94 resultados para Constrained Optimal Control


Relevância:

30.00% 30.00%

Publicador:

Resumo:

It is commonplace to use digital video cameras in robotic applications. These cameras have built-in exposure control but they do not have any knowledge of the environment, the lens being used, the important areas of the image and do not always produce optimal image exposure. Therefore, it is desirable and often necessary to control the exposure off the camera. In this paper we present a scheme for exposure control which enables the user application to determine the area of interest. The proposed scheme introduces an intermediate transparent layer between the camera and the user application which combines the information from these for optimal exposure production. We present results from indoor and outdoor scenarios using directional and fish-eye lenses showing the performance and advantages of this framework.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To establish whether there was a difference in health-related quality of life (HRQoL) in people with chronic musculoskeletal disorders (PwCMSKD) after participating in a multimodal physiotherapy program (MPP) either two or three sessions a week. Methods: Total of 114 PwCMSKD participated in this prospective randomised controlled trial. An individualised MPP, consisting of exercises for mobility, motor-control, muscle strengthening, cardiovascular training, and health education, was implemented either twice a week (G2: n = 58) or three times a week) (G3: n = 56) for 1 year. Outcomes: HRQoL physical and mental health state (PHS/MHS), Roland Morris disability Questionnaire (RMQ), Neck-Disability-Index (NDI) and Western Ontario and McMaster Universities’ Arthritis Index (WOMAC) were used to measure outcomes of MPP for people with chronic low back pain, chronic neck pain and osteoarthritis, respectively. Measures were taken at baseline, 8 weeks (8 w), 6 months (6 m), and 1 year (1 y) after starting the programme. Results: No statistically significant differences were found between the two groups (G2 and G3), except in NDI at 8 w (−3.34, (CI 95%: −6.94/0.84, p = 0.025 (scale 0–50)). All variables showed improvement reaching the following values (from baseline to 1 y) G2: PHS: 57.72 (baseline: 41.17; (improvement: 16.55%), MHS: 74.51 (baseline: 47.46, 27.05%), HRQoL 0.90 (baseline: 0.72, 18%)), HRQoL-VAS 84.29 (baseline: 58.04, 26.25%), RMQ 4.15 (baseline: 7.85, 15.42%), NDI 3.96 (baseline: 21.87, 35.82%), WOMAC 7.17 (baseline: 25.51, 19.10%). G3: PHS: 58.64 (baseline: 39.75, 18.89%), MHS: 75.50 (baseline: 45.45, (30.05%), HRQoL 0.67 (baseline: 0.88, 21%), HRQoL-VAS 86.91 (baseline: 52.64, 34.27%), RMQ 4.83 (baseline: 8.93, 17.08%), NDI 4.91 (baseline: 23.82, 37.82%), WOMAC 6.35 (baseline: 15.30, 9.32%). Conclusions: No significant differences between the two groups were found in the outcomes of a MPP except in the NDI at 8 weeks, but both groups improved in all variables during the course of 1 year under study.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Several articles in this journal have studied optimal designs for testing a series of treatments to identify promising ones for further study. These designs formulate testing as an ongoing process until a promising treatment is identified. This formulation is considered to be more realistic but substantially increases the computational complexity. In this article, we show that these new designs, which control the error rates for a series of treatments, can be reformulated as conventional designs that control the error rates for each individual treatment. This reformulation leads to a more meaningful interpretation of the error rates and hence easier specification of the error rates in practice. The reformulation also allows us to use conventional designs from published tables or standard computer programs to design trials for a series of treatments. We illustrate these using a study in soft tissue sarcoma.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper is focused on the study of a vibrating system forced by a rotating unbalance and coupled to a tuned mass damper (TMD). The analysis of the dynamic response of the entire system is used to define the parameters of such device in order to achieve optimal damping properties. The inertial forcing due to the rotating unbalance depends quadratically on the forcing frequency and it leads to optimal tuning parameters that differ from classical values obtained for pure harmonic forcing. Analytical results demonstrate that frequency and damping ratios, as a function of the mass parameter, should be higher than classical optimal parameters. The analytical study is carried out for the undamped primary system, and numerically investigated for the damped primary system. We show that, for practical applications, proper TMD tuning allows to achieve a reduction in the steady-state response of about 20% with respect to the response achieved with a classically tuned damper. Copyright © 2015 by ASME.