258 resultados para Thermal fatigue


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present here a numerical study of laminar doubly diffusive free convection flows adjacent to a vertical surface in a stable thermally stratified medium. The governing equations of mass, momentum, energy and species are non-dimensionalized. These equations have been solved by using an implicit finite difference method and local non-similarity method. The results show many interesting aspects of complex interaction of the two buoyant mechanisms that have been shown in both the tabular as well as graphical form.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Treatment-related symptoms continue to place a significant burden on many cancer patients. Many side effects require patients to engage in a range of self-management actions. While some studies have explored self-management of treatment-related side effects in Western settings, very few studies were identified that described the self-management practices of cancer patients in China. Objective: The purposes of this study are to: (1) Investigate Chinese cancer patients. self-management behaviours in dealing with the fatigue, nausea/vomiting and oral mucositis that result from treatment, as well as the perceived effectiveness of these behaviours and related self-efficacy in performing them. (2) Explore factors influencing symptom self-management behaviours using the Cancer Symptom Self-management Framework based on Grey, Knafl and McCorkle.s (2006) self-management framework as a guide. Methods: This study was divided into two phases. Phase One consisted of the translation and modification of two instruments. The adaptation of these instruments to ensure applicability in the Chinese context was achieved through semi-structured interviews with six cancer patients, and content evaluation with eight experienced oncology nurses. A pilot study was conducted with nine cancer patients to trial the questionnaire set in the Chinese context. Based on the results of Phase One, Phase Two involved a cross-sectional survey of Chinese cancer patients undergoing cancer treatment using these instruments. A total of 277 chemotherapy patients with fatigue and/or nausea and vomiting, and 100 radiotherapy patients with oral mucositis were surveyed. Results: Participants in this study reported a variety of self-management behaviours to cope with fatigue, nausea, vomiting and oral mucositis. There are some consistencies as well disparities between strategies that are frequently used and those rated as effective. For fatigue self-management, participants were more likely to use strategies related to rest and sleep, while activity enhancement strategies were rated as achieving higher relief. For nausea and vomiting self-management, dietary modification and taking medication were most frequently used and rated as moderately effective. Psychological strategies were used by more than a third of participants and were rated as mildly effective. Some other infrequently used strategies, such as distraction by keeping busy and acupressure, were rated as moderately effective. For oral mucositis self-management, having soft, bland food and keeping the mouth moisturised were most frequently reported and they were rated as achieving moderate relief. A prescribed mouthwash was used by most but not all participants and brought moderate relief. In general, patients had low-to-moderate self-efficacy in nausea and vomiting self-management behaviours, moderate self-efficacy in fatigue self-management behaviours, and low-to-moderate self-efficacy in oral mucositis self-management behaviours. In terms of the factors influencing symptom self-management, different predictors were identified affecting engagement in fatigue, nausea/vomiting and oral mucositis self-management behaviours. Self-efficacy scores of different behaviours were consistently found to be a positive predictor of the relief level from corresponding behaviours, after controlling for other variables. Perceived social support from health care professionals was identified as an important factor influencing nausea and vomiting self-management behaviours, while neighbourhood support was important for fatigue self-management. In addition, symptom distress was identified as an important factor influencing nausea and vomiting self-management. Conclusion: Similar to reports from overseas, Chinese cancer patients initiate a wide range of self-management behaviours in response to treatment-related side effects. While some behaviours were reported to provide relief, many did not. Given these results, this study has a number of practical implications for health care professionals, particularly in relation to developing tailored self-management programs for fatigue, nausea, vomiting and oral mucositis. Additionally, this study suggests a number of theoretical implications and directions for future research. It is envisaged that these recommendations may pave the way for further studies understanding and promoting cancer symptom self-management in Chinese people affected by cancer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The natural convection thermal boundary layer adjacent to an abruptly heated inclined flat plate is investigated through a scaling analysis and verified by numerical simulations. In general, the development of the thermal flow can be characterized by three distinct stages, i.e. a start-up stage, a transitional stage and a steady state stage. Major scales including the flow velocity, flow development time, and the thermal and viscous boundary layer thicknesses are established to quantify the flow development at different stages and over a wide range of flow parameters. Details of the scaling analysis and the numerical procedures are described in this paper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effects of periodic thermal forcing on the flow field and heat transfer through an attic space are examined numerically in this paper. We consider the case with a fixed aspect ratio of 0.5 and a fixed Grashof number of 1.33×106. The numerical results reveal that, during the daytime, the flow is stratified; whereas at the night-time, the flow becomes unstable. A number of regular plumes and vortices are observed in the contours of isotherms and stream functions respectively. Moreover, the flow appears to be symmetric during the daytime, and becomes asymmetric at the night-time. It is also found that the flow is weaker during the daytime than that at the night-time in the present case, and the calculated heat transfer rate at the night-time is approximately three times greater than the heat transfer rate during the daytime.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of viscous dissipation on natural convection from a vertical plate placed in a thermally stratified environment has been investigated numerically. The reduced equations are integrated by employing the implicit finite difference scheme or Ke1ler-box method and obtained the effect of heat due to viscous dissipation on the local skin-friction and loca1 Nusselt number at various stratification levels, for fluids having Prandtl number equals 10, 50, and 100. Solutions are also obtained using the perturbation technique for small values of viscous dissipation parameters and compared with the Finite Difference solutions. Effect of the heat transfer due to viscous dissipation and the temperature stratification are also shown on the velocity and temperature distributions in the boundary layer region. A numerical study of laminar doubly diffusive free convection flows adjacent to a vertical surface in a stable thermally stratified medium is also considered for this study. Solutions are obtained using the implicit Finite Difference method and compared with the local non-similarity method. The velocity and temperature distributions for different values of stratification parameter are shown graphically. The results show many interesting aspects of complex interaction of the two buoyant mechanisms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Driving is a vigilance task, requiring sustained attention to maintain performance and avoid crashes. Hypovigilance (i.e., marked reduction in vigilance) while driving manifests as poor driving performance and is commonly attributed to fatigue (Dinges, 1995). However, poor driving performance has been found to be more frequent when driving in monotonous road environments, suggesting that monotony plays a role in generating hypovigilance (Thiffault & Bergeron, 2003b). Research to date has tended to conceptualise monotony as a uni-dimensional task characteristic, typically used over a prolonged period of time to facilitate other factors under investigation, most notably fatigue. However, more often than not, more than one exogenous factor relating to the task or operating environment is manipulated to vary or generate monotony (Mascord & Heath, 1992). Here we aimed to explore whether monotony is a multi-dimensional construct that is determined by characteristics of both the task proper and the task environment. The general assumption that monotony is a task characteristic used solely to elicit hypovigilance or poor performance related to fatigue appears to have led to there being little rigorous investigation into the exact nature of the relationship. While the two concepts are undoubtedly linked, the independent effect of monotony on hypovigilance remains largely ignored. Notwithstanding, there is evidence that monotony effects can emerge very early in vigilance tasks and are not necessarily accompanied by fatigue (see Meuter, Rakotonirainy, Johns, & Wagner, 2005). This phenomenon raises a largely untested, empirical question explored in two studies: Can hypovigilance emerge as a consequence of task and/or environmental monotony, independent of time on task and fatigue? In Study 1, using a short computerised vigilance task requiring responses to be withheld to infrequent targets, we explored the differential impacts of stimuli and task demand manipulations on the development of a monotonous context and the associated effects on vigilance performance (as indexed by respone errors and response times), independent of fatigue and time on task. The role of individual differences (sensation seeking, extroversion and cognitive failures) in moderating monotony effects was also considered. The results indicate that monotony affects sustained attention, with hypovigilance and associated performance worse in monotonous than in non-monotonous contexts. Critically, performance decrements emerged early in the task (within 4.3 minutes) and remained consistent over the course of the experiment (21.5 minutes), suggesting that monotony effects can operate independent of time on task and fatigue. A combination of low task demands and low stimulus variability form a monotonous context characterised by hypovigilance and poor task performance. Variations to task demand and stimulus variability were also found to independently affect performance, suggesting that monotony is a multi-dimensional construct relating to both task monotony (associated with the task itself) and environmental monotony (related to characteristics of the stimulus). Consequently, it can be concluded that monotony is multi-dimensional and is characterised by low variability in stimuli and/or task demands. The proposition that individual differences emerge under conditions of varying monotony with high sensation seekers and/or extroverts performing worse in monotonous contexts was only partially supported. Using a driving simulator, the findings of Study 1 were extended to a driving context to identify the behavioural and psychophysiological indices of monotony-related hypovigilance associated with variations to road design and road side scenery (Study 2). Supporting the proposition that monotony is a multi-dimensional construct, road design variability emerged as a key moderating characteristic of environmental monotony, resulting in poor driving performance indexed by decrements in steering wheel measures (mean lateral position). Sensation seeking also emerged as a moderating factor, where participants high in sensation seeking tendencies displayed worse driving behaviour in monotonous conditions. Importantly, impaired driving performance was observed within 8 minutes of commencing the driving task characterised by environmental monotony (low variability in road design) and was not accompanied by a decline in psychophysiological arousal. In addition, no subjective declines in alertness were reported. With fatigue effects associated with prolonged driving (van der Hulst, Meijman, & Rothengatter, 2001) and indexed by drowsiness, this pattern of results indicates that monotony can affect driver vigilance, independent of time on task and fatigue. Perceptual load theory (Lavie, 1995, 2005) and mindlessness theory (Robertson, Manly, Andrade, Baddley, & Yiend, 1997) provide useful theoretical frameworks for explaining and predicting monotony effects by positing that the low load (of task and/or stimuli) associated with a monotonous task results in spare attentional capacity which spills over involuntarily, resulting in the processing of task-irrelevant stimuli or task unrelated thoughts. That is, individuals – even when not fatigued - become easily distracted when performing a highly monotonous task, resulting in hypovigilance and impaired performance. The implications for road safety, including the likely effectiveness of fatigue countermeasures to mitigate monotony-related driver hypovigilance are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tensile and fatigue properties of as-rolled and annealed polycrystalline Cu foils with different thicknesses at the micrometer scale were investigated. Uniaxial tensile testing results showed that with decreasing foil thickness the uniform elongation decreases for both as-rolled and annealed foils, whereas the yield strength and ultimate tensile strength increase for as-rolled foils, but decrease for the annealed foils. For both the as-rolled or annealed foils, bending fatigue resistance decreases with decreasing the foil thickness. Deformation and fatigue damage behaviour of the free-standing foils were characterised as a function of foil thickness. In addition, the fatigue strength of various small-scale Cu foils was compared to understand they physical mechanisms of size effects on mechanical properties of the metallic material at micrometer scales.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cancer-related fatigue (CRF) is a distressing symptom frequently experienced by patients with advanced cancer. While there have been some advances in the understanding of the management of fatigue associated with cancer treatment, CRF associated with advanced cancer remains a phenomenon that is not well-managed. The aetiologic factors associated with CRF, the impacts of CRF and the current management of CRF are discussed in this review article in relation to patients with advanced cancer. The paper concludes that while further research is required in the area, there are several potentially effective strategies currently available that can reduce the severity of CRF in patients with advanced cancer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cold-formed steel stud walls are a major component of Light Steel Framing (LSF) building systems used in commercial, industrial and residential buildings. In the conventional LSF stud wall systems, thin steel studs are protected from fire by placing one or two layers of plasterboard on both sides with or without cavity insulation. However, there is very limited data about the structural and thermal performance of stud wall systems while past research showed contradicting results, for example, about the benefits of cavity insulation. This research was therefore conducted to improve the knowledge and understanding of the structural and thermal performance of cold-formed steel stud wall systems (both load bearing and non-load bearing) under fire conditions and to develop new improved stud wall systems including reliable and simple methods to predict their fire resistance rating. Full scale fire tests of cold-formed steel stud wall systems formed the basis of this research. This research proposed an innovative LSF stud wall system in which a composite panel made of two plasterboards with insulation between them was used to improve the fire rating. Hence fire tests included both conventional steel stud walls with and without the use of cavity insulation and the new composite panel system. A propane fired gas furnace was specially designed and constructed first. The furnace was designed to deliver heat in accordance with the standard time temperature curve as proposed by AS 1530.4 (SA, 2005). A compression loading frame capable of loading the individual studs of a full scale steel stud wall system was also designed and built for the load-bearing tests. Fire tests included comprehensive time-temperature measurements across the thickness and along the length of all the specimens using K type thermocouples. They also included the measurements of load-deformation characteristics of stud walls until failure. The first phase of fire tests included 15 small scale fire tests of gypsum plasterboards, and composite panels using different types of insulating material of varying thickness and density. Fire performance of single and multiple layers of gypsum plasterboards was assessed including the effect of interfaces between adjacent plasterboards on the thermal performance. Effects of insulations such as glass fibre, rock fibre and cellulose fibre were also determined while the tests provided important data relating to the temperature at which the fall off of external plasterboards occurred. In the second phase, nine small scale non-load bearing wall specimens were tested to investigate the thermal performance of conventional and innovative steel stud wall systems. Effects of single and multiple layers of plasterboards with and without vertical joints were investigated. The new composite panels were seen to offer greater thermal protection to the studs in comparison to the conventional panels. In the third phase of fire tests, nine full scale load bearing wall specimens were tested to study the thermal and structural performance of the load bearing wall assemblies. A full scale test was also conducted at ambient temperature. These tests showed that the use of cavity insulation led to inferior fire performance of walls, and provided good explanations and supporting research data to overcome the incorrect industry assumptions about cavity insulation. They demonstrated that the use of insulation externally in a composite panel enhanced the thermal and structural performance of stud walls and increased their fire resistance rating significantly. Hence this research recommends the use of the new composite panel system for cold-formed LSF walls. This research also included steady state tensile tests at ambient and elevated temperatures to address the lack of reliable mechanical properties for high grade cold-formed steels at elevated temperatures. Suitable predictive equations were developed for calculating the yield strength and elastic modulus at elevated temperatures. In summary, this research has developed comprehensive experimental thermal and structural performance data for both the conventional and the proposed non-load bearing and load bearing stud wall systems under fire conditions. Idealized hot flange temperature profiles have been developed for non-insulated, cavity insulated and externally insulated load bearing wall models along with suitable equations for predicting their failure times. A graphical method has also been proposed to predict the failure times (fire rating) of non-load bearing and load bearing walls under different load ratios. The results from this research are useful to both fire researchers and engineers working in this field. Most importantly, this research has significantly improved the knowledge and understanding of cold-formed LSF walls under fire conditions, and developed an innovative LSF wall system with increased fire rating. It has clearly demonstrated the detrimental effects of using cavity insulation, and has paved the way for Australian building industries to develop new wall panels with increased fire rating for commercial applications worldwide.