228 resultados para Technological Protection


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nationally, there is much legislation regulating land sale transactions, particularly in relation to seller disclosure of information. The statutes require strict compliance by a seller failing which, in general, a buyer can terminate the contract. In a number of instances, when buyers have sought to exercise these rights, sellers have alleged that buyers have either expressly or by conduct waived their rights to rely upon these statutes. This article examines the nature of these rights in this context, whether they are capable of waiver and, if so, what words or conduct might be sufficient to amount to waiver. The analysis finds that the law is in a very unsatisfactory state, that the operation of those rules that can be identified as having relevance are unevenly applied and concludes that sellers have, in the main, been unsuccessful in defeating buyers' statutory rights as a result of an alleged waiver by those buyers.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the rapid increase in electrical energy demand, power generation in the form of distributed generation is becoming more important. However, the connections of distributed generators (DGs) to a distribution network or a microgrid can create several protection issues. The protection of these networks using protective devices based only on current is a challenging task due to the change in fault current levels and fault current direction. The isolation of a faulted segment from such networks will be difficult if converter interfaced DGs are connected as these DGs limit their output currents during the fault. Furthermore, if DG sources are intermittent, the current sensing protective relays are difficult to set since fault current changes with time depending on the availability of DG sources. The system restoration after a fault occurs is also a challenging protection issue in a converter interfaced DG connected distribution network or a microgrid. Usually, all the DGs will be disconnected immediately after a fault in the network. The safety of personnel and equipment of the distribution network, reclosing with DGs and arc extinction are the major reasons for these DG disconnections. In this thesis, an inverse time admittance (ITA) relay is proposed to protect a distribution network or a microgrid which has several converter interfaced DG connections. The ITA relay is capable of detecting faults and isolating a faulted segment from the network, allowing unfaulted segments to operate either in grid connected or islanded mode operations. The relay does not make the tripping decision based on only the fault current. It also uses the voltage at the relay location. Therefore, the ITA relay can be used effectively in a DG connected network in which fault current level is low or fault current level changes with time. Different case studies are considered to evaluate the performance of the ITA relays in comparison to some of the existing protection schemes. The relay performance is evaluated in different types of distribution networks: radial, the IEEE 34 node test feeder and a mesh network. The results are validated through PSCAD simulations and MATLAB calculations. Several experimental tests are carried out to validate the numerical results in a laboratory test feeder by implementing the ITA relay in LabVIEW. Furthermore, a novel control strategy based on fold back current control is proposed for a converter interfaced DG to overcome the problems associated with the system restoration. The control strategy enables the self extinction of arc if the fault is a temporary arc fault. This also helps in self system restoration if DG capacity is sufficient to supply the load. The coordination with reclosers without disconnecting the DGs from the network is discussed. This results in increased reliability in the network by reduction of customer outages.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Any incident on motorways potentially can be followed by secondary crashes. Rear-end crashes also could happen as a result of queue formation downstream of high speed platoons. To decrease the occurrence of secondary crashes and rear-end crashes, Variable Speed Limits (VSL) can be applied to protect queue formed downstream. This paper focuses on fine tuning the Queue Protection algorithm of VSL. Three performance indicators: activation time, deactivation time and number of false alarms are selected to optimise the Queue Protection algorithm. A calibrated microscopic traffic simulation model of Pacific Motorway in Brisbane is used for the optimisation. Performance of VSL during an incident and heavy congestion and the benefit of VSL will be presented in the paper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chlamydia trachomatis is a major cause of sexually transmitted diseases worldwide. There currently is no vaccine to protect against chlamydial infection of the female reproductive tract. Vaccine development has predominantly involved using the murine model, however infection of female guinea pigs with Chlamydia caviae more closely resembles chlamydial infection of the human female reproductive tract, and presents a better model to assess potential human chlamydial vaccines. We immunised female guinea pigs intranasally with recombinant major outer membrane protein (r-MOMP) combined with CpG-10109 and cholera toxin adjuvants. Both systemic and mucosal immune responses were elicited in immunised animals. MOMP-specific IgG and IgA were present in the vaginal mucosae, and high levels of MOMP-specific IgG were detected in the serum of immunised animals. Antibodies from the vaginal mucosae were also shown to be capable of neutralising C. caviae in vitro. Following immunisation, animals were challenged intravaginally with a live C. caviae infection of 102 inclusion forming units. We observed a decrease in duration of infection and a significant (p<0.025) reduction in infection load in r-MOMP immunised animals, compared to animals immunised with adjuvant only. Importantly, we also observed a marked reduction in upper reproductive tract (URT) pathology in r-MOMP immunised animals. Intranasal immunisation of female guinea pigs with r-MOMP was able to provide partial protection against C. caviae infection, not only by reducing chlamydial burden but also URT pathology. This data demonstrates the value of using the guinea pig model to evaluate potential chlamydial vaccines for protection against infection and disease pathology caused by C. trachomatis in the female reproductive tract.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on the use of the hydrogen bond accepting properties of neutral nitrone moieties to prepare benzylic-amide-macrocycle-containing [2]rotaxanes in yields as high as 70 %. X-Ray crystallography shows the presence of up to four intercomponent hydrogen bonds between the amide groups of the macrocycle and the two nitrone groups of the thread. Dynamic 1H NMR studies of the rates of macrocycle pirouetting in nonpolar solutions indicate that amide-nitrone hydrogen bonds are particularly strong, ~1.3 and ~0.2 kcal mol-1 stronger than similar amide-ester and amide-amide interactions, respectively. In addition to polarizing the N-O bond through hydrogen bonding, the rotaxane structure affects the chemistry of the nitrone groups in two significant ways: The intercomponent hydrogen bonding activates the nitrone groups to electrochemical reduction, a one electron reduction of the rotaxane being stablized by a remarkable 400 mV (8.1 kcal mol-1) with respect to the same process in the thread; encapsulation, however, protects the same functional groups from chemical reduction with an external reagent (and slows down electron transfer to and from the electroactive groups in cyclicvoltammetry experiments). Mechanical interlocking with a hydrogen bonding molecular sheath thus provides a route to an encapsulated polarized functional group and radical anions of significant kinetic and thermodynamic stability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Presently, the manufacturing sector faces unprecedented levels of competition in both the domestic and international markets. This competition is mainly as a result of rapidly expanding international trade, gradual removal of protection, substantial reforms in labour markets and industrial relations, rapid technological changes and discerning customers. Intense global competition requires manufacturers to deliver products with higher quality in a shorter time. Simultaneously, owing to new technological innovations, the complexity of the products is increasing. In Australia, the impact of this intense competition and structural changes appear to be having negative effects on the manufacturing sector. This paper discusses the quality and reliability (Q & R) practices and associated drawbacks of Australian manufacturers and presents the findings of an investigation of the challenges Australian manufacturers are currently facing. The results reported in the paper are based on the data collected from a survey using the standard questionnaire. The study was driven by a conceptual model, which relates advanced quality practices to manufacturing performance and manufacturing difficulties.Evidence indicates that Q & R is the main competitive factor for Australian manufacturers. Design capability and on time delivery (OTD) came second. Results show that Australian manufacturers in general are facing some manufacturing difficulties. The relationship between advanced quality practices and company performance and manufacturing difficulties are explored. It is found that the companies who have more emphasis on advanced quality practices have fewer problems in manufacturing practices. Moreover, companies who have actively implemented the advanced quality practices have managed to improve the quality of the product continuously. The results validate the proposed hypothesis and lend credence to current thinking that improvement in Q & R is a vital tool for competitive advantage.