182 resultados para optical spectrum analyzer


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Clinicians regularly face the confronting challenge of differentiating a choroidal naevus from a melanoma. Uveal naevi are a relatively common finding during routine eye examinations: a prevalence of 6.5 per cent has been reported.1 In contrast, malignant melanomata are uncommon, being found in six persons per million population, but they can have devastating implications and consequences.2 Differential diagnoses can be difficult to make with certainty; any additional information that can assist in this process is advantageous...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the flight trials of an electro-optical (EO) sense-and-avoid system onboard a Cessna host aircraft (camera aircraft). We focus on the autonomous collision avoidance capability of the sense-and-avoid system; that is, closed-loop integration with the onboard aircraft autopilot. We also discuss the system’s approach to target detection and avoidance control, as well as the methodology of the flight trials. The results demonstrate the ability of the sense-and-avoid system to automatically detect potential conflicting aircraft and engage the host Cessna autopilot to perform an avoidance manoeuvre, all without any human intervention

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Spectrum sensing is considered to be one of the most important tasks in cognitive radio. One of the common assumption among current spectrum sensing detectors is the full presence or complete absence of the primary user within the sensing period. In reality, there are many situations where the primary user signal only occupies a portion of the observed signal and the assumption of primary user duty cycle not necessarily fulfilled. In this paper we show that the true detection performance can degrade from the assumed achievable values when the observed primary user exhibits a certain duty cycle. Therefore, a two-stage detection method incorporating primary user duty cycle that enhances the detection performance is proposed. The proposed detector can improve the probability of detection under low duty cycle at the expense of a small decrease in performance at high duty cycle.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is a need for an accurate real-time quantitative system that would enhance decision-making in the treatment of osteoarthritis. To achieve this objective, significant research is required that will enable articular cartilage properties to be measured and categorized for health and functionality without the need for laboratory tests involving biopsies for pathological evaluation. Such a system would provide the capability of access to the internal condition of the cartilage matrix and thus extend the vision-based arthroscopy that is currently used beyond the subjective evaluation of surgeons. The system required must be able to non-destructively probe the entire thickness of the cartilage and its immediate subchondral bone layer. In this thesis, near infrared spectroscopy is investigated for the purpose mentioned above. The aim is to relate it to the structure and load bearing properties of the cartilage matrix to the near infrared absorption spectrum and establish functional relationships that will provide objective, quantitative and repeatable categorization of cartilage condition outside the area of visible degradation in a joint. Based on results from traditional mechanical testing, their innovative interpretation and relationship with spectroscopic data, new parameters were developed. These were then evaluated for their consistency in discriminating between healthy viable and degraded cartilage. The mechanical and physico-chemical properties were related to specific regions of the near infrared absorption spectrum that were identified as part of the research conducted for this thesis. The relationships between the tissue's near infrared spectral response and the new parameters were modeled using multivariate statistical techniques based on partial least squares regression (PLSR). With significantly high levels of statistical correlation, the modeled relationships were demonstrated to possess considerable potential in predicting the properties of unknown tissue samples in a quick and non-destructive manner. In order to adapt near infrared spectroscopy for clinical applications, a balance between probe diameter and the number of active transmit-receive optic fibres must be optimized. This was achieved in the course of this research, resulting in an optimal probe configuration that could be adapted for joint tissue evaluation. Furthermore, as a proof-of-concept, a protocol for obtaining the new parameters from the near infrared absorption spectra of cartilage was developed and implemented in a graphical user interface (GUI)-based software, and used to assess cartilage-on-bone samples in vitro. This conceptual implementation has been demonstrated, in part by the individual parametric relationship with the near infrared absorption spectrum, the capacity of the proposed system to facilitate real-time, non-destructive evaluation of cartilage matrix integrity. In summary, the potential of the optical near infrared spectroscopy for evaluating articular cartilage and bone laminate has been demonstrated in this thesis. The approach could have a spin-off for other soft tissues and organs of the body. It builds on the earlier work of the group at QUT, enhancing the near infrared component of the ongoing research on developing a tool for cartilage evaluation that goes beyond visual and subjective methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The current rapid urban growth throughout the world manifests in various ways and historically cities have grown, similarly, alternately or simultaneously between planned extensions and organic informal settlements (Mumford, 1989). Within cities different urban morphological regions can reveal different contexts of economic growth and/or periods of dramatic social/technological change (Whitehand, 2001, 105). Morpho-typological study of alternate contexts can present alternative models and contribute to the present discourse which questions traditional paradigms of urban planning and design (Todes et al, 2010). In this study a series of cities are examined as a preliminary exploration into the urban morphology of cities in ‘humid subtropical’ climates. From an initial set of twenty, six cities were selected: Sao Paulo, Brazil; Jacksonville, USA; Maputo, Mozambique; Kanpur, India; Hong Kong, China; and Brisbane, Australia. The urban form was analysed from satellite imagery at a constant scale. Urban morphological regions (types) were identified as those demonstrating particular consistant characteristics of form (density, typology and pattern) different to their surroundings when examined at a constant scale. This analysis was correlated against existing data and literature discussing the proliferation of two types of urban development, ‘informal settlement’ (defined here as self-organised communities identifiable but not always synonymous with ‘slums’) and ‘suburbia’ (defined here as master planned communities of generally detached houses prevalent in western society) - the extreme ends of a hypothetical spectrum from ‘planned’ to ‘spontaneous’ urban development. Preliminary results show some cities contain a wide variety of urban form ranging from the highly organic ‘self-organised’ type to the highly planned ‘master planned community’ (in the case of Sao Paulo) while others tend to fall at one end of the planning spectrum or the other (more planned in the cases of Brisbane and Jacksonville; and both highly planned and highly organic in the case of Maputo). Further research will examine the social, economical and political drivers and controls which lead to this diversity or homogeneity of urban form and speculates on the role of self-organisation as a process for the adaptation of urban form.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To investigate the correlations of the global flash multifocal electroretinogram (MOFO mfERG) with common clinical visual assessments – Humphrey perimetry and Stratus circumpapillary retinal nerve fiber layer (RNFL) thickness measurement in type II diabetic patients. Methods: Forty-two diabetic patients participated in the study: ten were free from diabetic retinopathy (DR) while the remainder suffered from mild to moderate non-proliferative diabetic retinopathy (NPDR). Fourteen age-matched controls were recruited for comparison. MOFO mfERG measurements were made under high and low contrast conditions. Humphrey central 30-2 perimetry and Stratus OCT circumpapillary RNFL thickness measurements were also performed. Correlations between local values of implicit time and amplitude of the mfERG components (direct component (DC) and induced component (IC)), and perimetric sensitivity and RNFL thickness were evaluated by mapping the localized responses for the three subject groups. Results: MOFO mfERG was superior to perimetry and RNFL assessments in showing differences between the diabetic groups (with and without DR) and the controls. All the MOFO mfERG amplitudes (except IC amplitude at high contrast) correlated better with perimetry findings (Pearson’s r ranged from 0.23 to 0.36, p<0.01) than did the mfERG implicit time at both high and low contrasts across all subject groups. No consistent correlation was found between the mfERG and RNFL assessments for any group or contrast conditions. The responses of the local MOFO mfERG correlated with local perimetric sensitivity but not with RNFL thickness. Conclusion: Early functional changes in the diabetic retina seem to occur before morphological changes in the RNFL.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cognitive radio is an emerging technology proposing the concept of dynamic spec- trum access as a solution to the looming problem of spectrum scarcity caused by the growth in wireless communication systems. Under the proposed concept, non- licensed, secondary users (SU) can access spectrum owned by licensed, primary users (PU) so long as interference to PU are kept minimal. Spectrum sensing is a crucial task in cognitive radio whereby the SU senses the spectrum to detect the presence or absence of any PU signal. Conventional spectrum sensing assumes the PU signal as ‘stationary’ and remains in the same activity state during the sensing cycle, while an emerging trend models PU as ‘non-stationary’ and undergoes state changes. Existing studies have focused on non-stationary PU during the transmission period, however very little research considered the impact on spectrum sensing when the PU is non-stationary during the sensing period. The concept of PU duty cycle is developed as a tool to analyse the performance of spectrum sensing detectors when detecting non-stationary PU signals. New detectors are also proposed to optimise detection with respect to duty cycle ex- hibited by the PU. This research consists of two major investigations. The first stage investigates the impact of duty cycle on the performance of existing detec- tors and the extent of the problem in existing studies. The second stage develops new detection models and frameworks to ensure the integrity of spectrum sensing when detecting non-stationary PU signals. The first investigation demonstrates that conventional signal model formulated for stationary PU does not accurately reflect the behaviour of a non-stationary PU. Therefore the performance calculated and assumed to be achievable by the conventional detector does not reflect actual performance achieved. Through analysing the statistical properties of duty cycle, performance degradation is proved to be a problem that cannot be easily neglected in existing sensing studies when PU is modelled as non-stationary. The second investigation presents detectors that are aware of the duty cycle ex- hibited by a non-stationary PU. A two stage detection model is proposed to improve the detection performance and robustness to changes in duty cycle. This detector is most suitable for applications that require long sensing periods. A second detector, the duty cycle based energy detector is formulated by integrat- ing the distribution of duty cycle into the test statistic of the energy detector and suitable for short sensing periods. The decision threshold is optimised with respect to the traffic model of the PU, hence the proposed detector can calculate average detection performance that reflect realistic results. A detection framework for the application of spectrum sensing optimisation is proposed to provide clear guidance on the constraints on sensing and detection model. Following this framework will ensure the signal model accurately reflects practical behaviour while the detection model implemented is also suitable for the desired detection assumption. Based on this framework, a spectrum sensing optimisation algorithm is further developed to maximise the sensing efficiency for non-stationary PU. New optimisation constraints are derived to account for any PU state changes within the sensing cycle while implementing the proposed duty cycle based detector.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To determine whether there is a difference in neuroretinal function and in macular pigment optical density between persons with high- and low-risk gene variants for age-related macular degeneration (AMD) and no ophthalmoscopic signs of AMD, and to compare the results on neuroretinal function to patients with manifest early AMD. Methods and Participants: Neuroretinal function was assessed with the multifocal electroretinogram (mfERG) for 32 participants (22 healthy persons with no AMD and 10 early AMD patients). The 22 healthy participants with no AMD had high- or low-risk genotypes for either CFH (rs380390) and/or ARMS2 (rs10490924). Trough-to-peak response densities and peak-implicit times were analyzed in 5 concentric rings. Macular pigment optical densitometry was assessed by customized heterochromatic flicker photometry. Results: Trough-to-peak response densities for concentric rings 1 to 3 were, on average, significantly greater in participants with high-risk genotypes than in participants with low-risk genotypes and in persons with early AMD after correction for age and smoking (p<0.05). The group peak- implicit times for ring 1 were, on average, delayed in the patients with early AMD compared with the participants with high- or low-risk genotypes, although these differences were not significant. There was no significant correlation between genotypes and macular pigment optical density. Conclusion: Increased neuroretinal activity in persons who carry high-risk AMD genotypes may be due to genetically determined subclinical inflammatory and/or histological changes in the retina. Neuroretinal function in healthy persons genetically susceptible to AMD may be a useful additional early biomarker (in combination with genetics) before there is clinical manifestation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. To evaluate the use of optical coherence tomography (OCT) to assess the effect of different soft contact lenses on corneoscleral morphology. Methods. Ten subjects had anterior segment OCT B-scans taken in the morning and again after six hours of soft contact lens wear. For each subject, three different contact lenses were used in the right eye on non-consecutive days, including a hydrogel sphere, a silicone hydrogel sphere and a silicone hydrogel toric. After image registration and layer segmentation, analyses were performed of the first hyper-reflective layer (HRL), the epithelial basement membrane (EBL) and the epithelial thickness (HRL to EBL). A root mean square difference (RMSD) of the layer profiles and the thickness change between the morning and afternoon measurements, was used to assess the effect of the contact lens on the corneoscleral morphology. Results. The soft contact lenses had a statistically significant effect on the morphology of the anterior segment layers (p <0.001). The average amounts of change for the three lenses (average RMSD values) for the corneal region were lower (3.93±1.95 µm for the HRL and 4.02±2.14 µm for the EBL) than those measured in the limbal/scleral region (11.24±6.21 µm for the HRL and 12.61±6.42 µm for the EBL). Similarly, averaged across the three lenses, the RMSD in epithelial thickness was lower in the cornea (2.84±0.84 µm) than the limbal/scleral (5.47±1.71 µm) region. Post-hoc analysis showed that ocular surface changes were significantly smaller with the silicone hydrogel sphere lens than both the silicone hydrogel toric (p<0.005) and hydrogel sphere (p<0.02) for the combined HRL and EBL data. Conclusions. In this preliminary study, we have shown that soft contact lenses can produce small but significant changes in the morphology of the limbal/scleral region and that OCT technology is useful in assessing these changes. The clinical significance of these changes is yet to be determined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Over recent years there has been an increase in the literature examining youth with Autism Spectrum Disorders (ASD). The growth in this area of research has highlighted a significant gap in our understanding of suitable interventions for people with ASD and the treatment of co-occurring psychiatric disorders.1-3 Children with ASD are at increased risk of experiencing depressive symptoms and developing depression; however with very few proven interventions available for preventing and treating depression in children with ASD, there is a need for further research in this area.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An optical system which performs the multiplication of binary numbers is described and proof-of-principle experiments are performed. The simultaneous generation of all partial products, optical regrouping of bit products, and optical carry look-ahead addition are novel features of the proposed scheme which takes advantage of the parallel operations capability of optical computers. The proposed processor uses liquid crystal light valves (LCLVs). By space-sharing the LCLVs one such system could function as an array of multipliers. Together with the optical carry look-ahead adders described, this would constitute an optical matrix-vector multiplier.