152 resultados para <0.2 µm


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose The purpose of this study was to examine the validity of current practice in smoking cessation for the general population i.e., a telephone counselling and nicotine replacement therapy (NRT) intervention and its applicability to people with chronic hepatitis-C. Methods A randomised controlled trial was conducted over twelve weeks. Following consent, ninety-two smokers (outpatients) with chronic hepatitis-C were recruited by the Nurse Practitioner hepatology, randomly assigned and stratified by number of cigarettes smoked (i.e., 15 and greater; <15) into the intervention group (telephone counselling and NRT) and control group (telephone counselling). Outcomes measured included socio-demographics, nicotine dependence, depression, anxiety and stress and quality of life (QOL). All statistical data were analysed using SPSS. Results After 12 weeks, the intervention group showed a sustained reduction of smoking i.e., 5.8(CI: 2.4,9.3) cigarettes less per day, whereas the control group showed 1.6(CI:-1.9,5.2) cigarette reduction. Although not statistically significantly different (F=2.9, p=0.090) the intervention group on average smoked 4.2 fewer cigarettes compared to the control group. After twelve weeks, seven patients in the intervention group and three patients in the control group reported quitting. Whilst not statistically significant (Fisher’s Exact, p=0.311) this was a clinically significant result. No differences were found for nicotine dependence or depression, anxiety and stress. The intervention group experienced no change in QOL (-0.1,CI:-0.9, 0.6), however, the environmental score for the control group decreased by 1.8(CI:1.0, 2.6,p= 0.001). This was statistically significant. Conclusion A telephone counselling and nicotine replacement therapy intervention from the nurse practitioner, hepatology reduced smoking in patients with chronic hepatitis-C. The intervention group showed a sustained reduction over the 12 weeks. A total of 10 patients quit smoking at the end of the study. QOL deteriorated in the environmental subscale for the control group. These results informed a nurse practitioner model of care for approaches to smoking cessation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction Calculating segmental torso masses in Adolescent Idiopathic Scoliosis (AIS) patients allows the gravitational loading on the scoliotic spine during relaxed standing to be estimated. Methods Low dose CT data was used to calculate vertebral level-by-level torso masses and spinal joint torques for 20 female AIS patients (mean age 15.0 ± 2.7 years, mean Cobb angle 53 ± 7.1°). ImageJ software (v1.45 NIH USA) was used to threshold the T1 to L5 CT images and calculate the segmental torso volume and mass for each vertebral level. Masses for the head, neck and arms were taken from published data. Intervertebral joint torques in the coronal and sagittal planes at each vertebral level were found from the position of the centroid of the segment masses relative to the joint centres (assumed to be at the centre of the intervertebral disc. The joint torque at each level was found by summing torque contributions for all segments above that joint. Results Segmental torso mass increased from 0.6kg at T1 to 1.5kg at L5. The coronal plane joint torques due to gravity were 5-7Nm at the apex of the curve; sagittal torques were 3-5.4Nm. Conclusion CT scans were in the supine position and curve magnitudes are known to be smaller than those in standing. Hence, this study has shown that gravity produces joint torques potentially of higher than 7Nm in the coronal plane and 5Nm in the sagittal plane during relaxed standing in scoliosis patients. The magnitude of these torques may help to explain the mechanics of AIS progression and the mechanics of bracing. This new data on torso segmental mass in AIS patients will assist biomechanical models of scoliosis.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background Engaging clients from the outset of psychotherapy is important for therapeutic success. However, there is little research evaluating therapists’ initial attempts to engage clients. This article reports retrospective analysis of data from a trial of online Cognitive Behavioural Therapy (CBT) for depression. Qualitative and quantitative methods were used to evaluate how therapists manage clients’ expectations at the outset of therapy and its relationship with client retention in the therapeutic intervention. Aims To develop a system to codify expectation management in initial sessions of online CBT and evaluate its relationship with retention. Method Initial qualitative research using conversation analysis identified three different communication practices used by therapists at the start of first sessions: no expectation management, some expectation management, and comprehensive expectation management. These findings were developed into a coding scheme that enabled substantial inter-rater agreement (weighted Kappa = 0.78; 95% CI: 0.52 to 0.94) and was applied to all trial data. Results Adjusting for a range of client variables, primary analysis of data from 147 clients found comprehensive expectation management was associated with clients remaining in therapy for 1.4 sessions longer than those who received no expectation management (95% CI: -0.2 to 3.0). This finding was supported by a sensitivity analysis including an additional 21 clients (1.6 sessions, 95% CI: 0.2 to 3.1). Conclusions Using a combination of qualitative and quantitative methods, this study suggests a relationship between expectation management and client retention in online CBT for depression, which has implications for professional practice. A larger prospective study would enable a more precise estimate of retention.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Wind speed measurement systems are sparse in the tropical regions of Australia. Tropical cyclone wind speeds impacting communities are often ‘guestimated’ from analyzing damaged structures. A re-locatable anemometer system is required to enable measurements of wind speeds. This paper discusses design criteria of the tripods and tie down system, proposed deployment of the anemometers, instrumentation, and data logging. Preliminary assessment of the anemometer response indicates a reliable system for 1 second response, however, it is noted that the Australian building code and wind loading standard uses a moving average time of approximately 0.2 seconds for its wind speed design criteria.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Wind speed measurement systems are sparse in the tropical regions of Australia. Given this, tropical cyclone wind speeds impacting communities are seldom measured and often only ‘guestimated’ by analysing the extent of damage to structures. In an attempt to overcome this dearth of data, a re-locatable network of anemometers to be deployed prior to tropical cyclone landfall is currently being developed. This paper discusses design criteria of the network’s tripods and tie down system, proposed deployment of the anemometers, instrumentation and data logging. Preliminary assessment of the anemometer response indicates a reliable system for measuring the spectral component of wind with frequencies of approximately 1 Hz. This system limitation highlights an important difference between the capabilities of modern instrumentation and that of the Dines anemometer (around 0.2 seconds) that was used to develop much of the design criteria within the Australian building code and wind loading standard.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Results of experimental investigations on the relationship between nanoscale morphology of carbon doped hydrogenated silicon-oxide (SiOCH) low-k films and their electron spectrum of defect states are presented. The SiOCH films have been deposited using trimethylsilane (3MS) - oxygen mixture in a 13.56 MHz plasma enhanced chemical vapor deposition (PECVD) system at variable RF power densities (from 1.3 to 2.6 W/cm2) and gas pressures of 3, 4, and 5 Torr. The atomic structure of the SiOCH films is a mixture of amorphous-nanocrystalline SiO2-like and SiC-like phases. Results of the FTIR spectroscopy and atomic force microscopy suggest that the volume fraction of the SiC-like phase increases from ∼0.2 to 0.4 with RF power. The average size of the nanoscale surface morphology elements of the SiO2-like matrix can be controlled by the RF power density and source gas flow rates. Electron density of the defect states N(E) of the SiOCH films has been investigated with the DLTS technique in the energy range up to 0.6 eV from the bottom of the conduction band. Distinct N(E) peaks at 0.25 - 0.35 eV and 0.42 - 0.52 eV below the conduction band bottom have been observed. The first N(E) peak is identified as originated from E1-like centers in the SiC-like phase. The volume density of the defects can vary from 1011 - 1017 cm-3 depending on specific conditions of the PECVD process.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aims Child-feeding practices may be modifiable risk factors for childhood obesity; however investigation of feeding practices in non-Western populations is scarce. This cross-sectional study examines feeding practices of affluent Indian mothers with children aged 1-5 years residing in Australia and Mumbai, India. The secondary aim was to study the association between maternal and child characteristics and feeding practices. Methods In Australia 230 and in Mumbai 301 mothers completed either a hardcopy or online questionnaire. Self-reported maternal feeding practices (restriction, monitoring, pressure to eat, passive and responsive feeding) were measured using established scales and culturally-specific items. Results Mothers in both samples were equally likely to use non-responsive feeding practices, namely dietary restriction, pressure and passive feeding. Similarly, at least 50% of mothers in both samples did not feed their child responsively (mother decides what and the child decides how much to eat). The only difference observed after controlling for covariates (mothers’ age, BMI, religion, education, questionnaire type, child’s age, birth place, gender, number of siblings, and weight-for-age (WAZ) scores) was that mothers in the Australian sample used higher levels of dietary monitoring (β= 0.2, P= 0.006). Mothers with a higher BMI (OR: 0.84, CI: 0.89-0.99, p=0.03) and following Hinduism (OR: 0.50, CI: 0.33-0.83, p=0.008) were less likely to feed responsively. Conclusions These results suggest that Indian mothers in both the samples may benefit from interventions that promote responsive child-feeding practices.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Land use and agricultural practices can result in important contributions to the global source strength of atmospheric nitrous oxide (N2O) and methane (CH4). However, knowledge of gas flux from irrigated agriculture is very limited. From April 2005 to October 2006, a study was conducted in the Aral Sea Basin, Uzbekistan, to quantify and compare emissions of N2O and CH4 in various annual and perennial land-use systems: irrigated cotton, winter wheat and rice crops, a poplar plantation and a natural Tugai (floodplain) forest. In the annual systems, average N2O emissions ranged from 10 to 150 μg N2O-N m−2 h−1 with highest N2O emissions in the cotton fields, covering a similar range of previous studies from irrigated cropping systems. Emission factors (uncorrected for background emission), used to determine the fertilizer-induced N2O emission as a percentage of N fertilizer applied, ranged from 0.2% to 2.6%. Seasonal variations in N2O emissions were principally controlled by fertilization and irrigation management. Pulses of N2O emissions occurred after concomitant N-fertilizer application and irrigation. The unfertilized poplar plantation showed high N2O emissions over the entire study period (30 μg N2O-N m−2 h−1), whereas only negligible fluxes of N2O (<2 μg N2O-N m−2 h−1) occurred in the Tugai. Significant CH4 fluxes only were determined from the flooded rice field: Fluxes were low with mean flux rates of 32 mg CH4 m−2 day−1 and a low seasonal total of 35.2 kg CH4 ha−1. The global warming potential (GWP) of the N2O and CH4 fluxes was highest under rice and cotton, with seasonal changes between 500 and 3000 kg CO2 eq. ha−1. The biennial cotton–wheat–rice crop rotation commonly practiced in the region would average a GWP of 2500 kg CO2 eq. ha−1 yr−1. The analyses point out opportunities for reducing the GWP of these irrigated agricultural systems by (i) optimization of fertilization and irrigation practices and (ii) conversion of annual cropping systems into perennial forest plantations, especially on less profitable, marginal lands.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We investigate the photoexcited state dynamics in a donor-acceptor copolymer, poly{3,6-dithiophene-2-yl-2,5-di(2-octyldodecyl)-pyrrolo[3,4-c]- pyrrole-1,4-dione-alt-naphthalene} (pDPP-TNT), by picosecond fluorescence and femtosecond transient absorption spectroscopies. Timeresolved fluorescence lifetime measurements of pDPP-TNT thin films reveal that the lifetime of the singlet excited state is 185 ± 5 ps and that singlet-singlet annihilation occurs at excitation photon densities above 6 × 1017 photons/cm3. From the results of singlet-singlet annihilation analysis, we estimate that the single-singlet annihilation rate constant is (6.0 ± 0.2) × 109cm3 s-1 and the singlet diffusion length is -7 nm. From the comparison of femtosecond transient absorption measurements and picosecond fluorescence measurements, it is found that the time profile of the photobleaching signal in the charge-transfer (CT) absorption band coincides with that of the fluorescence intensity and there is no indication of long-lived species, which clearly suggests that charged species, such as polaron pairs and triplet excitons, are not effectively photogenerated in the neat pDPP-TNT polymer.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aim A new method of penumbral analysis is implemented which allows an unambiguous determination of field size and penumbra size and quality for small fields and other non-standard fields. Both source occlusion and lateral electronic disequilibrium will affect the size and shape of cross-axis profile penumbrae; each is examined in detail. Method A new method of penumbral analysis is implemented where the square of the derivative of the cross-axis profile is plotted. The resultant graph displays two peaks in the place of the two penumbrae. This allows a strong visualisation of the quality of a field penumbra, as well as a mathematically consistent method of determining field size (distance between the two peak’s maxima), and penumbra (full-widthtenth-maximum of peak). Cross-axis profiles were simulated in a water phantom at a depth of 5 cm using Monte Carlo modelling, for field sizes between 5 and 30 mm. The field size and penumbra size of each field was calculated using the method above, as well as traditional definitions set out in IEC976. The effect of source occlusion and lateral electronic disequilibrium on the penumbrae was isolated by repeating the simulations removing electron transport and using an electron spot size of 0 mm, respectively. Results All field sizes calculated using the traditional and proposed methods agreed within 0.2 mm. The penumbra size measured using the proposed method was systematically 1.8 mm larger than the traditional method at all field sizes. The size of the source had a larger effect on the size of the penumbra than did lateral electronic disequilibrium, particularly at very small field sizes. Conclusion Traditional methods of calculating field size and penumbra are proved to be mathematically adequate for small fields. However, the field size definition proposed in this study would be more robust amongst other nonstandard fields, such as flattening filter free. Source occlusion plays a bigger role than lateral electronic disequilibrium in small field penumbra size.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Swietenia macrophylla King (Meliaceae: Swietenioideae) provides one of the premier timbers of the world. The mahogany shoot borer Hypsipyla robusta Moore (Lepidoptera: Pyralidae) is an economically important pest of S. macrophylla throughout Asia, Africa and the Pacific. No viable method of controlling this pest is known. Previous observations have suggested that the presence of overhead shade may reduce attack by H. robusta, but this has not been investigated experimentally. This research was therefore designed to assess the influence of light availability on shoot-borer attack on S. macrophylla, by establishing seedlings under three different artificial shade regimes, then using these seedlings to test oviposition preference of adult moths, neonate larval survival and growth and development of shoot borer larvae. Oviposition preference of shoot borer moths was tested on leaves from seedlings grown under artificial shade for 63 weeks. A significant difference in choice was recorded between treatments, with 27.4 ± 1.5 eggs laid under high shade and 87.1 ± 1.8 under low shade. Neonate larval survival on early flushing leaflets of S. macrophylla did not differ significantly between shade treatments. Larval growth rate, estimated by measuring daily frass width, was significantly higher for those larvae fed on seedlings from the high and medium shade treatments (0.1 mm/day), than the low shade treatment (0.06 mm/day). In laboratory-reared larvae, the total mass of frass produced was significantly higher in the high shade treatment (0.4 g) than under the low shade treatment (0.2 g). Longer tunnel lengths were bored by larvae in plants grown under high shade (12.0 ± 2.4 cm) than under low shade (7.07 ± 1.9 cm). However, pupal mass under low shade was 48% higher than that under the high shade treatment, suggesting that plants grown under high shade were of lower nutritional quality for shoot borer larvae. These results indicate that shading of mahogany seedlings may reduce the incidence of shoot borer attack, by influencing both oviposition and larval development. The establishment of mahogany under suitable shade regimes may therefore provide a basis for controlling shoot borer attack using silvicultural approaches.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective.  Leconotide (CVID, AM336, CNSB004) is an omega conopeptide similar to ziconotide, which blocks voltage sensitive calcium channels. However, unlike ziconotide, which must be administered intrathecally, leconotide can be given intravenously because it is less toxic. This study investigated the antihyperalgesic potency of leconotide given intravenously alone and in combinations with morphine-administered intraperitoneally, in a rat model of bone cancer pain. Design.  Syngeneic rat prostate cancer cells AT3B-1 were injected into one tibia of male Wistar rats. The tumor expanded within the bone causing hyperalgesia to heat applied to the ipsilateral hind paw. Measurements were made of the maximum dose (MD) of morphine and leconotide given alone and in combinations that caused no effect in an open-field activity monitor, rotarod, and blood pressure and heart rate measurements. Paw withdrawal thresholds from noxious heat were measured. Dose response curves for morphine (0.312–5.0 mg/kg intraperitoneal) and leconotide (0.002–200 µg/kg intravenous) given alone were plotted and responses compared with those caused by morphine and leconotide in combinations. Results.  Leconotide caused minimal antihyperalgesic effects when administered alone. Morphine given alone intraperitoneally caused dose-related antihyperalgesic effects (ED50 = 2.40 ± 1.24 mg/kg), which were increased by coadministration of leconotide 20 µg/kg (morphine ED50 = 0.16 ± 1.30 mg/kg); 0.2 µg/kg (morphine ED50 = 0.39 ± 1.27 mg/kg); and 0.02 µg/kg (morphine ED50 = 1.24 ± 1.30 mg/kg). Conclusions.  Leconotide caused a significant increase in reversal by morphine of the bone cancer-induced hyperalgesia without increasing the side effect profile of either drug. Clinical Implication.  Translation into clinical practice of the method of analgesia described here will improve the quantity and quality of analgesia in patients with bone metastases. The use of an ordinary parenteral route for administration of the calcium channel blocker (leconotide) at low dose opens up the technique to large numbers of patients who could not have an intrathecal catheter for drug administration. Furthermore, the potentiating synergistic effect with morphine on hyperalgesia without increased side effects will lead to greater analgesia with improved quality of life.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A mother’s perception of her child’s weight may be more important in determining how she feeds her child, than the child’s actual weight status. Use of controlling feeding practices, prompted by perceptions and concerns about weight, may disrupt the child’s innate self-regulation of energy intake. This can promote overeating and overweight (Costanzo & Woody, 1985). This study describes mother’s perception of her child’s weight relative to the child’s actual weight. Mothers in the control group of NOURISH (n=276) were asked to describe their child as underweight, normal weight, or somewhat/very overweight via self-administered questionnaire when children were aged 12-16 months (Daniels et al, 2009). Child’s weight and length were measured by study staff. At assessment, mean age (sd) was 13.7(1.3) months, mean weight-for-age z-score (sd) was 0.6(0.8) (WHO standards, 2008), and 51% were male. Twenty-seven children were perceived as underweight (10%) and twelve children were perceived as overweight (4%). ANOVA revealed significant differences in weight-for-age z-scores across each category of weight perception, mean (sd) -0.2(0.5), 0.6(0.8) and 1.8(0.7) for underweight, normal weight and overweight respectively F(4, 288)= 15.6, (p<0.00). Based on WHO criteria only one of the 27 children was correctly perceived as underweight (WHO 2008). Similarly while 12 children were perceived as overweight, 88 were actually overweight/at risk. At group level, children of mothers who perceived their child as underweight were indeed leaner. However at the individual level mothers could not accurately describe their child’s weight, tending to over-identify underweight and perceive overweight children as normal weight.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Glassy carbon (GC) electrode modified with a self-assembled monolayer (SAM) of 1,8,15,22-tetraaminophthalocyanatocobalt(II) (4α-CoIITAPc) was used for the selective and highly sensitive determination of nitric oxide (NO). The SAM of 4α-CoIITAPc was formed on GC electrode by spontaneous adsorption from DMF containing 1 mM 4α-CoIITAPc. The SAM showed two pairs of well-defined redox peaks corresponding to CoIII/CoII and CoIIIPc−1/CoIIIPc−2 in 0.2 M phosphate buffer (PB) solution (pH 2.5). The SAM modified electrode showed excellent electrocatalytic activity towards the oxidation of nitric oxide (NO) by enhancing its oxidation current with 310 mV less positive potential shift when compared to bare GC electrode. In amperometric measurements, the current response for NO oxidation was linearly increased in the concentration range of 3×10−9 to 30×10−9 M with a detection limit of 1.4×10−10 M (S/N=3). The proposed method showed a better recovery for NO in human blood serum samples.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE The purposes of this study were to: 1) establish inter-instrument reliability between left and right hip accelerometer placement; 2) examine procedural reliability of a walking protocol used to measure physical activity (PA), and; 3) confirm concurrent validity of accelerometers in measuring PA intensity as compared to the gold standard of oxygen consumption measured by indirect calorimetry. METHODS Eight children (mean age: 11.9; SD: 3.2, 75% male) with CP (GMFCS levels I-III) wore ActiGraph GT3X accelerometers on each hip and the Cosmed K4b^{2} portable indirect calorimeter during two measurement sessions in which they performed the six minute walk test (6MWT) at three self-selected speeds (comfortable/slow, brisk, fast). Oxygen consumption (VO2) and accelerometer step and activity count data were recorded. RESULTS Inter-instrument reliability of ActiGraph GT3X accelerometers placed on left and right hips was excellent (ICC=0.96-0.99, CI_{95}: 0.81-0.99). Reproducibility of the protocol was good/excellent (ICC=0.75-0.95, CI_{95}: 0.75-0.98). Concurrent validity of accelerometer count data and VO2 was fair/good (rho=0.67, p< 0.001). The correlation between step count and VO2 was not significant (rho=0.29, p=0.2). CONCLUSION This preliminary research suggests that ActiGraph GT3X accelerometers are reliable and valid devices to monitor PA during walking in children with CP and may be appropriate in rehabilitation research and clinical practice. ActiGraph GTX3 step counts were not valid for this sample and further research is warranted.