100 resultados para tip credits


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Less invasive methods of determining cardiac output are now readily available. Using indicator dilution technique, for example has made it easier to continuously measure cardiac output because it uses the existing intra-arterial line. Therefore gone is the need for a pulmonary artery floatation catheter and with it the ability to measure left atrial and left ventricular work indices as well the ability to monitor and measure a mixed venous saturation (SvO2). Purpose The aim of this paper is to put forward the notion that SvO2 provides valuable information about oxygen consumption and venous reserve; important measures in the critically ill to ensure oxygen supply meets cellular demand. In an attempt to portray this, a simplified example of the septic patient is offered to highlight the changing pathophysiological sequelae of the inflammatory process and its importance for monitoring SvO2. Relevance to clinical practice SvO2 monitoring, it could be argued, provides the gold standard for assessing arterial and venous oxygen indices in the critically ill. For the bedside ICU nurse the plethora of information inherent in SvO2 monitoring could provide them with important data that will assist in averting potential problems with oxygen delivery and consumption. However, it has been suggested that central venous saturation (ScvO2) might be an attractive alternative to SvO2 because of its less invasiveness and ease of obtaining a sample for analysis. There are problems with this approach and these are to do with where the catheter tip is sited and the nature of the venous admixture at this site. Studies have shown that ScvO2 is less accurate than SvO2 and should not be used as a sole guiding variable for decision-making. These studies have demonstrated that there is an unacceptably wide range in variance between ScvO2 and SvO2 and this is dependent on the presenting disease, in some cases SvO2 will be significantly lower than ScvO2. Conclusion Whilst newer technologies have been developed to continuously measure cardiac output, SvO2 monitoring is still an important adjunct to clinical decision-making in the ICU. Given the information that it provides, seeking alternatives such as ScvO2 or blood samples obtained from femorally placed central venous lines, can unnecessarily lead to inappropriate treatment being given or withheld. Instead when using ScvO2, trending of this variable should provide clinical determinates that are useable for the bedside ICU nurse, remembering that in most conditions SvO2 will be approximately 16% lower.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The effects of crack depth (a/W) and specimen width W on the fracture toughness and ductile±brittle transition have been investigated using three-point bend specimens. Finite element analysis is employed to obtain the stress-strain fields ahead of the crack tip. The results show that both normalized crack depth (a/W) and specimen width (W) affect the fracture toughness and ductile±brittle fracture transition. The measured crack tip opening displacement decreases and ductile±brittle transition occurs with increasing crack depth (a/W) from 0.1 to 0.2 and 0.3. At a fixed a/W (0.2 or 0.3), all specimens fail by cleavage prior to ductile tearing when specimen width W increases from 25 to 40 and 50 mm. The lower bound fracture toughness is not sensitive to crack depth and specimen width. Finite element analysis shows that the opening stress in the remaining ligament is elevated with increasing crack depth or specimen width due to the increase of in-plane constraint. The average local cleavage stress is dependent on both crack depth and specimen width but its lower bound value is not sensitive to constraint level. No fixed distance can be found from the cleavage initiation site to the crack tip and this distance increases gradually with decreasing inplane constraint.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Large deformation finite element analysis has been carried out to investigate the stress-strain fields ahead of a growing crack for compact tension .a=W D 0:5/ and three-point bend .a=W D 0:1 and 0:5/ specimens under plane stress condition. The crack growth is controlled by the experimental J -integral resistance curves measured by Sun et al. The results indicate that the distributions of opening stress, equivalent stress and equivalent strain ahead of a growing crack are not sensitive to specimen geometry. For both stationary and growing cracks, similar distributions of opening stress and triaxiality can be found along the ligament. During stable crack growth, the crack-tip opening displacement (CTOD) resistance curve and the cohesive fracture energy in the fracture process zone are independent of specimen geometry and may be suitable criteria for characterizing stable crack growth in plane stress.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ductile-brittle fracture transition was investigated using compact tension (CT) specimens from -70oC to 40oC for a carbon steel. Large deformation finite element analysis has been carried out to simulate the stable crack growth in the compact tension (CT, a/W=0.6), three point-point bend (SE(B), a/W=0.1) and centre-cracked tension (M(T), a/W=0.5) specimens. Experimental crack tip opening displacement (CTOD) resistance curve was employed as the crack growth criterion. Ductile tearing is sensitive to constraint and tearing modulus increases with reduced constraint level. The finite element analysis shows that path-dependence of J-integral occurs from the very beginning of crack growth and ductile crack growth elevates the opening stress on the remaining ligament. Cleavage may occur after some ductile crack growth due to the increase of opening stress. For both stationary and growing cracks, the magnitude of opening stress increases with increasing in-plane constraint. The ductile-brittle transition takes place when the opening stress ahead of the crack tip reaches the local cleavage stress as the in-plane constraint of the specimen increases.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This review focuses on one of the fundamental phenomena that occur upon application of sufficiently strong electric fields to gases, namely the formation and propagation of ionization waves-streamers. The dynamics of streamers is controlled by strongly nonlinear coupling, in localized streamer tip regions, between enhanced (due to charge separation) electric field and ionization and transport of charged species in the enhanced field. Streamers appear in nature (as initial stages of sparks and lightning, as huge structures-sprites above thunderclouds), and are also found in numerous technological applications of electrical discharges. Here we discuss the fundamental physics of the guided streamer-like structures-plasma bullets which are produced in cold atmospheric-pressure plasma jets. Plasma bullets are guided ionization waves moving in a thin column of a jet of plasma forming gases (e.g.,He or Ar) expanding into ambient air. In contrast to streamers in a free (unbounded) space that propagate in a stochastic manner and often branch, guided ionization waves are repetitive and highly-reproducible and propagate along the same path-the jet axis. This property of guided streamers, in comparison with streamers in a free space, enables many advanced time-resolved experimental studies of ionization waves with nanosecond precision. In particular, experimental studies on manipulation of streamers by external electric fields and streamer interactions are critically examined. This review also introduces the basic theories and recent advances on the experimental and computational studies of guided streamers, in particular related to the propagation dynamics of ionization waves and the various parameters of relevance to plasma streamers. This knowledge is very useful to optimize the efficacy of applications of plasma streamer discharges in various fields ranging from health care and medicine to materials science and nanotechnology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

One-dimensional ZnO nanostructures were successfully synthesized on single-crystal silicon substrates via a simple thermal evaporation and vapour-phase transport method under different process temperatures from 500 to 1000 °C. The detailed and in-depth analysis of the experimental results shows that the growth of ZnO nanostructures at process temperatures of 500, 800, and 1000 °C is governed by different growth mechanisms. At a low process temperature of 500 °C, the ZnO nanostructures feature flat and smooth tips, and their growth is primarily governed by the vapour-solid mechanism. At an intermediate process temperature of 800 °C, the ZnO nanostructures feature cone-shape tips, and their growth is primarily governed by the self-catalyzed and saturated vapour–liquid–solid mechanism. At a high process temperature of 1000 °C, the alloy tip appears on the front side of the ZnO nanostructures, and their growth is primarily governed by the common catalyst-assisted vapour–liquid–solid mechanism. It is also shown that the morphological, structural, optical, and compositional properties of the synthesized ZnO nanostructures are closely related to the process temperature. These results are highly relevant to the development of light-emitting diodes, chemical sensors, energy conversion devices, and other advanced applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recent literature credits community art spaces with both enhancing social interaction and engagement and generating economic revitalization. This article argues that the ability of art spaces to realize these outcomes is linked to their role as public spaces and that their community development potential can be expanded with greater attention to this role. An analysis of the public space characteristics is useful because it encourages consideration of sometimes overlooked issues, particularly the effect of the physical environment on outcomes related to community development. I examine the relationship between public space and community development at various types of art spaces including artist cooperatives, ethnic-specific art spaces, and city-sponsored art centers in central city and suburban locations. This study shows that through their programming and other activities, art spaces serve various public space roles related to community development. However, the ability of many to perform as public spaces is hindered by facility design issues and poor physical connections in their surrounding area. This article concludes with proposals for enhancing the community development role of the art spaces through their function as public spaces.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AN explanation of the path of flood waters that have surged east and south west in southern Queensland. CREDITS: Audio by Amanda Gearing

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To reduce the natural convection heat loss from enclosures many researchers used convection suppression devices in the past. In this study a single baffle is used under the top tip to investigate numerically the natural convection heat loss in an attic shaped enclosure which is a cost effective approach. The case considered here is one inclined wall of the enclosure is uniformly heated while the other inclined wall is uniformly cooled with adiabatic bottom wall. The finite volume method has been used to discretize the governing equations, with the QUICK scheme approximating the advection term. The diffusion terms are discretized using central-differencing with second order accuracy. A wide range of governing parameters are studied (Rayleigh number, aspect ratio, baffle length etc.). It is observed that the heat transfer due to natural convection in the enclosure reduces when the baffle length is increased. Effects of other parameters on heat transfer and flow field are described in this study.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We studied the wing morphology, echolocation calls, diet and emergence time of the black-bearded tomb bat (Taphozous melanopogon) from May to October 2006 in Guangxi Province, southwest China. Taphozous melanopogon has wings with high aspect ratio, high loading and pointed wing-tip shape-characteristics associated with fast flight in open space. This species usually produces low-intensity, low frequency, and frequency-modulated (FM) calls usually containing up to four harmonics, with most energy in the second (or sometimes third) harmonic. The diet of this species consists mostly of Lepidoptera and Hemiptera. Timing of evening emergence is correlated with the time of sunset. This is the first study to describe the flight and echolocation behavior of this species in China, and opens the way for future studies of its biology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper, the axial performance of two heavily instrumented barrette piles, with and without grouting, socket into gravel layer in Taipei are evaluated based on the results of pile load tests. Both piles are 44 m long with the same dimension of 0.8 by 2.7 m, installed by hydraulic long bucket. One of the piles with toe grouting was socket 6 m into gravel layer and the other pile without toe grouting was socket 3 m into gravel layer. The load versus displacement relationships at pile head, the t-z curves of upper soil layers and of bottom gravel layer, and the tip resistance versus displacement relationships are important concerns and are presented in the paper. The t-z curves interpreted from the measured data along depth are also simulated by the hyperbolic model.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Direct writing melt electrospinning is an additive manufacturing technique capable of the layer-by-layer fabrication of highly ordered 3d tissue engineering scaffolds from micron-diameter fibres. The utility of these scaffolds, however, is limited by the maximum achievable height of controlled fibre deposition, beyond which the structure becomes increasingly disordered. A source of this disorder is charge build-up on the deposited polymer producing unwanted coulombic forces. In this study we introduce a novel melt electrospinning platform with dual voltage power supplies to reduce undesirable charge effects and improve fibre deposition control. We produced and characterised several 90° cross-hatched fibre scaffolds using a range of needle/collector plate voltages. Fibre thickness was found to be sensitive only to overall potential and invariant to specific tip/collector voltage. We also produced ordered scaffolds up to 200 layers thick (fibre spacing 1 mm, diameter 40 μm) and characterised structure in terms of three distinct zones; ordered, semi-ordered and disordered. Our in vitro analysis indicates successful cell attachment and distribution throughout the scaffolds, with little evidence of cell death after seven days. This study demonstrates the importance of electrostatic control for reducing destabilising polymer charge effects and enabling the fabrication of morphologically suitable scaffolds for tissue engineering.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The Pharmacy Board of Australia stipulated that for renewal of registration, pharmacists must have accrued a minimum of 20 CPD credits over the 2010-11 registration years (1). Mandatory CPD is not new in Pharmacy. The UK and New Zealand have both established systems of CPD in recent years. The purpose of this study is to investigate established CPD processes in the UK and New Zealand with the view to making recommendations for the implementation of the CPD process in Australia. Objectives: To compare the acquisition and guidance on documentation of CPD credit points in Australia, New Zealand and the United Kingdom. Methodology: A comparative online search of the websites of each of the registering authorities was undertaken. Any practice standards or guidelines which relate to registration or continuing professional development were analysed and compared. Results: In New Zealand the Pharmacy Council require Pharmacists to have a minimum of 12 outcome credits over a 3-year period for recertification (2, 3). The outcome credit related to each CPD action and is based on relevance to the pharmacist and their practice. It is graded between one, for CPD which has occasional relevance to practice and three which have considerable relevance to practice. There are examples of completed CPD recording sheets on their website (8). In the UK, The General Pharmaceutical Council require Pharmacists to make a minimum of nine CPD entries per year (4) and detailed guidance on how to record CPD activities is provided (5,7). The Pharmacy Board of Australia divides CPD activities into three groups (6). Of the 20 credits required annually only 10 can be gained from group one activities, which is information accessed without assessment. There is only brief guidance on the recording of CPD. Discussion: The GPhC in the UK provided the most comprehensive guidance on acquisition of CPD credit points and documentation (5,7) The Pharmacy Council of New Zealand made CPD points relevant to practice.(2,8) The Pharmacy Board of Australia provided limited information for pharmacists on CPD activities, which may impede pharmacist participation. Information may assist in increasing pharmacists’ engagement in CPD activities. In conclusion, there is variation between the three countries in the amount and type of information provided about CPD requirements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objetivo Establecer una posible relación entre la fuerza (Jamar), el dolor (EVA) y la capacidad funcional referida por el paciente (DASH) determinando en qué grado influyen unas en otras. Estudio observacional transversal analítico. Participantes Muestra de 72 pacientes que presentaban una artrosis trapecio metacarpiana grado 2-3 de Eaton. Los pacientes fueron reclutados cuando acudían a la Unidad de Cirugía de mano. Método Se realizaron mediciones de fuerza de agarre, pinza, valoración del dolor y funcionalidad, y se establecieron las correlaciones entre cada una de ellas. Resultados El modelo más significativo para la función (R2 =0.83) incluye la variable dolor y la fuerza. Pero es la fuerza punta contra punta la que presenta una mayor correlación con el cuestionario DASH (B-estandarizado: –57). Respecto al dolor, influye en todas las mediciones de fuerza realizadas con el dinamómetro, siendo también la fuerza de la pinza punta contra punta la que presenta una mayor correlación. Conclusiones Los hallazgos corroboran que existe una correlación significativa entre la función referida por el paciente y variables que podemos medir en consulta, como la fuerza del puño y la pinza. Pero también esta correlación es significativa entre las variables función y dolor entre sí, pero es la pinza punta contra punta la que presenta una mayor asociación con el cuestionario DASH. Abstract in English Objective To assess the relationship between muscle strength (Jama), and pain (VAS) levels with hand function (DASH) in patients with trapeziometarcapal osteoarthritis. Cross-sectional study. Participants Sample of 72 patients with osteoarthritis stage 2-3 (Eaton) and trapeziometacarpal osteoarthritis. Patients were recruited when they came to the Hand Surgery Unit. Method Grip strength, pinch, pain and hand function were measured, and correlation and regression coefficients between them were obtained. Results For function, the most significant model (R2 = 0.83) included pain and strength. But it is tip to tip pinch force which has a stronger relationship with DASH (Standardized B: –57) questionnaire. Pain also influenced strength measured with the dynamometer but it was tip to tip pinch force that was the most affected. Conclusions Findings confirm that there is a significant correlation between function referred by the patient and variables that can be measured in the clinic such as grip strength and pinch. The correlation between pain intensity and function was also significant, but tip to tip pinch strength had the greatest impact on the function.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background The evaluation of the hand function is an essential element within the clinical practice. The usual assessments are focus on the ability to perform activities of daily life. The inclusion of instruments to measure kinematic variables provides a new approach to the assessment. Inertial sensors adapted to the hand could be used as a complementary instrument to the traditional assessment. Material: clinimetric assessment (Upper Limb Functional Index, Quick Dash), antrophometric variables (eight and weight), dynamometry (palm preasure) was taken. Functional analysis was made with Acceleglove system for the right hand and computer system. The glove has six acceleration sensor, one on each finger and another one on the reverse palm. Method Analytic, transversal approach. Ten healthy subject made six task on evaluation table (tripod pinch, lateral pinch and tip pinch, extension grip, spherical grip and power grip). Each task was made and measure three times, the second one was analyze for the results section. A Matlab script was created for the analysis of each movement and detection phase based on module vector. Results The module acceleration vector offers useful information of the hand function. The data analysis obtained during the performance of functional gestures allows to identify five different phases within the movement, three static phase and tow dynamic, each module vector was allied to one task. Conclusion Module vector variables could be used for the analysis of the different task made by the hand. Inertial sensor could be use as a complement for the traditional assessment system.