275 resultados para COLOR CHANGES


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Electrical impedance tomography (EIT) has been shown to be able to distinguish both ventilation and perfusion. With adequate filtering the regional distributions of both ventilation and perfusion and their relationships could be analysed. Several methods of separation have been suggested previously, including breath holding, electrocardiograph (ECG) gating and frequency filtering. Many of these methods require interventions inappropriate in a clinical setting. This study therefore aims to extend a previously reported frequency filtering technique to a spontaneously breathing cohort and assess the regional distributions of ventilation and perfusion and their relationship. Methods Ten healthy adults were measured during a breath hold and while spontaneously breathing in supine, prone, left and right lateral positions. EIT data were analysed with and without filtering at the respiratory and heart rate. Profiles of ventilation, perfusion and ventilation/perfusion related impedance change were generated and regions of ventilation and pulmonary perfusion were identified and compared. Results Analysis of the filtration technique demonstrated its ability to separate the ventilation and cardiac related impedance signals without negative impact. It was, therefore, deemed suitable for use in this spontaneously breathing cohort. Regional distributions of ventilation, perfusion and the combined ΔZV/ΔZQ were calculated along the gravity axis and anatomically in each position. Along the gravity axis, gravity dependence was seen only in the lateral positions in ventilation distribution, with the dependent lung being better ventilated regardless of position. This gravity dependence was not seen in perfusion. When looking anatomically, differences were only apparent in the lateral positions. The lateral position ventilation distributions showed a difference in the left lung, with the right lung maintaining a similar distribution in both lateral positions. This is likely caused by more pronounced anatomical changes in the left lung when changing positions. Conclusions The modified filtration technique was demonstrated to be effective in separating the ventilation and perfusion signals in spontaneously breathing subjects. Gravity dependence was seen only in ventilation distribution in the left lung in lateral positions, suggesting gravity based shifts in anatomical structures. Gravity dependence was not seen in any perfusion distributions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The research aimed to identify positive behavioural changes that people may make as a result of negotiating the aftermath of a traumatic experience, thereby extending the current cognitive model of posttraumatic growth (PTG). It was hypothesised that significant others would corroborate survivor’s cognitive and behavioural reports of PTG. The sample comprised 176 participants; 88 trauma survivors and 88 significant others. University students accounted for 64% of the sample and 36% were from the broader community. Approximately one third were male. All participants completed the Posttraumatic Growth Inventory [PTGI] and open ended questions regarding behavioural changes. PTGI scores in the survivor sample were corroborated by the significant others with only the Appreciation of Life factor of the PTGI differing between the two groups (e.g., total PTGI scores between groups explained 33.64% of variance). Nearly all of the survivors also reported positive changes in their behaviour and these changes were also corroborated by the significant others. Results provide validation of the posttraumatic growth construct and the PTGI as an instrument of measurement. Findings may also influence therapeutic practice for example, the potential usefulness of corroborating others.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Normal thoracic kyphosis Cobb angle for T5-T12 is most commonly reported as a range of 20-40º [1]. Patients with adolescent idiopathic scoliosis (AIS) exhibit a reduced thoracic kyphosis or hypokyphosis [2] accompanying the coronal and rotary distortion components. As a result, surgical restoration of the thoracic kyphosis while maintaining lumbar lordosis and overall sagittal balance is a critical aspect of achieving good clinical outcomes in AIS patients. Previous studies report an increase in thoracic kyphosis after anterior surgical approaches [3] and a flattening of sagittal contours following posterior approaches [4]. Difficulties with measuring sagittal parameters on radiographs are avoided with reformatted sagittal CT reconstructions due to the superior endplate clarity afforded by this imaging modality and are the subject of analysis in this study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. Previous studies report an increase in thoracic kyphosis after anterior approaches and a flattening of sagittal contours following posterior approaches. Difficulties with measuring sagittal parameters on radiographs are avoided with reformatted sagittal CT reconstructions due to the superior endplate clarity afforded by this imaging modality. Methods. A prospective study of 30 Lenke 1 adolescent idiopathic scoliosis (AIS) patients receiving selective thoracoscopic anterior spinal fusion (TASF) was performed. Participants had ethically approved low dose CT scans at minimum 24 months after surgery in addition to their standard care following surgery. The change in sagittal contours on supine CT was compared to standing radiographic measurements of the same patients and with previous studies. Inter-observer variability was assessed as well as whether hypokyphotic and normokyphotic patient groups responded differently to the thoracoscopic anterior approach. Results. Mean T5-12 kyphosis Cobb angle increased by 11.8 degrees and lumbar lordosis increased by 5.9 degrees on standing radiographs two years after surgery. By comparison, CT measurements of kyphosis and lordosis increased by 12.3 degrees and 7.0 degrees respectively. 95% confidence intervals for inter-observer variability of sagittal contour measurements on supine CT ranged between 5-8 degrees. TASF had a slightly greater corrective effect on patients who were hypokyphotic before surgery compared with those who were normokyphotic. Conclusions. Restoration of sagittal profile is an important goal of scoliosis surgery, but reliable measurement with radiographs suffers from poor endplate clarity. TASF significantly improves thoracic kyphosis and lumbar lordosis while preserving proximal and distal junctional alignment in thoracic AIS patients. Supine CT allows greater endplate clarity for sagittal Cobb measurements and linear relationships were found between supine CT and standing radiographic measurements. In this study, improvements in sagittal kyphosis and lordosis following surgery were in agreement with prior anterior surgery studies, and add to the current evidence suggesting that anterior correction is more capable than posterior approaches of addressing the sagittal component of both the instrumented and adjacent non instrumented segments following surgical correction of progressive Lenke 1 idiopathic scoliosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To investigate the correlations of the global flash multifocal electroretinogram (MOFO mfERG) with common clinical visual assessments – Humphrey perimetry and Stratus circumpapillary retinal nerve fiber layer (RNFL) thickness measurement in type II diabetic patients. Methods: Forty-two diabetic patients participated in the study: ten were free from diabetic retinopathy (DR) while the remainder suffered from mild to moderate non-proliferative diabetic retinopathy (NPDR). Fourteen age-matched controls were recruited for comparison. MOFO mfERG measurements were made under high and low contrast conditions. Humphrey central 30-2 perimetry and Stratus OCT circumpapillary RNFL thickness measurements were also performed. Correlations between local values of implicit time and amplitude of the mfERG components (direct component (DC) and induced component (IC)), and perimetric sensitivity and RNFL thickness were evaluated by mapping the localized responses for the three subject groups. Results: MOFO mfERG was superior to perimetry and RNFL assessments in showing differences between the diabetic groups (with and without DR) and the controls. All the MOFO mfERG amplitudes (except IC amplitude at high contrast) correlated better with perimetry findings (Pearson’s r ranged from 0.23 to 0.36, p<0.01) than did the mfERG implicit time at both high and low contrasts across all subject groups. No consistent correlation was found between the mfERG and RNFL assessments for any group or contrast conditions. The responses of the local MOFO mfERG correlated with local perimetric sensitivity but not with RNFL thickness. Conclusion: Early functional changes in the diabetic retina seem to occur before morphological changes in the RNFL.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As part of an evaluation of the 2010 legislation for child vehicle occupants in Queensland, road-side observations of private passenger vehicles were used to estimate the proportions of children 0-under 7 years travelling in each of the 5 different restraint types (eg. forward facing child restraint). Data was collected in 4 major population centres: Brisbane, Sunshine Coast, Mackay and Townsville. Almost all children were restrained (95.1%, 95% CI 94.3-95.9%), with only 3.3% (95% CI 2.6-4.0%) clearly unrestrained and 44 (1.6%, 95% CI 1.1-2.1%) for whom restraint status could not be determined (‘unknown’). However, around 24.0% (95 CI 21.8-26.2%) of the target-aged children were deemed inappropriately restrained, primarily comprised of 3-6 year olds in seatbelts (18.7% of the 0-6 year olds, 95% CI 16.3-21.1%) or unrestrained (3.7% of the 0-6 year olds, 95% CI 2.5-4.9%) instead of booster seats. In addition, compliance appeared significantly lower for some regional locations where the proportion of children observed as completely unrestrained was relatively high and of concern

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The most common software analysis tools available for measuring fluorescence images are for two-dimensional (2D) data that rely on manual settings for inclusion and exclusion of data points, and computer-aided pattern recognition to support the interpretation and findings of the analysis. It has become increasingly important to be able to measure fluorescence images constructed from three-dimensional (3D) datasets in order to be able to capture the complexity of cellular dynamics and understand the basis of cellular plasticity within biological systems. Sophisticated microscopy instruments have permitted the visualization of 3D fluorescence images through the acquisition of multispectral fluorescence images and powerful analytical software that reconstructs the images from confocal stacks that then provide a 3D representation of the collected 2D images. Advanced design-based stereology methods have progressed from the approximation and assumptions of the original model-based stereology(1) even in complex tissue sections(2). Despite these scientific advances in microscopy, a need remains for an automated analytic method that fully exploits the intrinsic 3D data to allow for the analysis and quantification of the complex changes in cell morphology, protein localization and receptor trafficking. Current techniques available to quantify fluorescence images include Meta-Morph (Molecular Devices, Sunnyvale, CA) and Image J (NIH) which provide manual analysis. Imaris (Andor Technology, Belfast, Northern Ireland) software provides the feature MeasurementPro, which allows the manual creation of measurement points that can be placed in a volume image or drawn on a series of 2D slices to create a 3D object. This method is useful for single-click point measurements to measure a line distance between two objects or to create a polygon that encloses a region of interest, but it is difficult to apply to complex cellular network structures. Filament Tracer (Andor) allows automatic detection of the 3D neuronal filament-like however, this module has been developed to measure defined structures such as neurons, which are comprised of dendrites, axons and spines (tree-like structure). This module has been ingeniously utilized to make morphological measurements to non-neuronal cells(3), however, the output data provide information of an extended cellular network by using a software that depends on a defined cell shape rather than being an amorphous-shaped cellular model. To overcome the issue of analyzing amorphous-shaped cells and making the software more suitable to a biological application, Imaris developed Imaris Cell. This was a scientific project with the Eidgenössische Technische Hochschule, which has been developed to calculate the relationship between cells and organelles. While the software enables the detection of biological constraints, by forcing one nucleus per cell and using cell membranes to segment cells, it cannot be utilized to analyze fluorescence data that are not continuous because ideally it builds cell surface without void spaces. To our knowledge, at present no user-modifiable automated approach that provides morphometric information from 3D fluorescence images has been developed that achieves cellular spatial information of an undefined shape (Figure 1). We have developed an analytical platform using the Imaris core software module and Imaris XT interfaced to MATLAB (Mat Works, Inc.). These tools allow the 3D measurement of cells without a pre-defined shape and with inconsistent fluorescence network components. Furthermore, this method will allow researchers who have extended expertise in biological systems, but not familiarity to computer applications, to perform quantification of morphological changes in cell dynamics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Addictive drugs can activate systems involved in normal reward-related learning, creating long-lasting memories of the drug's reinforcing effects and the environmental cues surrounding the experience. These memories significantly contribute to the maintenance of compulsive drug use as well as cue-induced relapse which can occur even after long periods of abstinence. Synaptic plasticity is thought to be a prominent molecular mechanism underlying drug-induced learning and memories. Ethanol and nicotine are both widely abused drugs that share a common molecular target in the brain, the neuronal nicotinic acetylcholine receptors (nAChRs). The nAChRs are ligand-gated ion channels that are vastly distributed throughout the brain and play a key role in synaptic neurotransmission. In this review, we will delineate the role of nAChRs in the development of ethanol and nicotine addiction. We will characterize both ethanol and nicotine's effects on nAChR-mediated synaptic transmission and plasticity in several key brain areas that are important for addiction. Finally, we will discuss some of the behavioral outcomes of drug-induced synaptic plasticity in animal models. An understanding of the molecular and cellular changes that occur following administration of ethanol and nicotine will lead to better therapeutic strategies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Butterflies and primates are interesting for comparative color vision studies, because both have evolved middle- (M) and long-wavelength- (L) sensitive photopigments with overlapping absorbance spectrum maxima (lambda(max) values). Although positive selection is important for the maintenance of spectral variation within the primate pigments, it remains an open question whether it contributes similarly to the diversification of butterfly pigments. To examine this issue, we performed epimicrospectrophotometry on the eyes of five Limenitis butterfly species and found a 31-nm range of variation in the lambda(max) values of the L-sensitive photopigments (514-545 nm). We cloned partial Limenitis L opsin gene sequences and found a significant excess of replacement substitutions relative to polymorphisms among species. Mapping of these L photopigment lambda(max) values onto a phylogeny revealed two instances within Lepidoptera of convergently evolved L photopigment lineages whose lambda(max) values were blue-shifted. A codon-based maximum-likelihood analysis indicated that, associated with the two blue spectral shifts, four amino acid sites (Ile17Met, Ala64Ser, Asn70Ser, and Ser137Ala) have evolved substitutions in parallel and exhibit significant d(N)/d(S) >1. Homology modeling of the full-length Limenitis arthemis astyanax L opsin placed all four substitutions within the chromophore-binding pocket. Strikingly, the Ser137Ala substitution is in the same position as a site that in primates is responsible for a 5- to 7-nm blue spectral shift. Our data show that some of the same amino acid sites are under positive selection in the photopigments of both butterflies and primates, spanning an evolutionary distance >500 million years.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Women change contraception as they try to conceive, space births, and limit family size. This longitudinal analysis examines contraception changes after reproductive events such as birth, miscarriage or termination among Australian women born from 1973 to 1978 to identify potential opportunities to increase the effectiveness of contraceptive information and service provision. Methods Between 1996 and 2009, 5,631 Australian women randomly sampled from the Australian universal health insurance (Medicare) database completed five self-report postal surveys. Three longitudinal logistic regression models were used to assess the associations between reproductive events (birth only, birth and miscarriage, miscarriage only, termination only, other multiple events, and no new event) and subsequent changes in contraceptive use (start using, stop using, switch method) compared with women who continued to use the same method. Results After women experienced only a birth, or a birth and a miscarriage, they were more likely to start using contraception. Women who experienced miscarriages were more likely to stop using contraception. Women who experienced terminations were more likely to switch methods. There was a significant interaction between reproductive events and time indicating more changes in contraceptive use as women reach their mid-30s. Conclusion Contraceptive use increases after the birth of a child, but decreases after miscarriage indicating the intention for family formation and spacing between children. Switching contraceptive methods after termination suggests these pregnancies were unintended and possibly due to contraceptive failure. Women’s contact with health professionals around the time of reproductive events provides an opportunity to provide contraceptive services.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To examine the symmetry of corneal changes following near work in the fellow eyes of non-amblyopic myopic anisometropes. METHODS: Thirty-four non-amblyopic myopic anisometropes (minimum 1 D spherical equivalent anisometropia) were recruited. Corneal topography was measured with the Medmont E300 Videokeratoscope before and after a controlled near task. Subjects were positioned to minimise head movements and read continuous text on a computer monitor for 10 minutes at an angle of 25 degrees downward gaze and an accommodation demand of 2.5 D. Measures of palpebral aperture morphology during primary and downward gaze were also obtained using digital photography and analysed with customised software. RESULTS: Significant changes in corneal topography were observed after ten minutes of reading. Localised superior regions of corneal topographical change (a hyperopic shift in corneal power) were typically exhibited in both eyes following the near task. The mean change in the corneal sphero-cylinder was +0.02/-0.11 x 113 and +0.02/-0.06 x 68 for the more and less myopic eyes respectively for a 6 mm corneal diameter. A significantly greater change in corneal astigmatism power vector J0 (a larger increase in against the rule astigmatism) was observed in the more myopic eyes (p < 0.01 for a 6 mm diameter). The more and less myopic eyes exhibited a high degree of interocular symmetry for measures of palpebral aperture morphology during both primary and downward gaze. Changes in corneal power vectors following reading were associated with eyelid position during downward gaze. CONCLUSIONS: Changes in corneal topography observed following a controlled reading task were highly symmetrical between the fellow eyes of myopic anisometropes due to the interocular symmetry of the palpebral aperture. However, the more myopic eye did exhibit a small but significantly greater magnitude of change in corneal astigmatism compared to the less myopic eye following reading. These findings may have implications for understanding the mechanism of development of non-amblyopic myopic anisometropia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Right-to-left shunting via a patent foramen ovale (PFO) has a recognized association with embolic events in younger patients. The use of agitated saline contrast imaging (ASCi) for detecting atrial shunting is well documented, however optimal technique is not well described. The purpose of this study is to assess the efficacy and safety of ASCi via TTE for assessment of right-to-left atrial communication in a large cohort of patients. Method: A retrospective review was undertaken of 1162 consecutive transthoracic (TTE) ASCi studies, of which 195 had also undergone clinically indicated transesophageal (TEE) echo. ASCi shunt results were compared with color flow imaging (CFI) and the role of provocative maneuvers (PM) assessed. Results: 403 TTE studies (35%) had paradoxical shunting seen during ASCi. Of these, 48% were positive with PM only. There was strong agreement between TTE ASCi and reported TEE findings (99% sensitivity, 85% specificity), with six false positive and two false negative results. In hindsight, the latter were likely due to suboptimal right atrial opacification, and the former due to transpulmonary shunting. TTE CFI was found to be insensitive (22%) for the detection of a PFO compared with TTE ASCi. Conclusions: TTE ASCi is minimally invasive and highly accurate for the detection of right-to-left atrial communication when PM are used. TTE CFI was found to be insensitive for PFO screening. It is recommended that TTE ASCi should be considered the initial diagnostic tool for the detection of PFO in clinical practice. A dedicated protocol should be followed to ensure adequate agitated saline contrast delivery and performance of provocative maneuvers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In 1962, Dr C. Henry Kempe and his colleagues published the single most important article written to date about child maltreatment: The Battered-Child Syndrome. This chapter analyses the threefold nature of what these authors achieved: clearly identifing the medical evidence of severe child physical abuse and naming it as a syndrome; identifying the medical profession's resistance to its identification; and then translating their scholarship into advocacy for social and legal change. The chapter also traces some of the effects of Kempe's work, including the nature and effect of the subsequent introduction of mandatory reporting laws in the USA and internationally.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The time course of elongation and recovery of axial length associated with a 30 minute accommodative task was studied using optical low coherence reflectometry in a population of young adult myopic (n = 37) and emmetropic (n = 22) subjects. Ten of the 59 subjects were excluded from analysis either due to inconsistent accommodative response, or incomplete anterior biometry data. Those subjects with valid data (n = 49) were found to exhibit a significant axial elongation immediately following the commencement of a 30 minute, 4 D accommodation task, which was sustained for the duration of the task, and ¬was evident to a lesser extent immediately following task cessation. During the accommodation task, on average, the myopic subjects exhibited 22 ± 34 µm, and the emmetropic subjects 6 ± 22 µm of axial elongation, however the differences in axial elongation between the myopic and emmetropic subjects were not statistically significant (p = 0.136). Immediately following the completion of the task, the myopic subjects still exhibited an axial elongation (mean magnitude 12 ± 28 µm), that was significantly greater (p < 0.05) than the changes in axial length observed in the emmetropic subjects (mean change -3 ± 16 µm). Axial length had returned to baseline levels 10 minutes after completion of the accommodation task. The time for recovery from accommodation-induced axial elongation was greater in myopes, which may reflect differences in the biomechanical properties of the globe associated with refractive error. Changes in subfoveal choroidal thickness were able to be measured in 37 of the 59 subjects, and a small amount of choroidal thinning was observed during the accommodation task that was statistically significant in the myopic subjects (p < 0.05). These subfoveal choroidal changes could account for some but not all of the increased axial length during accommodation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this cross-over study was to investigate the changes in corneal thickness, anterior and posterior corneal topography, corneal refractive power and ocular wavefront aberrations, following the short term use of rigid contact lenses. Method: Fourteen participants wore 4 different types of contact lenses (RGP lenses of 9.5 mm and 10.5 mm diameter, and for comparison a PMMA lens of 9.5 mm diameter and a soft silicone hydrogel lens) on 4 different days for a period of 8 h on each day. Measures were collected before and after contact lens wear and additionally on a baseline day. Results: Anterior corneal curvature generally showed a flattening with both of the RGP lenses and a steepening with the PMMA lens. A significant negative correlation was found between the change in corneal swelling and central and peripheral posterior corneal curvature (all p ≤ 0.001). RGP contact lenses caused a significant decrease in corneal refractive power (hyperopic shift) of approximately 0.5 D. The PMMA contact lenses caused the greatest corneal swelling in both the central (27.92 ± 15.49 μm, p < 0.001) and peripheral (17.78 ± 12.11 μm, p = 0.001) corneal regions, a significant flattening of the posterior cornea and an increase in ocular aberrations (all p ≤ 0.05). Conclusion: The corneal swelling associated with RGP lenses was relatively minor, but there was slight central corneal flattening and a clinically significant hyperopic change in corneal refractive power after the first day of lens wear. The PMMA contact lenses resulted in significant corneal swelling and reduced optical performance of the cornea.