95 resultados para C and N stocks
Resumo:
The objective of this study was to examine the hydrothermal liquefaction of sugarcane bagasse using ethanol and black liquor (BL) in a pilot scale. Combinations of co-solvents (ethanol/ water, ethanol/BL) were studied at various concentrations and reaction conditions. The maximum oil yield of 61% was achieved with a reaction temperature of 300 °C for 30 min and using pure BL as a solvent, while the highest higher heating value (HHV) was obtained from a 50:50 ethanol-BL mixture. The oils contained alcohols, esters, phenolic compounds, aromatics, and heterocyclics. The O/C and H/C ratios of the oil were comparable with traditional biodiesel and commercial diesel. Although this study showed there are some improvements to be made to improve the chemical composition, the approach has potential for large-scale production of a substitute for fossil-fuel-based diesel.
Resumo:
The structures of two hydrated salts of 4-aminophenylarsonic acid (p-arsanilic acid), namely ammonium 4-aminophenylarsonate monohydrate, NH4(+)·C6H7AsNO3(-)·H2O, (I), and the one-dimensional coordination polymer catena-poly[[(4-aminophenylarsonato-κO)diaquasodium]-μ-aqua], [Na(C6H7AsNO3)(H2O)3]n, (II), have been determined. In the structure of the ammonium salt, (I), the ammonium cations, arsonate anions and water molecules interact through inter-species N-H...O and arsonate and water O-H...O hydrogen bonds, giving the common two-dimensional layers lying parallel to (010). These layers are extended into three dimensions through bridging hydrogen-bonding interactions involving the para-amine group acting both as a donor and an acceptor. In the structure of the sodium salt, (II), the Na(+) cation is coordinated by five O-atom donors, one from a single monodentate arsonate ligand, two from monodentate water molecules and two from bridging water molecules, giving a very distorted square-pyramidal coordination environment. The water bridges generate one-dimensional chains extending along c and extensive interchain O-H...O and N-H...O hydrogen-bonding interactions link these chains, giving an overall three-dimensional structure. The two structures reported here are the first reported examples of salts of p-arsanilic acid.
Resumo:
If the land sector is to make significant contributions to mitigating anthropogenic greenhouse gas (GHG) emissions in coming decades, it must do so while concurrently expanding production of food and fiber. In our view, mathematical modeling will be required to provide scientific guidance to meet this challenge. In order to be useful in GHG mitigation policy measures, models must simultaneously meet scientific, software engineering, and human capacity requirements. They can be used to understand GHG fluxes, to evaluate proposed GHG mitigation actions, and to predict and monitor the effects of specific actions; the latter applications require a change in mindset that has parallels with the shift from research modeling to decision support. We compare and contrast 6 agro-ecosystem models (FullCAM, DayCent, DNDC, APSIM, WNMM, and AgMod), chosen because they are used in Australian agriculture and forestry. Underlying structural similarities in the representations of carbon flows though plants and soils in these models are complemented by a diverse range of emphases and approaches to the subprocesses within the agro-ecosystem. None of these agro-ecosystem models handles all land sector GHG fluxes, and considerable model-based uncertainty exists for soil C fluxes and enteric methane emissions. The models also show diverse approaches to the initialisation of model simulations, software implementation, distribution, licensing, and software quality assurance; each of these will differentially affect their usefulness for policy-driven GHG mitigation prediction and monitoring. Specific requirements imposed on the use of models by Australian mitigation policy settings are discussed, and areas for further scientific development of agro-ecosystem models for use in GHG mitigation policy are proposed.
Resumo:
Linkage with essential hypertension has been claimed for a microsatellite marker near the angiotensinogen gene (AGT; chromosome 1q42), as has association for the AGT variants M235T, G(-6)A and A(-20)C. To more rigorously evaluate AGT as a candidate gene for hypertension we performed sibpair analysis with multiple microsatellite markers surrounding this locus and using more sophisticated analysis programs. We also performed an association study of the AGT variants in unrelated subjects with a strong family history (two affected parents). For the linkage study, single and multiplex polymerase chain reaction (PCRs) and automated genescan analysis were conducted on DNA from 175 Australian Anglo-Celtic Caucasian hypertensives for the following markers: D1S2880-(2.1 cM)-D1S213-(2.8 cM)-D1S251-(6.5 cM)-AGT-(2.0 cM) -D1S235. Statistical evaluation of genotype data by nonparametric methods resulted in the following scores: Single-point analysis - SPLINK, P > 0.18; APM method, P > 0.25; ASPEX, MLOD < 0.28; SIB-PAIR, P > 0. 24; Multipoint analysis - MAPMAKER/SIBS, MLOD < 0.24; GENEHUNTER, P > 0.35. Exclusion scores of Lod -4.1 to -5.1 were obtained for these markers using MAPMAKER/SIBS for a lambda(s) of 1.6. The association study of G(-6)A, A(-20)C and M235T variants in 111 hypertensives with strong family history and 190 normotensives with no family history showed significant linkage disequilibrium between particular haplotypes, but we could find no association with hypertension. The present study therefore excludes AGT in the etiology of hypertension, at least in the population of Australian Anglo-Celtic Caucasians studied.
Resumo:
- Introduction Heat-based training (HT) is becoming increasingly popular as a means of inducing acclimation before athletic competition in hot conditions and/or to augment the training impulse beyond that achieved in thermo-neutral conditions. Importantly, current understanding of the effects of HT on regenerative processes such as sleep and the interactions with common recovery interventions remain unknown. This study aimed to examine sleep characteristics during five consecutive days of training in the heat with the inclusion of cold-water immersion (CWI) compared to baseline sleep patterns. - Methods Thirty recreationally-trained males completed HT in 32 ± 1 °C and 60% rh for five consecutive days. Conditions included: 1) 90 min cycling at 40 % power at VO2max (Pmax) (90CONT; n = 10); 90 min cycling at 40 % Pmax with a 20 min CWI (14 ± 1 °C; 90CWI; n = 10); and 30 min cycling alternating between 40 and 70 % Pmax every 3 min, with no recovery intervention (30HIT; n = 10). Sleep quality and quantity was assessed during HT and four nights of 'baseline' sleep (BASE). Actigraphy provided measures of time in and out of bed, sleep latency, efficiency, total time in bed and total time asleep, wake after sleep onset, number of awakenings, and wakening duration. Subjective ratings of sleep were also recorded using a 1-5 Likert scale. Repeated measures analysis of variance (ANOVA) was completed to determine effect of time and condition on sleep quality and quantity. Cohen's d effect sizes were also applied to determine magnitude and trends in the data. - Results Sleep latency, efficiency, total time in bed and number of awakenings were not significantly different between BASE and HT (P > 0.05). However, total time asleep was significantly reduced (P = 0.01; d = 1.46) and the duration periods of wakefulness after sleep onset was significantly greater during HT compared with BASE (P = 0.001; d = 1.14). Comparison between training groups showed latency was significantly higher for the 30HIT group compared to 90CONT (P = 0.02; d = 1.33). Nevertheless, there were no differences between training groups for sleep efficiency, total time in bed or asleep, wake after sleep onset, number of awakenings or awake duration (P > 0.05). Further, cold-water immersion recovery had no significant effect on sleep characteristics (P > 0.05). - Discussion Sleep plays an important role in athletic recovery and has previously been demonstrated to be influenced by both exercise training and thermal strain. Present data highlight the effect of HT on reduced sleep quality, specifically reducing total time asleep due to longer duration awake during awakenings after sleep onset. Importantly, although cold water recovery accelerates the removal of thermal load, this intervention did not blunt the negative effects of HT on sleep characteristics. - Conclusion Training in hot conditions may reduce both sleep quantity and quality and should be taken into consideration when administering this training intervention in the field.