97 resultados para BURN
Resumo:
Automatic-dishwasher detergent is a common household substance which is extremely corrosive and potentially fatal if ingested. In this report, we discuss the implications of the ingestion of automatic-dishwasher detergent in 18 children over a three-year period. Ten of the 18 children gained access to the automatic-dishwasher detergent from the dishwasher on the completion of the washing-cycle, while the remainder ingested the detergent directly from the packet. There was a poor correlation between the presenting signs and symptoms and the subsequent endoscopic finding in the 14 children who underwent endoscopy.
Resumo:
Pain is a sensation that most people feel at some time-be it when we accidently stub our toe, or burn our hand when reaching into the oven to pull out that souffle left baking for too long.
Resumo:
Objectives: To determine the cost-effectiveness of the MobileMums intervention. MobileMums is a 12-week programme which assists mothers with young children to be more physically active, primarily through the use of personalised SMS text-messages. Design: A cost-effectiveness analysis using a Markov model to estimate and compare the costs and consequences of MobileMums and usual care. Setting: This study considers the cost-effectiveness of MobileMums in Queensland, Australia. Participants: A hypothetical cohort of over 36 000 women with a child under 1 year old is considered. These women are expected to be eligible and willing to participate in the intervention in Queensland, Australia. Data sources: The model was informed by the effectiveness results from a 9-month two-arm community-based randomised controlled trial undertaken in 2011 and registered retrospectively with the Australian Clinical Trials Registry (ACTRN12611000481976). Baseline characteristics for the model cohort, treatment effects and resource utilisation were all informed by this trial. Main outcome measures: The incremental cost per quality-adjusted life year (QALY) of MobileMums compared with usual care. Results: The intervention is estimated to lead to an increase of 131 QALYs for an additional cost to the health system of 1.1 million Australian dollars (AUD). The expected incremental cost-effectiveness ratio for MobileMums is 8608 AUD per QALY gained. MobileMums has a 98% probability of being cost-effective at a cost-effectiveness threshold of 64 000 AUD. Varying modelling assumptions has little effect on this result. Conclusions: At a cost-effectiveness threshold of 64 000 AUD, MobileMums would likely be a cost-effective use of healthcare resources in Queensland, Australia. Trial registration number: Australian Clinical Trials Registry; ACTRN12611000481976.
Resumo:
INTRODUCTION There is a paucity of research investigating the scar outcome of children with partial thickness burns. The aim of this study was to assess the scar outcome of children with partial thickness burns who received a silver dressing acutely. METHOD Children aged 0-15 years with an acute partial thickness burn, ≤10% TBSA were included. Children were originally recruited for an RCT investigating three dressings for partial thickness burns. Children were assessed at 3 and 6 months after re-epithelialization. 3D photographs were taken of the burn site, POSAS was completed and skin thickness was measured using ultrasound imaging. RESULTS Forty-three children returned for 3 and 6 month follow-ups or returned a photo. Days to re-epithelialization was a significant predictor of skin/scar quality at 3 and 6 months (p<0.01). Patient-rated color and observer-rated vascularity and pigmentation POSAS scores were comparable at 3 months (color vs. vascularity 0.88, p<0.001; color vs. pigmentation 0.64, p<0.001), but patients scored higher than the observer at 6 months (color vs. vascularity 0.57, p<0.05; color vs. pigmentation 0.15, p=0.60). Burn depth was significantly correlated with skin thickness (r=0.51, p<0.01). Hypopigmentation of the burn site was present in 25.8% of children who re-epithelialized in ≤2 weeks. CONCLUSION This study has provided information on outcomes for children with partial thickness burns and highlighted a need for further education of this population.
Resumo:
BACKGROUND This study compared the effects of three silver dressing combinations on small to medium size acute partial thickness burns in children, focusing on re-epithelialization time, pain and distress during dressing changes. METHOD Children (0-15 years) with clean, ≤ 10% total body surface area (TBSA) partial thickness burns who met the inclusion criteria were included in the study. Children received either (1) Acticoat™; (2) Acticoat™ with Mepitel™; or (3) Mepilex Ag™ dressings. Measures of burn re-epithelialization, pain, and distress were recorded at dressing changes every 3-5 days until full re-epithelialization occurred. RESULTS One hundred and three children were recruited with 96 children included for analysis. No infections were detected for the course of the study. When adjusted for burn depth, Acticoat™ significantly increased the expected days to full re-epithelialization by 40% (IRR = 1.40; 95% CI: 1.14-1.73, p < 0.01) and Acticoat™ with Mepitel™ significantly increased the expected days to full re-epithelialization by 33% (IRR = 1.33; 95% CI: 1.08-1.63, p ≤ 0.01) when compared to Mepilex Ag™. Expected FLACC scores in the Mepilex Ag™ group were 32% lower at dressing removal (p = 0.01) and 37% lower at new dressing application (p = 0.04); and scores in the Acticoat™ with Mepitel™ group were 23% lower at dressing removal (p = 0.04) and 40% lower at new dressing application (p < 0.01), in comparison to the Acticoat™ group. Expected Visual Analog Scale-Pain (VAS-P) scores were 25% lower in the Mepilex Ag™ group at dressing removal (p = 0.04) and 34% lower in the Acticoat™ with Mepitel™ group (p = 0.02) at new dressing application in comparison to the Acticoat™ group. There was no significant difference between the Mepilex Ag™ and the Acticoat™ with Mepitel™ groups at all timepoints and with any pain measure. CONCLUSION Mepilex Ag™ is an effective silver dressing, in terms of accelerated wound re-epithelialization time (compared to Acticoat™ and Acticoat™ with Mepitel™) and decreased pain during dressing changes (compared to Acticoat™), for clean, < 10% TBSA partial thickness burns in children.
Resumo:
Chronic wounds cost the Australian health system at least US$2·85 billion per year. Wound care services in Australia involve a complex mix of treatment options, health care sectors and funding mechanisms. It is clear that implementation of evidence-based wound care coincides with large health improvements and cost savings, yet the majority of Australians with chronic wounds do not receive evidence-based treatment. High initial treatment costs, inadequate reimbursement, poor financial incentives to invest in optimal care and limitations in clinical skills are major barriers to the adoption of evidence-based wound care. Enhanced education and appropriate financial incentives in primary care will improve uptake of evidence-based practice. Secondary-level wound specialty clinics to fill referral gaps in the community, boosted by appropriate credentialing, will improve access to specialist care. In order to secure funding for better services in a competitive environment, evidence of cost-effectiveness is required. Future effort to generate evidence on the cost-effectiveness of wound management interventions should provide evidence that decision makers find easy to interpret. If this happens, and it will require a large effort of health services research, it could be used to inform future policy and decision-making activities, reduce health care costs and improve patient outcomes.
Resumo:
Accurate characterization and reporting of organic photovoltaic (OPV) device performance remains one of the important challenges in the field. The large spread among the efficiencies of devices with the same structure reported by different groups is significantly caused by different procedures and equipment used during testing. The presented article addresses this issue by offering a new method of device testing using “suitcase sample” approach combined with outdoor testing that limits the diversity of the equipment, and a strict measurement protocol. A round robin outdoor characterization of roll-to-roll coated OPV cells and modules conducted among 46 laboratories worldwide is presented, where the samples and the testing equipment were integrated in a compact suitcase that served both as a sample transportation tool and as a holder and test equipment during testing. In addition, an internet based coordination was used via plasticphotovoltaics.org that allowed fast and efficient communication among participants and provided a controlled reporting format for the results that eased the analysis of the data. The reported deviations among the laboratories were limited to 5% when compared to the Si reference device integrated in the suitcase and were up to 8% when calculated using the local irradiance data. Therefore, this method offers a fast, cheap and efficient tool for sample sharing and testing that allows conducting outdoor measurements of OPV devices in a reproducible manner.