147 resultados para heat treating
Resumo:
Background Women undergoing Cesarean Section (CS) are vulnerable to the adverse effects associated with perioperative core temperature drop, in part due to the tendency for CS to be performed under neuraxial anesthesia, blood and fluid loss, and vasodilation. Inadvertent perioperative hypothermia (IPH) is a common condition that affects patients undergoing surgery of all specialties and is detrimental to all age groups, including neonates. Previous systematic reviews on IPH prevention largely focus on either adult or all ages populations, and have mainly overlooked pregnant or CS patients as a distinct group. Not all recommendations made by systematic reviews targeting all adult patients may be transferable to CS patients. Alternative, effective methods for preventing or managing hypothermia in this group would be valuable. Objectives To synthesize the best available evidence in relation to preventing and/or treating hypothermia in mothers after CS surgery. Types of participants Adult patients over the age of 18 years, of any ethnic background, with or without co-morbidities, undergoing any mode of anesthesia for any type of CS (emergency or planned) at healthcare facilities who have received interventions to limit or manage perioperative core heat loss were included. Types of intervention(s) Active or passive warming methods versus usual care or placebo, that aim to limit or manage core heat loss as applied to women undergoing CS were included. Types of studies Randomized controlled trials (RCTs) that met the inclusion criteria, with reduction of perioperative hypothermia a primary or secondary outcome were considered. Types of outcomes Primary outcome: maternal core temperature measured during the preoperative, intraoperative and postoperative phases of care Secondary outcomes: newborn core temperature at birth, umbilical pH obtained immediately after birth, Apgar scores, length of Post Anesthetic Care Unit (PACU) stay, maternal thermal comfort. Search strategy A comprehensive search was undertaken of the following databases from their inception until May 2012: ProQuest, Web of Science, Scopus, Dissertation and Theses PQDT (via ProQuest), Current Contents, CENTRAL, Mednar, OpenGrey, Clinical Trials. There were no language restrictions. Methodological quality Retrieved papers were assessed for methodological quality by two independent reviewers prior to inclusion using JBI software. Disagreements were resolved via consultation with the third reviewer. An assessment of quality of the included papers was also made in relation to five key quality factors. Data collection Two independent reviewers extracted data from the included papers using a previously piloted customized data extraction tool. Results 12 studies with a combined total of 719 participants were included. Three broad intervention groups were identified; intravenous (IV) fluid warming, warming devices, leg wrapping. IV fluid warming, whether administered intraoperatively or preoperatively, was found to be effective at maintaining maternal (but not neonatal) temperature and preventing shivering, but does not improve thermal comfort. The effectiveness of IV fluid warming on Apgar scores and umbilical pH remains unclear. Warming devices, including forced air warming and under body carbon polymer mattresses, were effective at preventing hypothermia and reduced shivering, however were most effective if applied preoperatively. The effectiveness of warming devices to improve thermal comfort remains unclear. Preoperative forced air warming appears to aid maintenance of neonatal temperature, while intraoperative forced air warming does not. Forced air warming was not effective at improving Apgar scores and the effects for umbilical pH remain unclear. Conclusions Intravenous fluid warming, by any method, improves maternal temperature and reduces shivering for women undergoing CS. Preoperative body warming devices also improve maternal temperature, in addition to reducing shivering.
Resumo:
A numerical investigation has been carried out for the coupled thermal boundary layers on both sides of a partition placed in an isosceles triangular enclosure along its middle symmetric line. The working fluid is considered as air which is initially quiescent. A sudden temperature difference between two zones of the enclosure has been imposed to trigger the natural convection. It is anticipated from the numerical simulations that the coupled thermal boundary layers development adjacent to the partition undergoes three distinct stages; namely an initial stage, a transitional stage and a steady state stage. Time dependent features of the coupled thermal boundary layers as well as the overall natural convection flow in the partitioned enclosure have been discussed and compared with the non-partitioned enclosure. Moreover, heat transfer as a form of local and overall average Nusselt number through the coupled thermal boundary layers and the inclined walls is also examined.
Resumo:
A large subsurface, elevated temperature anomaly is well documented in Central Australia. High Heat Producing Granites (HHPGs) intersected by drilling at Innamincka are often assumed to be the dominant cause of the elevated subsurface temperatures, although their presence in other parts of the temperature anomaly has not been confirmed. Geological controls on the temperature anomaly remain poorly understood. Additionally, methods previously used to predict temperature at 5 km depth in this area are simplistic and possibly do not give an accurate representation of the true distribution and magnitude of the temperature anomaly. Here we re-evaluate the geological controls on geothermal potential in the Queensland part of the temperature anomaly using a stochastic thermal model. The results illustrate that the temperature distribution is most sensitive to the thermal conductivity structure of the top 5 km. Furthermore, the results indicate the presence of silicic crust enriched in heat producing elements between and 40 km.
Resumo:
Numerical investigation is carried out for natural convection heat transfer in an isosceles triangular enclosure partitioned in the centre by a vertical wall with infinite conductivity. A sudden temperature difference between two zones of the enclosure has been imposed to trigger the natural convection. As a result, heat is transferred between both sides of the enclosure through the conducting vertical wall with natural convection boundary layers forming adjacent to the middle partition and two inclined surfaces. The Finite Volume based software, Ansys 14.5 (Fluent) is used for the numerical simulations. The numerical results are obtained for different values of aspect ratio, A (0.2, 0.5 and 1.0) and Rayleigh number, Ra (10^5 <= Ra <= 10^8) for a fixed Prandtl number, Pr = 0.72 of air. It is anticipated from the numerical simulations that the coupled thermal boundary layers development adjacent to the partition undergoes several distinct stages including an initial stage, a transitional stage and a steady stage. Time dependent features of the coupled thermal boundary layers as well as the overall natural convection flow in the partitioned enclosure have been discussed in this study.
Resumo:
"This is the protocol for a review and there is no abstract. The objectives are as follows: To assess the effects (benefits and harms) of whole-body cryotherapy (cold air exposure) for preventing and treating muscle soreness after exercise in adults." -- publisher website
Resumo:
Osmotic treatments are often applied prior to convective drying of foods to impart sensory appeal aspects. During this process a multicomponent mass flow, composed mainly of water and osmotic agent, takes place. In this work, a heat and mass transfer model for the osmo-convective drying of yacon was developed and solved by the Finite Element Method using COMSOL Multiphysics®, considering a 2-D axisymmetric geometry and moisture dependent thermophysical properties. Yacon slices were osmotically dehydrated for 2 hours in a solution of sucralose and then dried in a tray dryer for 3 hours. The model was validated by experimental data of temperature, moisture content and sucralose uptake (R²> 0.90).
Resumo:
OBJECTIVE: To optimize the animal model of liver injury that can properly represent the pathological characteristics of dampness-heat jaundice syndrome of traditional Chinese medicine. METHODS: The liver injury in the model rat was induced by alpha-naphthylisothiocyanate (ANIT) and carbon tetrachloride (CCl(4) ) respectively, and the effects of Yinchenhao Decoction (, YCHD), a proved effective Chinese medical formula for treating the dampness-heat jaundice syndrome in clinic, on the two liver injury models were evaluated by analyzing the serum level of alanine aminotransferase (ALT), asparate aminotransferase (AST), alkaline phosphatase (ALP), malondialchehyche (MDA), total bilirubin (T-BIL), superoxide dismutase (SOD), glutathione peroxidase (GSH-PX) as well as the ratio of liver weight to body weight. The experimental data were analyzed by principal component analytical method of pattern recognition. RESULTS: The ratio of liver weight to body weight was significantly elevated in the ANIT and CCl(4) groups when compared with that in the normal control (P<0.01). The contents of ALT and T-BIL were significantly higher in the ANIT group than in the normal control (P<0.05,P<0.01), and the levels of AST, ALT and ALP were significantly elevated in CCl(4) group relative to those in the normal control P<0.01). In the YCHD group, the increase in AST, ALT and ALP levels was significantly reduced (P<0.05, P<0.01), but with no significant increase in serum T-BIL. In the CCl(4) intoxicated group, the MDA content was significantly increased and SOD, GSH-PX activities decreased significantly compared with those in the normal control group, respectively (P<0.01). The increase in MDA induced by CCl(4) was significantly reduced by YCHD P<0.05). CONCLUSION: YCHD showed significant effects on preventing liver injury progression induced by CCl(4), and the closest or most suitable animal model for damp-heat jaundice syndrome may be the one induced by CCl(4).
Resumo:
Natural convection thermal boundary layer adjacent to the heated inclined wall of a right angled triangle with an adiabatic fin attached to that surface is investigated by numerical simulations. The finite volume based unsteady numerical model is adopted for the simulation. It is revealed from the numerical results that the development of the boundary layer along the inclined surface is characterized by three distinct stages, i.e. a start-up stage, a transitional stage and a steady stage. These three stages can be clearly identified from the numerical simulations. Moreover, in presence of adiabatic fin, the thermal boundary layer adjacent to the inclined wall breaks initially. However, it is reattached with the downstream boundary layer next to the fin. More attention has been given to the boundary layer development near the fin area.
Resumo:
Bi-2212 tapes were fabricated using a powder-in-tube method and their superconducting properties were measured as a function of heat treatment. The tapes were heated to temperature, T1 (884-915 °C), and kept at that temperature for 20 min to induce partial (incongruent) melting. The samples were cooled to T2 with a ramp rate of 120 °C h-1 and then slowly cooled to T3 with a cooling rate, R2, and from T3 to T4 with a cooling rate, R3. The tapes were kept at the temperature T4 for P1 hours and then cooled to room temperature. Both R1 and R2 were chosen between 2 and 8 °C h-1. It was found that the structure and Jc of the tapes depend on the sintering conditions, i.e. T1-4, R1-3 and P1. The highest Jc of 5800 Å cm-2 was obtained at 77 K in a self-field with heat treatment where T1 = 894 and 899 °C, R1 = R2 = 5 °C h-1 and P1 = 6 h were employed. When 0.7% of bend strain, which is equivalent to a bend radius of 5 mm, was applied to the tape, 80% of the initial Jc was sustained.
Resumo:
This is the protocol for a review and there is no abstract. The objectives are as follows: To assess the effects of intensive glycaemic control compared to conventional control on the outcome of foot ulcers in patients with type 1 and type 2 diabetes.
Resumo:
Australia is a high-potential country for geothermal power with reserves currently estimated in the tens of millions of petajoules, enough to power the nation for at least 1000 years at current usage. However, these resources are mainly located in isolated arid regions where water is scarce. Therefore, wet cooling systems for geothermal plants in Australia are the least attractive solution and thus air-cooled heat exchangers are preferred. In order to increase the efficiency of such heat exchangers, metal foams have been used. One issue raised by this solution is the fouling caused by dust deposition. In this case, the heat transfer characteristics of the metal foam heat exchanger can dramatically deteriorate. Exploring the particle deposition property in the metal foam exchanger becomes crucial. This paper is a numerical investigation aimed to address this issue. Two dimensional (2D) numerical simulations of a standard one-row tube bundle wrapped with metal foam in cross-flow are performed and highlight preferential particle deposition areas.
Resumo:
Australia is a high potential country for geothermal power with reserves currently estimated in the tens of millions of petajoules, enough to power the nation for at least 1000 years at current usage.However, these resources are mainly located in isolated arid regions where water is scarce. Therefore, wet cooling systems for geothermal plants in Australia are the least attractive solution and thus air-cooled heat exchangers are preferred. In order to increase the efficiency of such heat exchangers, metal foams have been used. One issue raised by this solution is the fouling caused by dust deposition. In this case, the heat transfer characteristics of the metal foam heat exchanger can dramatically deteriorate. Exploring the particle deposition property in the metal foam exchanger becomes crucial. This paper is a numerical investigation aimed to address this issue. Two-dimensional(2D numerical simulations of a standard one-row tube bundle wrapped with metal foam in cross-flow are performed and highlight preferential particle deposition areas.
Resumo:
Numerical simulations of thermomagnetic convection of paramagnetic fluids placed in a micro-gravity condition (g ≈ 0) and under a uniform vertical gradient magnetic field in an open ended square enclosure with ramp heating temperature condition applied on a vertical wall is investigated in this study. In presence of the strong magnetic gradient field thermal convection of the paramagnetic fluid might take place even in a zero-gravity environment as a direct consequence of temperature differences occurring within the fluid. The thermal boundary layer develops adjacent to the hot wall as soon as the ramp temperature condition is applied on it. There are two scenarios can be observed based on the ramp heating time. The steady state of the thermal boundary layer can be reached before the ramp time is finished or vice versa. If the ramp time is larger than the quasi-steady time then the thermal boundary layer is in a quasi-steady mode with convection balancing conduction after the quasi-steady time. Further increase of the heat input simply accelerates the flow to maintain the proper thermal balance. Finally, the boundary layer becomes completely steady state when the ramp time is finished. Effects of magnetic Rayleigh number, Prandtl number and paramagnetic fluid parameter on the flow pattern and heat transfer are presented.
Resumo:
Stagnation-point total heat transfer was measured on a 1:27.7 model of the Flight Investigation of Reentry Environment II flight vehicle. Experiments were performed in the X1 expansion tube at an equivalent flight velocity and static enthalpy of 11 km/s and 12.7 MJ/kg, respectively. Conditions were chosen to replicate the flight condition at a total flight time of 1639.5 s, where radiation contributed an estimated 17-36% of the total heat transfer. This contribution is theorized to reduce to <2% in the scaled experiments, and the heating environment on the test model was expected to be dominated by convection. A correlation between reported flight heating rates and expected experimental heating, referred to as the reduced flight value, was developed to predict the level of heating expected on the test model. At the given flow conditions, the reduced flight value was calculated to be 150 MW/m2. Average stagnation-point total heat transfer was measured to be 140 ± 7% W/m2, showing good agreement with the predicted value. Experimentally measured heat transfer was found to have good agreement of between 5 and 15% with a number of convective heating correlations, confirming that convection dominates the tunnel heating environment, and that useful experimental measurements could be made in weakly coupled radiating flow