological reinforcement operations are shown to offer superior signal to-noise characteristics when compared to standard spatial filter options (such as the close-minus-open and adaptive contour morphological operations). However, system operation characterised curves, which examine detection verses false alarm characteristics after both processing stages, illustrate that system performance is very data dependent.
Resumo:
Background Despite its efficacy and cost-effectiveness, exercise-based cardiac rehabilitation is undertaken by less than one-third of clinically eligible cardiac patients in every country for which data is available. Reasons for non-participation include the unavailability of hospital-based rehabilitation programs, or excessive travel time and distance. For this reason, there have been calls for the development of more flexible alternatives. Methodology and Principal Findings We developed a system to enable walking-based cardiac rehabilitation in which the patient's single-lead ECG, heart rate, GPS-based speed and location are transmitted by a programmed smartphone to a secure server for real-time monitoring by a qualified exercise scientist. The feasibility of this approach was evaluated in 134 remotely-monitored exercise assessment and exercise sessions in cardiac patients unable to undertake hospital-based rehabilitation. Completion rates, rates of technical problems, detection of ECG changes, pre- and post-intervention six minute walk test (6 MWT), cardiac depression and Quality of Life (QOL) were key measures. The system was rated as easy and quick to use. It allowed participants to complete six weeks of exercise-based rehabilitation near their homes, worksites, or when travelling. The majority of sessions were completed without any technical problems, although periodic signal loss in areas of poor coverage was an occasional limitation. Several exercise and post-exercise ECG changes were detected. Participants showed improvements comparable to those reported for hospital-based programs, walking significantly further on the post-intervention 6 MWT, 637 m (95% CI: 565–726), than on the pre-test, 524 m (95% CI: 420–655), and reporting significantly reduced levels of cardiac depression and significantly improved physical health-related QOL. Conclusions and Significance The system provided a feasible and very flexible alternative form of supervised cardiac rehabilitation for those unable to access hospital-based programs, with the potential to address a well-recognised deficiency in health care provision in many countries. Future research should assess its longer-term efficacy, cost-effectiveness and safety in larger samples representing the spectrum of cardiac morbidity and severity.