188 resultados para Engineers in government
Resumo:
Faculty and reference librarians at the Queensland University of Technology have collaborated in an attempt to improve the quality of literature reviews in civil engineering final -year research projects. This article describes the instructional program devised and the level of faculty support for the librarians' contribution, and presents survey results revealing how students could most benefit from BI and how the classroom collaboration affected student project work. The authors offer some observations about the possible impact of 81 in general, and on engineers in particular, which may provide a focus for future research.
Resumo:
The importance of applying unsaturated soil mechanics to geotechnical engineering design has been well understood. However, the consumption of time and the necessity for a specific laboratory testing apparatus when measuring unsaturated soil properties have limited the application of unsaturated soil mechanics theories in practice. Although methods for predicting unsaturated soil properties have been developed, the verification of these methods for a wide range of soil types is required in order to increase the confidence of practicing engineers in using these methods. In this study, a new permeameter was developed to measure the hydraulic conductivity of unsaturated soils using the steady-state method and directly measured suction (negative pore-water pressure) values. The apparatus is instrumented with two tensiometers for the direct measurement of suction during the tests. The apparatus can be used to obtain the hydraulic conductivity function of sandy soil over a low suction range (0-10 kPa). Firstly, the repeatability of the unsaturated hydraulic conductivity measurement, using the new permeameter, was verified by conducting tests on two identical sandy soil specimens and obtaining similar results. The hydraulic conductivity functions of the two sandy soils were then measured during the drying and wetting processes of the soils. A significant hysteresis was observed when the hydraulic conductivity was plotted against the suction. However, the hysteresis effects were not apparent when the conductivity was plotted against the volumetric water content. Furthermore, the measured unsaturated hydraulic conductivity functions were compared with predictions using three different predictive methods that are widely incorporated into numerical software. The results suggest that these predictive methods are capable of capturing the measured behavior with reasonable agreement.
Resumo:
Service bundles, in the context of e-government, are used to group services together that relate to a certain citizen need. These bundles can then be presented on a governmental one-stop portal to structure the available service offerings according to citizen expectations. In order to ensure that citizens utilise the one-stop portal and comprised service bundles for future transactions, the quality of these service bundles needs to be managed and maximised accordingly. Consequently, models and tools that focus on assessing service bundle quality play an important role, when it comes to increasing or retaining usage behaviour of citizens. This study focuses on providing a rigorous and structured literature review of e-government outlets with regards to their coverage of service bundle quality and e-service quality themes. The study contributes to academia and practice by providing a framework that allows structuring and classifying existing studies relevant for the assessment of quality for government portals. Furthermore, this study provides insights into the status quo of quality models that can be used by governments to assess the quality of their service bundles. Directions for future research and limitations of the present study are provided as well.
Resumo:
In order to increase the accuracy of patient positioning for complex radiotherapy treatments various 3D imaging techniques have been developed. MegaVoltage Cone Beam CT (MVCBCT) can utilise existing hardware to implement a 3D imaging modality to aid patient positioning. MVCBCT has been investigated using an unmodified Elekta Precise linac and 15 iView amorphous silicon electronic portal imaging device (EPID). Two methods of delivery and acquisition have been investigated for imaging an anthropomorphic head phantom and quality assurance phantom. Phantom projections were successfully acquired and CT datasets reconstructed using both acquisition methods. Bone, tissue and air were 20 clearly resolvable in both phantoms even with low dose (22 MU) scans. The feasibility of MegaVoltage Cone beam CT was investigated using a standard linac, amorphous silicon EPID and a combination of a free open source reconstruction toolkit as well as custom in-house software written in Matlab. The resultant image quality has 25 been assessed and presented. Although bone, tissue and air were resolvable 2 in all scans, artifacts are present and scan doses are increased when compared with standard portal imaging. The feasibility of MVCBCT with unmodified Elekta Precise linac and EPID has been considered as well as the identification of possible areas for future development in artifact correction techniques to 30 further improve image quality.
Resumo:
Aim The aim of this paper was to explore the concept of expertise in nursing from the perspective of how it relates to current driving forces in health care in which it discusses the potential barriers to acceptance of nursing expertise in a climate in which quantification of value and cost containment run high on agendas. Background Expert nursing practice can be argued to be central to high quality, holistic, individualized patient care. However, changes in government policy which have led to the inception of comprehensive guidelines or protocols of care are in danger of relegating the ‘expert nurse’ to being an icon of the past. Indeed, it could be argued that expert nurses are an expensive commodity within the nursing workforce. Consequently, with this change to the use of clinical guidelines, it calls into question how expert nursing practice will develop within this framework of care. Method The article critically reviews the evidence related to the role of the Expert Nurse in an attempt to identify the key concepts and ideas, and how the inception of care protocols has implications for their role. Conclusion Nursing expertise which focuses on the provision of individualized, holistic care and is based largely on intuitive decision making cannot, should not be reduced to being articulated in positivist terms. However, the dominant power and decision-making focus in health care means that nurses must be confident in articulating the value of a concept which may be outside the scope of knowledge of those with whom they are debating. Relevance to clinical practice The principles of abduction or fuzzy logic may be useful in assisting nurses to explain in terms which others can comprehend, the value of nursing expertise.
Resumo:
Stereotactic radiosurgery treatments involve the delivery of very high doses for a small number of fractions. To date, there is limited data in terms of the skin dose for the very small field sizes used in these treatments. In this work, we determine relative surface doses for small size circular collimators as used in stereotactic radiosurgery treatments. Monte Carlo calculations were performed using the BEAMnrc code with a model of the Novalis 15 Trilogy linear accelerator and the BrainLab circular collimators. The surface doses were calculated at the ICRU skin dose depth of 70 m all using the 6 MV SRS x-ray beam. The calculated surface doses varied between 15 – 12% with decreasing values as the field size increased from 4 to 30 mm. In comparison, surface doses were measured using Gafchromic EBT3 film positioned at the surface of a Virtual Water phantom. The absolute agreement between calculated and measured surface doses was better than 2.5% which is well within the 20 uncertainties of the Monte Carlo calculations and the film measurements. Based on these results, we have shown that the Gafchromic EBT3 film is suitable for surface dose estimates in very small size fields as used in SRS.
Resumo:
One of the most important parts of any Bridge Management System (BMS) is the condition assessment and rating of bridges. This paper, introduces a procedure for condition assessment, based on criticality and vulnerability analysis. According to this procedure, new rating equations are developed. The inventory data is used to determine the contribution of different critical factors such as environmental effects, flood, earthquake, wind, and vehicle impacts. The criticality of the components to live load and vulnerability of the components to the above critical factors are identified. Based on the criticality and the vulnerability of the components and criticality of factors, and by using the new rating equations, the condition assessment and the rating of the railway bridges and their components at the network level will be conducted. This method for the first time incorporates structural analysis, available knowledge of risk assessment in structural engineering standards, and the experience of structural engineers in a practical way to enhance the reliability of the condition assessment and rating a network of bridges.
Resumo:
Conservation planning and management programs typically assume relatively homogeneous ecological landscapes. Such “ecoregions” serve multiple purposes: they support assessments of competing environmental values, reveal priorities for allocating scarce resources, and guide effective on-ground actions such as the acquisition of a protected area and habitat restoration. Ecoregions have evolved from a history of organism–environment interactions, and are delineated at the scale or level of detail required to support planning. Depending on the delineation method, scale, or purpose, they have been described as provinces, zones, systems, land units, classes, facets, domains, subregions, and ecological, biological, biogeographical, or environmental regions. In each case, they are essential to the development of conservation strategies and are embedded in government policies at multiple scales.
Resumo:
There have been substantial advances in small field dosimetry techniques and technologies, over the last decade, which have dramatically improved the achievable accuracy of small field dose measurements. This educational note aims to help radiation oncology medical physicists to apply some of these advances in clinical practice. The evaluation of a set of small field output factors (total scatter factors) is used to exemplify a detailed measurement and simulation procedure and as a basis for discussing the possible effects of simplifying that procedure. Field output factors were measured with an unshielded diode and a micro-ionisation chamber, at the centre of a set of square fields defined by a micro-multileaf collimator. Nominal field sizes investigated ranged from 6×6 to 98×98 mm2. Diode measurements in fields smaller than 30 mm across were corrected using response factors calculated using Monte Carlo simulations of the full diode geometry and daisy-chained to match micro-chamber measurements at intermediate field sizes. Diode measurements in fields smaller than 15 mm across were repeated twelve times over three separate measurement sessions, to evaluate the to evaluate the reproducibility of the radiation field size and its correspondence with the nominal field size. The five readings that contributed to each measurement on each day varied by up to 0.26%, for the “very small” fields smaller than 15 mm, and 0.18% for the fields larger than 15 mm. The diode response factors calculated for the unshielded diode agreed with previously published results, within 1.6%. The measured dimensions of the very small fields differed by up to 0.3 mm, across the different measurement sessions, contributing an uncertainty of up to 1.2% to the very small field output factors. The overall uncertainties in the field output factors were 1.8% for the very small fields and 1.1% for the fields larger than 15 mm across. Recommended steps for acquiring small field output factor measurements for use in radiotherapy treatment planning system beam configuration data are provided.
Resumo:
The understanding of the loads generated within the prosthetic leg can aid engineers in the design of components and clinicians in the process of rehabilitation. Traditional methods to assess these loads have relied on inverse dynamics. This indirect method estimates the applied load using video recordings and force-plates located at a distance from the region of interest, such as the base of the residuum. The well-known limitations of this method are related to the accuracy of this recursive model and the experimental conditions required (Frossard et al., 2003). Recent developments in sensors (Frossard et al., 2003) and prosthetic fixation (Brånemark et al., 2000) permit the direct measurement of the loads applied on the residuum of transfemoral amputees. In principle, direct measurement should be an appropriate tool for assessing the accuracy of inverse dynamics. The purpose of this paper is to determine the validity of this assumption. The comparative variable used in this study is the velocity of the relative body center of mass (VCOM(t)). The relativity is used to align the static (w.r.t. position) force plate measurement with the dynamic load cell measurement.
Resumo:
This book provides the first comprehensive international coverage of key issues in mandatory reporting of child abuse and neglect. The book draws on a collection of the foremost scholars in the field, as well as clinicians and practice-based experts, to explore the nature, history, impact and justifiability of mandatory reporting laws, their optimal form, legal and conceptual issues, and practical issues and challenges for reporters, professional educators and governments. Key issues in non-Western nations are also explored briefly to assess the potential of socio-legal responses sex trafficking, forced child labour and child marriage. The book is of particular value to policy makers, educators and opinion leaders in government departments dealing with children, and to professionals and organisations who work with children. It is also intended to be a key authority for researchers and teachers in the fields of medicine, nursing, social work, education, law, psychology, health and allied health fields.
Resumo:
Sustainability practices in government regulations and within the society influence the delivery of sustainable housing. The actual delivery rate of Australian sustain-able housing is not as high as other countries. There is an absence of engagement by stakeholders in adopting sustainable housing practices. This may be due, in the current Australian property market, to confusion as to what sustainability features should be considered, given the large range of environmental, economic and social sustainability options possible. One of the main problems appears to be that information demanders, especially real estate agents, valuers, insurance agents and mortgage lenders do not include sustainability perspectives in their advice or in their decision processes. Information distribution in the Australian property market is flawed, resulting in a lack of return-on-investment value of ‘green’ features implemented by some stakeholders. This paper reviewed the global sustainable development concept and Australian sustainable assessment methods. This review identified the possibility of a research project which aimed at identifying and integrating different perceptions and priority needs of the information demanders, for developing a model for the potential implementation of sustainability features distribution in the property industry. This research will reduce confusion on the sustainability-related information which can influence the decision making of stakeholders in the supply and demand of sustainable housing.
Resumo:
This study aims to help broaden the use of electronic portal imaging devices (EPIDs) for pre-treatment patient positioning verification, from photon-beam radiotherapy to photon- and electron-beam radiotherapy, by proposing and testing a method for acquiring clinicallyuseful EPID images of patient anatomy using electron beams, with a view to enabling and encouraging further research in this area. EPID images used in this study were acquired using all available beams from a linac configured to deliver electron beams with nominal energies of 6, 9, 12, 16 and 20 MeV, as well as photon beams with nominal energies of 6 and 10 MV. A widely-available heterogeneous, approximately-humanoid, thorax phantom was used, to provide an indication of the contrast and noise produced when imaging different types of tissue with comparatively realistic thicknesses. The acquired images were automatically calibrated, corrected for the effects of variations in the sensitivity of individual photodiodes, using a flood field image. For electron beam imaging, flood field EPID calibration images were acquired with and without the placement of blocks of water-equivalent plastic (with thicknesses approximately equal to the practical range of electrons in the plastic) placed upstream of the EPID, to filter out the primary electron beam, leaving only the bremsstrahlung photon signal. While the electron beam images acquired using a standard (unfiltered) flood field calibration were observed to be noisy and difficult to interpret, the electron beam images acquired using the filtered flood field calibration showed tissues and bony anatomy with levels of contrast and noise that were similar to the contrast and noise levels seen in the clinically acceptable photon beam EPID images. The best electron beam imaging results (highest contrast, signal-to-noise and contrast-to-noise ratios) were achieved when the images were acquired using the higher energy electron beams (16 and 20 MeV) when the EPID was calibrated using an intermediate (12 MeV) electron beam energy. These results demonstrate the feasibility of acquiring clinically-useful EPID images of patient anatomy using electron beams and suggest important avenues for future investigation, thus enabling and encouraging further research in this area. There is manifest potential for the EPID imaging method proposed in this work to lead to the clinical use of electron beam imaging for geometric verification of electron treatments in the future.
Resumo:
The purpose of this study is to identify the impact of individual differences on service channel selection for e-government services. In a comparative survey of citizens in Germany and Australia (n=1205), we investigate the impact of age, gender, and mobility issues on the selection of personal or mobile communication as channels for service consumption. The results suggest that Australians are more likely to want to use new technology-oriented channels as internet or mobile applications while Germans tend to use classical channels as telephone or in person. Moreover, differences with respect to age, gender, and mobility exist. Implications for practice and issues for future research are discussed.