183 resultados para Almost Contact Manifold


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives To characterize and discover the determinants of the frequency of wear (FOW) of contact lenses. Methods Survey forms were sent to contact lens fitters in up to 40 countries between January and March every year for 5 consecutive years (2007–2011). Practitioners were asked to record data relating to the first 10 contact lens fits or refits performed after receiving the survey form. Only data for daily wear lens fits were analyzed. Results Data were collected in relation to 74,510 and 9,014 soft and rigid lens fits, respectively. Overall, FOW was 5.9±1.7 days per week (DPW). When considering the proportion of lenses worn between one to seven DPW, the distribution for rigid lenses is skewed toward full-time wear (7 DPW), whereas the distribution for soft daily disposable lenses is perhaps bimodal, with large and small peaks at seven and two DPW, respectively. There is a significant variation in FOW among nations (P<0.0001), ranging from 6.8±1.0 DPW in Greece to 5.1±2.5 DPW in Kuwait. For soft lenses, FOW increases with decreasing age. Females (6.0±1.6 DPW) wear lenses more frequently than males (5.8±1.7 DPW) (P=0.0002). FOW is greater among those wearing presbyopic corrections (6.1±1.4 DPW) compared with spherical (5.9±1.7 DPW) and toric (5.9±1.6 DPW) designs (P<0.0001). FOW with hydrogel peroxide systems (6.4±1.1 DPW) was greater than that with multipurpose systems (6.2±1.3 DPW) (P<0.0001). Conclusions Numerous demographic and contact lens–related factors impact FOW. There may be a future trend toward a lower FOW associated with the increasing popularity of daily disposable lenses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The report of this subcommittee concerns the impact of contact lenses (CLs) on the ocular surface, with a particular emphasis on CL discomfort (CLD). We define the ocular surface, its regional anatomy, and the physiological responses of each region to CL wear.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It was widely anticipated that after the introduction of silicone hydrogel lenses, the risk of microbial keratitis would be lower than with hydrogel lenses because of the reduction in hypoxic effects on the corneal epithelium. Large-scale epidemiological studies have confirmed that the absolute and relative risk of microbial keratitis is unchanged with overnight use of silicone hydrogel materials. The key findings include the following: (1) The risk of infection with 30 nights of silicone hydrogel use is equivalent to 6 nights of hydrogel extended wear; (2) Occasional overnight lens use is associated with a greater risk than daily lens use; (3) The rate of vision loss due to corneal infection with silicone hydrogel contact lenses is similar to that seen in hydrogel lenses; (4) The spectrum of causative organisms is similar to that seen in hydrogel lenses, and the material type does not impact the corneal location of presumed microbial keratitis; and (5) Modifiable risk factors for infection include overnight lens use, the degree of exposure, failing to wash hands before lens handling, and storage case hygiene practice. The lack of change in the absolute risk of disease would suggest that exposure to large number of pathogenic organisms can overcome any advantages obtained from eliminating the hypoxic effects of contact lenses. Epidemiological studies remain important in the assessment of new materials and modalities. Consideration of an early adopter effect with studies involving new materials and modalities and further investigation of the impact of second-generation silicone hydrogel materials is warranted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this, the 10th anniversary of the introduction of silicone hydrogel contact lenses onto the market, it is perhaps timely to attempt to reconcile the apparently disparate results from different authors in relation to the incidence of keratitis with silicone hydrogel lenses and indeed, with contact lenses in general. In attempting to understand the findings of these various studies, we propose that consideration be given to the competing effects of an improved physiological response due to increased corneal oxygenation with these lenses versus their mechanical impact...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Contact lenses are a successful and popular means to correct refractive error and are worn by just under 700,000 Australians1 and approximately 125 million people worldwide. The most serious complication of contact lens wear is microbial keratitis, a potentially sight-threatening corneal infection most often caused by bacteria. Gram-negative bacteria, in particular pseudomonas species, account for the majority of severe bacterial infections. Pathogens such as fungi or amoebae, which feature less often, are associated with significant morbidity. These unusual pathogens have come into the spotlight in recent times with an apparent association with specific lens cleaning solutions...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There are probably two main reasons why some practitioners do not bother fitting contact lenses – that it is not profitable and it is clinically too difficult. Although this article will concentrate on clinical issues rather than questions of profitability, I feel that the belief that contact lens fitting is not as profitable as prescribing spectacles is unfounded.