134 resultados para Fracture fixation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study examines whether, in the presentation of financial information, digital formats address the concern over users’ functional fixation. The accounting literature indicates that the presentation of financial information either within the financial statements or in the notes to the financial statements often creates functional fixation where users of financial statements fail to adjust for differences in accounting policy. This leads users to judge what would otherwise be identical financial situations as being different due to the different accounting policies and methods adopted. It has been suggested that the use of digital formats in presenting financial reports may overcome functional fixation. Using an experimental design involving accountants in public practice, the results indicate that the use of digital formats to present financial reports does not fully overcome the issue of functional fixation in the processing of financial information. Although the participants were able to identify and extract relevant information, irrespective of whether or not the information was presented within the financial statements or in the notes to the accounts, the evidence indicates that functional fixation remained when the participants made final decisions based on available information. This suggests that functional fixation may not be caused by access to or extraction of information but by the level of perceived significance based on where the information is reported in the financial statements. In general, the results indicate that current technology may not be able to fully reduce functional fixation in the evaluation of financial information prepared in accordance with different accounting policies and methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Periprosthetic fractures are increasingly frequent. The fracture may be located over the shaft of the prosthesis, at its tip or below (21). The treatment of explosion fractures is difficult because the shaft blocks the application of implants, like screws, which need to penetrate the medullary cavity. The cerclage, as a simple periosteal loop, made of wire or more recently cable, does not only avoid the medullary cavity. Its centripetal mode of action is well suited for reducing and maintaining radially displaced fractures. Furthermore, the cerclage lends itself well for minimally invasive internal fixation. New insight challenges the disrepute of which the cerclage technology suffered for decades. The outcome of cerclage fixation benefits from an improved understanding of its technology, mechano-biology and periosteal blood supply. Preconceived and generally accepted opinions like "strangulation of blood supply" need to be re-examined. Recent mechanical evaluations (22) demonstrate that the wire application may be improved but cable is superior in hand- ling, maintenance of tension and strength. Beside the classical concepts of absolute and relative stability a defined stability condition needs consideration. It is typical for cerclage. Called "loose-lock stability" it specifies the situation where a loosened implant allows first unimpeded displacement changing abruptly into a locked fixation preventing further dislocation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Compound pelvic fractures are deemed to be one of the most severe orthopaedic injuries with an extremely high morbidity and mortality. After the initial resuscitation phase the prevention of pelvic sepsis is one of the main treatment goals for patients with an open pelvic fracture. If there is a suspicion of a rectal injury or if the wounds are in the perineal area, The Princess Alexandra Hospital's management plan includes early faecal diversion combined with vigorous soft tissue debridement, VAC(®) therapy and (if indicated) external fixation of the pelvic fracture. We present our flowchart for the treatment of trauma patients with compound pelvic fractures illustrated by a case report describing a 32 year old patient who sustained an open pelvic ring injury in a workplace accident. The aim of this paper is to underline the importance of a safe, straightforward approach to compound pelvic fractures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The finite element (FE) analysis is an effective method to study the strength and predict the fracture risk of endodontically-treated teeth. This paper presents a rapid method developed to generate a comprehensive tooth FE model using data retrieved from micro-computed tomography (μCT). With this method, the inhomogeneity of material properties of teeth was included into the model without dividing the tooth model into different regions. The material properties of the tooth were assumed to be related to the mineral density. The fracture risk at different tooth portions was assessed for root canal treatments. The micro-CT images of a tooth were processed by a Matlab software programme and the CT numbers were retrieved. The tooth contours were obtained with thresholding segmentation using Amira. The inner and outer surfaces of the tooth were imported into Solidworks and a three-dimensional (3D) tooth model was constructed. An assembly of the tooth model with the periodontal ligament (PDL) layer and surrounding bone was imported into ABAQUS. The material properties of the tooth were calculated from the retrieved CT numbers via ABAQUS user's subroutines. Three root canal geometries (original and two enlargements) were investigated. The proposed method in this study can generate detailed 3D finite element models of a tooth with different root canal enlargements and filling materials, and would be very useful for the assessment of the fracture risk at different tooth portions after root canal treatments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Distal tibial fractures are now commonly treated via intermedullary plate fixation due to higher rates of union and lower rates of postoperative complications. However, patient specific bone morphology demands manual deformation of the plate to ensure appropriate fit along the bone Distal tibial fractures are now commonly treated via intermedullary plate fixation due to higher rates of union and lower rates of postoperative complications. However, patient specific bone morphology demands manual deformation of the plate to ensure appropriate fit along the bone contours, and depending on the material of the plate, different outcomes have been reported along with postoperative complications. A comparative analysis of Stainless Steel 316L and Ti-6Al-4V alloys was carried to estimate the safe bending limit for appropriate fits. The results from the ANSYS FEA simulations were validated with experiments based on ASTM F382-99. It is found that SS316L is better suited for large deformations (up to 16˚ in proximal tip and 7.5˚ in distal end) and Ti for smaller deformation contours (up to 3˚ in proximal tip and 1.8˚ in distal end). The results of this study have profound implications for the choice of plates based on preliminary radiographical fracture examinations to ensure better fixation and higher rates of union of distal tibial fractures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Currently available volar locking plates for the treatment of distal radius fractures incorporate at least two distal screw rows for fixation of the metaphyseal fragment and have a variable-angle locking mechanism which allows placement of the screws in various directions There is, however no evidence that these plates translate into better outcomes or have superior biomechanical properties to first generation plates, which had a single distal screw row and fixed-angle locking. The aim of our biomechanical study was to compare fixed-angle single-row plates with variable-angle multi-row plates to clarify the optimal number of locking screws. MATERIALS AND METHODS: Five different plate-screw combinations of three different manufacturers were tested, each group consisting of five synthetic fourth generation distal radius bones. An AO type C2 fracture was created and the fractures were plated according to each manufacturer's recommendations. The specimens then underwent cyclic and load-to-failure testing. An optical motion analysis system was used to detect displacement of fragments. RESULTS: No significant differences were detected after cyclic loading as well as after load-to-failure testing, neither in regard to axial deformation, implant rigidity or maximum displacement. The fixed-angle single-row plate showed the highest pre-test rigidity, least increase in post-testing rigidity and highest load-to-failure rigidity and least radial shortening. The radial shortening of plates with two distal screw rows was 3.1 and 4.3 times higher, respectively, than that of the fixed-angle single-row plate. CONCLUSION: The results of our study indicate that two distal screw rows do not add to construct rigidity and resistance against loss of reduction. Well conducted clinical studies based on the findings of biomechanical studies are necessary to determine the optimal number of screws necessary to achieve reproducibly good results in the treatment of distal radius fractures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to perform a biomechanical analysis of the cement-in-cement (c-in-c) technique for fixation of selected Vancouver Type B1 femoral periprosthetic fractures and to assess the degree of cement interposition at the fracture site. Six embalmed cadaveric femora were implanted with a cemented femoral stem. Vancouver Type B1 fractures were created by applying a combined axial and rotational load to failure. The femora were repaired using the c-in-c technique and reloaded to failure. The mean primary fracture torque was 117 Nm (SD 16.6, range 89–133). The mean revision fracture torque was 50 Nm (SD 16.6, range 29–74), which is above the torque previously observed for activities of daily living. Cement interposition at the fracture site was found to be minimal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Different types of defects can be introduced into graphene during material synthesis, and significantly influence the properties of graphene. In this work, we investigated the effects of structural defects, edge functionalisation and reconstruction on the fracture strength and morphology of graphene by molecular dynamics simulations. The minimum energy path analysis was conducted to investigate the formation of Stone-Wales defects. We also employed out-of-plane perturbation and energy minimization principle to study the possi-ble morphology of graphene nanoribbons with edge-termination. Our numerical results show that the fracture strength of graphene is dependent on defects and environmental temperature. However, pre-existing defects may be healed, resulting in strength recovery. Edge functionalization can induce compressive stress and ripples in the edge areas of gra-phene nanoribbons. On the other hand, edge reconstruction contributed to the tensile stress and curved shape in the graphene nanoribbons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High energy bone fractures resulting from impact trauma are often accompanied by subcutaneous soft tissue injuries, even if the skin remains intact. There is evidence that such closed soft tissue injuries affect the healing of bone fractures, and vice versa. Despite this knowledge, most impact trauma studies in animals have focussed on bone fractures or soft tissue trauma in isolation. However, given the simultaneous impact on both tissues a better understanding of the interaction between these two injuries is necessary to optimise clinical treatment. The aim of this study was therefore to develop a new experimental model and characterise, for the first time, the healing of a complex fracture with concurrent closed soft tissue trauma in sheep. A pendulum impact device was designed to deliver a defined and standardised impact to the distal thigh of sheep, causing a reproducible contusion injury to the subcutaneous soft tissues. In a subsequent procedure, a reproducible femoral butterfly fracture (AO C3-type) was created at the sheep’s femur, which was initially stabilised for 5 days by an external fixator construct to allow for soft tissue swelling to recede, and ultimately in a bridging construct using locking plates. The combined injuries were applied to twelve sheep and the healing observed for four or eight weeks (six animals per group) until sacrifice. The pendulum impact led to a moderate to severe circumferential soft tissue injury with significant bruising, haematomas and partial muscle disruptions. Posttraumatic measurements showed elevated intra-compartmental pressure and circulatory tissue breakdown markers, with recovery to normal, pre-injury values within four days. Clinically, no neurovascular deficiencies were observed. Bi-weekly radiological analysis of the healing fractures showed progressive callus healing over time, with the average number of callus bridges increasing from 0.4 at two weeks to 4.2 at eight weeks. Biomechanical testing after sacrifice showed increasing torsional stiffness between four and eight weeks healing time from 10% to 100%, and increasing ultimate torsional strength from 10% to 64% (relative to the contralateral control limb). Our results demonstrate the robust healing of a complex femur fracture in the presence of a severe soft tissue contusion injury in sheep and demonstrate the establishment of a clinically relevant experimental model, for research aimed at improving the treatment of bone fractures accompanied by closed soft tissue injuries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: normal ageing processes impact on oropharyngeal swallowing function placing older adults at risk of developing oropharyngeal dysphagia (OD). Anecdotal clinical experience has observed that older patients recovering from hip fracture surgery commonly develop OD post-operatively. Objective: to document the presence of OD following hip fracture surgery, and the factors associated with OD. Methods: one hundred and eighty-one patients with a mean age of 83 years (range: 65–103) admitted to a specialised orthogeriatric unit were assessed for OD post-surgery for hip fracture. Pre-admission, intra-operative and post-operative factors were examined to determine their relationship with the presence of OD. Results: OD was found to be present post-operatively in 34% (n = 61) of the current population. Multivariate logistic regression analyses revealed the presence of pre-existing neurological and respiratory medical co-morbidities, presence of post-operative delirium, age and living in a residential aged care facility prior to hospital admission to be associated with the post-operative OD. Conclusion: these results highlight that OD is present in a large number of the older hip fracture population. Early identification of OD has important implications for the provision of timely dysphagia management that may prevent secondary complications and potentially reduce the hospital length of stay.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Different types of defects can be introduced into graphene during material synthesis, and significantly influence the properties of graphene. In this work, we investigated the effects of structural defects, edge functionalisation and reconstruction on the fracture strength and morphology of graphene by molecular dynamics simulations. The minimum energy path analysis was conducted to investigate the formation of Stone-Wales defects. We also employed out-of-plane perturbation and energy minimization principle to study the possible morphology of graphene nanoribbons with edge-termination. Our numerical results show that the fracture strength of graphene is dependent on defects and environmental temperature. However, pre-existing defects may be healed, resulting in strength recovery. Edge functionalization can induce compressive stress and ripples in the edge areas of graphene nanoribbons. On the other hand, edge reconstruction contributed to the tensile stress and curved shape in the graphene nanoribbons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Runt related transcription factor 2 (RUNX2) is a key regulator of osteoblast differentiation. Several variations within RUNX2 have been found to be associated with significant changes in BMD, which is a major risk factor for fracture. In this study we report that an 18bp deletion within the polyalanine tract (17A>11A) of RUNX2 is significantly associated with fracture. Carriers of the 11A allele were found to be nearly twice as likely to have sustained fracture. Within the fracture category, there was a significant tendency of 11A carriers to present with fractures of bones of intramembranous origin compared to bones of endochondral origin (p=0.005). In a population of random subjects, the 11A allele was associated with decreased levels of serum collagen cross links (CTx, p=0.01), suggesting decreased bone turnover. The transactivation function of the 11A allele was quantitatively decreased. Interestingly, we found no effect of the 11A allele on BMD at multiple skeletal sites, although these were not the sites where a relationship with fracture was most evident. These findings suggest that the 11A allele is a biologically relevant polymorphism that influences serum CTx and confers enhanced fracture risk in a site-selective manner related to intramembranous bone ossification.